Technology Installation Review



Similar documents
Heating & Cooling Efficiency

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

How Ground/Water Source Heat Pumps Work

GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - John W. Lund Geo-Heat Center

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Air-Conditioning Buying Guide

AE-1483 Ground-source Heat Pumps. Carl Pedersen Energy Educator

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

Energy Efficiency. Energy Efficient Home Cooling:

How To Use A Water Source Heat Pump

Characteristics of Evaporators

How a Ground Source Heat Pump Works for a School or College

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

HVAC Systems: Overview

Creating Efficient HVAC Systems

Massachusetts COOL SMART. RESIDENTIAL CENTRAL AC/DUCTED AIR SOURCE HEAT PUMP Rebate Application

Glossary of Heating, Ventilation and Air Conditioning Terms

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Comparing Fuel Costs of Heating and Cooling Systems

The efficient heat pump

Basic Design Considerations for Geothermal Heat Pump Systems

Geothermal Energy. How it Works

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Heating, Ventilation & Air Conditioning Equipment

GEOTHERMAL HEAT PUMP SYSTEMS ARE RED HOT BUT ARE THEY REALLY GREEN?

air conditioners how to choose a cooling system

Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014

WaterFurnace Explains GEOTHERMAL HEATING & COOLING

Strategy Guideline: HVAC Equipment Sizing

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

How To Buy A Lennox Power System

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Measured Energy and Peak Demand Reduction from High Efficiency Air Conditioner Replacement

Guide to Minimizing Compressor-based Cooling in Data Centers

Ground-Source Variable Refrigerant Flow Heat Pumps:

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Geothermal Heat Pump Systems

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Evaporative Cooling for Residential and Light-Commercial

Renewable Heat Pumps. A guide for the technically minded

Heat Pumps for Cold Climates?? Yes, Indeed!

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Residential HVAC System Sizing

3/29/2012 INTRODUCTION HVAC BASICS

Selecting a New Water Heater

Energy Efficiency Technologies Air Source Heat Pump vs. Ground Source Heat Pump

Heating Load HERS: Calcs Duct Seal and Test (h), (m)1-3 & 11

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps

Get the FACTS about SEER and Deliver Better Customer Value

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Heating, Ventilation & Air Conditioning Equipment

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Nordic Heat Pump Product Guide

Geothermal Comfort Systems

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

Lower Energy Costs with Rooftop Air-Conditioning Package Units

DAikin Altherma low temperature heat pump. end user leaflet

Vectren Energy Delivery of Indiana Residential Rebate Program Application

Heat Recovery In Retail Refrigeration

Energy Efficient Homes: Air Conditioning 1

Poor Performing AC? High Electric Bills? High Humidity?

RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption

How To Design A Refrigeration System

USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

How to choose a heat pump and use it wisely

Daikin Altherma hybrid heat pump. The natural combination

Refrigeration Basics 101. By: Eric Nelson

Climate Action Plan and Ground Source Heat Pump GHG

J O U R N A L. Energy Performance for. Proper Specification of Air Terminal Units Future Climate Impacts on Building Design

The XP17 provides comfort without comparison.

123 street Salt Lake City, Utah 84092

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

HVAC Efficiency Definitions

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

HVAC Basic Science - System Capacity

2015 C&I HVAC RETROFIT APPLICATION FOR PRESCRIPTIVE REBATES

The Mean Green Cooling MachineTM

Building Energy Systems. - HVAC: Heating, Distribution -

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Transcription:

DOE/EE-0220 Energy Savings from Dual-Source Heat Pump Technology Dual-source heat pump technology provides added degree of energy efficiency The purpose of this Technology Installation Review is to provide an overview of an assessment of an energy-efficient dual-source heat pump. The dual-source technology is a hybrid system that includes the use of both air and geothermal sources for the condensing process in the cooling mode and the evaporating process in the heating mode. The dual-source technology enjoys more favorable economics than a traditional ground-source heat pump, as the ground loop requirements are significantly smaller, reducing the initial cost of the system. Included in this review is a discussion of the results of a field demonstration of a 3-ton system at Fort Stewart, Georgia, (a) and a commercial retrofit demonstration for the U.S. Post Office in Valrico, Florida. (1) Technology Description A heat pump is a device that uses a refrigerant cycle to take low-quality heat (low temperature), compresses it to a higher quality heat (high temperature) and moves that heat to another location in the cycle. It does so with the addition of Dual-source heat pump energy, usually in the form of electricity. This refrigerant cycle is similar to the cooling process employed by a standard household refrigerator. In the heating mode, the heat pump removes heat from a relatively low temperature source, such as the ground or air, and delivers that heat to warm the interior of a building. In the cooling mode, heat is removed from the relatively warm building interior and rejected outside the building, either to the air or the ground (referred to as the heat sink). In the dual-source heat pump, the outside heat source/sink is both the ground and the air, in contrast to a conventional heat pump that uses either the ground (ground-source heat pump) or the air (air-source heat pump). Currently the dual-source heat pump (DSHP) technology is available from a single manufacturer Global Energy & Environmental Research, Inc. (GEER), Lutz Florida. GEER manufactures a line of residential units and retrofit packages for larger commercial-sized systems. Residential sizes range from 2 1 /2 -ton to 5-ton nominal cooling capacities with a 20+ SEER under rated conditions. GEER also makes the dual-source technology available as a retrofit package for commercial HVAC systems in the 5- to 30-ton range. In the retrofit application, the existing compressor(s) are replaced with downsized high-efficiency compressor(s) and the dual-source geothermal technology. The compressors can be downsized because the dual-source technology makes up the difference in capacity. The DSHP systems can also be designed with a dual compressor to provide additional heating capacity at colder temperatures. Technology Installation Review A case study on energy-efficient technologies Prepared by the New Technology Demonstration Program No portion of this publication may be altered in any form without prior written consent from the U.S. Department of Energy and the authoring national laboratory. (a) D.L. Hadley, March 2000. Energy Savings Potential of a Dual-Source Heat Pump System at FORSCOM Installations. PNNL-Letter Report, Pacific Northwest National Laboratory, Richland, Washington. Internet: http://www.eren.doe.gov/femp

Principles of Operation Dual source refers to the use of both air and geothermal sources for the condensing process. In the cooling mode, the liquid refrigerant discharging from an air-source condenser is subcooled by using a ground-sourcecooled fluid. This fluid is then reused after the subcooler to desuperheat, or remove some of the superheat from the hot gas before it goes into the airsource condenser. See Figure 1 for Evaporator Coil Ground Level Expansion Valve a simplified block diagram of the DSHP system. This process can increase net refrigeration capacities by 1% or more per degree of subcooling, depending on the refrigerant, evaporator temperature, evaporator surface area, and other factors. Desuperheating with a secondary fluid, or by direct geothermal contact, results in much more rapid desuperheating of the Heat Exchanger Condensing Coil Heat Exchanger Pump Ground Loop Figure 1. Simplified block diagram of the dual-source heat pump (cooling mode shown). hot gas refrigerant than does airsource desuperheating. This rapid desuperheating results in much lower back head pressure to the compressor, and therefore results in much lower power consumption, a cooler-running compressor, and higher refrigerant mass flow. Ground Loop Requirements One advantage of the dual-source technology is that the size of the ground loop is significantly reduced compared to a conventional groundsource heat pump. The buried piping in a typical ground-source heat pump installation is generally in the range of 150 to 250 feet of vertical ground loop per ton of system capacity. For the dual-source technology, the ground loop consists of 20 to 60 feet of vertical loop per ton of cooling capacity. The loops can be installed in series or installed in parallel through a manifold to direct an evenly distributed flow through all loops. When feasible and available, an acceptable alternative is to install the loop in a pond, lake or river. In both installations, the actual length of the ground-coupled heat exchanger (ground loop) is a function of local climate, soil properties and building characteristics. Length requirements are almost always governed by the cooling mode heat rejection requirements. Rated Performance There are currently no standard rating procedures for dual-source heat pumps comparable to the American Refrigeration Institute (ARI) procedures for air-source pumps and groundcoupled heat pumps. However, the DSHP models available from GEER have been thoroughly performance tested under controlled conditions by an independent laboratory. a The (a) Gene Cornett, personal correspondence (August, 11, 1997), Global Environmental and Engineering Research. 2

cooling EER values are based on an 80 F drybulb and 67 F wetbulb entering air conditions. The heating COPs are based on a 70 F drybulb entering air temperature. The results of these tests for a nominal 3-ton, single compressor model are shown in Figure 2. EER COP 25 20 15 Maintenance/Service Requirements Annual maintenance requirements for the DSHP technology are similar to those of comparably sized airsource heat pumps. Standard preventive maintenance includes periodic filter replacement and coil cleaning. DSHP Performance Cooling 10 20 30 40 50 60 70 80 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 Entering Water Temperature (F) 82F Outside Air Temperature 95F Outside Air Temperature DSHP Performance Heating 1.0 20 30 40 50 60 70 80 Entering Water Temperature (F) 17F Outside Air Temperature 47F Outside Air Temperature Figure 2. Rated performance for a nominal 3-ton capacity, single compressor DSHP as a function of entering water temperature, for the system operating in the cooling mode (top figure) and the heating mode (bottom figure). Federal Sector Application As part of a U.S. Army Forces Command (FORSCOM) field demonstration and evaluation of the DSHP technology, a Facility Energy Decision System (FEDS) (2) screening analysis of alternative HVAC technologies at FORSCOM installations was completed by the Pacific Northwest National Laboratory (PNNL). FEDS is an energy analysis software tool designed to provide a comprehensive approach to fuel-neutral, technology-independent, integrated (energy) resource planning and acquisition. The basic intent of the model is to provide information needed to determine the minimum life-cycle-cost (LCC) configuration of the facility s energy generation and consumption infrastructure. The model has no fuel or technology bias; it simply selects the technologies that will provide an equivalent or superior level of performance at the minimum LCC. The results are ranked by the net present value (NPV) of the LCC. The NPV is the present value of the life-cycle energy, demand, and O&M savings less the present value of capital investments. As used in this application, FEDS was limited to 10 alternative HVAC technologies, including the DSHP. Each technology was modeled as a nominal 3-ton capacity system suitable for residential and small commercial applications. Thus the model was constrained to analyze only individual buildings less than 10,000-square-feet floor area. The alternative technologies, FORSCOM installations, and building sets used in this assessment are shown in Table 1. The FEDS analysis provided a listing of the most cost-effective, alternative technologies selected for each building 3

Table 1. FEDS model screening constraints. HVAC Technology FORSCOM Installation Building Sets Dual-Source Heat Pump Electric Air-Source Heat Pump (Standard Efficiency) Electric Air-Source Heat Pump (Very High Efficiency) Natural Gas Engine-Driven Air-Source Heat Pump Packaged AC Unit with Integral Natural Gas Heat (Standard Efficiency) Packaged AC Unit with Integral Natural Gas Heat (High Efficiency) Dual-Fuel Heat Pump with Integrated Gas Backup Heat (Standard Efficiency) Dual-Fuel Heat Pump with Integrated Gas Backup Heat (High Efficiency) Vertical Closed-Loop Ground-Coupled Heat Pump System (Standard Efficiency/Small) Vertical Closed-Loop Ground-Coupled Heat Pump System (High Efficiency) set and ranked them according to their NPV. The technologies with the greatest NPV were ranked first. For many building sets, the alternative technologies could not meet the LCC criteria, so none were selected. In several cases only a few building sets were identified as suitable targets for the alternative HVAC technologies. At the other sites, the technologies penetrated to varying degrees, depending on the existing building stock, on currently installed HVAC technologies, and on actual energy costs. As expected, the higher the energy cost, the more these alternative technologies become cost-effective. The dual-source heat pump technology appears to be reasonable at some FORSCOM installations, but its application would be appropriate for a limited set of both commercial and residential buildings. Although the initial costs are typically higher for the DSHP than for other technologies evaluated because of the Fort Bragg Fort Campbell Fort Carson Fort Dix Fort Drum Fort Hood Fort Irwin Fort Lewis Fort McPherson Fort Polk Fort Riley Fort Stewart Administration Barracks Electronics Clinic Single- and Multi-Family Housing School/Training ground loop installation (except for the ground-source heat pump), the selection criteria is based on the minimum life-cycle-costs (as required by 10 CFR 436), not just first costs. Under this condition, a DSHP should frequently be the most cost-effective alternative, but not in every circumstance. FORSCOM installation energy managers are encouraged to consider Figure 3. Sign at NCO Academy, Fort Stewart, Georgia. the DSHP technology in future applications, either in new construction or in replacement of existing equipment as part of an energy improvement project. Field Demonstration Summary Training Facility, Fort Stewart, GA. FORSCOM has conducted several technology demonstrations of new, high-efficiency heating and air conditioning for comparison with traditional Federal sector technologies. The intent of this effort is to determine the critical operational aspects of these systems through field evaluation and to assess the cost-effectiveness of the energy savings. Results from this program provide information to energy managers and facility personnel in the Federal sector on the viability of non-traditional heating/cooling systems for energy savings. This section documents a FORSCOMfunded demonstration of a 3-ton Dual Source Dual Compressor Heat Pump (DSHP) at the NCO Academy, Fort Stewart, Georgia. Fort Stewart is located in southeast Georgia, near Savannah. The Sign marking the front gate of the NCO Academy is shown in Figure 3. The building used in the demonstration was a singlestory, 21- by 72- foot wood-frame structure built in the 1940s (see Figure 4). The building is used for classroom training. The interior of the building is partitioned into two classrooms separated by a 4

small mechanical room. During each training rotation, approximately 34 soldiers occupy the building between 8:00 am and 4:30 pm, Monday through Friday. A typical training rotation lasts for 4 weeks, with 1 week between rotations. The existing heating and cooling equipment consisted of a 3-ton direct-expansion air conditioner and a forced-air propane furnace. For the demonstration, the existing heating and cooling equipment was replaced by a split-system, 3-ton PUREARTH dual-source, dualcompressor heat pump (Model DSDCH038D1). This unit has a cooling capacity of 38,200 Btuh and a 17.2 EER. (a) An extensive monitoring system was installed to collect detailed, high-resolution, time-series data to quantify heat pump performance. Key parameters monitored included: heat pump compressor, indoor fan and outdoor fan electrical energy consumption compressor runtime supply and return air temperature Figure 4. General view of the test building at the NCO Academy. return air relative humidity outdoor air temperature, relative humidity and solar radiation ground loop entering and leaving water temperature outdoor heat exchanger entering and exiting air temperature. The DSHP installation was completed in late May 1998 and field monitoring began June 1998. During the first 6 months, the DSHP was plagued with operational problems severely affecting its performance most notable an expansion valve failure and refrigerant system leaks. During this time, the system limped along at sub-optimal performance and minimal useful data was collected to assess normal system performance. The expansion valve was replaced and once the last of the refrigerant leaks were sealed, the system operated without a problem. At the time of the equipment installation, it had been naively assumed that the previous air conditioning equipment was sized correctly for the building cooling loads, so an equivalent-sized 3-ton DSHP was installed. However, only later after occupant complaints of inadequate cooling, was it determined that peak cooling loads under fully occupied conditions were closer to 50,000 Btuh. Anecdotal information from staff at the NCO Academy confirmed that the previous air-conditioning system was also frequently unable to meet the peak cooling loads in the building. As a result of the undersizing, this particular DSHP was insufficient to meet the cooling demand for approximately 700 hours per year. In an attempt to lessen the impact of the undersizing, additional insulation was added to the attic of the test building to reduce the cooling load on the building. During the cooling season test period, the building occupants maintained a thermostat setting of 68 F, without a night setback in an attempt to maintain occupant comfort. As a result, the heat pump ran for an extended time each day (typically 20-24 hours) during the peak cooling season, causing the soil around the ground loop to become heat saturated and not adequately dissipate waste heat as needed for optimal performance. The measured heating performance of the DSHP was based on data collected from January 19,1999, through March 31, 1999. The measured cooling performance of the DSHP was based on data collected from April 1, 1999, through August 8, 1999. A bin-method spreadsheet model was used to estimate the normalized seasonal and annual energy consumption for the dual-source heat pump and an equivalent-sized highefficiency air-source heat pump (ASHP). The estimated heating season energy use for the DSHP would be approximately 15% less than the ASHP (3,400 kwh vs. 4,000 kwh, respectively). The reduction in energy use from the DSHP technology in the cooling season is even greater at 31% (7,100 kwh vs. 10,300 kwh). The annual normalized energy consumption for the DSHP and ASHP would be approximately 10,600 kwh (a) Cooling capacity measured at reference conditions of 95 F outdoor air temperature, 80 dry bulb and 67 F wet bulb entering air temperatures, 70 F entering ground loop water temperatures. 5

and 14,300 kwh, respectively a savings of over 25% for the DSHP. Main Post Office, Valrico, FL. In 1998, the dual-source technology was applied in a retrofit installation in the main post office at Valrico, Florida. The building is a singlestory, 21,000-square-foot structure. The existing HVAC equipment consisted of two standard 15-ton heat pumps and one 10-ton heat pump. The existing compressors in the heat pumps were replaced with downsized high efficiency compressors with Dual Source geothermal technology. The air handler evaporator coils were replaced with Dual Coil technology for improved dehumidification performance. TECO Energy s ESCO engineering firm, Bosek, Gibson and Associates, Inc, completed the system retrofit as part of an energy savings performance contract project. More than eighty 20-foot ground loops were installed for the 40 tons of air conditioning, for a total of 1600 feet of ground-loop heat exchanger. A standard geothermal heat pump would have required over 8000 feet of ground loops to achieve the same amount of subcooling. Daily energy use was reduced by nearly 38% from a pre-retofit 319 kwh to a post-retrofit consumption of 199 kwh. On a typical cooling day, peak demand was reduced by almost 8 kw, from a pre-retrofit peak demand of 18.3 kw. Both the daily energy savings and the peak demand reduction were consistent with the manufacturer s performance claims. Technology Benefits The DSHP technology has been shown to reduce energy consumption compared to conventional technologies. In a field demonstration and assessment of a 3-ton system in a small classroom at Fort Stewart, Georgia, the DSHP reduced cooling energy consumption by 31% and heating energy consumption by 15% compared to a standard air-source heat pump. At the main U.S. Post Office facility in Valrico, three airsource heat pumps were retrofitted with the dual-source technology, reducing daily energy use by nearly 38% and peak demand by 8 kw. The DSHP technology does offer some additional advantages for the residential and small commercial market when compared to conventional air-source heat pumps or geothermal heat pumps. These include: Lower first costs than geothermal heat pumps because of the reduced size of the ground loop. Easier installation in retrofit situations, particularly in the event of an emergency replacement of a failed existing system. The DSHP can be installed and operated initially as an air-source heat pump to meet immediate needs for heating/cooling. The ground loop can be installed at a later date to complete the installation. Improved comfort with less defrost cycling than conventional air-source systems. Reduced peak demand during extreme temperature conditions. References 1. October 1998. Metering and Verification of Savings Report for CU-1, Valrico Main Post Office. Bosek, Gibson and Associates, Inc. Tampa, Florida. 2. Pacific Northwest National Laboratory. 1998. Facility Energy Decision System User s Guide, Release 4.0. PNNL-10542 Rev 2. Richland, Washington. 6

This page left blank intentionally 7

For More Information FEMP Help Desk (800) 363-3732 International callers please use (703) 287-8391 Web site: www.eren.doe.gov/femp General Contacts Ted Collins New Technology Demonstration Program Manager Federal Energy Management Program U.S. Department of Energy 1000 Independence Ave., SW, EE-92 Washington, D.C. 20585 Phone: (202) 586-8017 Fax: (202) 586-3000 theodore.collins@ee.doe.gov Steven A. Parker Pacific Northwest National Laboratory P.O. Box 999, MSIN: K5-08 Richland, WA 99352 Phone: (509) 375-6366 Fax: (509) 375-3614 steven.parker@pnl.gov Technical Contact Donald Hadley Pacific Northwest National Laboratory P.O Box 999 Richland, WA 99352 Phone: (509) 375-3708 Fax: (509) 375-3614 Don.Hadley@pnl.gov Disclaimer This report was sponsored by the United States Department of Energy, Office of Federal Energy Management Programs. Neither the United States Government nor any agency or contractor thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, mark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency or contractor thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency or contractor thereof. Other Contacts Global Energy and Environmental Research, Inc. Gene Cornett 15445 N. Nebraska Ave. Lutz, Florida 33549 Phone: (813)631-8880 geersolutions@worldnet.att.net Fort Stewart Demonstration Fred Cavedo Energy Engineer 3rd Infantry (Mech) and Fort Stewart AFZP-DEE-E, Bldg 1114 Fort Stewart, GA 31314-5000 Phone: (912) 767-5034 cavedof@emh5.stewart.army.mil Printed with a renewable-source ink on paper containing at least 50% wastepaper, including 20% post consumer waste Produced for the U.S. Department of Energy (DOE) by the Pacific Northwest National Laboratory DOE/EE-0220 August 2000