European Modular Cultivation System (EMCS)

Similar documents
I n the run-up to launching and operating

HOW TO BUILD A NANORACKS PAYLOAD: NANOLABS

Questions From / Answers To Potential Proposing Community. Most Current Update: Thursday, July 1, Question Number. Date Received.

NASA ISS Research Academy and Pre-Application Meeting. Erin Beck Mission Integrator August 4, 2010

How Long Do You Need To Achieve Your Scientific Objectives?

Human Spaceflight, Microgravity and Exploration

International Space Station Carbon Dioxide Removal Assembly (ISS CDRA) Concepts and Advancements

MICROGRAVITY EFFECTS ON HUMAN PHYSIOLOGY: CIRCULATORY SYSTEM

The Space Shuttle: Teacher s Guide

WEIGHTLESS WONDER Reduced Gravity Flight

TOPO Trajectory Operations Officer

Vascular Tissue Challenge Official Rules

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Human Spaceflight, Microgravity and Exploration NEWS MAY 2007

FAQ. Q: What do you do on the International Space Station (ISS)? Q: How fast and how high do you go? Q: How long are the missions?

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

R&D Support Services. Ad Astra Rocket Company

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

NJ Physics Professor Has the 'Right Stuff' Valorie Sands

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Mass vs. Weight Careers In Space

SPACE OPERATIONS, INC. Executive Summary October 2013

BBC LEARNING ENGLISH 6 Minute English Could you be an astronaut?

NASA S EFFORTS TO MAXIMIZE RESEARCH ON THE INTERNATIONAL SPACE STATION

Space Aquariums. ASEN5519 Space Hardware Design Fall 2003 Helen Carson (CATECS)

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Extending the Operational Life of the International Space Station Until 2024

Space Exploration. A Visual History. Philip Stooke

The European Drawer Rack for the ISS and its Scientific Capabilities

IAC-12-B3.4-B6.5.8 DECLIC OPERATIONS AND GROUND SEGMENT AN EFFECTIVE WAY TO OPERATE A PAYLOAD IN THE ISS

2014 Beijing - The Russian Made Summer Camp of 2008

Cooking at the Speed of light!

imagine SOLAR AIR CONDITIONING MADE EASY

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Space Launchers. Mastering technologies of cryogenic tanks and associated equipment. ADVANCED TECHNOLOGIES

Freezers - Ultrafreezers. Platilab & Irilab Series

ESA s Data Management System for the Russian Segment of the International Space Station

THE NEWCASTLE UPON TYNE HOSPITALS NHS FOUNDATION TRUST SAFE USE AND STORAGE OF LIQUID NITROGEN AND SOLID CARBON DIOXIDE (DRY ICE)

Space Launchers. Mastering technologies of cryogenic tanks and associated equipment. ADVANCED TECHNOLOGIES

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

PRESENTATION SPACE MISSIONS

Candle Flame in Microgravity

Die Internationale Raumstation Europas Labor im All

The Sky is No Longer the Limit. A Presentation on our 2U CubeLab by Valley Christian High School Students

S/5 Anesthesia Monitor. The clinician s choice

DEOS. Deutsche Orbitale Servicing Mission. The In-flight Technology Demonstration of Germany s Robotics Approach to Service Satellites

RiMatrix S Make easy.

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Process Optimization to Identify Potential Human Error in Flight Hardware Processing

Vakulab PL. All-rounder for laboratory and research. Long life time and short cycle times. Space saving and ergonomical

moehwald Bosch Group

NASA's Annual Research and Development Conference - In Chicago


Natural Alternatives in the Refrigeration & Air Conditioning Sectors

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

SpaceÊ ShuttleÊ Program Artifacts

Mid InfraRed Instrument (MIRI) Cooler Subsystem Design

ANNEX 17 DRAFT AMENDMENTS TO SOLAS REGULATIONS II-2/4 AND II-2/16. Part B Prevention of fire and explosion

Transformers from 25va to 500kva. Standard despatch in days not weeks

Satellites and Space Stations

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

ESA Contribution to Astro-H

Nodes are corridor links that will

OZW30. Central Unit SYNERGYR

HELIAL liquefiers. Range of automatic helium liquefiers.

Split units TH with hermetic compressors

Elgin Fire Department

Dry Ice Use And Hazards

Elemental analyzer multi EA 5000

Development of a Gravity-Insensitive Heat Pump for Lunar Applications

5 Years experience of Columbus Ground Segment Operations

EDUCATOR S RESOURCE GUIDE

REMARKS FOR ADMINISTRATOR BOLDEN NATIONAL CONTRACT MANAGEMENT ASSOCIATION GOVERNMENT CONTRACT MANAGEMENT SYMPOSIUM. Nov. 19, 2013

ROYAL CANADIAN AIR CADETS PROFICIENCY LEVEL TWO INSTRUCTIONAL GUIDE SECTION 6 EO C IDENTIFY PARTS OF A ROCKET PREPARATION

BUILDING TRANSATLANTIC PARTNERSHIPS IN SPACE EXPLORATION THE MPCV-SM STUDY

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

IAC-08-B PROPOSAL FOR MODIFICATION OF ISS. Japan,Tokyo

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Transport and Mailing Systems

Off Site Sample Storage Specialists

Fundamentals of Space Medicine. viii

How To Use A Pharmacy Picker

19/02/2014. Bed Bug Control in the United Kingdom. Contamination. Key UK Requirements -Why do we Need to Control Pests? Eradicate/control species that

Syllabus for Biology 2402 Human Anatomy & Physiology 2 [This is a generic syllabus. Each instructor will give a syllabus customized for their course.

APC APPLICATION NOTE #92

3-5 Ka-band High Power Multi-port Amplifier (MPA)

Elements of Physics Motion, Force, and Gravity Teacher s Guide

BB-18 Black Body High Vacuum System Technical Description

A long time ago, people looked

Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions

COMBIMASS. Technical Data COMBIMASS eco-bio +

Micro Motion 3098 Gas Specific Gravity Meter

ISS L.A.B.S. Educator Resource Guide

Satellite Power Systems

Dawn - Overview, Science Objectives, Mission Progress. Hap McSween For PI Chris Russell

Gas Exchange Graphics are used with permission of: adam.com ( Benjamin Cummings Publishing Co (

Temperature control solutions to help you improve business performance

ACB SERIES MAIN CHARACTERISTICS OF THE STERILIZER : CONTINUOUS STERILIZERS

INTA Renewable Energy Area activities

Transcription:

European Modular Cultivation System (EMCS) The EMCS will be flown to the ISS on the STS-121 Shuttle mission. It is an ESA experiment facility dedicated to biological experiments, with several experiments already planned dealing primarily with the effects of gravity on plant cells, roots and physiology. These types of experiments will help to provide new knowledge about growth processes in plants and have the potential for making improvements in food production techniques on Earth and in space. This will hold benefits for astronauts on longer-term missions such as an expedition to Mars as part of ESA s Aurora programme. Experiments with insects or amphibia and studies with cell and tissue cultures are foreseen in the EMCS as well. The ESA astronaut will be involved in the accommodation of the EMCS in an Express Rack in the US Destiny Laboratory. During flight, equivalent ground control experiments may be performed inside dedicated experiment Reference Models, one located at the Norwegian User Support and Operations Centre in Trondheim, Norway, the other at the NASA Ames Research Center in the United States. The flight unit also provides the potential for 1g control experiments on board the ISS. ESA astronaut Reinhold Ewald inserting an experiment container into the EMCS Engineering Model. (Image: ESA) The EMCS consists of a gas tight incubator where the humidity and composition of the air, temperature, light, water supply and a number of other parameters will be closely monitored and controlled. It contains two centrifuges, each one with space for four experiment containers. Each experiment container has an internal volume of 60 x 60 x 160 mm with a transparent cover. White light or infrared LED illumination is available for each single container. Video cameras are available for experiment observation. Each centrifuge can be programmed individually to provide from 0.001g up to 2g in weightlessness. Video, data and command lines will allow experiment control by the ISS crew and from the ground. Plant Cultivation Chamber inside experiment container as part of Experiment Reference Model hardware. The first experiments to take place within the EMCS include molecular and physiological analyses of a type of cress (Arabidopsis), and the short- and long-term effects of weightlessness on the development of rotifers and nematodes. The scientific utilisation of the EMCS will be carried out in co-operation with the NASA Ames Research Center. EMCS is developed under ESA contract by an industrial team led by the company EADS Space Transportation (Friedrichshafen, Germany). Although it is provided as part of a barter agreement with the United States, European access is also possible.

MELFI (Minus Eighty - degrees - Laboratory Freezer for the ISS) The Minus Eighty (Degrees) Laboratory Freezer for ISS (MELFI) will also be flying to the ISS on the STS-121 mission. It is a rack-size facility which will provide the Space Station with refrigerated volume for storage and fast freezing of life science and biological samples. It will also ensure the safe transportation of conditioned specimens to and from the ISS by flying in fully powered mode in the Multi-Purpose Logistic Module (MPLM) installed in the Shuttle s cargo bay. MELFI was designed for an operational lifetime of 10 years, with each continuous mission lasting up to 24 months. MELFI has also been qualified for 15 launches. allows maintaining the selected temperature for up to eight hours even without power. The present launch configuration of MELFI includes the MELFI On-Orbit Commissioning Experiment (MOOCE), also developed by ESA. This will be carried out few weeks after installation to monitor the thermal behaviour of one of the compartments. MELFI will be immediately used to store samples processed in e.g. the Human Research Facility. The ESA astronaut will be involved in commissioning activities when it arrives at the ISS and will also use the facility for storage of samples from the physiology experiments CARD and Immuno. The samples can be stowed in four compartments (dewars), whose temperature can be independently controlled at different levels (-80, -26, +4 o C). Each dewar is a cylindrical vacuum insulated container, having an internal volume of about 75 litres, divided internally in four sectors. Each sector hosts one tray, which can be extracted without disturbing the samples in the other three. MELFI provides standard accommodation hardware for the insertion of samples of different shapes and sizes. The MELFI cooling system has been the subject of a very intense technology development programme. In particular, the sophisticated cooling machine, which is able to provide the required temperatures while using very limited power (less than 1 kw in the worst case). It is mounted within a complex enclosure, called the Cold Box, in order to minimize any thermal loss and contamination of the cooling fluid. The Cold box contains in addition two heat exchangers, consisting of a total of 10 km of piping. The cooling machine is designed to be an Orbital Replacement Unit. It can be dismounted from the Cold Box with the help of dedicated tools, in less than eight hours, allowing the preservation of specimen even in case of machine failures. In order to improve the reliability and availability of the freezer, the present launch configuration includes a spare electronic unit and a spare cooling machine. The cooling fluid is high purity nitrogen. All the lines and components through which the nitrogen flows are double walled, with high vacuum and multilayer insulation in between the two walls. This Second MELFI flight unit at the Kennedy Space Centre in 2004 with Expedition 11 Crew: Sergei Krikalev (background) and John Phillips (foreground). Upon arrival to ISS, MELFI will be transferred to its location within the US Destiny Laboratory and will be ready to start its service life. MELFI was developed by the European Space Agency (ESA) in the frame of international barter agreements. Two flight units have been supplied to NASA and one the Japan Aerospace Exploration Agency (JAXA). In addition, ESA has delivered to NASA ground units for training and experiments preparation and will provide the necessary spares and sustaining engineering to maintain MELFI for up to 10 years of operations. EADS- ASTRIUM (France) led the Industrial Team including L Air Liquide (France), LINDE (Germany), Kayser-Threde (Germany) and ETEL (Switzerland).

Microgravity Science Glovebox Pedro Duque during operations for the PROMISS experiment in the Microgravity Science Glovebox during the Cervantes mission. 20 October 2003. (Image: NASA) The Microgravity Science Glovebox was the first European ISS-Rack Facility that was launched to the International Space Station in 2002. The device will allow astronauts aboard the ISS to perform a wide range of experiments in a fully sealed and controlled environment, completely isolated from the rest of the Station. It is currently installed inside the US Destiny laboratory, though will be transferred to the European Columbus laboratory following its launch in 2007. It has been used successfully during several Soyuz Missions to perform Physical Sciences experiments and was recently used by Bill McArthur, the ISS Expedition 12 Commander, to perform the PROMISS-4 experiment, an experiment that was historically developed in the frame of the Belgian Odissea Mission in 2002 with ESA astronaut Frank De Winne, and has evolved since then to a versatile instrument for the protein crystallisation science community. When the STS-121 crew arrive at the ISS they will carry out maintenance on the Microgravity Science Glovebox. The main window and seals will be exchanged to ensure the extension of its certification. Several European payloads, currently under development, will be installed and operated within the Microgravity Science Glovebox in the next years.

Percutaneous Electrical Muscle Stimulator (PEMS) The Percutaneous Electrical Muscle Stimulator. (Image: ESA) The Percutaneous Electrical Muscle Stimulator (PEMS) will be flying to the ISS on the STS-121 Shuttle mission and will be checked out by the ESA astronaut as part of his scheduled activities. PEMS is a self-contained device, the purpose of which is to deliver electrical stimulation to nonthoracic muscle groups of the human test subject, thereby creating contractile responses from the muscles. Its main purpose is to support human neuromuscular research. The device can provide either single pulse or pulse trains with two selectable pulse widths and variable amplitudes. PEMS is portable, and designed to be used in conjunction with other physiological instruments, in particular the Muscle Atrophy Research and Exercise System (MARES). PEMS will be checked out and commissioned in the US Laboratory. Eventually PEMS should be used together with the MARES in the European Columbus laboratory after it arrives at the ISS, currently scheduled for 2007. The Percutaneous Electrical Muscle Stimulator was developed by the Swiss company Syderal. This is a second generation of the PEMS device, the first generation PEMS having flown on the Space Shuttle in 1996.

Pulmonary Function System (PFS) The Pulmonary Function System is an ESAdeveloped device that analyses exhaled gas from astronauts' lungs to provide near-instant data on the state of crew health. It was launched to the ISS on the STS-114 Return to Flight mission and was successfully commissioned by the Expedition 11 and 12 Crews. The ESA-developed PFM/PAM units for the Pulmonary Function System in operational mode Seven different gases can be measured simultaneously, with several measurements being made within a single breath. This will provide a lot of information about the subject's lung function, blood flow and entire cardiovascular system. PFS will also be subject to a software and hardware upgrade, thereafter being used to perform the mandatory Personal Fitness Evaluation with Oxygen Uptake Measurements (OUM) from crew member medical operations. During the Astrolab mission the ESA astronaut will use the PFS to perform the CARD experiment. The PFS is a collaboration between ESA and NASA in the field of respiratory physiology instrumentation. This is accommodated in the NASA Human Research Facility located in the US Destiny Laboratory on the ISS. The PFS consists of four separate components, two developed by ESA: The Pulmonary Function Module (PFM) and the Photoacoustic Analyser Module (PAM); and two developed by NASA: the Gas Delivery System and the Gas Analyser System for Metabolic Analysis Physiology. These four elements can be combined in two different configurations to provide a variety of different measurements. PFM/PAM mounted inside the second Human Research Facility rack (HRF-2) The PFM/PAM Unit consists of the Respiratory Valve Unit, with associated flow-meters, rebreathing bag, etc., and an electronics unit. The electronics unit is accommodated in a standard ISS drawer in the Human Research Facility rack, though there is a mode of operation in which this drawer is removed from the Human Research Facility rack and operated externally. PFS is the first flight hardware developed by the Microgravity Facilities for Columbus Programme as part of the European Physiology Modules project, originally planned for launch in the Columbus Laboratory. The hardware was developed for ESA by the Danish company Damec. Following great interest shown by NASA, ESA was offered an earlier flight opportunity to launch the PFS as part of the second NASA Human Research Facility to be installed on the ISS. The PFS flew to the ISS on the STS-114 Return to Flight Shuttle mission. The PFS will be relocated into the Columbus laboratory when it arrives at the ISS in 2007.