FRP-CONFINED CIRCULAR COLUMNS UNDER SMALL ECCENTRIC LOADING

Similar documents
USE OF CFRP LAMINATES FOR STRENGTHENING OF REINFORCED CONCRETE CORBELS

ANALYSIS FOR BEHAVIOR AND ULTIMATE STRENGTH OF CONCRETE CORBELS WITH HYBRID REINFORCEMENT

BEHAVIOR OF SHORT CONCRETE COLUMNS REINFORCED BY CFRP BARS AND SUBJECTED TO ECCENTRIC LOAD

Behavior of High-Strength Concrete Rectangular Columns

Hardened Concrete. Lecture No. 14

In-situ Load Testing to Evaluate New Repair Techniques

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

THE EFFECT OF STIRRUPS AND HOOKED STEEL FIBERS INSTEAD ON MOMENT-ROTATION CAPACITY OF BEAM-COLUMN CONNECTIONS

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system

CFRP STRENGTHENING OF CIRCULAR CONCRETE SLAB WITH AND WITHOUT OPENINGS

Uniaxial Compressive Strength of Cold-formed Steel Tubular Sections with Recycled Aggregate Concrete Infill

NONLINEAR FINITE ELEMENT ANALYSIS FOR REINFORCED CONCRETE SLABS UNDER PUNCHING LOADS

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

LARGE SCALE TENSILE TESTS OF HIGH PERFORMANCE FIBER REINFORCED CEMENT COMPOSITES

IMPROVING THE STRUT AND TIE METHOD BY INCLUDING THE CONCRETE SOFTENING EFFECT

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

APE T CFRP Aslan 500

NONLINEAR BEHAVIOR AND FRAGILITY ASSESSMENT OF MULTI-STORY CONFINED MASONRY WALLS UNDER CYCLIC LOADS

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

Numerical modelling of shear connection between concrete slab and sheeting deck

A Decade of Performance of FRP-Repaired Concrete Structures

Optimising plate girder design

SEISMIC RETROFITTING OF STRUCTURES

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

bi directional loading). Prototype ten story

Strength of Concrete

A Comparative Analysis of Modulus of Rupture and Splitting Tensile Strength of Recycled Aggregate Concrete

The Original Carbon Fiber Reinforced Polymer System

The elements used in commercial codes can be classified in two basic categories:

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

Reliability of Temperature-Dependent Models for Analysis of Reinforced Concrete Members Subjected to Fire

STRENGTHENING AND LOAD TESTING OF THREE BRIDGES IN BOONE COUNTY, MO

FLEXURAL BEHAVIOUR OF HYBRID FRP-UHPC GIRDERS UNDER STATIC LOADING

Lab 1 Concrete Proportioning, Mixing, and Testing

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT

DETERMINATION OF TIME-TEMPERATURE SHIFT FACTOR FOR LONG-TERM LIFE PREDICTION OF POLYMER COMPOSITES

Assistant Professor of Civil Engineering, University of Texas at Arlington

Strengthening of Brick Masonry Walls against Earthquake Loading

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION

Prestressed Concrete Pipe Fitness for Service and Repair

MATERIALS AND MECHANICS OF BENDING

Sheet metal operations - Bending and related processes

SEISMIC RETROFITTING OF EARTHQUAKE-DAMAGED CONCRETE COLUMNS BY LATERAL PRE-TENSIONING OF FRP BELTS. K. Nasrollahzadeh Nesheli 1 and K.

Technical Presentation: Follow up on HVS testing of Roller Compacted Concrete and Ultra-thin reinforced concrete test sections

The University of Birmingham (Live System)

Overview of Topics. Stress-Strain Behavior in Concrete. Elastic Behavior. Non-Linear Inelastic Behavior. Stress Distribution.

CH 6: Fatigue Failure Resulting from Variable Loading

Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole

Tensile Testing Laboratory

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

METHOD OF STATEMENT FOR STATIC LOADING TEST

Seismic Retrofit of Reinforced Concrete Beam- Column T-Joints in Bridge Piers with FRP Composite Jackets

Shrinkage and Creep Properties of High-Strength Concrete Up To 120 MPa

Drained and Undrained Conditions. Undrained and Drained Shear Strength

Optimum proportions for the design of suspension bridge

Technical Notes 3B - Brick Masonry Section Properties May 1993

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

3. Test Methods for Evaluation of ESCR of Plastics

Deflection Calculation of RC Beams: Finite Element Software Versus Design Code Methods

The Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, February 2011

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

Research on the meaning of reinforcement ductility for a behavior of double-spans reinforced concrete beam.

Lap Fillet Weld Calculations and FEA Techniques

Numerical Analysis of the Moving Formwork Bracket Stress during Construction of a Curved Continuous Box Girder Bridge with Variable Width

Experimental and analytical investigation of ferrocement water pipe

Seismic performance evaluation of an existing school building in Turkey

III. Compression Members. Design of Steel Structures. Introduction. Compression Members (cont.)

The Influence of Porosity & Aspect Ratio on the Compressive Behavior of Pervious Concrete. Alexander Hango

The International Journal Of Science & Technoledge (ISSN X)

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2

LOAD-CARRYING CAPACITY OF AXIALLY LOADED RODS GLUED-IN PERPENDICULAR TO THE GRAIN

PVC PIPE PERFORMANCE FACTORS

ABSTRACT 1. INTRODUCTION 2. DESCRIPTION OF THE SEGMENTAL BEAM

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING

PERFORMANCE TESTING OF BITUMINOUS MIXES USING FALLING WEIGHT DEFLECTOMETER

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

Stress Strain Relationships

Local buckling of plates made of high strength steel

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied

Full-Scale Load Testing of Steel Strutting System. For. Yongnam Holding Limited

The Fundamental Principles of Composite Material Stiffness Predictions. David Richardson

*Currently employed at UTAS, work for this paper was carried out while the author was formerly employed at MSC Software.

Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading

Fire and Concrete Structures

Detailing of Reinforcment in Concrete Structures

The Bending Strength of Pasta

Stability Of Structures: Additional Topics

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:

Retrofit Design of Damaged Prestressed Concrete Cylinder Pipes

TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing

Transcription:

FRP-CONFINED CIRCULAR COLUMNS UNDER SMALL ECCENTRIC LOADING BY Kamal Nassif Ghali 1, Sami H. Rizkalla 2, Mohamed Ahmed Kassem 3 Tarek Mohamed Fawzy 4*, Mohamed Hussein Mahmoud 5 ABSTRACT Fiber reinforced polymers (FRP) confined concrete columns benefit from a confining effect due to restraint of the lateral expansion. More research work is necessary in order to investigate the behavior of RC columns confined by FRP under small eccentric loads. Eighteen FRP-confined concrete circular columns were tested under small eccentric compression loading until failure. These specimens were strengthened by a full confinement. The small load eccentricity and slenderness ratio were the basic parameters considered in the experimental program. The effect of small load eccentricity on the ultimate load and ductility of confined columns with different slenderness ratio were reported. A significant decrease in confinement effect was found with the increase of load eccentricity. An empirical equations based on regression analysis of experimental results were proposed, that can be used to determine the ultimate load of FRP-confined concrete columns taking into account small load eccentricity as well as slenderness ratio of columns. The present study can be considered as an attempt to define the real behavior of CFRP-confined compression members, as the available data on axially loaded confined members can not give accurate information on behavior of confined compression members. Keywords: column, confinement, FRP, eccentric load, ultimate load 1. INTRODUCTION Lateral confinement of concrete columns by means of FRP-wrapping will increase compressive strength and ultimate strain (ductility). Most investigations have been directed to axially loaded columns with zero eccentricity, such as 1,2,3,9,10,11 show that the strength and ductility increases for concrete columns confined with FRP shell. However, more research work is necessary in order to investigate the behavior of RC columns confined by FRP under eccentric loads 8,13, as it seems that axially loaded columns do not exist in practice, therefore a minimum eccentricity recommended in most codes, and that is why small eccentrically loaded columns may be more representative 4,5,6,7. Eighteen FRP-confined concrete circular columns were tested under small eccentric compression loading until failure. These specimens were strengthened by a full confinement. The small load eccentricity and slenderness ratio were the basic parameters considered in the experimental program. The effect of small load eccentricity on the ultimate load, axial and lateral strain and ductility of confined columns with different slenderness ratio were reported. It was found that the load carrying capacity of FRP-confined columns was very sensitive to small load eccentricity, where a significant decrease in confinement effect was found with the increase of load eccentricity. An empirical equations based on experimental results were proposed, that can be used to determine the ultimate load of FRP-confined concrete columns taking into account small load eccentricity as well as slenderness ratio of columns. This study can be considered as an attempt to define the real behavior of CFRP-confined compression members. 1 Prof. of Concrete Structures, Ain Shams University, Egypt. 2 Distinguished Prof. Civil Engineering Dept., North Carolina State University, USA. 3 Prof. of Structural Engineering, Tanta University, Egypt. 4* Associate Prof. Structural Engineering, Tanta University, Egypt. e-mail: elakrat2000@yahoo.com. Tel. 0105115682, 040-3306194 and 040-3337614 5 Assistant Prof. Structural Engineering, Tanta University, Egypt. 1

2. EXPERIMENTAL PROCEDURE A comprehensive testing program on axially as well as small eccentrically loaded columns confined with CFRP was carried out. The test program consists of three groups as shown in Table (1), these groups contain 18 RC columns. The specimens diameter was 150mms while its heights were varied. Four different column heights were taken in this study such as: 300mms, 610 mms, 915 mms and 1220 mms. The heights to diameter ratios (slenderness ratio), H/D were 2, 4, 6 and 8. The steel ratio of longitudinal reinforcement were constant for all columns and equal to 2.2% with yield stress 365MPa. The used concrete was made from a mix of ordinary Portland cement, natural sand, and gravel with the mixture proportion shown in Table (2). The average compressive strength of the concrete (unconfined concrete strength) was determined to be 20MPa based on the on the compressive test result of six standard cylinders (150x300mm). Nine specimens were confined with one layer of full horizontal wrapping of CFRP, while the other specimens were control (unconfined). The properties of CFRP wrapping are shown in Table (3). The tested specimens were loaded to failure under increasing compressive load, with variable load eccentricity. The Load eccentricity, e, was taken 0D, 0.05D and 0.1D, where D is the column diameter. The columns were tested under monotonically increasing axial compression with constant end eccentricity. Load was applied through steel end plates and adjustable rollers pin support that provide a constant end eccentricity. Three pin supports were manufactured specially for the present work. Steel loading frame with hydraulic jack was used to apply vertical load on columns, while the prisms and cylinders were tested by Amsler, 3000kN compression testing machine. Fig. (1) shows test setup for axially loaded columns and Fig. (2) shows test setup for eccentrically loaded columns. The capacity of the hydraulic jack applying the vertical load was 1100kN. Load cell with capacity of 950kN and accuracy of 0.1kN was used. The value of applied load was appeared automatically on special monitor connected to the load cell. Columns were tested using an incremental loading procedure. Approximately twenty load increments were required for unconfined columns while thirty load increments were required for confined columns. Each load increment was applied in period of about two minute. The load was kept constant at each load stage for about ten minutes to allow measurements and observations. The lateral strains in the specimens were measured by using two 60 mm surface gauges placed at 180 0 apart attached at the midheight of each specimens. Another two 30 mm surface gauges were attached at the surface of CFRP. Moreover, to measure axial strains, linear variable displacement transducers (LVDT s ) were placed at 180 0 apart around the specimens. The LVDT s used have a maximum range of (50mms) and capable of recording (0.01mms) displacement. The results from LVDT s were compared with those of the electrical gauges. It was observed that for all practical purposes, the average axial strains measured by LVDT s were as accurate as the measurements made with the electrical strain gauges. Lateral deflection of eccentrically loaded columns was measured at mid height of the columns using LVDT s. Table (1) Overview of the tested columns Groups Specimen No. D, mms H, mms Steel Ratio, µ % e/d G 1,1u 150 1220 2.22 0 G 1,1c 150 1220 2.22 0 G1 G 1,2u 150 1220 2.22 0.05 G 1,2c 150 1220 2.22 0.05 G 1,3u 150 1220 2.22 0.1 2

G 1,3c 150 1220 2.22 0.1 G 2,1u 150 915 2.22 0 G 2,1c 150 915 2.22 0 G 2,2u 150 915 2.22 0.05 G 2 G 2,2c 150 915 2.22 0.05 G 2,3u 150 915 2.22 0.1 G 2,3c 150 915 2.22 0.1 G 3,1u 150 610 2.22 0 G 3,1c 150 610 2.22 0 G 3 G 3,2u 150 610 2.22 0.05 G 3,2c 150 610 2.22 0.05 G 3,3u 150 610 2.22 0.1 G 3,3c 150 610 2.22 0.1 D= Column diameter, H= Column height, e= Load eccentricity, u= Unconfined columns, c= Confined columns Table (2); Mixture proportion of concrete (percentage by weight) Sand Gravel Cement Water 28.7 48.8 15.2 7.3 Table (3) Mechanical Properties of CFRP Fiber type High strength carbon fibers Fiber orientation Young s modulus Fabric design thickness Tensile strength 0 o unidirectional 233.333GPa 0.16mm 3500MPa Elongation at break 1.5% 3 Fig. 1 Test setup for axial loading Fig. 2 Test setup for eccentric loading

3. TEST RESULTS AND DISCUSSIONS 3-1 Test Observations and Modes of Failure For Axially loaded columns the failure of unconfined columns was generally marked by the appearance of vertical cracks at about 90% of the ultimate load followed by crushing of concrete at or near the midheight of the specimen. There was no indication of any reinforcement buckling until the concrete was completely crushed. No overall buckling as result of slenderness was noticeable, as the length effect were insignificant within the range of (H/D) ratios studied. Failure of confined specimens was generally marked by sudden fracture of the CFRP wrapping at or near the midheight of the specimen. Failure near the top and bottom edges was not detected. Sounds heard during the early to middle stages of loading were attributed to the microcracking of concrete and shifting of aggregates. Snapping of the CFRP layers could be heard near the end of the loading process. For eccentrically loaded columns the failure of unconfined columns was generally marked by crushing of concrete at compression side at or near the midheight of the specimen. There was no indication of any reinforcement buckling until the concrete was completely crushed. The observed behavior of the confined columns was similar to the unconfined columns up to the peak load of unconfined columns. Increases in the lateral deflection of confined columns resulted in the concrete failing in compression and rupturing the FRP confining jacket at approximately mid-height. Tensile rupture of the composite was only caused by a significant increase in the lateral deflection beyond the peak load. The deflected shape of the columns at peak load was symmetrical and there was no local buckling in the columns. The only signs of distress to the composite were the heard sounds and the large lateral deflections of the columns. Inspection of the concrete core after failure showed the concrete to be of a highly fissured nature, but re-compacted under the high triaxial state of stress. The modes of failure of some unconfined and confined columns with eccentricity e/d=0.05 are shown in Figs. 3 and 4. G2,2u 3-2 Axial strain The ultimate load and axial strain of all columns are presented in Table (4) and Fig. (5). For unconfined columns the load-vertical strain relationship was approximately seconddegree curve with ultimate strain of about 0.0025. The behavior of the confined columns was similar to the unconfined columns up to the peak load. A review of response curves indicates a significant enhancement in strength and ductility of concrete confined with CFRP. Furthermore, unlike steel-encased concrete, response of CFRP-confined concrete was bilinear with no descending branch. The response consists of three regions. In the first region, behavior was similar to unconfined column, since lateral expansion of the core was insignificant. With the increase in microcracks, a transition zone was entered where the CFRP jacket exerts a lateral pressure on the core to counteract the stiffness degradation of concrete. Finally, a third region was recognized in which the CFRP jacket was fully activated, and the stiffness was generally stabilized around a constant rate. The response in this region was mainly dependent on the stiffness of the CFRP jacket. 4

Table (4): Summary of test results Groups Spec. No. Cracking Load P cr kn Ultimate Load P u kn Ultimate Vertical Strain Ultimate Lateral Strain Ultimate Lateral deflection, mm ε Min. ε Max. ε Min. ε Max. G 1,1u 415 462 0.002 0.002 0.0004 0.00039 0.0 G 1,1c ---- 772 0.028 0.028 0.0149 0.01480 0.0 G 1,2u 386 420 0.0015 0.0024 0.0003 0.00042 0.40 G1 G 1,2c --- 700 0.0180 0.029 0.0144 0.0146 1.15 G 1,3u 360 393 0.0012 0.0028 0.0002 0.00042 0.99 G 1,3c --- 588 0.0110 0.030 0.0149 0.0148 2.85 G 2,1u 395 442 0.0021 0.0021 0.0004 0.0004 0.0 G 2,1c --- 720 0.0210 0.0200 0.0144 0.00146 0.0 G 2,2u 365 402 0.0016 0.0026 0.0149 0.0146 0.65 G2 G 2,2c --- 640 0.012 0.030 0.0148 0.0148 2.00 G 2,3u 345 381 0.001 0.0028 0.0002 0.0006 1.37 G 2,3c --- 510 0.011 0.030 0.0145 0.0146 4.54 G 3,1u 385 421 0.0022 0.0021 0.00041 0.00041 0.0 G 3,1c --- 658 0.0175 0.0174 0.0149 0.150 0.0 G3 G 3,2u 355 391 0.0017 0.0028 0.0003 0.0005 1.11 G 3,2c 565 0.0108 0.0180 0.0148 0.0148 3.20 G 3,3u 359.2 0.0012 0.0030 0.00025 0.00063 2.30 G 3,3c --- 420 0.0076 0.0190 0.0150 0.0150 6.80 3-3 Load-deflection curves The load-deflection curves for cases of e/d=0.05 and 0.1 are shown in Figs. (6) and (7), respectively. As the axial load increases, larger lateral deflections are observed for columns with H/D equal to 6 and 8. It is noticed that, the columns with bigger values of e/d have bigger values of lateral deflection of the same H/D ratio. That is because, the compressive strain increases in one side of the column than that in the other side. This action lead to increase in curvature and consequently increase in lateral deflection. As mentioned before, the lateral deflection of confined columns was very big with respect to that of unconfined columns. That is because, the value of lateral deflection is mainly depend on the curvature, that in tern depends on the deference between the maximum and the minimum strains developed on either sides of the column. The differences between maximum and minimum strains for confined columns was about ten time of that for unconfined columns. 5

Load kn 900 800 700 600 500 Unconfined Column H /D = 4 Unconfined Column H /D = 6 400 Unconfined Column H /D = 8 300 Confined Column H /D = 4 Confined Column H /D = 6 200 Confined Column H /D = 8 100 Axial Strain 0 0 0.005 0.01 0.015 0.02 0.025 0.03 Fig. 5 Load-Axial strain curves for the tested columns Load kn 800 700 600 500 400 300 200 Confined column H/D = 8 Unconfined Column L/D = 4 Unconfined Column L/D = 6 Unconfined Column L/D = 8 Unconfined column H/D = 8 Confined Column L/D = 4 Confined Column L/D = 6 Confined Column L/D = 8 100 Deflection mm 0 0 1 2 3 4 5 6 Fig. 6 Load deflection curves for the tested columns " e/d = 0.05 " Load kn 700 600 H/D = 2 H/D = 6 500 400 300 200 100 H/D = 8 Unconfined Columns H/D = 4 Unconfined Columns H/D = 6 Unconfined Columns H/D = 8 Confined Columns H/D = 4 Confined Columns H/D = 6 Confined Columns H/D = 8 Deflection mm 0 0 2 4 6 8 Fig. 7 Load-Deflection curves for the tested columns "e/d = 0.10" 3-4 Ultimate load The effect of load eccentricity on ultimate load for different values of H/D for unconfined and confined columns is illustrated in Table (4) and Fig. (8). It is clear that, the effect of load eccentricity on ultimate load of confined columns is greater than that of the unconfined columns, and this effect is very sensitive to H/D ratios. The ultimate load of confined and unconfined columns (for H/D=4) reduced by about 36% and 14.7%, respectively, by increasing load eccentricity from 0.0D to 0.1D. The column load gain due to confinement is defined by the following equation: Pu, confined Pu, unconfined Load gain = x100 (1) P u, unconfined 6

Table (4) shows the load gain for confined columns for different ratios of H/D and e/d. It is concluded that the procedure of confined columns couldn t use for unconfined columns, in case of small eccentricity. Therefore, a new accurate design equation take the small eccentricity as well as size effect is essential. Table (4) Load gain of confined columns Load Eccentricity, e Load gain% H/D 4 6 8 0.0D 67.1 62.8 56.3 0.05D 65.1 59.2 44.5 0.1D 49.6 33.8 16.9 Ultimate Load kn 900 800 700 600 500 400 300 200 100 0 H/D = 4 H/D = 8 H/D = 4 H/D = 6 H/D = 8 Unconfined Columns Confined Columns 0 0.02 0.04 0.06 0.08 0.1 0.12 Fig. 8 Effect of load eccentricity on ultimate load of confined and unconfined columns e/d 3-5 Effect of slenderness ratio on ultimate load From experimental work it was observed that no overall buckling for studied H/D ratios. Table (3) and Fig. (8) show that the ultimate load decreases with the increase H/D and e/d ratios. It is clear that, the effect of slenderness ratio on ultimate load of confined columns is greater than that on unconfined columns, and this effect is very sensitive especially with the increase of e/d ratios. Thus the column will be subjected to a total moment given by Eqn. (2). M total where : = P( e δ = R(1 - cos R = H / φ + δ ) P = applied load, e φ ) 2 φ = angle of curvature o H = ( ε c,max ε c,min ) rad D 2H 2 Then, δ = sin ( φ / 4), φ o = initial see Fig. 9. eccentiric ity and δ = (2) lateral deflection 3-6 Effect of slenderness ratio on ultimate confined stress and strain Four different H/D ratios were taken in this study, such as:2, 4, 6 and 8. It was founded that the ultimate confined strength of the columns affected by the slenderness ratio as shown in Fig. (10). The ultimate stress and strain of confined columns with any slenderness ratios can be obtained by regression analysis of test results as related to that for concrete cylinder (i.e. H/D=2) in the following form of Eqns. (3) and (4): 7

f ε cu cu = f = ε cu,2:1 cu,2:1 ( 0.0012 ( H (0.0063 H D D ) 2 2 0.0535 ( H 0.1475 / D ) + 1.1 + 1.275 ) Where: f cu,2:1 = ultimate confined stress of concrete cylinder ε cu,2:1 = ultimate confined strain of concrete cylinder H D ) (3) (4) P e o ε c,min ε c,max φ φ/2 δ H R Fig. 9. Additional moment due to lateral deflection Relative Concrete Strength (fcu/fcu,2:1) No rm ali ze d Ult im ate 1 1.1 0.9 0.8 0.7 0.6 0.5 H/D Ratio 0.4 2 3 4 5 6 7 8 9 Fig. 10 Effect of slenderness level on ultimate confined stress of CFRP confined concrete columns P e o 4. PROPOSED EXPRESSION OF ULTIMATE LOAD OF FRP-CONFINED RC SHORT COLUMNS The failure load of FRP-confined concrete columns with small eccentricity (according to E.C.O.P) can be obtained by regression analysis of test results taking the H/D ratio in account in the following form of Eqn. (5): P u = k1k2 Ac fcu + As f y (5) Where : P u = failure load, A c = cross sectional area of concrete column, A s = cross sectional area of longitudinal reinforcement, f y = yield stress of steel, f cu = ultimate confined stress of concrete, k 1 = strength reduction factor due to size effect, k 2 = strength reduction factor due to small load eccentricity. And, k 1 = 0.00120 (H/D) 2 0.05350(H/D) + 1.1 (6) k 2 = -0.0052 (H/D) 2 + 0.0430 (H/D) + 0.811 for e/d= 0.05 (7) k 2 = -0.00560 (H/D) 2 + 0.0237 (H/D) + 0.710 for e/d= 0.10 (8) 8

For purpose of design, the reduction factors (k 1 *k 2 ) of concrete should not exceed 0.67f cu /γ c 0.447 and strength reduction factor of steel is 0.87 (according to E.C.O.P) Table (5) and Fig. (11) provides an iterative values of the strength reduction factors k1 and k2 as a function of e/d and H/D that can be easily applied to practical situation. Table (5) Strength reduction factor for Load eccentricity and H/D Ratio H/D 4 5 6 7 8 9 K 1 0.905 0.863 0.822 0.784 0.7488 0.716 e/d=0.05 0.899 0.896 0.880 0.857 0.822 0.776 K 2 e/d=0.10 0.715 0.689 0.651 0.601 0.541 0.470 0.9 k2 e/d = 0.05 0.8 k2 = -0.0052(H/D) 2 + 0.043(H/D) + 0.811 0.7 0.6 e/d = 0.1 k2 = -0.0056(H/D) 2 + 0.0237(H/D) + 0.71 0.5 0.4 0.3 0.2 0.1 H/D 0 2 3 4 5 6 7 8 9 Fig. 11 Strength Reduction Factor (k2) Due to Load Eccentricity To investigate the validation of the proposed formulation the circular column illustrated in Fig. (12) is investigated. Due to aggressive environment and creep rupture, Ref.[8] recommended to multiply the ultimate strength and strain of CFRP by a reduction factors equal to 0.85 and 0.55 respectively. The ultimate tensile strength of CFRP= 0.85x0.55x3500= 1636MPa. The ultimate strain of CFRP= 0.85x0.55x0.015= 0.007mm/mm <0.004 Ref. [8]. The corresponding ultimate design strength of CFRP, f ujd = 0.004E j = 0.004x233333= 933MPa. From Table (5) k 1 = 0.759 and k 2 = 0.833. But k 1 k 2 >0.35, then taken 0.35. Using Eqn. (5) with reduction factors, it can be calculate the ultimate confined strength of concrete at required ultimate load 1800kN, as: 1200000= 0.35x96211f cu +0.87x791.7x360, then f cu = 28.09MPa. From Ref. [12], it can be calculate the ultimate lateral pressure of CFRP, f LU, as: f cu =f co +5(f LU ) 0.8, 28.09= 25+5(f LU ) 0.8, then f LU = 0.811 MPa. The number of CFRP plies can obtained from the following equation: f LU = 0.5k e ρ j f ujd, where k e = 1 for full wrapping. But ρ j = 4n t j /D, where, n= number of plies and t j = CFRP thickness. n= 1.5, then use 2 continuous CFRP plies to increase the ultimate column load of about 30%. H e = 2700mm H e =2700mm 9 D= 350mm D= 350mm DATA OF GIVEN COLUMN REQUIRED COLUMN The ultimate column load= 900kN Increase ultimate load to 1200kN. e/d=0.05 according to E.C.O.P Use full CFRP confinement taking the H e /D=7.7< 8 (short column) aggressive environment and creep rupture Unconfined concrete strength, f co =25MPa, into consideration. Use data given in Table 3 A s,long = 7φ12 (791.7mm 2 ), f y =360MPa Fig. 12 Illustrated example

5. CONCLUSIONS The present research has investigated the real behavior of axially FRP-confined concrete columns taking the effect of small eccentricity in accordance to most international codes, in contrary most researches that take the load eccentricity equal to zero. The result of experimental program has been reported in details. Findings from this study show that: 1. The use of fiber composites is an efficient means of providing confinement of concrete for strength and ductility enhancement. 2. Under relatively small load eccentricities, e/d from 0.05 to 0.10, the behavior of eccentrically loaded FRP-confined columns demonstrate a completely different behavior specially the load carrying capacity. 3. A proposed equations to calculate the ultimate confined stress and strain as a function if slenderness ratio are suggested. 4. The present paper proposed an equation to be calculate the failure load of reinforced concrete FRP-confined columns taking small eccentricity and slenderness ratio into account. ACKNOWLEDGMENT The work described in this paper was conducted by fifth author as a part of his Ph.D studies at the University of Tanta under the supervision of the other authors. The experimental work was performed in the Reinforced Concrete and Heavy Construction Laboratory of the Faculty of Engineering, Tanta University. REFERENCES 1 Amir Z. Fam and Sami H. Rizkalla State of the art report on stay in place FRP formwork, submitted to ACI Committee 440 J, 1999. 2 Amir Mirmiran and Mohsen Shahawy Behavior of Concrete Columns Confined by Fiber Composites ASCE Vol. 123 No. 5 May 1997. 3 Ahmed S. H. and Shah, S. P., Complete Triaixial Stress-Strain Curves for concrete ASCE, Vol. 108, April 1982 ; pp. 728-742 4 ACI 318-95, ACI 318R-95, Building Code Requirements for Structural Concrete (ACI 318-95) and Commentary (ACI 318R-95), America Concrete Institute, 1995. 5 Design of Concrete Structures for Buildings Canadian Standards Association, 1985 6 Euro Code 2 : Design of Concrete Structures, 1992. 7 Egyptian Code of Practice for Reinforced Concrete Structures, 2001. 8 Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures, Reported by ACI Committee 440, Revised 24 January (2000). 9 Jurgen Becque Analytical modeling of concrete columns confined by FRP, M.Sc. Thesis, University of Manitoba, Winnipeg, Manitoba, Canada 2000. 10 Mirmiran, A., and Shahawy, M. Behavior of concrete columns confined by fiber composites J. Struct. Engrg., ASCE, 123 (5) 1997, pp. 583-590. 11 Mirmiran, A., Shahawy, M., Samaan, M., El Echary, H., Mastrapa, J. C., and Pico, O. Effect of Column Parameters on FRP-Confined Concrete Journal of Composites for Construction, ASCE, Vol.2, No. 4, November 1998, pp. 175-185. 12 Mohamed, H. M., Tarek, M. F., Mohamed, A. K., Sami H. R. and Kamal, N. G. Behavior and Development Model for External FRP Filament of Axially Loaded Columns, ASCE-ECS, Cairo- Egypt, April, 2002. 13 State-of-the-Art Report on Fiber reinforced Polymer Structurally Integrated Stay-in- Place Formwork for Concrete Members, Prepared by ACI Committee 440 J, 2000. 10