Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone



Similar documents
Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Effect of Metallic Materials on SAR

Specific Absorption Rate (SAR) in the head of Tablet user's

Millennium Product Inc. Model: Cell Shield / Zorb

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

How To Understand The Safety Of A Cell Phone (Cell Phone)

ARIB TR-T V Specific Absorption Rate (SAR) requirements and regulations in different regions

SAR Simulation in Human Head Exposed to RF Signals and Safety Precautions

Thermal Effects of Mobile Phones

Assessment of SAR in a human exposed to GSM electromagnetic fields

Human Exposure Limits

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

Electromagnetic Field Safety

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D Kamp-Lintfort

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

Wireless Broadband: Health & Safety Information

Wideband Dual Segment Rectangular Dielectric Resonator Antenna Terminate in Bio-Media

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues

Low SAR planar antenna for multi standard cellular phones

THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE. Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112

MUCH work has been reported on determining the specific

ASSESSMENT OF HUMAN HEAD EXPOSURE TO WIRELESS COMMUNICATION DEVICES: COMBINED ELECTROMAGNETIC AND THERMAL STUDIES FOR DIVERSE FREQUENCY BANDS

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS

Human exposure to RF

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

For many years the general public

THE FIRST ROMANIAN SAR MEASUREMENT FACILITY WILL BE OPERATIONAL IN 2009

Performance Analysis of Mobile Phone Radiation Minimization Through Characteristic Impedance Measurement

The Existing Public Exposure Standards Cindy Sage, MA Sage Associates, USA

Human Exposure to Outdoor PLC System

Man-Faï Wong 1 and Joe Wiart 1


SAR Test Report: Type Number FAD BV; FCC ID PY7FD022012; IC 4170B-FD022012

A study on specific absorption rate (SAR) due to non-ionizing radiation from wireless/telecommunication in Bangladesh

RICHARD T ELL ASSOCIATES,INC.

Electromagnetic Radiation towards Adult Human Head from Handheld Mobile Phones

Mobile Phone SAR Analysis through Experimental and Numerical Simulation

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets

MINIMALLY INVASIVE THERMAL THERAPY FOR CANCER TREATMENT BY USING THIN COAXIAL ANTENNAS

Exposure Assessment of Smartphones and Tablets

Exposure Assessment of a High-Resonance Wireless Power Transfer System under the Misaligned Condition

Selected Radio Frequency Exposure Limits

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

Body SAR and EU. B. Derat

Annex to the joint statement: Exposure of the general public to radiofrequency fields

SAR REDUCTION IN HUMAN HEAD FROM MOBILE PHONE RADIATION USING SINGLE NEGATIVE META- MATERIALS

CITY UNIVERSITY OF HONG KONG. A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models

Interaction of Mobile Phone Waves with Tissues of Skeletal Muscles and Bone of Human Beings

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)

Consequence for a dualband application

1 Introduction. JS'12, Cnam Paris, 3-4 Avril Ourouk Jawad 1, David Lautru 2, Jean Michel Dricot, François Horlin, Philippe De Doncker 3

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

SAMSUNG GT-S5369 (mobile phone) Serial number: IMEI Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH FRANCE

Insight on mobile phones and communication system:

Numerical Computation of the Combined Specific Absorption Rates Induced in Human Head due to Multiple Independent Sources

Advanced Measurements of Microwave Oven Leakage

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

National Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

Federal Communications Commission Office of Engineering and Technology Laboratory Division Public Draft Review

Numerical Modelling of E-M Occupational Exposures associated with MRI

National Laboratory of Antennas and Microwave Technology Xidian University Xi an, Shaanxi , China

Federal Communications Commission Office of Engineering and Technology Laboratory Division

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

by Hiroyuki Tamaoka *, Hiroki Hamada * and Takahiro Ueno * 1. INTRODUCTION 2. DEVELOPMENTAL TASKS

Determination of Safe Distance Limit from Cellular base Station Radiation Exposure using SAR Analysis

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

Effect of GSM Phone Radiation on Human Pulse Rate (Heartbeat Rate)

Non-Ionizing Electromagnetic Radiation

RF safety at base station sites

CALCULATION OF WHOLE-BODY SAR FROM A 100 MHz DIPOLE ANTENNA

Harmful effects of 41 and 202 MHz radiations on some body parts and tissues

MRET-Shield Synopsis of Scientific Research Updated on June 1, 2007

Attenuation Measurements of Materials Used in Construction of Buildings

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes

Authors: Michael Hamid. Jose de Jesus Rodriguez. Nicole TrahanSuggested Courses:

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1

RWANDA UTILITIES REGULATORY AGENCY P.O BOX 7289 KIGALI,

A Novel Multi Frequency Rectangular Microstrip Antenna with Dual T Shaped Slots for UWB Applications

TCB RF Exposure Training

Electromagnetic Safety in Wireless Communications and Bio-Medical Technologies

Radio waves and health. Mobile communications

Cell Phone Radiation and Genomic Damage: In Vitro Exposure and Assessment

Measurement of Output Power Density from Mobile Phone as a Function of Input Sound Frequency

Bandwidth Enhancement of Small-Size Planar Tablet Computer Antenna Using a Parallel-Resonant Spiral Slit

Amplification of the Radiation from Two Collocated Cellular System Antennas by the Ground Wave of an AM Broadcast Station

Clean, Green and Safe Management System

RADIOFREQUENCY RADIATION, (RFR): (RFR Information - Technology Newsletter, Full Version)

5-3 Development of Exposure Systems and Exposure Assessment for Studies on Biological Effect of Electromagnetic Fields

RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES

Transcription:

, June 30 - July 2, 2010, London, U.K. Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone Adel Z. El Dein Alaeddin Amr Abstract - This paper analyzes the specific absorption rate (SAR) induced in human head model of various sizes by a mobile phone at 900 and 1800 MHz. Specifically the study is considering in SAR between adults and children. Moreover, these differences are assessed for compliance with international safety guidelines. Also the effects of these head models on the most important terms for a mobile terminal antenna designer, namely: radiation efficiency, total efficiency and directivity, are investigated. Index Terms Human Head, Mobile Phone, SAR. I. INTRODUCTION In recent years, much attention has been paid to health implication of electromagnetic (EM) waves, especially human head part, which is exposed to the EM fields radiated from handsets. With the recent explosive increase of the use of mobile communication handsets, especially the number of children using a mobile phone, that develops many questions about the nature and degree of absorption of EM waves by this category of public as a function of their age and their morphology. For this reason the World Health Organization (WHO) has recommended to undertake research studies on this subject [1]. This paper investigates the effects of head models of various sizes on the most important terms for a mobile terminal antenna designer, namely: radiation efficiency, total efficiency and directivity; and also on the Specific Absorption Rates (SAR) which are induced in them. For this purpose, a comparison is performed concerning those parameters between an adult human head and some children heads obtained as a percent of an adult human head. The results are obtained using an electromagnetic field solver employing the Integral Equations method [2]. The SAR is the most appropriate metric for determining EM effect exposure in the very near field of a Radio Frequency (RF) source [3-7]. The local SAR (W/kg) at any point in the human head is defined as: 2 E SAR 2 where E is the peak amplitude of the electrical field in the human head tissue (V/m), σ is the tissue conductivity (S/m) and ρ is the tissue density (kg/m 3 ). The SAR over a mass of 10g and 1g in the head and the other parameters of the mobile antenna are determined in each case. II. MODELING OF HUMAN HEAD For this study, five head models are used namely: that of an adult and other children human heads of sizes; 95%, 90%, 85%, and 80% of the adult head size (which of size 100%), as they are shown in fig. (1). Each head model consists of shell of skin tissue which is filled with a liquid of brain properties. For simulation of the EM fields in the human head, the appropriate parameters for the conductivity σ (S/m), the relative permittivity r and the tissue density ρ (kg/m 3 ) of all different materials used for the calculation must be known. Additionally, the frequency dependence of these parameters must be considered and chosen appropriately. A recent compilation of Gabriel et al. covers a wide range of different body tissues and offers equations to determine the appropriate dielectric values at each desired frequency [8]. (1) Fig. 1 The description of the various sizes human head models Manuscript received February 24, 2010. Paper no. ICWN_14. Adel Z. El Dein is with the Department of Electrical Engineering, High Institute of Energy, South Valley University, Aswan 81258, Egypt (e-mail:azeinm2001@hotmail.com). Alaeddin Amr is with faculty of Computer Engineering and IT Al-Hussein Bin Talal University P.O. Box 20 Ma'an Jordan (e-mail:amroru@ hotmail.com). Table I shows the real part of the dielectric permittivity ε r, conductivity σ (S/m), and mass density ρ (kg/m 3 ) of tissues used in the simulations at 900 and 1800MHz. Table II

, June 30 - July 2, 2010, London, U.K. shows the volume and the mass of the tissue of all children heads. Table I THE DIELECTRIC PERMITTIVITY ε r, CONDUCTIVITY σ (S/m), AND MASS DEN- SITY ρ (kg/m 3 ) OF TISSUES USED IN THE SIMULATIONS AT 900 AND 1800MHZ. Properties of Tissues Dielectric Permittivity ε r Conductivity σ (S/m) Mass Density ρ(kg/m 3 ) Shell 900MHz 43.8 0.86 1000 (Skin) 1800MHz 38.87 1.19 1000 Liquid 900MHz 45.8 0.77 1030 (Brain) 1800MHz 43.5 1.15 1030 Table II VOLUME AND MASS OF THE HEADS MODELS The Volume and mass of the human Head Human Head Size as a percent from an adult one. Tissue Volume 5.5893 4.7886 4.0706 3.4283 2.8573 (mm 3 )*10 6 Tissue Mass (kg) 5.7439 4.9236 4.1855 3.5250 2.9379 Fig. 3 The return loss without human head III. MODELING OF THE MOBILE PHONE The mobile handset consists of a quarter-wavelength monopole (of radius 0.0025m at 900MHz and 0.001m at 1800MHz) mounted on a mobile handset (treated as a metal box of 1.8cm 4cm 10cm), operates at 900 and 1800MHz and radiated power of 0.125 watt, as it is shown in fig. 2. Fig. 4 The Far Field without human head Fig. 2 The description of the mobile handset IV. RESULTS AND DISCUSSION Figures (3) and (4) present mobile terminal antenna designer parameters namely: return loss, radiation efficiency, total efficiency and directivity, the results obtained with the absence of the human head and at a frequency 1800MHz. Table III present the Mobile Antenna Parameters, namely: radiation efficiency, total efficiency and directivity, the results obtained for various sizes of human heads and for the case of there absence. It is seen that as the size of human head decreases the radiation efficiency and total efficiency decrease, in the other side the directivity increases. The differences between the results of SAR of different kinds are given in Table IV, for each frequency and for each studied child head model. Table III MOBILE ANTENNA PARAMETERS WITH VARIOUS SIZES OF HUMAN HEAD Mobile Antenna Parameters 900 MHz 1800 MHz Without human Head Human Head Size as a percent from an adult one. Rad. 1.003 0.276 0.292 0.311 0.335 0.357 Tot. 0.788 0.271 0.286 0.305 0.328 0.35 Dir. (dbi) 2.627 6.066 5.943 5.859 5.819 5.712 Rad. 1.003 0.485 0.498 0.512 0.528 0.546 Tot. 1.002 0.476 0.489 0.504 0.521 0.539 Dir. 3.653 7.98 7.855 7.756 7.673 7.552 (dbi) The "SAR 10 grams" is the maximum SAR value averaged on 10g which is obtained by averaging the SAR around each point in the volume and adding the nearest points till an average mass of 10g is reached with a resulting volume having the shape of a portion of sphere. The "contiguous SAR 1 gram" is estimated by averaging the local maximum SAR, adding the highest SAR volume in a given tissue till a mass of 1g is reached. The SAR (point) is the local value of SAR at every point inside the head model. The results show that by decreasing the head size the peak SAR 1g and peak SAR 10g decrease, however the percentage of absorbed power in the human head increases. So, the local SAR (point) and total SAR in children s heads increase as children s

, June 30 - July 2, 2010, London, U.K. heads decrease, as indicated in Table III. Also from Table III it is noticed that, the total SAR over the whole human head at 1800MHz is less than that at 900MHz. This is because the SAR regions produced by monopole antenna at 900 MHz are more extended as compared to those induced at 1800 MHz. The human body works as a barrier, mainly in high frequencies, because of skin depth. As the frequency increases the penetration capacity decreases and become more susceptible to obstacles. Figures (5-10) show the distributions of the local SAR, at the y=0 plane; 10 grams SAR in xz plane; and 1gram SAR in xy plane; in (W/kg), on the human head of various sizes, obtained with a radiated power of 125mW from a monopole antenna operates at 900 and 1800MHz respectively. It can be easily noticed that high SAR regions produced by 900MHz monopole antenna are more extended as compared to those induced by 1800 MHz monopole antenna, as it is explained before. Calculated Parameters of the human Head Table IV SAR INDUCED IN CHILDREN S HEADS Human Head Size as a percent from an adult one. 900MHz SAR (point) 1.134 1.206 1.124 1.122 1.214 SAR 1g 0.818 0.805 0.785 0.769 0.769 SAR 10g 0.593 0.59 0.584 0.58 0.572 Absorbed Power 0.089 0.087 0.085 0.082 0.079 (w rms ) Total SAR (W/kg) 0.016 0.018 0.02 0.023 0.027 1800MHz SAR (point) 4.149 3.078 2.404 2.319 2.282 SAR 1g 1.590 1.530 1.482 1.399 1.312 SAR 10g 0.922 0.887 0.848 0.805 0.764 Absorbed Power 0.064 0.062 0.060 0.058 0.056 (w rms ) Total SAR (W/kg) 0.011 0.012 0.014 0.016 0.019 Fig. 5 The distributions of the local SAR at x=0 plane for 1800MHz Fig. 6 The distributions of the (10g) SAR at xz plane for 1800MHz

, June 30 - July 2, 2010, London, U.K. Fig. 7. The distributions of the (1g) SAR at xy plane for 1800MHz Fig. 8 The distributions of the local SAR at x=0 plane for 900MHz Fig. 9 The distributions of the (10g) SAR at xz plane for 900MHz

, June 30 - July 2, 2010, London, U.K. Fig. 10 The distributions of the (1g) SAR at xy plane for 900MHz V. CONCLUSION The obtained results show that the spatial-peak SAR values at a point or as averaged over 1 gram and 10 grams on the human head of various sizes, obtained with a radiated power of 125mW from a monopole antenna operates at 900 and 1800MHz, vary with the size of the human s head at each frequency. Also the sizes of the head have an effect on the mobile terminal antenna designer parameters, and this effect can't be eliminated, because it is an electromagnetic characteristic. The obtained results show that the spatialpeak SAR values as averaged over 1 gram on the human head obtained with a radiated power of 0.125 watt for all simulations are well below the limit of 1.6 W/kg, which is recommended by FCC and ICNIRP [9-11]. REFERENCES [1] R Kitchen, RF and Microwave Radiation Safety Handbook Second Edition, Book, Chapter 3, pp.47-85, 2001. [2] http://www.cst.com/ [3] K. Kiminami, T. Iyama, T. Onishi and S. Uebayashi Novel Specific Absorption Rate (SAR) Estimation Method Based on 2-D Scanned Electric Fields IEEE Transactions on Electromagnetic Compatibility, Vol. 50, No. 4, November 2008, pp. 828-836. [4] S. Watanabe, M. Taki, T. Nojima and O. Fujiwara Characteristics of the SAR Distributions in a Head Exposed to Electromagnetic Fields Radiated by a Hand-Held Portable Radio IEEE Transactions on Microwave Theory and Techniques, Vol. 44. No. 10, October 1996, pp. 1874-1883 [5] A. Hadjem, D. Lautru, C. Dale, M. F. Wong, V. Fouad-Hanna, J. Wiart, "Comparison of Specific Absorption Rate (SAR) Induced in Child-Sized and Adult Heads Using a Dual Band Mobile Phone" proceeding on IEEE MTT-S Int. Microwave Symp. Dig. June. 2004. [6] O. Kivekäs, J. Ollikainen, T. Lehtiniemi, and P. Vainikainen Bandwidth, SAR, and Efficiency of Internal Mobile Phone Antennas IEEE Transactions on Electromagnetic Compatibility, Vol. 46, No. 1, February 2004, pp. 71-86 [7] Brian B. Beard and all Comparisons of Computed Mobile Phone Induced SAR in the SAM Phantom to That in Anatomically Correct Models of the Human Head IEEE Transactions on Electromagnetic Compatibility, Vol. 48, No. 2, May 2006 pp. 397-407 [8] C. Gabriel (1996). Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies "Brooks Air" Force Technical Report AL/OE-TR-1996-0037 [Online]. Available: http://www.fcc.gov/cgi-bin/dielec.sh [9] FCC, OET Bulletin 65, Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields, Edition 97-01, released December, 1997. [10] IEEE C95.1-1991, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 khz to 300 GHz (Institute of Electrical and Electronics Engineers, Inc., New York, 1992). [11] European Committee for Electrotechnical Standardization (CENE- LEC) Prestandard ENV 501 66-2, Human exposure to electromagnetic fields. High frequency (10 khz to 300 GHz) (January 1995).