DIESEL GENERATOR SET MTU 16V4000 DS2050

Similar documents
Diesel Generating Set

Diesel Engine Driven Generators Page 1 of 6

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

DIESEL GENERATOR SETS

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

C18 ACERT Fire Pump Tier bkw/ rpm

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Spark-ignited generator set

How To Use A Cat Diesel Engine

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Technical Specification. Generating Set with Waukesha engine burning natural gas

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

3516 Industrial Engine

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Marine Generating Sets 3.7 to 50 kva

Atlas Copco Generators

Diesel Generator Set Model DFHC 60 Hz

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

Diesel Generator Set Model DFMB 60 Hz

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

IGSA POWER GENERATION SYSTEMS

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

C18 Diesel Oilfield Generator Set

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Annex-A TECHNICAL SPECIFICATION

Specifications for Volkswagen Industrial Engine

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

How To Control A Power Command Powerplant

Magnum Mobile Generator MMG55 Specifications

Diesel Generator Set Model DGDK 60 Hz

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

1013 E. The engine for agricultural equipment.

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

WÄRTSILÄ 50DF PRODUCT GUIDE

A Single Source for all Power System Solutions

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

912. The engine for construction equipment.

STANDBY PERMANENT MOUNT SERIES GENERATOR

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

APS100 Rental Generator Set Specification

WÄRTSILÄ 34DF PRODUCT GUIDE

Fire Pump Plan Review March 2010

Hydraulic Control Solutions

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

CUKUROVA GENERATOR SYSTEMS

PM734F - Technical Data Sheet Winding 28

New 27 hp 2 Cylinder Liquid-Cooled Engine

The Yachtmans Choice...

The kva RAnge

BHKW. Power. Power. Gas engines for CHP units and gensets. MAN Engines. A Division of MAN Truck & Bus

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

CUKUROVA GENERATOR SYSTEMS

Bergen Engines Products and Applications

Citius-sarjan merimoottorit

Power Generation. Power Control PCL System Generator Set Control

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Electronic Diesel Control EDC 16

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Signature and ISX CM870 Electronics

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

EMERGENCY AND STANDBY POWER SYSTEMS

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

RH 12.5 RH Crawler Excavator Specifications

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

LOAD BANK TESTING PROCEDURE

Generators TEM. for small hydroelectric power stations. Electric Machines

Engine catalogue. Marine Diesel engines. MAN range - light duty

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

PowerCommand 3201 digital generator set control

Transcription:

DIESEL GENERATOR SET MTU 16V4000 DS2050 Standby Power: 2070 KWel 380V/60 Hz/Water Charge Air Cooling/Fuel Consumption Optimized Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low fuel consumption - Optimized system integration ability - High reliability - High availability of power - Long maintenance intervals // MTU Onsite Energy is a single-source supplier // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certified to standards ISO 2008:9001 and ISO 2004:14001 - Generator set complies to ISO 8528 - Generator meets NEMA MG1, BS5000, ISO, DIN EN and IEC standards - NFPA 110 // Performance Assurance Certification (PAC) - Engine-generator set tested to ISO 8528-5 for transient response - 85% load factor - Verified product design, quality and performance integrity - All engine systems are prototype and factory tested // Complete range of accessories available - Control panel - Fuel system - Fuel connections with shut-off valve mounted to base frame - Starting/charging system // Emissions - Fuel consumption optimized // Certifications - CE certification option // Power Rating - System rating: 2200 kva - 2350 kva - Accepts rated load in one step per NFPA 110 - Generator set complies to G3 according to ISO 8528-5 - Generator set exceeds load steps according to ISO 8528-5

2 / / / MTU 16V4000 DS2050 / FC / 60 Hz / 380V Application data ➀ // Engine Manufacturer MTU Model 16V4000G43 Type 4-cycle Arrangement 16V Displacement: l 76.3 Bore: mm 170 Stroke: mm 210 Compression ratio 16.4 Rated speed: rpm 1800 Engine governor ADEC (ECU 7) Max power: kwm 2280 Air cleaner Dry // Fuel System Maximum fuel lift: m 5 Total fuel flow: l/min 20 l/hr g/kwh At 100% of power rating: 554.9 202 At 75% of power rating: 412.0 200 At 50% of power rating: 287.1 209 // Liquid Capacity (Lubrication) Total oil system capacity: l 300 Engine jacket water capacity: l 175 Intercooler coolant capacity: l 50 // Combustion Air Requirements Combustion air volume: m 3 /s 3.1 Max. air intake restriction: mbar 50 // Cooling/Radiator System Coolant flow rate (HT circuit): m 3 /h 81 Coolant flow rate (LT circuit): m 3 /h 35 Heat rejection to coolant: kw 840 Heat radiated to charge air cooling: kw 560 Heat radiated to ambient: kw 90 // Exhaust System Exhaust gas temp. (after turbocharger): c 465 Exhaust gas volume: m 3 /s 7.6 Maximum allowable back pressure: mbar 85 Minimum allowable back pressure: mbar 30 ➀ All data refers only to the engine and is based on ISO standard conditions (25 C and 100m above sea level). ➁ Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. All fuel consumption values refer to rated engine power.

3 / / / MTU 16V4000 DS2050 / FC / 60 Hz / 380V Standard and Optional Features // System Ratings (kw/kva) MTU 16V4000 DS2050 Standby Power Voltage: V 380 Phases 3 Frequency: Hz 60 Power output: kwel 2070 Power output: kva* 2588 Rated AMPS 3932 Generator model Marathon 744RSL7103 * cos phi = 0,8 // Engine 4-Cycle Standard single stage air filter Oil drain extension & shut-off valve Closed crankcase ventilation Governor-electronic isochronous Common rail fuel injection Fuel consumption optimized engine // Generator NEMA MG1, BS5000, ISO, DIN EN and IEC standards Self-ventilated Superior voltage waveform Solid state, volts-per-hertz regulator No load to full load regulation ±0.25% voltage regulation no load to full load Brushless alternator with brushless pilot exciter 4 pole, rotating field Sustained short circuit current of up to 300% of the rated current for up to 10 seconds (marathon generator) Marathon low voltage generator // Cooling System Jacket water pump Thermostat(s) Water charge air cooling Jacket water heater Represents standard features Represents optional features

4 / / / MTU 16V4000 DS2050 / FC / 60 Hz / 380V Standard and Optional Features, continuation // Control Panel Pre-wired control cabinet for easy application of customized controller (V1+) Island operation (V2) with ATS (V3a) incl. control of generator and mains breaker (V3b) Island parallel operation of multiple gensets (V4) with short (< 10s) mains parallel overlap synchronization (V5) Mains parallel operation of a single genset (V6) Mains parallel operation of multiple gensets (V7) Basler controller Deif controller Complete system metering Digital metering Engine parameters Generator protection functions Engine protection SAE J1939 engine ECU communications Parametrization software Multilingual capability Multiple programmable contact inputs Multiple contact outputs Event recording IP 54 front panel rating with integrated gasket Different expansion modules Remote annunciator Daytank control Generator winding temperature monitoring Generator bearing temperature monitoring Differential protection with multi-function protection relay Modbus RTU-TCP gateway // Fuel System Flexible fuel connectors mounted to base frame Fuel filter with water separator Switchable fuel filter with water separator Separate fuel cooler // Starting/Charging System 24V starter Starter batteries Battery rack & cables Battery charger // Mounting System Welded base frame Resilient engine and generator mounting Modular base frame design // Exhaust System Exhaust bellows with connection flange Y-connection-pipe Represents standard features Represents optional features

5 / / / MTU 16V4000 DS2050 / FC / 60 Hz / 380V Weights and dimensions Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 5090 x 1836 x 2330 mm 12893 kg Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. Sound data // Consult your local MTU Onsite Energy distributor for sound data. Emissions data // Consult your local MTU Onsite Energy distributor for emissions data. Rating Definitions and conditions // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO 8528-1, ISO-3046-1, BS 5514 and AS 2789. Average Load Factor: 85%. Operating hours/year: max. 500. // Deration factor: Altitude: Consult your local MTU Onsite Energy Power Generation distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation distributor for temperature derations. Rated power is available up to 40 C and 400m above sea level. Subject to change. 32310231 Edition 01/15 ENC 2015-11. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com