F263 Series Liquid Level Switches

Similar documents
T25 Two-Stage Room Thermostat

OLS-2100 Occupancy Light Switch

P66 Series Electronic Fan Speed Controls

TE-6300P Series Temperature Sensors

Direct AC Wiring Option Installation Guide

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

P70, P72, and P170 Series Controls for Dual Pressure Applications

Regulatory Compliance Statement

! WARNING. Before using product, read and understand instructions.

ZigBee Extender 3. Features. Supported Models and Requirements. Important Safety Instructions. What Is Included: Specifications

Bounce & Spin ZebraTM

Power Over Ethernet Adapters POE101

Broadband Telecommunications Drop Amplifier

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

About the HotWire Slot Standalone Shelf

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

VG7000 Series Bronze Control Valves

A99B Series Temperature Sensors

Read this document before using this product.

Universal Laptop Charger

Gateway Port Replicator User Guide

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

MoCA Adapter MC1001 v2 Installation Guide

CST29A Adapter Block for Carlyle Compressors

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Power supply unit Model: PAC-SC50KUA

AD511 Active Iridium Antenna User Manual Mar 12 V4.0

Leak Detection System

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

System 350 A350A/B Electronic Temperature Control

EPSON USB/Parallel Adapter User s Guide

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Compact I/O End Caps/Terminators

User guide. Miracast Wireless Display IM10

Installer Guide smart connect

ASUS Miracast Dongle E-MANUAL E8741

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

User guide. Stereo Bluetooth Headset SBH80

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

Mini Speaker. Printed in China Part No P Version D. CWA BT300 Product Information Guide

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

User s Manual VTECH Printed in China

HE-6800 Series Humidity Transmitters with Temperature Sensor

FortiFone QuickStart Guide for FON-670i and FON-675i

Triple Expansion Chassis

2013 VTech Printed in China US

READ FIRST! Universal Car/Air Adapter User Manual

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

User guide. Stereo Bluetooth Headset SBH70

Manual. Simrad StructureScan LSS-1 Sonar Module. English

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Wireless Indoor/ Outdoor Thermometer

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

Model Owner s Manual. Español - P. 19 Français - P. 39

EPSON USB/Parallel Adapter User s Guide

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

StructureScan HD Module. Installation Guide ENGLISH

How To Set Up An Ecm Display On A D210 (D210) (D2) (Ecm) (Emc) (Mcd) (Power Supply) (Mm) (Camellom) (Ios)


BroadBand PowerShield. User Manual

P266 Series Single-Phase Condenser Fan Speed Controls

56-A11A Plantronics Calisto Headset with Bluetooth USB Adapter. User Guide

GSM-EXT Cable Assembly Installation Guide

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

M.2 NGFF SSD to 2.5in SATA Adapter

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Messager USB Digital Messaging System

Dual M.2 NGFF SATA RAID Adapter

USB 3.0 to M.2 NGFF SSD Enclosure with UASP

WARNING CANADIAN D.O.C. WARNING

VG2000 Series Cast Iron Flanged Globe Valves

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

USB 2.0 USB 2.0 ETHERNET AUDIO JACK AND RCA VIDEO HDMI MICRO SD CARD MICRO USB POWER

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Nevco, Inc. Installation Manual

Product Documentation on the World Wide Web

ARCHOS (

Residential Gateway (RG) Battery Backup REV B

FortiFone QuickStart Guide for FON-370i

USB Mini Print Server PS121. Installation Guide

IFS SP-PoE Splitter User Manual

M.2 NGFF SATA Enclosure - USB 3.1 (10Gbps)

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

Operation Instructions PowerCool Series

Model 70A00-1. GSM Cellular Communications Center

56-K61A Plantronics Calisto Headset with Bluetooth USB Adapter. User Guide

Backup Scanner Module

ES-CAM3A Outdoor IP Camera

User guide. Stereo Bluetooth Headset SBH50

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Power Supply Guide Version 1.0 for D-Show

V46 Pressure-Actuated Water-Regulating Valve

Wireless Optical Travel Mouse

User Guide. LXX35-LED Light Source. Luxxor LXX35-LED User Guide. Contents

SmartDock for Xperia ion User guide

Transcription:

F263 Series iquid evel Switches Installation Instructions Part No. 24-7664-2985, ev. A Issued February 18, 2015 Applications IMPOTANT: Use this F263 Series iquid evel Switch only as an operating control. Where failure or malfunction of the liquid level switch could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the liquid level switch. IMPOTANT : Utiliser ce F263 Series iquid evel Switch uniquement en tant que dispositif de régulation. orsqu'une défaillance ou un dysfonctionnement du liquid level switch risque de provoquer des blessures ou d'endommager l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs de protection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que des systèmes de supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction d'avertissement ou de protection en cas de défaillance ou de dysfonctionnement du liquid level switch. IMPOTANT: Do not use F263MAC and F263MAP iquid evel Switches where the fluid in the pipes drops below the fluid s freezing point, causing an internal freeze-up. efer to the QuickIT website for the most up-to-date version of this document. IMPOTANT: Do not use F263 Series iquid evel Switches with hazardous fluids or in hazardous atmospheres. Use in these conditions may cause malfunction or improper operation. The F263 Series iquid evel Switches are designed to maintain a liquid level in indoor or outdoor closed tanks holding water or other non-corrosive liquids. When the liquid level in the tank rises above or falls below the required level, the SPDT switch closes one circuit and opens a second circuit. Use F263 Series iquid evel Switches in closed tanks where a liquid level is to be maintained. A change in the liquid level opens or closes an electrical circuit. Use F263MAP switches on indoor or outdoor tanks that hold water or other nonhazardous liquids at temperatures greater than the liquid's freezing point and between -20 F (-29 C) and 212 F (100 C). The maximum allowable liquid pressure is 150 psig (1035 kpa). Use F263MAC switches on indoor or outdoor tanks that hold water or other nonhazardous liquids at temperatures greater than the liquid's freezing point and between -20 F (-29 C) and 250 F (121 C). The maximum allowable liquid pressure is 100 psig (690 kpa). Note: Do not use these liquid level switches with liquids with a density less than the density of water. F263 Series iquid evel Switches Installation Instructions 1

Installation Dimensions 4 [102] 2 [51] 2-3/4 [70] 1-3/8 [35] 11/16 [18] 2-9/16 [65] 4-11/16 [119] 1/2 [13] TP. THEAD ENGAGEMENT (39 mm HEX) 1-11 1/2 NPT 5-7/16 [138] 1/2 in. O PG-16 CONDUIT OPENING 10-5/8 [270] 5-13/16 [132] 1 [25] FIG:F263_dmnsns Figure 1: F263 iquid evel Switch with Type 3/IP43 Enclosure Dimensions, in. (mm) 2 F263 Series iquid evel Switches Installation Instructions

Installation Procedure! WANING: isk of Personal Injury. Shut off the liquid supply and relieve pressure in the line before servicing the valve. Contents of liquid lines could be under pressure and the release of liquid under pressure may cause severe personal injury. AVETISSEMENT : isque de blessure. Couper l'arrivée de liquide et évacuer la pression présente dans la conduite avant toute intervention sur la vanne. es liquides à l'intérieur des conduites peuvent être sous pression et la libération soudaine de liquide sous pression risque de provoquer des blessures graves. IMPOTANT: Do not allow the float to touch the side of the tank or any other obstructions. IMPOTANT: To avoid damaging the switch, do not tighten by grasping the switch enclosure. Use only the wrench flats provided. IMPOTANT: Do not remove the cover gasket or the wire grommet in the conduit opening. emoving these items will allow moisture to enter and condensate to form inside a NEMA 3 enclosure. IMPOTANT: To avoid damaging the float, ensure that the float is not subject to pressures exceeding these limitations: 100 psig (690 kpa) for copper float 150 psig (1035 kpa) for polycarbonate float Install the F263 control into a properly threaded (and sealed) 1 in. diameter hole in the tank at the desired height for the liquid level. Position the control with the arrow on the enclosure pointing upward. Ensure that the threads are adequately sealed. 70 mm Wiring! 240 mm Figure 2: Installing the Float Switch WANING: isk of Electric Shock. Disconnect the power supply before making electrical connections. The printed circuit board and its components are at AC line voltage. Contact with components carrying hazardous voltage can cause electric shock and may result in personal injury or death. AVETISSEMENT : isque de décharge électrique. Débrancher l'alimentation avant de réaliser tout raccordement électrique. e circuit imprimé et ses composants présentent une tension CA. Tout contact avec des composants porteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. IMPOTANT: Use copper conductors only. Make all wiring connections in accordance with local, national, and regional regulations. Do not exceed the flow switch s electrical ratings. Color-Coded Screw Terminals IMPOTANT: Use the terminal screws provided (8-32 x 1/4 in. binder head). Substitution of other screws voids the warranty and agency approvals. FIG:F263_mntng_dmnsns All F263 models have color-coded screw terminals. ed is common, ed closes to ellow on liquid level increase, ed closes to lue on liquid level decrease. F263 Series iquid evel Switches Installation Instructions 3

The F263 switch has three color-coded terminals. ed is common. emove the cover to make wiring connections. See Figure 3 for terminal identification. Figure 3: Terminal and Wiring Identification Table 1: F261 Control Switch Action Flow Action Switch Closure Increase ed to ellow Decrease ed to lue See Figure 4 and Figure 5 for suggested circuits for controlling liquid levels with several inches (or feet) between minimum and maximum levels. Increase in evel Above Setpoint Pump 2 ellow lue ed Pump In High evel ow evel Decrease in evel elow Setpoint Figure 4: Circuit for Controlling Fill evels 1 FIG:F263_swtchactn FIG:fill_lvl_cntrl Setup and Adjustments! Pump 2 Pump Out High evel ow evel Figure 5: Circuit for Controlling Dump evels CAUTION: isk of Property Damage. Do not set the switch lower than the factory setting. The switch is factory set at approximately the minimum flow rate. A lower setting may result in the switch failing to return to a no-flow position which may result in damage to the controlled equipment or other property. MISE EN GADE : isque de dégâts matériels. Ne pas régler le commutateur sur une valeur inférieure au paramètre d'usine. e commutateur est réglé en usine sur une valeur correspondant environ au débit minimum. Un réglage sur une valeur inférieure risque d'empêcher le commutateur de revenir sur une position «aucun-débit», ce qui risque d'endommager l'équipement contrôlé ou de provoquer d'autres dégâts matériels. 1 FIG:dmp_lvl_cntrl 4 F263 Series iquid evel Switches Installation Instructions

! CAUTION: isk of Property Damage. Do not attempt to change sealed settings. Attempted adjustment may damage the control or cause loss of calibration or other property damage. MISE EN GADE : isque de dégâts matériels. Ne pas essayer de modifier la position des éléments de réglage bloqués. Toute tentative de réglage risque d'endommager le dispositif de contrôle ou de provoquer la perte des valeurs d'étalonnage ou d'autres dégâts matériels. Operation The F263 Float Switch controls water levels to within approximately 1/2 in. (13 mm). When the liquid level falls approximately 1/2 in. (13mm) below the height at which the switch is installed, the switch closes the red contact (common) to the blue contact. See Figure 3 and Figure 6. When the liquid level in the tank rises to the height at which the switch is installed, the switch closes the red contact (common) to the yellow contact. See Figure 3 and Figure 6. Dump F H IMPOTANT: All F263 switches are factory-set and factory-sealed. Do not attempt to change the factory settings. Changing the factory settings voids the warranty. Checkout Procedure efore applying power, ensure that installation and wiring connections are made to job specifications. After making all necessary adjustments and electrical connections, put the system into operation and observe at least three complete operation cycles before leaving the installation site. Fill Figure 6: F263 Float Switch Setup epair Information Do not make field repairs, except for replacement of the float. For a replacement control or float, contact the nearest Johnson Controls/PENN distributor. For more information, contact Johnson Controls/PENN application engineering at 1-800-275-5676. F FIG:F263_flt_swtch_setup F263 Series iquid evel Switches Installation Instructions 5

Technical Specifications Table 2: F263 Series iquid evel Switch Electrical atings U60730/U1059 EN60730 Volts 50/60 Hz 24 120 208 240 24 230 Horsepower 1 1 1 Full oad Amperes 16 10 10 8 ocked otor Amperes 96 60 60 48 esistive Amperes 16 16 10 10 16 16 Pilot Duty VA 125 720 720 720 77 720 Table 3: U Conformity Declaration Information Information Description Purpose of Control F263 iquid evel Float Switch Construction of Control Electronic independently mounted control Number of Cycles 100,000 cycles Method of Mounting Mounting to sensed media vessel/orientation Control Type 1 or Type 2 Action Type 1.C (Microinterruption) External Pollution Situation Pollution degree 4 Internal Pollution Situation Pollution degree 2 ated Impulse Voltage 4,000 VAC all Pressure Temperature Enclosure: 266 F (130 C ) Switch Component: 252 F (122 C) Control Adjustment - Instruction Field Wiring ating Wire/Cord Temperature atings: 140 F (60 C) only permitted when ambient air and media are less than 113 F (45 C) 167 F (75 C) only permitted when ambient air and media are less than 140 F (60 C) 194 F (90 C) only permitted when ambient air is less than 140 F (60 C) and media is less than 167 F (75 C) 302 F (150 C) permitted when ambient air is less than 140 F (60 C) and media is less than 249 F (121 C) Vessel Pressure F263 iquid evel Float Switch with Copper Float: 100 psi (690 kpa) F263 iquid evel Float Switch with Polycarbonate Float: 150 psi (1935 kpa) F263 Series iquid evel Float Switches (Part 1 of 2) Switch SPDT Enclosure U: Type 4 CE: IP67 Wiring Connections Three color-coded screw terminals and one ground terminal Conduit Connection One 7/8 in. (22 mm) hole for 1/2 in. trade size (or PG16) conduit Pipe Connector 1 in. 11-1/2 NPT threads Minimum Tank Diameter 9 in. (229 mm) Maximum iquid Pressure 100 psig (690 kpa) for copper float 150 psig (1,035 kpa) for polycarbonate float 6 F263 Series iquid evel Switches Installation Instructions

F263 Series iquid evel Float Switches (Part 2 of 2) iquid Temperature ange Minimum: -40 F (-40 C) or liquid freezing point 1 Ambient Conditions Minimum: -40 F (-40 C) 1 Maximum: 212 F (100 C) polycarbonate, 250 F (121 C) copper 2 Maximum: 140 F (60 C) 2 Compliance North America: cuus isted; U 60730, File E6688; FCC Compliant to CF47, Part 15, Subpart, Class Industry Canada (IC) Compliant to Canadian ICES-003, Class limits Europe: CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive and the ow Voltage Directive. Australia/New Zealand Mark: CM Compliant 1. Ensure that the low liquid temperature combined with the low ambient temperature does not lead to the freezing the liquid inside the body (or bellows, where appropriate). Please observe the liquid freezing point. 2. At higher temperatures, the maximum allowed liquid temperature becomes lower. The temperature inside of the electrical switch should not exceed 158 F (70 C). The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult Johnson Controls/PENN efrigeration Application Engineering at 1-800-275-5676. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. United States Emissions Compliance This equipment has been tested and found to comply with the limits for a Class digital device, pursuant to Part 15 of the FCC ules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - eorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help. Canadian Emissions Compliance This Class () digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment egulations. Cet appareil numérique de la Classe () respecte toutes les exigences du èglement sur le matériel brouilleur du Canada. uilding Efficiency 507 E. Michigan Street, Milwaukee, uilding Efficiency WI 53202 Johnson Controls and PENN are registered 507 trademarks E. Michigan of Street, Johnson Milwaukee, Controls, WI Inc. 53202 in the United States of America and/or other countries. All other trademarks used herein are the property Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. of their respective owners. Copyright 2015 by Johnson Controls, Inc. All rights reserved. All other marks herein are the marks of their respective owners. 2011 Johnson Controls, Inc. F263 Series iquid evel Switches Installation Instructions 7 Published in U.S.A. www.johnsoncontrols.com