New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding



Similar documents
Assessing RAID ADG vs. RAID 5 vs. RAID 1+0

RAID 6 with HP Advanced Data Guarding technology:

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

QuickSpecs. HP Smart Array 5312 Controller. Overview

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

RAID 5 rebuild performance in ProLiant

TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS

RAID Technology Overview

Hot-Plug Disk Drive Removal and Replacement Guidelines for Compaq Smart Array Controllers

HP Smart Array Controllers and basic RAID performance factors

HP Embedded SATA RAID Controller

How to choose the right RAID for your Dedicated Server

QuickSpecs. Models. HP Dynamic Smart Array B320i Controller. Overview

This user guide describes features that are common to most models. Some features may not be available on your computer.

RAID Level Descriptions. RAID 0 (Striping)

QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview

HP and Mimosa Systems A system for archiving, recovery, and storage optimization white paper

HP Embedded SATA RAID Controller

RAID 1(+0): breaking mirrors and rebuilding drives

RAID 1(+0): breaking mirrors and rebuilding drives

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

How To Use An Hp Smart Array P212 (Sas) With A 1-Year Warranty On A 2 Terabyte Hard Drive (Sata) And A 1 Terabyte (Sasa) Hard Drive With A 2-Year License (S

Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.

RAID Basics Training Guide

Smart Array Technology: Basics and Advantages of Battery-Backed Cache

QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller

HP Array Configuration Utility User Guide

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

Increasing Server Storage and Capacity: Upgrading the SMART-2DH Controller to the Smart Array 4200 Controller

Smart Array technology: advantages of battery-backed cache

Using HP ProLiant Network Teaming Software with Microsoft Windows Server 2008 Hyper-V or with Microsoft Windows Server 2008 R2 Hyper-V

It is also available as part of the HP IS DVD and the Management DVD/HPSIM install.

QuickSpecs. What's New HP 750GB 1.5G SATA 7.2K 3.5" Hard Disk Drive. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

HP StorageWorks Automated Storage Manager User Guide

QuickSpecs. HP StorageWorks Modular Smart Array 500 G2. Overview

QuickSpecs. What's New New GB Pluggable Ultra320 SCSI 15,000 rpm Universal Hard Drive (1") HP SCSI Ultra320 Hard Drive Option Kits (Servers)

IBM ^ xseries ServeRAID Technology

QuickSpecs. Models. HP Smart Array P731m Controller. Overview

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

Technical White paper RAID Protection and Drive Failure Fast Recovery

Redundant Array of Independent Disks (RAID)

QuickSpecs. What's New Dual Port SFF 10K and 15K SAS drives Dual Port 3.5" 15K SAS drives. HP SAS Drives (Servers) Overview

RAID EzAssist Configuration Utility Quick Configuration Guide

QuickSpecs. HP StorageWorks 60 Modular Smart Array. Overview

HP ProLiant Essentials Performance Management Pack 3.0 Support Matrix

Xserve G5 Using the Hardware RAID PCI Card Instructions for using the software provided with the Hardware RAID PCI Card

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

Legal Notices Introduction... 3

QuickSpecs. HP Dynamic Smart Array Controllers. Models HP Dynamic Smart Array RAID Controllers. HP Dynamic Smart Array Controllers.

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment

Configuring ThinkServer RAID 100 on the TS140 and TS440

Installing Microsoft Windows

Customizing Asset Manager for Managed Services Providers (MSP) Software Asset Management

QuickSpecs. What's New HP 3TB 6G SAS 7.2K 3.5-inch Midline Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives. Overview

Using RAID6 for Advanced Data Protection

HP ProLiant Cluster for MSA1000 for Small Business Hardware Cabling Scheme Introduction Software and Hardware Requirements...

technology brief RAID Levels March 1997 Introduction Characteristics of RAID Levels

Benefits of Intel Matrix Storage Technology

Education. Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller. Study guide. XW5078 Release 1.00

HP OpenView Smart Plug-in for Microsoft Windows Data sheet

HP StorageWorks 20 Modular Smart Array Overview

MANAGING DISK STORAGE

Synchronizing ProCurve IDM and Windows Active Directory

HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits. Overview

QuickSpecs. HP SATA Hard Drives. Overview

How To Use An Hpl Storage Manager On A 2Tb Server On A Microsoft Server On An Ubuntu 2Tv 2Tva 2Tfs 2 (Ahem) Or 2Tvi 2 (I386) On A Server

BrightStor ARCserve Backup for Windows

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs. Models HP ProLiant Storage Server iscsi Feature Pack. Overview

ProLiant Essentials Intelligent Networking Active Path Failover in Microsoft Windows environments

How To Create A Multi Disk Raid

HP Storage Data Migration Service

Microsoft File and Print Service Failover Using Microsoft Cluster Server

What is RAID--BASICS? Mylex RAID Primer. A simple guide to understanding RAID

Using ATI Array Management Software (WebPAM)

How to register. Who should attend Services, both internal HP and external

IncidentMonitor Server Specification Datasheet

Server Virtualization with Windows Server Hyper-V and System Center (20409) H8B93S

QuickSpecs. Integrated NC3163 Fast Ethernet NIC PCI 10/100 with full WOL (Wake On LAN) and PXE support. Overview. Models.

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device

QuickSpecs. Models. Overview

Rapport Administrative Software for Compaq Thin Clients

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

HP Recommended SMART Array Rebuilding/Restoring Techniques

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

Guide to SATA Hard Disks Installation and RAID Configuration

Presales Certifications

QuickSpecs. HP SAS Enterprise and SAS Midline Hard Drives Overview

QuickSpecs. Models HP 750GB 7200rpm SATA (NCQ/Smart IV) 3Gbp/s Hard Drive

Transcription:

White Paper October 2000 Prepared by Storage Products Group Compaq Computer Corporation Contents Introduction...2 What customers can expect from Compaq RAID ADG solution...3 RAID ADG Features and Benefits...3 Choosing a RAID level...5 When customers should use RAID ADG...6 Summary...6 Notice...7 New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding Abstract: The purpose of this paper is to communicate the advantages of utilizing Compaq s new RAID innovation, Advanced Data Guarding (ADG). RAID ADG provides a new level of fault protection at a high level of capacity utilization. Designed to be first supported on the Smart Array 5300 Controller, RAID ADG is ideal for applications requiring larger storage volumes, delivering a powerful fault tolerant solution at a lower implementation price. Every Compaq server customer implementing an array with 8 or more hard disk drives should consider this new RAID level. This innovative Compaq solution for the Smart Array 5300 is patent pending and is not a feature of competitors PCI RAID products.

New Advanced RAID Level for Today's Larger Storage Capacities: 2 Introduction With a growing need for larger storage capacity, customers are demanding reliable ways to protect large volumes of data stored across an increasing number of disk drives. RAID technology allows a group of disk drives to be tied together to act like a single logical disk drive from the operating system perspective, providing increased performance and fault tolerance. Currently, Compaq offers very reliable RAID systems with the family of Smart Array Controllers that support RAID 0, 1, 0+1, and 5. For customers who wish to create large logical drives with a high number of disk drives or high capacity disk drives they need to consider the limitation of current RAID schemes. With RAID 1, it is expensive to create large volumes based upon the consumption of disk drives for mirroring. With RAID 5, it is not recommended to configure a logical drive array with greater than 14 drives due to risk of data loss. In addition, today s larger disk drive capacities may leave an array exposed to a considerable amount of risk following a single disk drive failure due to the time required to rebuild the failed drive. A second drive failure in a mirrored set in RAID 1 and any second drive failure in RAID 5 would cause an array to fail, causing data loss and downtime. With this in mind, larger capacity disk drives present new risks due to longer drive rebuild times. Compaq s new Advanced Data Guarding reduces the risk of an array failure and requires far less storage capacity overhead than RAID 1. The following table illustrates the current RAID levels used by customers, their purposes, and limitations, compared to the new advanced RAID level from Compaq: Table 1. RAID levels and functions RAID LEVEL PURPOSE LIMITATION RAID 0 RAID 1, 0+1 RAID 5 NEW RAID ADG Increased performance when no RAID protection is required. Mirroring: Identical data stored on multiple drives, high fault tolerance, improved performance. Distributed Data Guarding: Parity data is distributed across all drives. Protects against the failure of any one drive in an array. Provides improved performance at a minimum cost. Advanced Data Guarding: Two sets of parity data distributed across all drives. Protects against the failure of any two drives in an array. Provides high fault tolerance at a minimum implementation cost. No fault tolerance and highly vulnerable to failure. Requires 50% of capacity to be dedicated to fault protection. Expensive to implement across large volumes (doubling the costper-capacity). Lower fault tolerance. Not recommended for volumes greater than 14 drives. Too risky for large volumes. Lower performance than other RAID levels.

New Advanced RAID Level for Today's Larger Storage Capacities: 3 What customers can expect from Compaq RAID ADG solution RAID ADG is a new advanced RAID level that increases the number of sets of parity, creating multiple sets striped across the disks to provide unparalleled fault tolerance, greater than RAID 1 or RAID 5, and at a lower cost implementation than RAID 1. Designed for support on the Smart Array 5300 Controller, RAID ADG is ideal for applications requiring large volumes. Available in the 1 st quarter of 2001, with the Smart Array 5300 Controller, RAID ADG can safely protect an array up to 56 total drives, ensuring customers of a powerful solution with high fault tolerance. Some customers needs now require a fault tolerance scheme that would provide higher reliability than RAID 5 at a lower cost than RAID 1. Compaq recognized these customers needs for high capacity RAID protection on a single storage array that could span a large number of disks. Customers can now complete their server/storage solution with a Compaq innovation - Advanced Data Guarding (RAID ADG) system. RAID ADG Features and Benefits RAID ADG can tolerate multiple simultaneous drive failures without downtime or data loss. 1 Can safely protect an array up to 56 total drives Greater fault tolerance than RAID 1 or RAID 5 Lower implementation cost than RAID 1 Supports Online Spare Drive Ideal for applications requiring large logical drives Supports Online RAID Level Migration from RAID 1 or RAID 5 1 A RAID ADG Enabler Module must be attached to the controller to enable RAID ADG configuration via Array Configuration Utility (ACU). The module is shipped with the 128MB cache board.

New Advanced RAID Level for Today's Larger Storage Capacities: 4 RAID ADG provides greater fault tolerance With growing numbers of individual disk drives needed in a single logical volume on a single controller, RAID ADG provides higher data reliability than previously available from a RAID storage provider. In Figure 1 below, RAID ADG has a superior fault tolerance when compared to RAID 5 or RAID 1. Figure 1 shows the probability of logical drive failure for various RAID levels and different physical drive counts: With RAID 0, the logical drive will fail if one physical drive fails. With RAID 5, the logical drive will fail if two physical drives fail. With RAID 1 or 0+1, the maximum number of hard drives that can fail without failure of the logical dive is n/2. However, a RAID 0+1 logical drive will fail if only two hard drives fail, if they are mirrored to each other. With RAID ADG, three hard drives must fail before data loss is incurred. Figure 1. RAID ADG Fault Tolerance Comparison Total number of physical drives 1 6 11 16 21 26 31 36 41 46 51 56 1% Probability of Data Loss Due to Second Hard Disk Drive Failure e RAID 0 RAID 5 RAID 1 RAID ADG 0.00000000001%

New Advanced RAID Level for Today's Larger Storage Capacities: 5 Choosing a RAID level Customers should consider a variety of factors when choosing which RAID level best suited for their needs. These factors include: 1. Capacity utilization and budget; 2. Availability and Uptime requirements; and 3. Performance requirements. Tables 2 and 3 help determine which RAID level best suits particular requirements. Table 2. Choosing a RAID method. MOST IMPORTANT SECONDARY IMPORTANCE RAID LEVEL CHOICE Cost Effectiveness (cost per usable capacity) Fault Tolerance Performance Fault Tolerance RAID ADG Performance RAID 5 (RAID 0 if fault tolerance is not needed) Cost Effectiveness RAID ADG Performance RAID 0+1 Cost Effectiveness RAID 5 (RAID 0 if fault tolerance is not needed) Fault Tolerance RAID 0+1 Table 3. RAID Level Decision Tree RAID Level Decision Tree NO Fault Tolerance YES 2 # of Disk Drives 8 or more 3-7 Higher performance Performance vs. Capacity Higher capacity utilization RAID 0 RAID 1 RAID 0+1 RAID 5 RAID ADG

New Advanced RAID Level for Today's Larger Storage Capacities: 6 When customers should use RAID ADG Advanced Data Guarding is ideal for applications requiring larger storage volumes. RAID ADG is best implemented when customers have the following needs: For greater capacity utilization For mission-critical data When large logical drives are required When better capacity utilization than RAID 1 is needed When higher fault tolerance than RAID 1 or RAID 5 is necessary In addition, customers can migrate from their existing RAID levels to RAID ADG and from RAID ADG to other RAID levels as well. Note: If a RAID volume does not have available capacity equal to one disk drive, it may require adding a disk drive and expanding the RAID volume. Refer to the Compaq User Manual for more detailed information. Summary With RAID ADG, the new Compaq exclusive and advanced RAID level, customers are provided with a capacity utilization that is ideal for large capacity logical drives. Every Compaq server customer implementing RAID volumes with 8 or more hard disk drives should consider this new RAID level. This innovative Compaq solution for today s large storage capacities is not provided by any other competitor. Note: RAID ADG is standard with the Compaq Smart Array 5304/128 and will be sold as an option with Smart Array models 5302/64 and 5302/32. RAID ADG will be available in 1Q/2001.

New Advanced RAID Level for Today's Larger Storage Capacities: 7 Notice [Document number or part number] 2000 Compaq Computer Corporation COMPAQ and the Compaq logo, Registered U.S. Patent and Trademark Office. ProLiant is a trademark of Compaq Information Technologies Group, L.P. Microsoft and Windows NT are trademarks of Microsoft Corporation. All other product names mentioned herein may be trademarks of their respective companies. Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is subject to change without notice. The limited warranties for Compaq products are exclusively set forth in the documentation accompanying such products. Nothing herein should be construed as constituting a further or additional warranty. Printed in the U.S.A. First Edition (October 2000) Document Number

New Advanced RAID Level for Today's Larger Storage Capacities: 8