Portable Video Intubation Stylet. Thomas G. Boronkay, Janak Dave, Jamiel Trimble. University of Cincinnati

Similar documents
COOPDECH Video Laryngoscope Portable VLP-100

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC October 26, 2012

Neonatal Intubation. Purpose. Scope. Indications. Equipment Cardiorespiratory monitor SaO 2 monitor. Anatomic Considerations.

Pediatric Airway Management

TRACHEOSTOMY TUBE PARTS

Laryngoscopes - Introduction

INFORMATION ON DO-NOT-RESUSCITATE (DNR) REQUESTS IN EMERGENCY MEDICAL SERVICES

One Lung Ventilation Module (OLV)

Endoscope Optics. Chapter Introduction

Department of Veterans Affairs Emergency Airway Management Initiative

Enables MDA Medical Teams to categorize victims in mass casualty scenarios, in order to be able to triage and treat casualties

Detachable DIY Door Viewer Camera for Home / Office Safety. Installation Manual. (* This is a patented product, do not copy) IA Technologies Inc.

The Difficult Airway. The Difficult Airway. Difficult Airway Algorithms: ASA. Ectopic Anesthesia. Cancel Case. Awaken. airway. Defining ng the problem

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

AIRWAY MANAGEMENT. Angkana Lurngnateetape, MD. Department of Anesthesiology Siriraj Hospital

Continued on next page

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

Tube Control Measurement, Sorting Modular System for Glass Tube

Product End-of-Life Disassembly Instructions

Rapid prototyping. CAD / lecture. October 5, TO&I Vermelding onderdeel organisatie

Allison Rae Paramount Industries Rhode Island School of Design ID 87. Prototyping Overview

Video Camera Installation Guide

Standard laryngoscope blade assemblies Directions for use

AC : CONVERSION OF AN EXISTING CAR TO A RECHARGEABLE ELECTRIC VEHICLE

NAME OF HOSPITAL LOCATION DATE

Day / Night IR Color Camera User Manual V2.1.0

Epidural Continuous Infusion. Patient information Leaflet

STATE OF NEBRASKA STATUTES RELATING TO RESPIRATORY CARE PRACTICE ACT

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

NuMount VESA Adapter for imac ASSEMBLY MANUAL

AEROSPACE MEDICAL SERVICE SPECIALTY INDEPENDENT DUTY MEDICAL TECHNICIAN EMERGENCY MEDICINE PROCEDURES

Impact Uni-Vent 750 Portable Ventilator

Over the past decade, video laryngoscopy has profoundly. The Video Laryngoscopy Market: Past, Present, and Future

Laryngeal Mask Airways (LMA), Indications and Use for the Pre-Hospital Provider.

Michigan Adult Cardiac Protocols CARDIAC ARREST GENERAL. Date: May 31, 2012 Page 1 of 5

AMPSEAL* Automotive Plug Connector and Header Assembly

Educational Tool for Medical Laser Programs 1. Laser Safety

Critical Care Therapy and Respiratory Care Section

DSM155 Digital LED Light Meter User s Manual DSM155

CHAPTER 65 TAIL ROTOR DRIVE SYSTEM. Section Title Page

LESSON 4 ORAL, NASOPHARYNGEAL, AND NASOTRACHEAL SUCTIONING.

National Registry Skill Sheets

Tucson Eye Care, PC. Informed Consent for Cataract Surgery And/Or Implantation of an Intraocular Lens

2012 Operating Room Design Manual

Eye Tracking System Instruction. Manual. Model Mobile Head Mounted Optics with Mobile Electronics Package (Addendum to Model 501 manual)

Back-Up Camera Installation Guide

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Performance Standards. Veterinary Technology Distance Learning Program (VTDLP) San Juan College 4601 College Blvd Farmington, NM 87402

KING VISION VIDEO LARYNGOSCOPE Instruction Manual For Use with Standard and Channeled Blades

SOLAR POWER - THE NEW WAY TO RV!

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

National- Spencer Inc.

Control Box Wiring For PRSstandard Tool

Perioperative Management of Patients with Obstructive Sleep Apnea. Kalpesh Ganatra,MD Diplomate, American Board of Sleep Medicine

METHODS OF BOLUSING THE TRACHEOSTOMY STOMA

EMERGENCY MEDICAL TECHNICIANS REGULATION

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

State of New Hampshire Department of Safety Division of Fire Standards and Training & Emergency Medical Services

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Impact Uni-Vent 754 Portable Ventilator

UC Davis Medical Center Emergency Medicine Airway Equipment: Contents, Cleaning and Stocking

NCCEP Standards. NCCEP Standards for EMS Equipment

Standard WIRED Installation Guide

Park 250 Brushless Outrunner Instructions

Design and Construction Criteria C. Utility Coordination

=============================== WARNING

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

C-MAC S Video Laryngoscope

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

VISM CQB Scope Series

Target groups: Paramedics, nurses, respiratory therapists, physicians, and others who manage respiratory emergencies.

Standards for type V air ambulance vehicles and equipment. (a) The operator shall ensure that the patient compartment is configured in

4.3-inch Back-Up Camera

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

INSTALLATION MANUAL. Installation Instructions

endotracheal tube guide We provide Rusch quality.

Shiley Product Guide. Shiley TM XLT Extended-Length Tracheostomy Tubes. Shiley TM Disposable Inner Cannula

Canine Tactical Combat Casualty Care

Orthopaedic Spine Center. Anterior Cervical Discectomy and Fusion (ACDF) Normal Discs

jbs nfb INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Mechanical Steering for Inboard, Outboard, and Sterndrive Powered Vessels

Providing quality emergency care in rural hospitals

Product Guide Specification

Emergency Medical Services Advanced Level Competency Checklist

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

(ISBN: ) Preferred Package Digital Supplement

RESPIRATORY THERAPIST CLASSIFICATION SERIES

CERVICAL MEDIASTINOSCOPY WITH BIOPSY

THE EFFECTS OF NURSE EDUCATION AND CERTIFICATION ON HOSPITAL- ACQUIRED INFECTIONS

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

Innovation From Concept to Production

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Copyright 2009, National Academy of Ambulance Coding Unauthorized copying/distribution is strictly prohibited

RETRACTABLE LANDING GEAR

GUIDELINES FOR THE MANAGEMENT OF OXYGEN THERAPY

Transcription:

Session #3649 Portable Video Intubation Stylet Thomas G. Boronkay, Janak Dave, Jamiel Trimble University of Cincinnati Students working toward the Baccalaureate degree in Mechanical Engineering Technology at the University of Cincinnati are required to complete a Design, Build & Test Capstone design project. Some of these projects are geared to meet the needs of the local community. Intubation is a procedure by which an endotracheal tube is inserted into the trachea of a patient who requires assistance in breathing. It is a blind procedure that relies on imperfect, indirect methods for proper tube placement. This can be difficult and dangerous if the endotracheal tube is inserted in the esophagus. This procedure is typically performed by EMTs (Emergency Medical Technicians) while responding to emergency situations. This paper describes a new intubation device, designed, developed and built as a capstone design project, which will improve the success rate of the intubation procedure. Introduction The need for intubation often arises from cardiac and/or pulmonary arrest. The intubation process is often difficult, and potentially dangerous to the patient. The success rate of intubation ranges from between 25% to 37% (1). In addition, accidental placement of the ET tube in the esophagus, called Esophageal Intubation, can lead to death, due to the lack of oxygen. K.Posner, R. Ward and F. Cheney (2), report Clinical Outcomes of Esophageal Intubations as follows: 81% died. 17% permanent brain damage. 1 % other permanent injury. 1 % Temporary injury. 0% No injury. Properly negotiating the anatomy of the airway to place the endotracheal tube in the trachea requires that the intubator (EMTs) visualizes the endotracheal tube passing through the vocal Proceedings of the 2004 American Society for Engineering Education Annual Conference & Exposition Page 9.995.1

cords of the patient during the procedure. Presently, the intubations performed by paramedics are accomplished with the help of a tool called a laryngoscope. Figure 2 Laryngoscope A laryngoscope is an instrument held with the left hand during intubation, and is used to divert the patient's tongue and epiglottis, thereby manipulating the oral cavity to expose the vocal cords. However, even when the laryngoscope is in an optimal position, the vocal cords may not be visualized for a number of reasons. Some of these include: small mouth opening, inability to flex the neck due to trauma, or the anterior position of the larynx. The proper placement of the endotracheal tube in the trachea is essential in every intubation. Fig 2 shows an EMT in bent position, performing an intubation on a mannequin, using a laryngoscope. Please note the awkward position of both the EMT and the patient. The objective of this project was to develop a product to increase the success rate of the intubation procedure. Page 9.995.2

Fig 2 Paramedic Performing an Intubation using a Laryngoscope Design As with any project development, the first step was to survey customers to obtain their input to the design process. The survey was given to physicians, nurses and paramedics (EMTs). Some sample questions on the survey were: What is the most common complication of Endotracheal Intubation? How often do you attempt a Blind Intubation? How often are the vocal cords not visible? What is the common condition making the visualization of the vocal cords difficult? Would a device increasing the visibility of the vocal cords, when direct line of sight is not possible, improve the success rate of and time required for intubations? The survey results and input obtained through personal interviews and the personal experience of Mr. Trimble, who works as an EMT, were used in developing product specifications. Additionally, existing products were researched. Two of the current products on the market are Lighted Stylet and Combitube. The Lighted Stylet illuminates the patient s mouth, but the intubation is still blind. The Combitube can be inserted blindly and ventilation is achieved when the device has successfully entered the trachea. The disadvantage of this device is that the tracheal placement occurs only in 20% of the cases in the initial try. In the rest of the cases it enters the esophagus and must be retracted immediately. Product Specifications: The device will accommodate Endotracheal tubes from 6.5 mm to 8.5 mm ID The device will weigh less than 5 lbs The device will facilitate vocal cord visibility during intubations He device will accommodate both nasal and oral intubations Page 9.995.3

Three conceptual designs were developed. The best one, Portable Video Intubation Stylet (PVIS), was identified using the Pugh Selection method. Portable Video Intubation Stylet (PVIS) Fig. 3 Portable Video Intubation Stylet The design of the Portable Video Intubation Stylet (PVIS, fig 3) was divided into 3 main sections. Those sections and their functions are listed below. Handle The handle is composed of a base and a top. The handle section of this device houses the power supply, the CCD (Charge-coupled device) camera, switch, and battery contacts. The handle was designed using Ergonomic/Human Factor Engineering standards (3). The production material of the handle will be medical grade HDPE. The handle will be produced using injection molding. However the prototype was produced by using a rapid prototyping process, using HDPE. Power Supply - The Power supply used is a 12v Ni-Ca battery. This is a military battery rated at 12v with max discharge 1330 ma continuous. This power unit provides power for both the CCD camera and the LCD display unit. CCD Camera This High Quality color board Camera, requires a 12 volt power supply rated at 120 ma. It will operate at very low light availability (1 Lux). The selected CCD has a Composite Video output, which is compatible with the selected LCD. The CCD is mounted inside the handle base of the device. Page 9.995.4

Display Unit The display is comprised of a LCD panel, and a face plate. LCD Panel- The LCD display unit is a miniature color video monitor, which accepts composite video input and produces a high resolution (234 H x 200 V) full color video on it's screen. The input/outputs of this device are compatible with the CCD and the power supply. Face plate/display unit It was designed using Ergonomic/ Human Factor Engineering standards. (3) The material used is the same as the handle material. Fiber Optic Image Unit The fiber optic image unit consists of a wound image bundle, and a lens set-up at the proximal end of the fiber optic bundle. Wound Image Bundle - Wound image bundles are produced by winding a multi fiber one layer at a time on a drum and assembling the desired number of layers in a separate laminating operation. The final flexible image bundle is comprised of individual multi-fibers bound only at the ends and separated in between, making it possible to transmit a high resolution image from end to end. Lens - The lens is be used to capture the image just distal of the image bundle. This lens is permanently fused to fiber optics prior to shipping. The lens is responsible for transmitting the image received from the proximal end of the fiber optics to the CCD. Manufacturing & Assembly The manufacturing phase of this prototype was divided into two parts: the outer shell housing, and the lens set-up housing. The outer shell housing consists of the handle and the LCD housing and supports. The material for the housing was Somos 10120 water clear plastic. The part was produced using SLA (Stereo lithography) at ANZA Rapid Prototype of Cincinnati. The lens setup housing holds the lens needed to project an image from the proximal end of the fiber optics to the CCD camera. The material for the lens housing was ABS. It was milled in the College s shop using specifications obtained from Myriad Fiber Optics of Boston. All assembly was performed manually in house. All parts were dry fitted, and primary tests were run to ensure proper operation prior to final assembly. For final assembly SLA parts were bonded using cyanoacrylate glue. Milled parts were assembled with thread and screw fasteners for easy assembly and disassembly. The electrical components were connected in accordance with the prepared electrical schematic shown in fig 4. Page 9.995.5

Fig 4 Testing The PVIS accommodated endotracheal tubes from 4mm to 8.5 mm in diameter and it weighed 4.3 lbs. The device was tested by EMTs on a mannequin for intubation. The same EMTs performed intubation using the standard Laryngoscope. Both of these attempts were limited to twenty seconds. The intubation failure rate, using the standard Laryngoscope was forty percent, but was reduced to ten percent, using the PVIS. This improvement can be attributed to improved vocal cord visibility. As can be seen in figure 2, using the standard method, the EMTs have to bend over, whereas using the PVIS (fig 5) they can perform the intubation in a more comfortable position. Fig 5 Paramedic Performing an Intubation using PVIS Page 9.995.6

Conclusions References: PVIS is a definite improvement over the existing methods for the intubation process. It allows for better visibility of the vocal cords minimizing esophageal intubation. It also allows the EMTs and patients to be in a more comfortable posture during the procedure. Because of the liability issues the device was tested only on mannequins. It must be tested in the field before it can be adopted for wide spread use. 1 JEMS (Journal of Emergency Medicine) 2003 2 Adverse Respiratory Events in Anesthesia: A Closed Claim Analysis; Caplan R., Posner K., Ward R., Cheney F., Anesthesiology 1990 3 Designing for Humans: The Human Factor in Engineering; John H. Burgess 4 FDA, US Food and Drug Administration Center for Devices and Radiological Health 5 Paramedic Emergency Care, Robert S. Porter, Brady, 2 nd Edition Thomas G. Boronkay, PhD, PE is a Professor in the Mechanical Engineering Technology department at the University of Cincinnati. He received his PhD from the University of Cincinnati. He has presented papers at ASEE Annual Conferences, ASME International Congress, and several international conferences and conducted CAD/CAM/CAE workshops nationally and internationally. He has also served in various capacities on the DEED, EDG and International Divisions executive committees. Janak Dave PhD, PE is a Professor in the Mechanical Engineering Technology department at the University of Cincinnati. He obtained his MS and PhD in Mechanical Engineering from the University of Missouri at Rolla. He has presented papers at ASEE Annual Conferences, ASME International Congress, and several International conferences and conducted CAD/CAM/CAE workshops nationally and internationally. He has held various positions in EDG and DEED divisions of ASEE, and local and national committees of ASME Jamiel Trimble received his Bachelor of Science in Mechanical Engineering Technology from the University of Cincinnati in June 2003. He had been working as an EMT with the Cincinnati fire department throughout his college career. He continues to work there while finalizing his future plans. Page 9.995.7