DTT Opta Digital torque tester and data collector

Similar documents
Key Features. Product Overview. Threaded Joint Rate Simulator

T Substation Maintenance and Commissioning Test Equipment

Instruction Manual FL

Melting Point Apparatus

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

User's Guide. Integrating Sound Level Datalogger. Model Introduction

TR Series Surface Roughness Tester for workshop and laboratory

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

Product Information Sheet UH36 Hi Pot Tester

Nardalert S3 Non-Ionizing Radiation Monitor

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

SNMP Web Management. User s Manual For SNMP Web Card/Box

Paint Test Equipment. Stargloss Gloss Meter Data Sheet

Ultrasonic Load Monitoring

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

MINIMAT-EC-Servo Screwdriver Spindles

Concrete 37 Compression machine accessories. ADR-Auto Console. Load Calibration Devices. Compression Machine Accessories

How To Use A Detector 2

Kit Highlights and Key Features

Hand-held thermometer Model CTH7000

10 Thomas, Irvine, CA USA Tel: (949) Fax: (949) Toll Free: (800) 23 FUTEK

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

BW-500 BED WEIGHER USER MANUAL

Data Sheet FUJITSU Display E19-7 LED

DC Electronic Loads 8500 series

CYMAQ Marking System AS200 + DS7050 N-14

HT580 User Reference Guide. Version 1.0

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Inspiron Series. Views. Specifications

Wireless Data Logger Monitoring Systems

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

DataView DVTH Data Logger for Temperature and Humidity

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

XP Series Balances Operation Manual

How To Use A Ds340 (Dsp)

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Sympodium Interactive Pen Display

Short Throw for Large Sceens from Small Distances

CalMaster2 Field and Software Tools. The world's first battery- and mains-powered in situ flow verification system

Data Sheet FUJITSU Display L27T-1 LED

MICROMAT-F / MINIMAT-F SCREWDRIVING SYSTEM

RFID Logger Software User Manual Rev 1.0

EW400. Plug and Play Projection. Native WXGA, 4000 ANSI Lumens. USB plug and play presenting. Up to 6000 hours lamp life and 70% energy saving

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MInIMAT-ec. flexible data recording highly accurate

TECHWRENCH November 30, 2005 TECHNICAL PAGE

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

4-Channel Thermometer / Datalogger

Transmitter Interface Program

Repeaters and Mimics Data Sheet

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Macintosh Portable. Overview

O C M III. Open Channel Flow Monitor

Impedance 50 (75 connectors via adapters)

User Guide. Temperature and Humidity Datalogger. Model 42280

Series DFMT Digital Paddlewheel Flowmeter

Uninterruptible Power Supply

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Bar Codes For Inventory

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Product Information Sheet UH28CS-12kV Hi Pot Tester

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

PIEZOMETER AIRFLOW MEASURING RING

EX400. Product, Compact Projection. Native XGA, 3700 ANSI Lumens. USB plug and play presenting. Up to 6000 hours lamp life and 70% energy saving

Main features * : Internal database > 1000 tests. Suprathreshold tests. High frequency. Musical frequencies. Automatic masking.

CONTROLTECH INDUSTRIAL TORQUE WRENCH

Datasheet: AirCheck Wi-Fi Tester

Digital Air Pressure Gauge Users Manual

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

User s Manual. Management Software for Inverter

SMART Podium Interactive Pen Display

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Agilent E6020B FTTx OTDR

1. SAFETY INFORMATION

3100 Lumens SVGA DLP (White) Projector PJD5155L

MagIC Installation Manual. Point of Sales Terminals TD06014B

OCSM Series. High Resolution Digital Crane Scale. User Guide

TurbiDirect TurbiCheck TurbiCheck WL

Data Sheet FUJITSU Display L27T-1 LED Display

Highly efficient flue gas analyzer

How to use your Capture Manager PC Software

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Physical Specifications (Custom design available.)

Data Sheet FUJITSU Display B24T-7 LED progreen

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

Accurate Measurement of the Mains Electricity Frequency

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

WXGA (1280 x 800), 3500 lumens, up to 7,000 hours lamp, HDMI, throw ratio, wireless ViewSync

Incubator with mechanical convection

Keywords: Torque, calibration, uncertainty, torque tools, torque testers. Contents

FREJA 300 Relay Testing System

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

GeoMax GNSS Zenith10 & Zenith20 Series

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

BASIC SOUND LEVEL METERS

Transcription:

Key Features Easy-read display with simultaneous display of all relevant information Tailored to your requirements from simple readout to comprehensive audit tool and more Communicates with your PC system Interchangeable transducer units with vertical or horizontal axis Software shared with TorqueStar Opta Product Overview DTT Opta introduces a world of choice, features and flexibility to the tool test environment, with interchangeable transducer modules, built-in printer option, and software features tailored to the application requirement. These options allow DTT Opta to be configured to closely match the user requirements, and a selection of transducer units can be made available to the operator to cover a broad torque range. Different transducer units are available with the transducer axis in either the vertical or horizontal plane. In common with the Opta product family, DTT Opta s range of software features can be individually specified giving variations from a simple no-frills readout to a comprehensive audit tool with display of torque curves and specialist measurement routines. As the software is common throughout the Opta product family, users familiar with TorqueStar Opta will already know how to use DTT Opta, and vice-versa. The basic DTT Opta performs bi-directional measurement of torque in track, peak, 1st peak (click) and pulse measurement modes, when pulse count is also measured. Cycle time duration can also be displayed. Time and date stamped readings can be set to print automatically on the external printer. The easy-read display gives a simultaneous view of all relevant information during the measurement process, while the simple alphanumeric keypad enables fast data entry when required. Specifications - DTT base unit Functional Attributes Special features Physical measurements Measurement units Measurement modes Upgradeable via enablement of software modules to add traces (torque vs time or 2 nd parameter; 2 nd parameter vs time), data storage, audit scheduling, and other options. Please refer to separate information sheets. Quick measure enabling measurements to be taken following a single key press. Auto return to previous used screen following power-on. Bi-directional torque; pulse count; cycle time duration N m, N cm, kg cm, kg m, kn m, Klb ft, MN m, N µm, N mm, oz in, lb in, lb ft Track real time torque Peak capture of highest torque value during the cycle Click-dip capture of instantaneous torque value as torque limiting wrench mechanism operates Pulse special measurement algorithm for use with impulse tools, incorporating pulse count

Plug & Play transducer data The following information is read from the UTA chip incorporated in the transducer device: Torque range, serial number, calibration due date PC compatibility Data storage Statistics Auto-print Cycle status indication Graphic analysis Operating language Via OptaComms PC communication software See comparison table See comparison table Switchable autoprint to optional built-in printer or compatible external printer Tri-colour LED HI/OK/LO torque status with appropriate upgrade module Audible buzzer Not available on basic model see available upgrades Czech; English; French; German; Italian; Polish; Spanish; Swedish Can toggle between languages at virtually all menu points without need to exit operating mode Physical Attributes Construction Display Keypad Frequency response (Hz) Power Battery pack Useable battery life Charge time Power management Input/output ports External printer compatibility Processor Zero stability Static accuracy Rugged aluminium case 62 x 62mm backlit graphic LCD display, 160 x 160 pixel resolution, with high quality optical screen protection, 4 digit display of torque value Easy clean membrane keypad with alphanumeric keys for ease of data entry A low pass frequency filter is employed for conditioning the transducer signal to eliminate noise from the tool measurement. This is user selectable from the following discrete values: 4608, 3072, 2304, 1536, 1316, 1024, 921, 768, 542, 384, 307, 256, 151, 75. Universal 15V charger Nickel Metal Hydride 8 hours* 16 hours User selectable auto power off: Never, 1, 2, 5, 10, 20, 30, 40, 60 minutes or 16 Hours 9 pin RS232 port (female) Serial 80 column printer, 9600 baud rate Hitachi embedded processor < ± 0.1% FSD/ C ± 1% FSD Operating environment Temperature: 5 40 C Humidity: 10 75% non-condensing Ingress protection rating: IP40 Designed for indoor use only Warranty 12 months parts and labour against faulty workmanship or materials Dimensions Complete unit: 255 x 255 x 79mm (10 3 8 x 10 3 8 x 3 1 8 ) Individual transducer unit: 105 x 85 x 79mm (4 1 8 x 3 3 8 x 3 1 8 ) Weights Shipping list DTT Opta without transducer or printer module: 3.5 Kg Transducer unit: 1.3 Kg Printer unit: 220 gms DTT Opta unit with basic operating software Basic storage and statistics module Charging unit with appropriate power cable for order code Carrying case * Backlight on, transducer connected, 50% duty cycle - no printer

Specifications - interchangeable transducer units Functional Attributes Special features Tool compatibility Physical measurements Plug & Play transducer data Physical Attributes Calibration Construction Zero stability Static accuracy Easily interchangeable modules available with transducer axis in vertical or horizontal plane. All torque tools, including impulse tools (not impact tools) Joint kit supplied with vertical axis transducers for use with continuous drive and impulse tools to represent joint conditions Bi-directional torque (clockwise calibration unless otherwise specified) The DTT base unit reads the following information from the UTA chip incorporated in the transducer device: Torque range, serial number, calibration due date Issued with calibration certificate traceable to National and International Standards. IS transducers are normalised calibration unless indicated in table. Standard Crane calibration: 10 points; single direction (clockwise unless otherwise requested); 10% to 100% of nominal torque. Bi-direction Crane calibration: 10 points; each direction; from 10% to 100% of nominal torque. UKAS calibration: calibration to BS 7882 Recalibration is recommended every 12 months Aluminium housing Overload capacity: 125% rated torque Square drives to ANSI B107-4 1982; BS4006 1992; DIN 3121 1987 < ± 0.1% FSD/ C ± 1% FSD Operating environment Temperature: 5 40 C Humidity: 10 15% non-condensing Ingress protection rating: IP40 Designed for indoor use only Warranty Shipping list 12 months parts and labour against faulty workmanship or materials Transducer unit Joint kit (vertical axis transducer units only).

Menu / Screen Examples DTT Opta

Comparison Table Data Storage and Statistics functionality available with upgrade module The basic storage and statistics module is included with the DTT base unit. For more information, please refer to the module product information leaflets. Function Basic Storage & Advanced Storage Statistics module & SPC module Upper and Lower Specification Limits Storage of up to 200 date and time stamped readings Basic statistical analysis average (mean), range, standard deviation (sigma) Audible and visual indication of torque status Assign cause and action flags to measurement Transducer serial number stored with measurement record (with subgroup) Serial printout of stored readings with set-up parameters and transducer serial number Predefined jobs with target torque and 2 nd parameter measurement Definable number of subgroups within job Definable number of readings within subgroup Organise jobs into rounds for audit scheduling Detailed statistical analysis per job and subgroup average (mean), range, standard deviation (sigma); Capability ratios Cp, Cpk, Cm, Cmk Serial printout of subgroup readings with set-up parameters and transducer serial number Job comment up to 30 characters (with/without prompt) Subgroup comment up to 30 characters (with/without prompt) Reference comment up to 30 characters (with/without prompt) Password protection for user and administrator Compatibility with OptaComms for data transfer between PC and Opta unit Single Included with DTT base unit Multiple NOTE: Advanced Storage module also requires Basic Storage module to be enabled. Therefore, Advanced Storage includes the Basic Storage module functions.

Order Codes Order Code Description DO-937-01CR-0-UK DTT Opta - UK charger DO-937-01CR-0-EUR - European charger DO-937-01CR-0-US - US charger DO-938-02CR-0-0 Printer module with paper roll Order code Drive Nominal Torque Axis orientation Joint kit Nm Imperial (ftlbf) DO-939-01CR-1-0 1/ 4 Sq 1 8.8 inlbf Horizontal DO-939-02CR-1-0 1 / 4 Sq 1 8.8 inlbf Vertical DO-940-01CR-4-0 1 / 4 Sq 4 11 inlbf Horizontal DO-940-02CR-4-0 1 / 4 Sq 4 11 inlbf Vertical DO-941-01CR-12-0 1 / 4 Sq 12 8.8 Horizontal DO-941-02CR-12-0 1 / 4 Sq 12 8.8 Vertical DO-942-01CR-30-0 3 / 8 Sq 30 22.1 Horizontal DO-942-02CR-30-0 3 / 8 Sq 30 22.1 Vertical Accessories List Item Description Order code DTT Opta to PC cable* Connection cable to PC for OptaComms connection CBL-757-0-0-0-0 DTT Opta to printer cable* Connection cable to printer for auto-print functions CBL-758-0-0-0-0 OptaComms Enablement of individual Opta unit for PC communication, together with Comms software CD OM-900-01CR-0-0 Opta upgrade modules Bottle top fixture (Adjustable component fixture) Software modules to enhance product features. Note: return to Crane not required. See separate details Adjustable component fixture for clamp and test of individual items e.g. bottle tops, key locks etc. 3 / 8 drive DO-960-01CR-4-0 1 / 4 drive DO-960-01CR-30-0 Spare paper roll Paper roll for printer module A1 110047 Spare ink ribbon Ink ribbon for printer A1 110048 Spare joint kit 1Nm Replacement/spare joint kit W1 220887-01 Spare joint kit 4Nm Replacement/spare joint kit W1 220887-02 Spare joint kit 12Nm Replacement/spare joint kit W1 220887-03 Spare joint kit 30Nm Replacement/spare joint kit W1 220887-04 *Included free of charge if any Opta software modules are bought at the same time as the base unit. Can grip items from 10 130mm

Notes