THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION.

Similar documents
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

COMMONLY USED RESIDENTIAL BUILDING CODES


I N T E R N A T I O N A L R E S I D E N T I A L CO D E

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Residential Decks. Planning and Development Services Department

Number of Sides Required to Have a Handrail

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Walking and Working Surface Checklist:

ACCESS AUDIT OF WESTPORT HOUSE

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

Access to and use of buildings

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP

CITY OF TORONTO. BY-LAW No

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014

New York City Department of Buildings

Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

AUSTRALIAN HUMAN RIGHTS COMMISSION NOTICE OF DECISION ON APPLICATION FOR TEMPORARY EXEMPTIONS: AUSTRALASIAN RAILWAY ASSOCIATION

Extracts from BUILDING REGULATIONS

Simplified Steel Stair Design for Commercial and Institutional Buildings

BUILDING REGULATIONS GUIDANCE NOTE NHBC BUILDING CONTROL

St. Michael s Hospital Accessibility Plan

Common ADA Errors and Omissions in New Construction and Alterations

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

BUILDING REGULATIONS PART M 2004 ACCESS TO AND USE OF BUILDINGS. Designers Checklist of Provisions/Areas for Consideration.

ADA Checklist for Polling Places

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Building Regulations (Northern Ireland) Department of Finance and Personnel protection from impact.

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

New York City Department of Buildings

Residential Deck Safety, Construction, and Repair

De Beers Canada Inc. OP 050 SLIPS, TRIPS, FALLS AND PEDESTRIAN SAFETY - SURFACE

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

Building Regulations Technical Guidance Document K. Stairways, Ladders, Ramps and Guards

The replacement or modification of existing windows shall comply with the following requirements:

Errata has been identified as follows:

SCOPE This guideline applies to all construction projects on Emory University properties, including renovation projects.

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Stair Layout Guide. Taking You To The Next Level E. 6 th Street Sandwich IL

Building Regulations Technical Guidance Document M. Access for People with Disabilities

Certification: Building Plans Examiner. Exam ID: B3

Healthcare Engineering. Code Summary Report

Common ADA Errors and Omissions in New Construction and Alterations

Protection from falling. collision and impact. The Building Regulations edition for use in England* ONLINE VERSION APPROVED DOCUMENT

2010 FLORIDA BUILDNG CODE, FIRE AND LIFE SAFETY i

BUILDING PERMIT SPECIFICATIONS

Slip, Trip & Fall Program Table of Contents

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

CHAPTER 10 MEANS OF EGRESS. User Note: See Preface page iv ("marginal markings" for Chapter 10 reorganization information.)

AUTOMATIC SWINGING DOOR

MEANS OF EGRESS CHAPTER 10

ADA POST INSPECTION CHECKLIST. Job No. Route County Location

American Academy of Physical Medicine and Rehabilitation Site Survey Report

NRC Canadian Codes Centre. Codes Update. Nedjma Belrechid October 2012

New Ontario Building Code Highlights

REQUIREMENT 3. Usable Doors

RESIDENTIAL WOOD DECKS

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

MEANS OF EGRESS CHAPTER 10

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

WALKING-WORKING SURFACES (SLIPS, TRIPS, AND FALLS)

NFPA Frequently Asked Questions

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards

SAFE ACCESS, LADDERS, FLOOR & WALL OPENINGS, STAIRS AND RAILING SYSTEMS

Chapter 2 MEANS OF ESCAPE

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

Hanna delivers the technical and marketing expertise needed to produce a car wash that meets the car wash customer's expectations.

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

GEOMETRIC DESIGN CIVL 3161

At the completion of this guide you should be comfortable with the following:

Fixed and Portable Ladders- A Guide to OSHA Rules

MEANS OF EGRESS CHAPTER 10

Charter Township of Shelby Harry Reese Building Director

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

Building for Everyone:

Stair Parts Installation. Tricks

Gas Meter Clearances and Service Installation Requirements

ZONING ADMINISTRATOR BULLETIN NO. 9. Relevant Code Sections:

TurboCAD Architectural

SolidWorks: Mirror, Revolve, and. Introduction to Robotics

10' 16' Maximum. Backwall 5' 5'

EXAM GUIDE. Schematic Design. Overview 2. Interior Layout Vignette 3 Sample Passing Solution 5 Sample Failing Solution 6

STANDARDS AUSTRALIA. Committee ME-064 Access for People with Disabilities. Australian Standard

Ministry of the Environment Decree on accessible building

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

MEANS OF EGRESS CHAPTER 10

ORDINANCE NO THE CITY COUNCIL OF ALEXANDRIA HEREBY ORDAINS:

The emergency provisions affect the following Building Code sections:

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Technical Bulletin: Understanding the ADA and Implications for Office Design

MEANS OF EGRESS CHAPTER 10

AUTOMATIC OPENER SYSTEM FOR OUTSWING RESIDENTIAL GARAGE DOORS. Exclusively by:

Transcription:

INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Sec.11B-403,404,405, Effective: 01/01/2014 408,504,505,802 DOCUMENT NO.: P/BC 2014-085 Revised: 07/01/2015 Previously Issued As: P/BC 2011-085 ACCESSIBILITY DETAILS FOR RAMPS, STAIRS & ELEVATORS RAMP WITH INTERMEDIATE SWITCH-BACK PLATFORM FIGURE 11B-405.7 RAMP LANDINGS RAMP WITH TURNING PLATFORM RAMP LANDING AND DOORWAY THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY Page 1 of 7

RAMPS 11B-505.10.1 TOP AND BOTTOM EXTENSION AT RAMPS. Ramp handrails shall extend horizontally above the landing for 12 inches beyond the top and bottom of ramp runs. Extensions shall return to a wall, guard, or landing surface, or shall be continuous to the handrail of an adjacent ramp run. SIDEWALK OBSTRUCTIONS RAMPS AND HANDRAILS Page 2 of 7

DOORWAYS AT RAMP LANDINGS 3" MAX 3" MAX 42" MIN 42" MIN RAMP UP RAMP DOWN * INCREASE TO 60" IF DOOR ENCROACHES LANDING BY MORE THAN 3" 42" MIN ENCROACHES BOTTOM * 42" MIN * * INCREASE TO 72" IF DOOR LANDING BY MORE THAN 3" RAMP UP 3" MAX 60" RAMP DOWN 3" MAX 60" 42" MIN 42" MIN RAMP UP RAMP DOWN 60" MIN 60" MIN DOORWAYS AT TOP LANDING SPACE OF A RAMP DOORWAYS AT BOTTOM LANDING SPACE OF A RAMP Page 3 of 7

STAIRWAYS Exception: Curved stairways with winder treads are permitted at stairs which are not part of a required means of egress. 11B-504 STAIRWAYS Page 4 of 7

STAIRS RADIUS ½ MAX (12.7MM) 30 o MAX 1-¼ MAX (32 MM) 1-¼ MAX (32 MM) 1-¼ MAX (32 MM) (a) RADIUS OF TREAD EDGE (TYPICAL FOR ALL PROFILES) (b) ANGLED RISER ( C ) CURVED NOSING ( d ) BEVELED NOSING FIGURE 11B-504.5 STAIR NOSINGS FIGURE 11B-505.4 HANDRAIL HEIGHT FIGURE 11B-505.5 HANDRAIL CLEARANCE FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS Page 5 of 7

ELEVATORS FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS MINIMUM DIMENSIONS DOOR LOCATION DOOR CLEAR WIDTH INSIDE CAR, SIDE TO SIDE INSIDE CAR, BACK WALL TO FRONT RETURN TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS INSIDE CAR, BACK WALL TO INSIDE FACE OF DOOR Centered 42 inches 80 inches 51 inches 54 inches Side (off-centered) 36 inches 68 inches 51 inches 54 inches Any 36 inches 54 inches 80 inches 80 inches Any 36 inches 60 inches 60 inches 60 inches 1. A tolerance of minus 5/8 inch (15.9 mm) is permitted. 2. Other car configurations that provide a turning space complying with Section 11B-304 with the door closed shall be permitted. Page 6 of 7

ELEVATORS FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS Door and signal timing. The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/s) or T = D/(455 mm/s) = 5 seconds minimum where T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1524 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway door. (11B-407.3.4) FIGURE 11B-407.2.3.2 CAR DESIGNATIONS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES Exceptions: 1. For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the point 60 inches (1524 mm) directly in front of the farthest hall call button and the audible signal is sounded. 2. Destination-oriented elevators shall not be required to comply with Section 11B-407.3.4. Door delay. Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. (11B-407.3.5) FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCE Page 7 of 7