Quantifying Vitamin E in vegetable oils with reversed-phase high performance liquid chromatography

Similar documents
Vitamin C quantification using reversed-phase ion-pairing HPLC

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Determination of Caffeine in Beverages HPLC-1

Determination of caffeine and vitamin B6 in energy drinks by high-performance liquid chromatography (HPLC)

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

SUCRALOSE. White to off-white, practically odourless crystalline powder

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Colorimetric Determination of Iron in Vitamin Tablets

I. ACID-BASE NEUTRALIZATION, TITRATION

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Chemical analysis service, Turner s Green Technology Group

ERDOSTEINE - MONOGRAPH.

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

ß-CYCLODEXTRIN SYNONYMS

Analytical Test Report

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Analysis of Vegetable Oils by High Performance Liquid Chromatography

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

ETHYL LAUROYL ARGINATE

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

A Complete Solution for Method Linearity in HPLC and UHPLC

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

How To Test For Contamination In Large Volume Water

[ Care and Use Manual ]

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

HPLC WITH UV DETECTION FOR MEASUREMENT OF VITAMIN E IN HUMAN MILK

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

TECHNICAL REPORT STUDY CHEMICAL PROPERTIES OF RATTAN SHOOT FROM PLANTATION IN THAILAND

Gel Filtration Standard

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Pesticide Analysis by Mass Spectrometry

Vitamin C HPLC Kit. For reference use only For research use only. For the determination of Vitamin C in Li-heparine plasma. Manual

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Analysis of Various Vitamins in Multivitamin Tablets

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Measuring Protein Concentration through Absorption Spectrophotometry

ENZYME KINETICS ENZYME-SUBSTRATE PRODUCTS

VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI

Human serum albumin (HSA) nanoparticles stabilized with. intermolecular disulfide bonds. Supporting Information

Drospirenone and Ethinyl Estradiol Tablets. Type of Posting. Revision Bulletin Posting Date. 31 July 2015 Official Date

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

International Journal of Pharma and Bio Sciences V1(2)2010

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

INTERNATIONAL OLIVE COUNCIL

Supplementary Materials and Methods (Metabolomics analysis)

CORESTA RECOMMENDED METHOD N 72

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

PHENOLIC AND ANTIOXIDANT ASSAYS. Gaziosmanpaşa University

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Appendix 5 Overview of requirements in English

Project SMT-CT

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Factors Affecting Enzyme Activity

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

Dissolved and precipitated oxalate

A NEW METHOD DEVELOPMENT AND VALIDATION FOR ANALYSIS OF RIVAROXABAN IN FORMULATION BY RP HPLC

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

INSTRUCTIONS Edition AC

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Carlson Cod Liver Oil contains the important omega-3s, DHA & EPA.

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

Lab 2. Spectrophotometric Measurement of Glucose

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

Determination of the Mass Percentage of Copper in a Penny. Introduction

ORIGINAL SCIENTIFIC PAPER. Gabriella POHN. Éva VARGA-VISI SUMMARY KEY WORDS

CypExpress 3A4 Catalyzed Conversion of Testosterone (TE) to 6β- Hydroxytestosterone (HT)

Analytical Chemistry Lab Reports

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Purification of reaction mixtures using flash chromatography.

Transcription:

Quantifying Vitamin E in vegetable oils with reversed-phase high performance liquid chromatography Brock Goossens and Joe Marion Department of Chemistry, Concordia College, 901 8 th St. S, Moorhead, MN 56562 Abstract Vitamin E is an important antioxidant in the human diet and comes in two primary structures: tocopherols and tocotrienes. Reversed phase high performance liquid chromatography was used to separate and quantify α- and δ-tocopherols in canola and soybean oil. Using the novel methanol extraction and a methanol/water mobile phase method of Gimeno et.al, the tocopherols were resolved with complete baseline separation. Canola oil was determined to contain 19 ± 2.3 ppm α-tocopherol and 22.9 ± 0.65 ppm δ- tocopherol. Soybean oil was determined to contain 16 ± 2.3 ppm α-tocopherol and 147 ± 1.8 ppm δ-tocopherol. Introduction Vitamin E is a fat-soluble molecule that is essential in the human diet. Once absorbed by the blood stream, vitamin E works to prevent oxidative reactions of unsaturated fatty acids and other biomolecules. Protection against oxidation reactions is important to human health because oxidants can form free-radical molecules and become mutagenic to DNA. 1 Vitamin E deficiency is caused by mutations of tocopherol transfer protein, and a low dietary intake of the vitamin. 2 Symptoms of low vitamin E levels include ataxia, anemia caused by the breakdown of red blood cells and peripheral neuropathy. Vitamin E deficiency studies conducted on rats also caused changes in retina color. 1 Tocopherol, Fig. 1, and tocotrienol, Fig. 2, are two forms that vitamin E is found. Each of these forms can be further subdivided into α, β, δ, and γ forms and all have differing antioxidant potency. 3 γ-tocopherol is the primary form of vitamin E found in a normal diet in the United States, but this form is ultimately converted to α-tocopherol once inside the body. 4 Figure 1. α-tocopherol Figure 2. tocotrienol α and δ tocopherol are found in large quantities in vegetable oils. Canola oil contains 0.021% wt or 192 ppm α-tocopherol and 0.394 ppm δ-tocopherol. Soybean oil contains 0.0075% wt or 69 ppm α-tocopherol and 0.0266% wt or 245 ppm δ-tocopherol. 3 These values have been obtained primarily using high performance liquid chromatography (HPLC) in both reverse and normal phase. Normal phase HPLC has the benefit of being able 45

to separate all derivatives of tocopherol whereas reversed phase can only separate α, δ, and a third peak containing γ+β. 5 HPLC has not been shown to be effective at separating tocotrienols. In this experiment, we quantified both α and δ tocopherols in Crisco brand canola and soybean oils following the method of Gimeno et.al. using reversed phase HPLC. Experimental Standards Preparation A stock solution of δ-tocopherol (F.W. 402.65 g/mole) was prepared by placing 60.3 mg of δ-tocopherol in a 25-mL volumetric flask and diluting to the mark with ethanol (5.99 10-3 M). Five standard solutions, concentrations of 5.00, 10.00, 15.00, 20.00, and 25.00 ppm, were prepared by adding 20.7 µl, 41.5 µl, 62.2 µl, 82.9 µl, and 103.6 µl, respectively, of stock solution to 10 ml volumetric flasks and diluting to the mark with ethanol. A stock solution of α-tocopherol (F.W. 430.71 g/mole) was prepared by placing 100 mg of α-tocopherol in a 50 ml volumetric flask and diluting to the mark with ethanol (4.64 10-3 M). Five standard solutions with concentrations of 43.07, 86.14, 129.21, 172.28, and 215.36 ppm were made by adding 215.4 µl, 430.8 µl, 646.1 µl, 861 µl, and 1076.9 µl, respectively, to 10-mL volumetric flasks and diluting to the mark with ethanol. The ten standard solutions were then pipetted into ten individually labeled vials (δ1-δ5 and α1-α5). Sample Preparation The samples analyzed were Crisco brand canola oil and soybean oil. Four trials of each oil were prepared for a total of eight trials. Tocopherol was extracted into methanol from the oil using a 1:3 ratio of oil to methanol in a 2-mL microcentrifuge tube. The sample was then vortexed and centrifuged at 3000 rpm for five minutes. A 0.45-µm pore size syringe filter was used to remove the remaining oil and the samples were placed into individually labeled vials C1-C4 and S1-S4. Instrumentation A Varian ProStar HPLC system was used to carry out the separations. This system consists of a piston-based pump, an autosampler, a reversed-phase chromatographic column (Kinetex 50 4.6 mm), and a variable-wavelength UV-vis spectrophotometric detector. The column was housed in a column heater at 35 C, and the mobile phase was a 95:5 ratio of methanol to ultra-pure water (double-deionized water that was vacuum filtered). Analysis was carried out with a mobile phase flow rate of 1 ml/min with detection at 292 nm. Each run had an injection volume of 10 µl and a run time of five minutes. 46

Data Analysis Chromatograms for the eight samples and ten standards were collected. Calibration plots were constructed in which area was plotted versus concentration. Results and Discussion Peak areas from the chromatograms in Fig. 3 were used to make calibration curves seen in Fig 4. The α tocopherol standards displayed a retention time shift as concentration increased. This could be due to changes in pressure of the column and could potentially be eliminated in future trials with the same concentrations. Figure 3. α-tocopherol standard (left) and δ-tocopherol standard (right) Peak Area 12 10 8 6 4 2 0 y = 0.0487x + 0.0905 R² = 0.9991 0 100 200 300 [α-tocopherol] ppm [δ-tocopherol] ppm Figure 4: Calibration curves for α (left) and δ tocopherol (right) generated in Microsoft Excel. Peak Area 1 0.8 0.6 0.4 0.2 0 y = 0.0309x + 0.0143 R² = 0.9918 0 10 20 30 Error in the calibration curves was calculated using the propagation of uncertainty with a calibration curve method of Harris. 6 As can be seen in Fig.5, the left most peak, appearing at approximately 2.7 min, is associated with δ tocopherol. The right most peak, appearing at approximately 3.85 min, is associated with α tocopherol. The large peak between the α and δ peaks is likely the β+γ forms of tocopherol 5 which cannot be separated by reversed phase HPLC. 47

Figure 5. Soybean Oil sample (left) and Canola oil sample (right) Canola oil was observed to contain 19 ± 2.3 ppm α-tocopherol and 22.9 ± 0.65 ppm δ-tocopherol while soybean oil was observed to contain 16 ± 2.3 ppm α-tocopherol and 147 ± 1.8 ppm δ-tocopherol. These values differ by 90.0%, 5700%, 76.8%, and 40.0% respectively from the literature values 3 for tocopherol in vegetable oil. These values were obtained using calibration curves of both α and δ-tocopherols comparing peak area (mau/min) vs. the concentration of the standard. Table 1: Literature and calculated concentrations of α-tocopherol with % Error Sample α-literature value 3 (ppm) α-calculated % Error Canola Oil 192 19.1 90.0 Soybean Oil 69.0 16.0 76.8 Table 2: Literature and calculated concentrations of δ-tocopherol with % Error Sample δ-literature value 3 (ppm) δ-calculated % Error Canola Oil 0.394 22.9 5700 Soybean Oil 245 146.9 40.0 One peculiar observation is the oddly low observed concentration of α-tocopherol in both oil samples. This could be due to several factors ranging from an incomplete extraction of tocopherol to degradation of tocopherol within the oil. Although we were able to reproduce the chromatograms with high precision, a considerable amount of tocopherol may remain in the oil. Many more separately prepared trials will need to be conducted to eliminate this discrepancy. The observed amount of δ-tocopherol in canola is considerably larger than the literature value. The canola oil that was used in this experiment was not virgin oil and contained an added amount of tocopherol that was observed in the δ form. A tocopherol concentration literature value for the canola oil used in this experiment could not be found. With concentrations and absorbencies being rather low, standard additions may be beneficial in determining the concentrations of tocopherols. This would allow quantification of a smaller concentration and minimize matrix effects of the instrument. 48

Several major adjustments were made to the method of Gimeno et. al. The first was the dilution factor of the oil samples. After several trials, we determined that diluting the samples did not increase peak separation as stated in Gilmeno et.al. Rather, we prepared our samples by a single extraction of oil to methanol 1:3 v/v. The second adjustment that was made was the temperature of the column. Rather than the 45 C of Gimeno et.al., 35 C was used and better peak separation was observed. The final and most important changes were made to the instrument itself. A different column was used as well as a different injection volume. Both of these changes produced identifiable, separated, and symmetric peaks. A number of factors contributed to the error in the experiment. First of all, the tocopherol that was ordered came as a highly viscous liquid. Despite being approximately 100 mg each (noted by Supelco ), a problem was presented in weighing and transferring the tocopherols accurately. For the α-tocopherol, an exact weight was not determined; it was assumed to be 100 mg. After a failed attempt at mixing a δ-tocopherol stock solution, a more accurate weight was determined by weighing the container before and after transferring. Error could have also arisen due to improper storage of the tocopherols. The packaging suggested storing at 20 C, but they were kept at room temperature. This could possibly explain the large peak near the solvent front and could be a result of degradation. Another source of error may have come from a lack of extractions when preparing the sample solutions. Additional extractions would increase the concentration of tocopherol in the sample and may possibly produce larger peaks. Conclusions Reversed phase HPLC, under the proper conditions, is an effective tool to separate and quantify tocopherol species within vegetable oils. The method of Gimeno et. al. was a useful starting point for this experiment but was not completely reproducible in our laboratory. Canola oil was determined to contain 19 ± 2.3 ppm α-tocopherol and 22.9 ± 0.65 ppm δ-tocopherol. Soybean oil was determined to contain 16 ± 2.3 ppm α-tocopherol and 147 ± 1.8 ppm δ-tocopherol. Acknowledgments Special thanks to Dr. Mark Jensen for his involvement in this experiment and for providing us with a most excellent column. References 1. Vitamin E. Encyclopedia Britannica. Online: http://www.britannica.com.cordproxy.mnpals.net/ebchecked/topic/631145/vitamin- E (accessed March/ 24, 2011). 2. Ouahchi, K.; Arita, M.; Kayden, H.; Hentati, F.; Ben Hamida, M.; Sokol, R.; Arai, H.; Inoue, K.; Mandel, J. L.; Koenig, M. Ataxia with isolated vitamin E deficiency is caused by mutations in the alpha-tocopherol transfer protein. Nat. Genet. 1995, 9, 141-145. 3. Anonymous In vitamin E; Benders' Dictionary of Nutrition and Food Technology; Woodhead Publishing Ltd: Cambridge, United Kingdom, 2006. 49

4. Jiang, Q.; Christen, S.; Shigenaga, M. K.; Ames, B. N. gamma-tocopherol, the major form of vitamin E in the US diet, deserves more attention. Am. J. Clin. Nutr. 2001, 74, 714-722. 5. Packer, L.; Fuchs, J. In Vitamin E in health and disease; Dekker: New York, 1993;, pp 1000. 6. Harris, D. C. In Quantitative chemical analysis; W.H. Freeman and Co.: New York, NY, 2007. 50