Certified Residential Energy Auditor (REA) Study Guide



Similar documents
Certified Energy Auditor Study Guide

Fuel and Energy Conversion and Equivalence Chart

ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates

Energy Depot for Business Energy Audit Question Set

Energy-Efficient. Home. Tips for Purchasing an. Revised Use this brochure to answer these questions:

APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1

Commercial Energy Savings Guide.

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Connecticut Energy Efficiency Fund Home Performance Program Application (Tier II)

Comparing Fuel Costs of Heating and Cooling Systems

Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri

Sustainable Design and Energy-Efficient Building Techniques for Existing Housing

Glossary of Heating, Ventilation and Air Conditioning Terms

Direct Energy Home Energy Audit Audit Report

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS

Saving Heating Costs In Warehouses

Category Measure Minimum Efficiency / Certification Requirements

New Jersey Home Performance with ENERGY STAR

Residential HVAC System Sizing

Differentiating Energy Modeling Software!

2014 British Columbia Building Code Changes

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

Below are detailed instructions for using the EMS load calculator.

Current Programs available to Limited Income Customers. Residential and Multifamily

Heat Pumps for Cold Climates?? Yes, Indeed!

Creating Efficient HVAC Systems

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

APPENDIX 2. Summary Report: Heating and Cooling Energy Adjustment for HUD Spreadsheet Model

Selecting a Home Heating System

PENNSYLVANIA GREEN ENERGY LOAN FUND

Commercial Energy Efficiency Program. Save money, reduce energy use and earn incentives. Save money, reduce energy use and qualify for incentives

Alternatives for the Residential Energy Consumption Baseline

Residential Buildings Energy Code Summary

Contract for Weatherization Management Address City & State

Home Performance with ENERGY STAR

Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows

NORTH CAROLINA INCENTIVES

Energy Efficiency for the Homeowner

Sample DTE Energy Rebate Programs Follow:

EarthCents (DSM) Program Summary

California HERO Program Residential Eligible Product List

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

Residential Construction

FLORIDA SOLAR ENERGY CENTER

Building Energy Analysis Report

COMPREHENSIVE 5-DAY TRAINING PROGRAM FOR ENERGY MANAGERS / SEMINAR OUTLINE

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Heating & Cooling Efficiency

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

White paper on the comparative energy efficiency of zoned electric heaters Convectair, Inc. / Convectair-NMT Inc. September 2004

Xcel Energy s Commercial Industrial Energy Efficiency Programs. Overview of Colorado Business Rebate Programs

energy-saving checklist a guide for rental property owners

Smart Ideas(R) Energy Efficiency Program for ComEd Customers

Energy Efficiency Evaluation Report File number: EEC.hdf

Energy and Cost Savings

Measuring Energy Savings and Cost Effectiveness - A Real Case Study

Advancing Residential Energy Retrofits

Indiana Energy and Cost Savings

Mortgage Industry National Home Energy Rating Systems Standards

Energy Savings with Window Retrofits

First Time Home Buyers Energy Efficiency Workshop Guide

Colorado Energy and Cost Savings

RBSA/Seattle Multi-family Characterization

EPA WaterSense for New Homes Program DOE Zero Energy Ready Home Quality Management Guidelines

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

A Guide for Contractors as the Deadline Approaches

New Homes EPS Modeling Frequently Asked Questions. Developed by Energy Trust of Oregon

Energy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Q&A on Tax Credits for Sections 25C and 25D. Notice SECTION 1. PURPOSE

Sample Customer 123 Conservation Way TAMPA FL Tracking Number:

New Jersey BPU Energy Audits CHA #19860 Building: Kingwood Township School

Xcel Business Customers: Program and Rebate Summary

Existing Housing Stock

Energy Efficiency Improvements in New & Existing Homes

Idaho Energy and Cost Savings

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

Georgia Energy and Cost Savings

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Introduction to Energy Codes & Green Building Programs

BUILDING SAFETY UNIT

How To Test A Building For An Icc 2006 Test Case

Table of Contents. Page ii

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

Energy Assessment Questionnaire

Air-Conditioning Buying Guide

Home Energy Efficiency and Conservation: Call to Action. July 23, 2015 Dave Blake and David Wood REEP Green Solutions

It Pays. To Save Energy FPO. Guide to Xcel Energy rebates, incentives and programs for residential customers in Minnesota

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Analysis of HERS Index Scores for Recent Versions of the International Energy Conservation Code (IECC)

Mr. Joe Contractor [Company Name] 123 Contractor Road Hardworkintown, AL Dear Mr. Contractor,

2013 BUILDING ENERGY EFFICIENCY STANDARDS

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

HOME ENERGY AUDIT REPORT

Enclosing Timber Frames. Panels. Frank Baker Founder, Riverbend Timber Framing and Insulspan

Green Heat Pre-Approval Application

Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V Water II Heat Recovery VRF System)

Understanding Heating Seasonal Performance Factors for Heat Pumps

Energy Saving Opportunities for Businesses. Presented by Anna Selgert, Outreach Representative

Transcription:

Certified Residential Energy Auditor (REA) Study Guide This guide provides an overview of the Certified Residential Energy Auditor (REA) Program, including how to register for the REA Training Seminar and apply for the REA Examination. It includes an outline of the Seminar topics and example questions similar to ones on the REA Examination. - REA Objectives - REA Eligibility - REA Examination - Seminar Overview and Course Outline - REA Certification/Examination Application - Example Questions with Answer Key - Preparation - Additional Information Resources

The Residential Energy Auditor (REA) certification was developed and added to the Association of Energy Engineers portfolio of certifications to provide residential energy auditors and those in related professions with a fundamental understanding of residential energy use and opportunities for energy savings. Rising energy costs and increased interest in the environmental impacts of energy use have increased the demand for trained and experienced residential energy auditors. The REA certification identifies residential energy professionals as having the knowledge and experience needed to succeed in the growing field of residential energy auditing. REA Objectives The REA Certification Program is intended to improve the practice of residential energy auditing via continuing education and professional development, and to identify individuals who demonstrate appropriate knowledge of the principles and practices of residential energy auditing via the completion of an examination and fulfillment of prescribed standards of performance and conduct. By earning the right to put the initials "REA" behind your name, you have distinguished yourself as a professional who has demonstrated a high level of competence in the residential energy auditing field. REA Eligibility The candidate for CEA certification must have: A two-year technical degree or higher in engineering, building management, energy auditing, construction management, science, or a related specialty. No prior specific experience in residential energy auditing is required; - OR - The status of U.S. military veteran with at least three years of verifiable relevant technical experience. No prior specific experience in residential energy auditing is required; - OR - The current status of Certified Energy Manager (CEM) or Certified Energy Auditor (CEA) in good standing. Note: Candidates who have significant experience in performing residential energy audits but lack the requirements listed above will be considered on a case-by-case basis. Resumes or other documentation of experience should be submitted to the Director of Certification.

The REA Examination All REA candidates must attend one of AEE's preparatory REA training seminars, and complete and pass the four-hour written REA examination, proctored by an AEE-approved exam administrator. REA examination questions are drawn from concepts and experiences basic to residential energy auditing methodology, home energy use, residential energy systems, energy conservation measures, energy calculations, and diagnostic and software tools. The four hour examination is open book, and questions are a combination of multiple choice and true/false. Roughly half of the questions involve some type of energy calculation. A passing score of at least 70% is required in conjunction with meeting all other eligibility requirements to become certified. Examinations are graded by AEE s Director of Certification and are identified by number rather than by candidate name to assure confidentiality and objective grading. The Certification Director keeps examination scores on file for a period of three years. Applicants who do not receive certification status can request that their applications be resubmitted to the CEA Board, if during that three-year period their education or experience level changes. Fundamentals of Residential Energy Auditing Seminar This 3-day program is designed to provide the specific training needed by professionals preparing to sit for AEE s Residential Energy Auditor (REA) certification exam. The program covers all major aspects of home energy use, residential energy systems and technologies, energy conservation measures (ECMs), energy auditing methodology and calculations, and diagnostic and software tools. The course material assumes no prior knowledge of the topic and incorporates all the basic information residential energy auditors need. For those wishing to qualify for the REA certification, the REA examination will be administered on the morning of the day following the seminar to pre-qualified applicants. Certification Please Note: In order to qualify to sit for the REA exam, you must submit your completed REA application, along with a $300 application fee. For information on obtaining your REA application form, or for further information on the REA program, visit www.aeecenter.org/certification. Basic Skills Required for this Seminar Although the REA certification is not highly technical, there are a number of equations and calculations utilized in the seminar that are essential to understanding the basic principles of residential energy auditing. Those needing a refresher program covering effective use of a hand calculator and use of equations may wish to consider participating in the Basics of Energy Management online seminar prior to taking this course. For information, visit www.aeecenter.org/training.

Seminar Outline Introduction / Objectives Energy Basics Utility Billing "Base" vs. "seasonal" energy use Estimating space heating/cooling energy use from bill data Principles of Heat Transfer Introduction / basic principles Conduction / convection (infiltration) / radiant Heating Degree Days Heat transfer calculations Residential Energy Overview Typical consumption by end-use Factors affecting residential energy consumption Building Envelope Defining the envelope Areas of conductive losses/gains Radiant heat gains Sources of infiltration Building envelope ECMs (Energy Conservation Measures) Indoor air quality Calculating energy and cost savings Space Heating Factors affecting space conditioning energy use Electric space heating systems Fossil fuel heating systems Space heating calculations and ECMs Air Conditioning Vapor compression cycle and components System types/configurations Efficiency ratings Air conditioning calculations and ECMs Water Heating Factors in water heating energy use Electric / gas / other water heating systems Water heating energy calculations Water heating ECMs Lighting and Appliances Lighting efficiency Lighting energy calculations Lighting ECMs

Residential appliances Efficient appliances / Energy Star Financial Calculations / Tax Credits Simple payback calculations Federal tax credits for qualifying ECMs Residential Energy Audit Overview Types of residential energy audits Home Energy Ratings / Energy Star / LEED for residential buildings Conducting a Residential Energy Audit Preparation Observations / what to look for Measurements / calculations Diagnostic tools / instruments Presenting recommendations Certified Residential Energy Auditor (REA) Program & Exam Application Please note: In addition to completing and submitting the seminar registration, in order to take the REA exam, applicants must also complete the REA Certification online application REA Certification Online Application: https://www.aeecenter.org/custom/certifications/form.cfm?form_id=21 The REA exam is administered at each Fundamentals of Residential Energy Auditing seminar site, on the morning following the last day of the seminar. Notification of Exam Results Within thirty days of the date of the exam, you will be notified of your score. Your application fee must be paid before your score can be released. Please do not call AEE about your test results before the end of the thirty-day period. Exam results are not available on the AEE website. Review by Certification Board: If you receive a passing score and have paid the examination fee, and if your file is complete, including all supporting documents, your file will be sent to the Certification Board for final review. You will be notified at that time that you will receive the Board's approval or denial within sixty days.

REA Examination - Sample Questions 1. 1 million British Thermal Units are equal to a. 1 MBtu b. 10 Therms c. 10 MMBtu d. None of the above 2. What percent of the radiant heat gain though a window will be blocked by installing a tinted film or solar screen with a Solar Heat Gain Coefficient of 0.35? a. 35% b. 3.5% c. 65% d. It depends on the U-value of the window 3. If an Energy Conservation Measure will save 1 MMBtu/year in space heating energy and the home is heated by an 80% efficient natural gas furnace, what will be the annual savings in Therms? a. 12.5 Therms b. 125 Therms c. 100 Therms d. 10 Therms 4. How much heat can an air-source heat pump with an HSPF of 6.8 provide for each kwh? a. 6.8 Btu b. 6.8 MMBtu c. 6800 Btu d. it depends on the size of the heat pump 5. When checking insulation in an attic, it is also important to check for a. Adequate ventilation b. Pipe and wire penetrations through the ceiling c. Signs of excessive moisture d. All of the above

6. A 10,000 Btu/hr window air conditioner draws 1.25 kw of power what is its EER? a. 8.0 b. 10.0 c. 12.5 d. None of the above 7. Which would have the greater potential heat content - five gallons of propane or four Therms of natural? a. The natural gas b. The propane c. They are equal d. It depends on the heating system efficiency 8. A customer has an estimated annual water heating cost of $480. What would be the annual energy cost savings for replacing the existing electric water heater (0.88 Energy Factor) with a new high-efficiency water heater (0.93 Energy Factor)? a. $25.81 b. $33.60 c. $57.60 d. It depends on the cost per kwh 9. What would be the annual energy cost savings for replacing four 60W incandescent lamps with 13W compact fluorescents (assume 8 hr./day and $0.13/kWh)? a. $19.73 b. $91.10 c. $71.36 d. None of the above 10. What would be the annual heating energy savings for reducing the air change rate from 1.0 ACH to 0.6 ACH in a 1,500 sq. ft. home with 8 ceilings in a location with 2800 HDD? a. 64.5 MBtu b. 6.45 MMBtu c. 645 Therms d. None of the above

Answer Key: 1- B 2- C 3- A 4- C 5- D 6- A 7- B 8- A 9- C 10- B Preparation The REA Seminar does not require any prior training. However, if attendees have previously had training in topics like heat transfer, residential heating and cooling load calculations or other related topics, it would be helpful to review that material before attending the Seminar. Although the Seminar does not involve any advanced engineering calculations, there are quite a few basic calculations that require familiarity with a calculator and basic mathematics. Some familiarity with basic algebra would be helpful, but not necessarily required. Examples of Calculations Used in the Seminar The following examples are typical of the types of calculations covered in the Seminar. Each example shows a step-by-step solution (but keep in mind that there is usually more than one way to arrive at the correct answer). Example 1: Calculate the BTU/hr. input required to deliver 60,000 BTU/hr. output with an 80% efficient gas furnace... When calculating input based on output, we divide by the system efficiency 60,000/.80 = 75,000 BTU/hr.

Calculate the BTU/hr. that can be delivered by a 75% efficient gas boiler with an input rating of 80,000 BTU/hr. When calculating output based on input, we multiply by the system efficiency 80,000 *.75 = 60,000 BTUH* *BTUH is a common abbreviation for BTU/hr. Example 2: A home has a calculated heat loss of 68,000 BTU/hr. at an indoor/outdoor temperature difference of 40 degrees. By how much would the heat loss be reduced for each degree of thermostat setback? Since heat transfer is directly proportional to temperature difference, we can simply divide the calculated heat loss by the temperature difference to get the heat loss per degree of temperature difference 68,000 BTUH / 40 degrees = 1700 BTUH per degree OR 2.5 % per degree Example 3: Calculate the cooling energy savings in BTU/hr. for increasing the R-value of a ceiling from R-11 to R-30 Area = 1500 sq. ft. Indoor temperature 75 degrees Attic temperature 120 degrees Using the conduction heat transfer equation first calculate the heat gain with R-11 Q = (Area * T ) / R-value Q1 = (1500 * (120 75)) / 11 = 6136 BTU/hr. Then calculate the heat gain with R-30 Q2 = (1500 * (120 75)) / 30 = 2250 BTU/hr. Then subtract to get the savings Savings = 6136 2250 = 3886 BTU/hr.

Example 4: Calculate the heating energy savings in BTU/hr. for reducing a home s ACH from 1.0 to 0.6 Volume = 12,000 cu. ft. Indoor temp. 70 degrees; outdoor temp. 20 degrees Use.02 for HC Using the equation for infiltration heat transfer, calculate the heat loss with 1.0 ACH, then calculate the heat loss with 0.6 ACH, and subtract to get the savings Q = Volume * ACH * T * HC Q1 = 12,000 * 1.0 * (70 20) *.02 = 12,000 BTU/hr. Q2 = 12,000 * 0.6 * (70 20) *.02 = 7,200 BTU/hr. Savings = (12,000 7,200) = 4,800 BTU/hr. Alternate method: Since the only value that changes is the ACH, we can calculate the savings in one step by using the difference in ACH ( ACH) Q= 12,000 * 0.4 * (70 20) *.02 = 4,800 BTU/hr. Example 5: An exterior frame wall has R-13 cavity insulation plus one inch of rigid foam sheathing (R-5). Assuming that 20% of the wall area is framing with an R-Value of 3, what is the overall R-Value of the wall? To account for the effect of the framing, we calculate a weighted average of the R-Values of the cavity insulation and of the framing; then add the R-Value of the sheathing which covers the entire area R = (13 *.8) + (3 *.2) + 5 R = 10.4 +.6 + 5 = 16

Example 6: Calculate the cost per million BTU for an 80% efficient gas furnace at a rate of $.89/Therm (1 Therm = 100,000 BTU) Divide the million BTUs by the fuel factor (100,000 BTU/Therm) times the efficiency to get the Therms 1,000,000 / (100,000 *.80) = 12.5 Therms Then multiply by the cost per Therm to get the cost per million BTUs 12.5 Therms * $.89/Therm = $11.13 Example 7: A home with electric baseboard heating has an annual space heating cost of $1800. What would be the estimated annual heating cost with a heat pump with an average COP of 2.5? Since the baseboard heating is 100% efficient (COP = 1.0), we can simply divide the annual cost with the baseboard heating by the average COP of the heat pump to get the estimated annual heating cost with the heat pump Annual Cost (Heat Pump) = $1800 / 2.5 = $720 Additional Information Resources: U.S. Depart of Energy: http://www.eere.energy.gov U.S. EPA Energy Star: http://www.energystar.gov/index.cfm?c=assess_performance.conduct_assessments State Energy Offices http://apps1.eere.energy.gov/state_energy_program/seo_contacts.cfm AEE Certification Programs http://www.aeecenter.org/certification Real-time online seminars http://www.aeecenter.org/realtime Professional Reference Books http://www.aeecenter.org/books Technical Papers on Energy / Energy Auditing http://aeecenter.metapress.com