ABSTRACT ELEMENTS OF THE LOCAL AREA NETWORK

Similar documents
Network Design. Yiannos Mylonas

Universal Network Access Policy

Cisco SLM248P 48-Port 10/ Port Gigabit Smart Switch: SFPs/PoE

EGS7228P. Business Class EGS7228P. 24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW

Layer 3 Network + Dedicated Internet Connectivity

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W

DCRS-5650 Dual Stack Ethernet Switch Datasheet

Cisco Small Business Managed Switches

Cisco EtherSwitch Network Modules

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY MATERIALS MANAGEMENT DIVISION : (+91 22) (DR)

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

CompTIA Network+ (Exam N10-005)

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example

Ten top problems network techs encounter

COMPUTER NETWORK TECHNOLOGY (40)

Cisco Small Business Smart Switches

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

Cisco SFE1000P 8-Port 10/100 Ethernet Switch: PoE/Fanless Cisco Small Business Managed Switches

Cisco Small Business Managed Switches

Data and Voice Network Infrastructure

How To Make Power Over Ethernet A Viable Alternative To A Network Cable (Networking)

EX 3500 ETHERNET SWITCH

AT-S63 and AT-S63 NE Version Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Going Critical. How to Design Advanced Security Networks for the Nation s Infrastructure. w w w. G a r r e t t C o m. C o m

ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch

21 st Century Campus Network Responsibility Matrix 5/26/10

20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

ANNEX III BUDGET PROPOSAL AS PER LOTS LOT 1

Cisco SPS208G 8-Port 10/ Port Gigabit SP Switch Cisco Small Business Gigabit SP Switches

TP-LINK. 48-Port Gigabit Smart Switch with 4 SFP Slots. Overview. Datasheet T1600G-52TS (TL-SG2452)

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

July, Figure 1. Intuitive, user-friendly web-based (HTML) interface.

How To Install An At-S100 (Geo) On A Network Card (Geoswitch)

High Performance 10Gigabit Ethernet Switch

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES-8-150W, ES W, ES W, ES W, ES W, ES W

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. Slide Number 1

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL

UW CAMPUS SITE CONFIGURATION STANDARDS

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES W, ES W, ES W, ES W

DCS CT-POE fully loaded AT PoE Switch Datasheet

Unlock the Power of Ethernet Delivering 100 Mbps and PoE over CAT3 and Legacy Copper with ADTRAN ActivReach

Transformation of the Enterprise Network Using Passive Optical LAN

SSVVP SIP School VVoIP Professional Certification

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P.

HARTING Ha-VIS Management Software

TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG

EtherDevice Switch EDS-726 Series

TP-LINK L2 Managed Switch

20 GE + 4 GE Combo SFP G Slots L3 Managed Stackable Switch

DCS C Fast Ethernet Intelligent Access Switch Datasheet

Ethernet Link SGI-2424

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E.

Datasheet. Managed Gigabit Fiber Switch. Model: ES-12F. Non-Blocking Throughput Switching. High Performance and Low Latency

RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket

CABLING REQUIREMENTS:

Ethernet Link POE-G4804M 44-Port 10/100/1000Base-TX + 4 Combo TP/SFP (100M/1G) PoE+ Layer 2 Plus Managed Gigabit Ethernet Switch

John Ragan Director of Product Management. Billy Wise Communications Specialist

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Chapter 4 Connecting to the Internet through an ISP

Apple Airport Extreme Base Station V4.0.8 Firmware: Version 5.4

IPTV over Fiber Optics for CPE Installers

Datasheet. Managed Gigabit Switches with SFP. Models: ES-24-Lite, ES-48-Lite. Non-Blocking Throughput Switching Performance

Computer Networking Networks

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

PLANNING & IMPLEMENTING VOICE over IP

Networking 4 Voice and Video over IP (VVoIP)

784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV ) (FA ) (7-12)

2015 Piqua City Schools RFP for Network Equipment under E-Rate Category 2

Juniper / Cisco Interoperability Tests. August 2014

Technology Solution Guide. Deploying Omnitron PoE Media Converters with Aruba Access Points and AirMesh Routers

TP-LINK 24-Port Gigabit L2 Managed Switch with 4 SFP Slots

CHAPTER 6 DESIGNING A NETWORK TOPOLOGY

Cisco WAP4410N Wireless-N Access Point: PoE/Advanced Security Cisco Small Business Access Points

Chapter 3. Enterprise Campus Network Design

COBRA Power over Ethernet Products for IP Surveillance Applications LAN POWER SYSTEMS. Trend Datacom USA, Inc.

Voice Over IP. MultiFlow IP Phone # 3071 Subnet # Subnet Mask IP address Telephone.

Understand VLANs, Wired LANs, and Wireless LANs

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch TL-SL5428E

Cisco WAP4410N Wireless-N Access Point: PoE/Advanced Security. Cisco Small Business Access Points

Development of the FITELnet-G20 Metro Edge Router

AT-S63 Version Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes

ARCHITECTURAL PARTNERS, P.C. 10 Ninth Street, Lynchburg, Va / Fax 434/

Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family

UW MEDICINE SITE CONFIGURATION STANDARDS Overview

Network System Design Lesson Objectives

SSVP SIP School VoIP Professional Certification

Legal Services Corporation Technology Initiative Grant (TIG) Conference

PRODUCT DETAILS 3Com Switch 4500 Family 1 de 9 03/03/2008 9:43

IT-AD08: ADD ON DIPLOMA IN COMPUTER NETWORK DESIGN AND INSTALLATION

TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P.

Data Networking and Architecture. Delegates should have some basic knowledge of Internet Protocol and Data Networking principles.

AT-S62 and AT-S62 NE Version Management Software for AT-8500 Series Switches Software Release Notes

Aruba Mobility Access Switch and Arista 7050S INTEROPERABILITY TEST RESULTS:

Transcription:

ABSTRACT This document examines the elements of the local area network: vertical distribution cabling, horizontal distribution cabling, and access devices. It discusses their relationship to the University of Michigan backbone network, and their separate impacts on network performance. It considers the costs associated with upgrading each element in general terms, and indicates areas where tradeoffs may be made. It includes a limited discussion of design considerations for specific applications (such as voice over internet protocol, or VoIP). This document is not intended to be a complete and detailed engineering guide for local area network design. Rather, it is intended to be an overview of the various components of the network, their impact on network performance, and the issues to be considered when contemplating LAN installations or upgrades ELEMENTS OF THE LOCAL AREA NETWORK The Local Area Network (LAN) refers to the system of electronic devices and cabling that connects individual hosts (computers, printers, etc.) in a unit to each other and to the University of Michigan backbone network. The backbone network in turn provides connections to other hosts within the University, and to the internet. The Distribution Layer Switches are the physical presence of the backbone network in each building. They are connected to two different backbone switch-routers so that the failure of a single distribution layer switch will not cause the failure of the backbone network connection to the building. Vertical Distribution Cabling provides connections between the backbone distribution layer switches and local wiring closets. Vertical distribution cabling may be fiber optics (preferred) or any of several types of copper cabling. Access Layer Switches are provided by individual units. They are typically located in wiring closets and are connected to the distribution layer switches via the vertical distribution cabling. They provide network connectivity to the hosts in their area. Other devices, such as uninterruptible power supplies or power over ethernet devices may be associated with the access layer switches for particular applications. Horizontal Distribution Cabling provides connections between the access layer devices and the local hosts. It typically terminates at a patch panel in the wiring closet at one end, and at the wall jack in offices and classrooms at the other end. Various types of patch cables and drop cables are used to complete the connections to the access layer switch and the local host, respectively. Elements of the building s infrastructure, such as raceways (cable trays and conduits), wiring closet ventilation, and electrical power affect the functioning of all of these elements and may constrain your design. 3/24/2006 1

HORIZONTAL DISTRIBUTION CABLING The horizontal distribution cabling may limit the maximum data rate available to individual hosts. It is typically very expensive to upgrade and should be considered a long-term investment. When horizontal distribution cabling is upgraded, raceways may also need replacement as well. The types of horizontal distribution cable commonly found in University of Michigan buildings, and their data-rate capabilities, are: Category 5e is the current recommended type for new cabling. Installed according to specifications, this cable type will support data rates up to 1 gigabit per second. Category 5 was the recommended standard until fairly recently. It will support data rates up to 100 megabits per second. Most category 5 cable can be re-terminated according to category 5e specifications to support 1 gigabit per second. Category 4 cable is relatively uncommon. It will support data rates of no more than 10 megabits per second. Category 3 cable is still quite common, especially in buildings that have not been renovated within the past 20 years. It too will support data rates of no more than 10 megabits per second. Both the cable and its terminations must be compliant with the standards in order to work at the listed data rates. This is not the case in every University building, depending on the policies in effect at the time the building was wired. Category 5 cable, for instance, may be terminated to category three specifications in order to provide two 10 Mb/s ethernet circuits per cable. Current wiring standards call for TIA 568B terminations (all four pairs terminated) to support data rates up to 1 Gb/s. Horizontal distribution cabling may be no longer than 100 meters, measured from the access layer device to the host, including all patch cables and drop cables. It is important to note that this distance is the length of the cable, not the line of sight distance from the wiring closet. For practical purposes this means that the cable installed in the walls, i.e. between the patch panel and the wall plate, may be no longer than 90 meters. New buildings are designed with this standard in mind, but older buildings might exceed it. Although this distance standard has been part of the ethernet over twisted pair (ETP) standard from the beginning, older hubs and repeaters have been more tolerant of out of specification cabling than modern switches are. If you suspect that this condition may apply in your building the longest cable runs should be measured electronically to determine whether they are within specification. If they are not your alternatives are to construct new wiring closets and rewire the out-of-spec locations to the new closets, install proprietary ethernet technology for long distance wiring, or install wireless ethernet. Each of these options has unique costs, performance tradeoffs, and 3/24/2006 2

infrastructure requirements, a complete discussion of which is beyond the scope of this document. ACCESS LAYER DEVICES The access layer devices typically have the shortest service life of all of the LAN elements discussed here, and they are the most easily replaced. We recommend that all access layer devices provide a minimum set of capabilities, but you may forgo more advanced capabilities with small penalty if you are facing budgetary constraints. Nearly all currently available access switches provide connectivity to the hosts at either 10 or 100 megabits per second. The data rate used is automatically negotiated between the switch and the attached host. If you have category 3 or category 4 horizontal distribution cabling it will not operate properly at 100 megabits per second. In this case you will have to configure your access layer switches to operate at 10 megabits per second only. RECOMMENDED MINIMUM STANDARDS FOR ACCESS LAYER DEVICES Use managed switches, never hubs Provide one switch port per host (avoid small hubs and switches in offices) Remote management over the ethernet network, including SNMP V2 Available secure management interface, such as Secure Shell (ssh) (ssh-v2 or higher preferred, using encryption better than DES) IEEE 802.1Q/p VLAN support Support for standard spanning tree (STP-802.1d), rapid configuring spanning tree (STP 802.1w), multiple instance spanning tree (MISTP-802.1s) IGMP (V2) snooping (for multicast applications, such as video on demand). IGMP V3 is becoming more widely supported, and offers more robust multicast capabilities.) SUGGESTED ADVANCED CAPABILITIES FOR ACCESS SWITCHES Support for IEEE 802.1x to provide network level authentication. IEEE 802.1x with dynamic VLAN assignment to support Policy Based Networking. Four layer 2 priority queues (for VoIP installations, and for streaming video applications.) Ability to rewrite layer 3 type of service (TOS) or DifServ code point (DSCP) for ports. Ability to rate-limit traffic by type (unicast, multicast, broadcast) Power over ethernet (PoE) to support VoIP telephones and wireless access points. Add-on devices are also available and are equally satisfactory. The IEEE 802.3af standard is gaining acceptance; but incompatible devices still exist on campus and in the marketplace, so careful selection of compatible power sources and end devices is necessary. Support for IEEE 802.1t spanning tree enhancements 3/24/2006 3

Per VLAN spanning tree (PVST) DHCP relay (with support for option 82, switch port mapping.) Link aggregation (IEEE 802.3ad) for higher uplink bandwidths. Radius and/or TACACS+ authentication for management access. SNMP V3 management for higher security environments Netflow/sflow export Syslog logging capability. DHCP snooping, IP source verification, and dynamic ARP inspection to prevent various man in the middle attacks. RELIABILITY CONSIDERATIONS If your network will be used for voice services over internet protocol (voice over IP, or VoIP) you should insure the highest possible reliability, because the voice telephone is usually peoples first recourse in an emergency. Uninterruptible Power Supplies (UPS) are essential for VoIP. You may also consider them for switches connected to departmental servers, to allow time for graceful shut down in the event of power failure. If you have wireless access points connected to your switches you may also want to consider UPS, since wireless users will typically be using battery powered laptop computers. (This assumes that the wireless access points will also be powered from an uninterruptible source, such as a PoE device connected to the UPS.) New construction projects often include a diesel or gas generator to provide power to emergency circuits. For critical applications, such as VoIP, it may be possible for this generator to provide power for network switches as well, reducing the size and cost of the UPS required. This option should be discussed with the architects and facilities planners early in the construction planning process. Redundant power supplies are available for large chassis-based switches. Since power supply failure is perhaps the most common failure mode this can be a significant enhancement to reliability. Dual homing to the distribution layer switches involves connecting each access switch to both distribution layer switches, insuring continued connectivity in the case of a distribution switch failure. Particularly if you are using stacked switches, connecting the first and last switches in the stack to different distribution layer switches will prevent failure of a single switch in the stack from interrupting connectivity to the remaining switches. You may need to upgrade the vertical distribution cabling to achieve dual homing. WIRING CLOSET CONSIDERATIONS Wiring closets in older buildings are often small and unventilated. Fortunately manufacturers are aware of the prevalence of these conditions and good quality switches 3/24/2006 4

are surprisingly robust. Forced air ventilation or mechanical cooling is desirable but may not be necessary if the heat load is small. Louvers inserted into wiring closet doors will sometimes provide sufficient ventilation in marginal situations. (Alterations to wiring closets must conform to code requirements for fire and smoke protection. Check with the Fire Marshall before proceeding.) Avoid storage of ladders, custodial supplies, salt, corrosives, flammables, etc. in wiring closets. If you are in a high security environment access control for wiring closets should be part of your security design. VERTICAL DISTRIBUTION CABLING The data from all of the hosts connected to an access layer device is transmitted to the campus backbone network via the vertical distribution cabling. For this reason, inadequate vertical distribution cabling can have a significant effect on your network s performance. Fortunately it is often possible to upgrade the vertical distribution cabling at a reasonable cost. If you are installing new vertical distribution cabling you should install enough to support dual homing (see above), since the extra material cost is usually only a small part of the total cost. Various types of vertical distribution cabling are commonly encountered at the University: Fiber optic cable (recommended) is capable of the highest data rates. Multi mode fiber is usually adequate for connections wholly with the building, whereas single mode fiber is required for longer distances. It seems likely that future high data rates will require single mode fiber. We recommend that both types be installed. Category 5e, 5, 4, or 3 tie cables are subject to the data rate limitations discussed above under horizontal distribution cabling. Telephone riser cable was commonly used for early ethernet installations. This cable is will support at best 10 megabits per second, deteriorating over time. This cable type is not replaced, because it is also used for voice telephony. New vertical distribution cabling for ethernet networks should be installed in parallel with the existing telephone riser. New raceways may be required, but usually are not. REFERENCES GUIDELINES FOR NEW CONSTRUCTION The University of Michigan s Plant Extension department publishes extensive guidelines for new building construction. The section relevant to telecommunications building entrance and raceway may be found at: http://www.plantext.bf.umich.edu/desguide/tech/16/16740.pdf the section referring to wiring closet design is at: http://www.plantext.bf.umich.edu/desguide/sba/sba_c.pdf 3/24/2006 5

THE UNIVERSITY OF MICHIGAN BACKBONE NETWORK The backbone network consists of six switch/routers connected in a partial mesh and located in various buildings around campus. These switch/routers provide VLAN connectivity between buildings and layer 3 interconnectivity for the entire campus. They are in turn connected to the other backbone networks on campus and to the public internet and Internet II via MERIT/MichNET. The distribution layer switches in each building provide connectivity between the building LANs and the backbone core. 3/24/2006 6

University of Michigan Backbone Network Conceptual Diagram 3/24/2006 7