2014 PCD Domain Update. Jeff McGeath Iatric Systems IHE PCD Technical Committee Co-Chair



Similar documents
From Standards to Medical Device Integration An Ongoing Adventure

Current Advances in Medical Device and EMR Interoperability and Integration

IHE Patient Care Device Technical Framework Supplement. Medical Equipment Management Device Management Communication (MEMDMC) Trial Implementation

How To Test Ihe-Pcd

NIST Medical Device Communication Testing

it s about connectivity

Ensuring Patient Safety in Your Connected Hospital

Improving Healthcare IT Systems through Interoperability. IHE can help manage the medical devices mismatch

Interoperability solution for medical devices

Helping the Cause of Medical Device Interoperability Through Standardsbased

You ll love the Vue. Philips IntelliVue Information Center ix

In a previous article on medical device interoperability

Driving healthcare intelligence throughout the continuum of care with standards-based interoperability

EHRDirect Export Reference Guide. Merlin.net Patient Care Network (PCN)

Connect care for early intervention

Integration for your Health Information System

IHE Patient Care Device (PCD) Technical Framework White Paper

Using Your CMMS to Help Manage Network Connected Medical Systems

Interoperability and the Surgery Department

How To Integrate A Wireless Device Into An Isirona

Cerner s Approach to Interoperability:

Connecting Cardiac Device Data and the EHR

80BPM 36.5 C 35/ / 80. Panorama CENTRAL MONITORING SYSTEM. efficient flexible versatile (18) (94) Adult A SMITH, ERICA (92) 5RPM.

Global Health Informatics Standards for Patient Safety

How To Integrate Medical Devices

Designed with you in mind.

Connecting Cardiac Device Data and the EHR

IHE Korea. Daegu 2010 Connectathon eworkshop Todd Cooper, Breakthrough Solutions Foundry, Inc.

Physiologic Monitoring Systems & Connectivity

Barcode Scanning and Infusion Pumps: The Journey to Safety with Wireless Devices

How To Be A Successful Health Care Security Consultant

Networked versatility. IntelliVue MP60 and MP70 patient monitors

Patient Care Device Integration (PCDI) Developing a Strategy for Integrating Medical Device Data with Clinical Information Systems

Integrating the Healthcare Enterprise (IHE) What it is, where we are, and why it is important

High-intensity performance. IntelliVue MP90 patient monitor

MindGent Healthcare Services. Addressing the Issues of Nursing Shortages and Patient Safety through Bio-Medical Device Integration (BMDI)

GE Healthcare. B40 Patient Monitor Connecting intelligence and care.

Guaranteeing your equipment is future-proof

Welcome CareFusion Insider Event HIMSS 2013

When the point of care is on the move

MEDICAL SIMULATION A HOLISTIC APPROACH

Information and Communication Technology in Health Care To Infinity and Beyond. Pam Bush, RN, BScN

IHE Patient Care Devices (PCD) What is REAL vs. what is a DREAM?

HIMSS11 Interoperability Showcase Use Case Tour Descriptions

AHIC / NeHC Use Case. Common methods of Device Connectivity (CmDC)

Automating Anesthesia at Meditech Hospitals: Removing the Risk

PROPOSAL FOR INTEGRATION OF ICU MEDICAL DEVICES WITH ELECTRONIC MEDICAL RECORD

Healthcare. Visibility: when and where you need it

Safer Solutions for Safer Hospitals. Electronic Medical Records One System with Multiple Solutions! Anesthesia EMR. Perfusion ECMO EMR EMR

510(k) SUMMARY. Epic s Blood Product Administration Module version 0.9

Built for peace of mind. IntelliVue MX550 patient monitor

HIMSS Interoperability Showcase 2011

Safety Innovations FOUNDATIONHTSI. Best Practice Recommendations for Infusion Pump-Information Network Integration

Clinical Mapping (CMAP) Draft for Public Comment

Keeping pace with the point of care

ONC Project Drives Results with High- Value, Consumer- Friendly Data. [Font: Verdana Size 30]

EHR Adoption and Vision for HIM

AlertLink. Todd Bechtel

SCHIEx: The South Carolina Health Information Exchange Update

Duke University Health System Electronic Health Record Update. Art Glasgow Chief Information Officer, Duke Medicine

Health Information Exchange. Scalable and Affordable

Medical Device Integration with an Ambulatory Electronic Health Record System

Infinity Central Monitoring and Remote Access Solutions

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

Better Together. Some Things Work. IV Clinical Integration

Eligible Professionals please see the document: MEDITECH Prepares You for Stage 2 of Meaningful Use: Eligible Professionals.

HIMSS Interoperability Showcase 2011

Frequently Heard Epic Terms

ASHP Professional Development Section Advisory Group. Professional Development Opportunities for Informatics Pharmacists

Connex Device Integration Suite (CDIS) Network Connectivity Engine (NCE) software -

ISV Partner Profiles: Healthcare

How To Create An Internet Of Things (Iot) Platform For A Smartwatch And Other Devices

Closing the Loop in IV Medication Administration

Health IT Interoperability: HITSP Overview, Update and Discussion

Customer Service Bulletin

Healthcare Information Exchange Software Testing

Standards and Interoperability: The DNA of the EHR

Introduction to Information and Computer Science: Information Systems

Successfully Implementing Anesthesia into your Perioperative EMR Leah Baron, MD Teresa Gocsik, MS,CRNA,CPHIMS

Integrated Data from Standalone Devices Driving Clinical Success

IHE s Contribution to Telecardiology. Nick Gawrit, heartbase Antje Schroeder, Siemens Healthcare Paul Dow, ACC Charles Parisot, GE

Transcription:

2014 PCD Domain Update Jeff McGeath Iatric Systems IHE PCD Technical Committee Co-Chair

Patient Care Device (PCD) Domain Formed in 2005 to address issues related to integration of Point-of-Care Medical Devices Mission enable Out of the Box, Reliable, Functionally Interoperable solutions Using IHE & PCD open Processes and open Standards Technical Underpinnings HL7 version 2.6 IEEE 11073 Standards 10101 Standardized Nomenclature, 10201 Standardized Information Model Wireless Communication Transfer Protocol (WCTP) IHE ITI domain Consistent Time (CT) profile Network Time Protocol (NTP) IHE PCD Co-sponsors

Patient Care Device (PCD) Domain Focus is on devices associated with patients, including Patient monitors, vital signs monitors, pulse oximetry, ventilators, Infusion pumps, syringe pumps, PCA pumps, etc. Collecting and reporting data from devices for immediate access and for retrospective storage and retrieval (EMR) Device to Enterprise Communication (DEC) (leveraged by Continua Alliance for feeding data into health records) Implantable Device - Cardiac Observation (IDCO) Retrospective Data Query (RDQ)

Patient Care Device (PCD) Domain (contd.) Getting alerts (alarms & advisories) to staff (clinicians, clinical engineers, IT, etc.) on mobile & desktop devices Alert Communication Management (ACM) (formerly Alarm Communication Management) Improving infusion order safety (including a 6 th right, right pump) Point of care Infusion Verification (PIV) Infusion Pump Event Communication/Event Communication (IPEC/EC)

Patient Care Device (PCD) Domain (contd.) Harmonizing terminology Rosetta Terminology Mapping (RTM) RTM Management System in conjunction with NIST Waveform support Waveform Content Module (WCM) communicating evidentiary data for storage and alerting Medical Equipment Management Device Management Communication (MEMDMC) Location Services (MEMLS)

Device to Enterprise Communication (DEC)

Alert Communication Management (ACM) HL7 Messages per ACM and WCM profiles Parameters, waveforms, etc. as evidentiary data items Device Specific graphics Alert Source Alert Reporter AR Report Alert PCD-04 PCD-05 Report Alert Status Alert Manager AM Disseminate Alert PCD-06 PCD-07 Disseminate Alert Status Alert Communicator AC Alert Information Source, Phase, State, Priority Patient Location Instance Alert text Callback Timestamp Evidentiary data Dissemination Status Instance Accepted by AC Undeliverable Delivered Read Accepted Rejected Cancelled Callback start/stop

Point of care Infusion Verification (PIV) Physician s Order Nurse Review Pharmacist Review BCMA to Pump (PCD-03) Pump may provide data to EMR (PCD-01) Medication Administered Medication Nurse confirms 6 Rights: Right Patient Right Medication Right Dose Right Time Right Route Right Device

Infusion Pump Event Communication (IPEC) Infusion Pump Event Communication enables reporting of clinical and operational events from an infusion pump to a Bedside Computer-assisted Medication Administration (BCMA) system or EMR. Clinicians can then view and validate this information for infusion documentation. BCMA/EMR Prior to medication administration, nurse confirms the 6 Rights of administration using BCMA/EMR: Right Patient Right Medication Right Dose Right Time Right Route Right Device Infusion order sent from BCMA/EMR to Pump (PCD-03) Infusion-related events are displayed, validated, and/or recorded by the clinician using the BCMA/EMR Pump provides information on infusion-related events to BCMA/EMR (PCD-10) such as: Delivery Start Delivery Stop Delivery Complete

Implantable Device Cardiac Observation (IDCO)

Retrospective Data Query (RDQ) Supports retrospective query of PCD data from databases. Supports Use Cases such as Clinical Decision Support, backfilling of EMR databases, etc. Data Query PCD-12 Data Query PCD-12 Data Response PCD-13 Data Server and/or Data Requester Full Disclosure Data Response PCD-13 EMR, CDSS, CIS, Etc. Data Query PCD-12 Data Response PCD-13 Data Servers Data Requesters

Waveform Content Module (WCM)

Device Management, Location Services

Device Interoperability CPOE/ Pharmacy System Anesthesia Ventilation and Other Systems Physiologic Monitoring System Clinical Decision Support System ACM, DEC, ECM, WCM ACM, ECM, DEC, WCM ACM, ECM, ADQ, DEC, WCM Barcode Med Admin System P I V Infusion Pump ACM, DEC IPEC EMR/EHR CIS Interface Systems IDCO Implantable Device Phones and Other Devices for Clinicians Current PCD ACM, ECM, WCM Future PCD Home Based Systems Future Non- PCD DEC ACM, ECM, DEC, WCM Other Devices ACM, DMC, ECM CMMS and RTLS Systems ACM Alert Communication Management DEC Device Enterprise Communication DMC Device Management Communication EC Event Communication IPEC Infusion Pump Event Communication IDCO Implantable Device Cardiac Observation PIV Point-of-Care Infusion Verification RDQ Retrospective Data Query WCM Waveform Content Module

NIST Testing Tools HL7 Message Definitions Value Set Constraints IEEE / Rosetta Nomenclature Test Case Specific Assertions Etc.

NIST Testing Tools

Current Efforts Alerts (alarms & advisories) & Events Rosetta Terminology Mapping Device Specializations Pulse Oximeter, Infusion Device, Ventilator Medical Device Security Management PCD Profile Version Management FHIR Resources general FHIR technology review to culminate in a whitepaper describing PCD terminology mapping to FHIR FDA UDI Working with the HL7.org committees to advance UDI support in HL7 v2.

Optimized Message Syntax (OMS) Optimized Message Syntax is an effort to adapt IHE PCD profiles for devices that have slow legacy RS-232 serial ports. OMS will optimize the PCD messages to reduce their size but still maintain consistency with mainstream PCD messages. OMS Messages Bedside Computer EMR, CDSS, CIS, Etc. Data Collection System

Future Efforts Medical Device Technical Management Error logs, access to device logs Software & Hardware revisions Medical Device Cyber Security Medical Device to Device Communication Medical Device Specializations Improving device management, safety, and availability (DMC, RTLS) Utilization, Location, Failure alerts, Battery condition Improved asset management (qty rented/purchased)

Role of Healthcare Organizations Support the Mission of IHE PCD Participate in IHE PCD The voice of the users of what vendors produce be heard Plant the Seed Support and Request IHE Interoperability Encourage active IHE participation by vendors Purchase IHE PCD compliant products Request vendors to provide IHE Integration Statements Specify IHE PCD compliant solutions in RFPs by profile/actor

IHE PCD Compliant Systems COMPANY SYSTEM SYSTEM TYPE PCD PROFILES Accent on Integration, Inc. (AOI) Accelero Connect Medical Device Integration DEC Amcom Messenger Alarm Manager ACM B Braun DoseTrac Infusion Management Software Gateway software DEC, ACM, PIV BIOTRONIK SE & Co. KG Home Monitoring Service Center Implantable Cardiac Device Observer System IDCO Carefusion CGW Gateway DEC Cerner CareAware ibus Device Connectivity Platform DEC Epic EpicCare Inpatient and associated modules EMR/EHR DEC, PIV,IDCO GE HealthCare CARESCAPE Gateway Gateway DEC Hospira Hospira MedNet Infusion pump gateway PIV imdsoft MetaVision Suite CIS, AIMS DEC isirona DeviceConX Medical Device Integration DEC Mindray DS USA, Inc. egateway HL7 Gateway ACM, DEC Mindray DS USA, Inc. A5 Anesthesia machine DEC Nuvon VEGA Gateway DEC OZ Systems esp Interface DEC Philips Emergin IntelliSpace Event Management Alarm Manager ACM Philips Healthcare Philips IntelliVue and Philips IntelliBridge SC200 Monitoring central station and gateway DEC ScottCare ScottCare OneView Sysrtem Implantable Cardiac Device Observer System IDCO St. Jude Medical, Inc. Merlin.net MN5000 Implantable Cardiac Device Observer System IDCO Surgical Information Systems SIS Periop CIS, EHR, AIMS ACM, DEC Welch Allyn Connex VM Vital Signs Monitor DEC

Additional Resources IHE PCD Getting Started Tiny.cc/PCDStart IHE PCD User Guide Tiny.cc/PCDHandbook IHE web site www.ihe.net PCD web site www.ihe.net/pcd/index.cfm IHE ftp site ftp://ftp.ihe.net PCD ftp site ftp://ftp.ihe.net/patient_care_devices/ PCD wiki wiki.ihe.net/index.php?title=patient_care_devices Test Tool web sites PCD Pre-Connectathon tinyurl.com/nist-pcdtt PCD Connectathon tinyurl.com/nist-pcdctt Rosetta Terminology tinyurl.com/nist-rtmms