ABB Drives. User s Manual TTL Pulse Encoder Interface Module RTAC-03

Similar documents
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Modular I/O System Analog and Digital Interface Modules

X8 Option 2 - Technology

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

SV 210 Signal Splitter and Incremental Converter for Sine-Cosine Encoders

Digital input modules

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

Three Channel Optical Incremental Encoder Modules Technical Data

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Description. Dimensions. Features. precision works better

DMX2PWM 9 Channel Dimmer Setup Manual

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

PCS0100en Persy Control Services B.V. Netherlands

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

ABB Drives. Protocol Manual - Modbus/TCP Ethernet Adapter Module FENA-01

Rack mounted telephone- and leased line modem for industrial applications

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

TX OPEN RS232/485 module

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

ZC-24DO CANopen I/O Module: 24 Digital Outputs

SYSTEM 4C. C R H Electronics Design

How To Power A Schen

Install the DeviceNet Module using the following procedure:

MINI MCR-SL-R-UI(-SP)

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Original instructions Tina 3A/Aps Adaptor unit

Allen-Bradley/Rockwell

Disturbance Recoder SPCR 8C27. Product Guide

Installation and Start-up Guide. CS 31 Adapter Module NCSA-01

Tina 2A/B Adaptor unit

SYSTEM 45. C R H Electronics Design

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

ENCODER TEST MODULE APPLICATION GUIDE

ABB general machinery drives. User s manual ACS355 drives

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Duct Humidity Transmitter

L5354 ControlNet Communications Interface

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

QR12 (1.22 ) Diameter Optical Encoder

Safety Relays ESM/ESM-F

Product and functional description

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Safety Manual BT50(T) Safety relay / Expansion relay

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Addendum to the Operating Instructions

NC-12 Modbus Application

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

EXTERNAL DIMENSIONS AND PARTS

Waveguide Access Point WGA631. Product Guide

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Smile 11 AS-i Emergency stop with safe AS-i input node

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

HARTING econ 3000 Introduction and features

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Achat 115MA full-range speaker. user manual

Combi switchbox with integrated 3/2 way pilot valve

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Provides one channel for Ethernet over existing

Contents. Document information

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Analog Servo Drive 25A8

HEDS-9000/9100 Two Channel Optical Incremental Encoder Modules. Features. Applications

Small Optical Encoder Modules 480lpi Digital Output. Features. Applications VCC 3 CHANNEL A 2 CHANNEL B 4 GND 1

Voltage Regulator SPAU 341 C. Product Guide

IO-DIM6 6-Channel, Digital to Analogue Converters

INSTALLATION INSTRUCTIONS

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

ACS 800. Supplement Traverse Control Application Program 7.x

I STAR COMPUTER CO., LTD

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

M2M/IoT Solutions.

KNX R. Rain Sensor. Installation and Adjustment

Drayton Digistat +2RF/+3RF

TECHNICAL DATASHEET Incremental Encoder RI 80-E

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Telephone- and leased line modem for industrial applications TD-36

PUSH BUTTON START INSTALLATION MANUAL

Absolute Rotary Encoder E6CP

POINTS POSITION INDICATOR PPI4

Transcription:

ABB Drives User s Manual TTL Pulse Encoder Interface Module RTAC-03

TTL Pulse Encoder Interface Module RTAC-03 User s Manual 3AFE68650500 REV A EN EFFECTIVE: 10.02.2006 2006 ABB Oy. All Rights Reserved.

5 Safety instructions Overview This chapter states the general safety instructions that must be followed when installing and operating the RTAC-03 TTL Incremental Encoder Interface module. The material in this chapter must be studied before attempting any work on, or with, the unit. In addition to the safety instructions given below, read the complete safety instructions of the specific drive you are working on. General safety instructions WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians. The drive and adjoining equipment must be properly earthed. Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. The motor cable terminals of the drive are at a dangerously high voltage when mains power is applied, regardless of motor operation. There can be dangerous voltages inside the drive from external control circuits even when the drive mains power is shut off. Exercise appropriate care when working on the unit. Neglecting these instructions can cause physical injury or death. Safety instructions

6 Safety instructions

7 Table of contents Safety instructions............................................ 5 Overview.................................................... 5 General safety instructions....................................... 5 Table of contents............................................. 7 Introduction................................................. 9 Intended audience............................................. 9 Before you start............................................... 9 What this manual contains....................................... 9 Overview................................................... 11 Overview................................................... 11 The RTAC-03 module......................................... 11 Module layout.............................................. 11 Delivery check............................................... 12 Compatibility................................................. 12 Installation................................................. 13 General.................................................... 13 Chaining.................................................... 14 Setting the termination DIP switch (S2).......................... 15 Removing the cover of the enclosure.......................... 15 Locating the termination DIP switch........................... 15 Termination DIP switch settings.............................. 16 Mounting the RTAC-03 onto the RMIO board....................... 17 Mounting the RTAC-03 onto an AIMA-01 I/O Module Adapter.......... 18 Setting the node ID.......................................... 18 Mounting.................................................. 18 Table of contents

8 Wiring...................................................... 19 Terminal designations........................................ 19 Cable recommendation....................................... 20 Phasing................................................... 20 Wiring diagram............................................. 21 Position latching.............................................. 22 Programming the RTAC-03..................................... 22 Fault tracing................................................ 23 Diagnostic LEDs.............................................. 23 CHA, CHB (Green).......................................... 23 WD/INIT (Yellow)............................................ 23 Installation problems........................................... 23 Option slot installation........................................ 23 AIMA-01 I/O Module Adapter installation......................... 24 Technical data............................................... 25 RTAC-03 data................................................ 25 Table of contents

9 Introduction Intended audience Before you start The manual is intended for the people who are responsible for commissioning and using an RTAC-03 TTL Pulse Encoder Interface module with the ACS800 drive. The reader is expected to have a basic knowledge of electrical fundamentals, electrical wiring practices and how to operate the drive. It is assumed that the drive is installed and ready to operate before starting the installation of the extension module. In addition to conventional installation tools, have the drive manuals available during the installation as they contain important information not included in this manual. The drive manuals are referred to at various points of this document. What this manual contains This manual contains information on the wiring, configuration and use of the RTAC-03 module. Safety instructions are featured in the first few pages of this manual. Overview contains a short description of the RTAC-03 TTL Encoder Interface module and a delivery checklist. Installation contains instructions for module hardware settings, mounting and cabling. Fault tracing explains fault tracing and the LED indications of the RTAC-03 module. Technical data contains information on the physical dimensions, configurable settings, and connectors of the module. Introduction

10 Introduction

1 0 7 8 11 Overview Overview This chapter contains a short description of the RTAC-03 Pulse Encoder Interface module and a delivery checklist. The RTAC-03 module The RTAC-03 module offers an interface for a TTL-type incremental pulse encoder connection. A TTL pulse encoder is used to obtain accurate speed or position (angle) feedback from the motor shaft. Module layout Node ID selector (S1) 2 3 4 5 6 Fixing screw (GND) Diagnostic LEDs RTAC-03 TTL PULSE ENCODER INTERFACE GND CHASSIS SHLD F E D C SHLD B A 9 CHA CHA+ CHB WD/ INIT X3 NODE ID X2 CHA- CHB+ CHB- CHZ+ CHZ- DI+ DI- X1 +24V +5.5V 0V Fixing screw (CHASSIS) 1 2 3 4 5 6 7 8 1 2 1 2 3 Terminal block for encoder signals (X3) Digital input for position latching (X2) Terminal block for encoder power supply (X1) Overview

12 Delivery check Compatibility The option package contains: RTAC-03 module Two screws (M3 8 mm) This manual. The RTAC-03 is compatible with the ACS800 Motion Control Application Program version APXR7100 or later. Overview

13 Installation WARNING! Follow the safety instructions given in this guide and the drive manuals. General The RTAC-03 is to be inserted into the position marked SLOT 1 or SLOT 2 on the drive. The module is held in place with plastic retaining clips and two screws. The screws also provide the earthing of the I/O cable shield connected to the module, and interconnect the GND signals of the module and the RMIO board. On installation of the module, the signal and power connection to the drive is automatically made through a 38-pin connector. The module can alternatively be mounted on a DIN rail-mountable AIMA-01 I/O Module Adapter. Installation

14 Chaining The encoder signals can be chained to several RTAC-03 modules. Whenever the encoder signals are chained to multiple modules, the termination should be switched off on all modules in the chain except the last one. 1 1 2 2 0 0 VCC 0V Notes: For simplicity, grounding of the cable shields is not shown. See the wiring diagram on page 21. The encoder power outputs (X1) of the RTAC-03 modules cannot be connected in parallel. The encoder is to be supplied from one module only (or an external power supply). X3 3 A+ 4 A- 5 B+ 6 B- 7 Z+ 8 Z- X1 1 2 3 +24V +5.5V 0V X3 3 A+ 4 A- 5 B+ 6 B- 7 Z+ 8 Z- X3 3 A+ 4 A- 5 B+ 6 B- 7 Z+ 8 Z- RTAC-03 No. 1 Termination OFF RTAC-03 No. 2 Termination OFF RTAC-03 No. 3 Termination ON Because the termination switch is located inside the housing of the module, it is practical to set the switch before the module is mounted and wired. Installation

Setting the termination DIP switch (S2) Removing the cover of the enclosure In order to access the termination DIP switch, the cover of the module enclosure must be removed. This can be done by carefully bending the two cover retaining clips with a small screwdriver and lifting the cover off. Refit the cover by pushing it back into its place until the retaining clips lock it into position. 15 Retaining clips Cover Base Locating the termination DIP switch ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 1 2 3 4 5 6 7 8 1 2 1 2 3 X3 X2 X1 Installation

16 Termination DIP switch settings Termination ON (default) Switch setting ON 1 2 3 4 5 6 OFF ON 1 2 3 4 5 6 Installation

Mounting the RTAC-03 onto the RMIO board 1. Insert the RTAC-03 carefully into SLOT 1 or SLOT 2 on the RMIO board until the retaining clips lock the module into position. 2. Fasten the two screws (included) to the stand-offs. Note: Correct installation of the screws is essential for fulfilling the EMC requirements and for proper operation of the module. 17 Installation

0 8 18 Mounting the RTAC-03 onto an AIMA-01 I/O Module Adapter Before mounting the module onto the AIMA-01, the node ID must be set. Setting the node ID Choose the proper node ID for the module using the selector switch S1. The settings 0 F correspond to node IDs 16 31. The default setting is 0 (node ID 16). For the correct node ID number, see the appropriate Firmware Manual. Node ID selector (S1) Pos. 0 F ID 16 31 2 1 F E D 3 4 C 5 B 6 7 9 A 1 2 3 4 5 6 7 8 1 2 1 2 3 X3 X2 X1 Mounting 1. Insert the RTAC-03 carefully into a free slot on the AIMA-01 I/O Module Adapter until the retaining clips lock the module into position. 2. Fasten the two screws (included) to the stand-offs. Note: Correct installation of the screws is essential for fulfilling the EMC requirements and for proper operation of the module. Installation

19 Wiring Terminal designations X1 Marking Description 1 +24V +24 V power for 10 to 30 volt encoders (210 ma max.). 2 +5.5V +5.5 V power for 5 volt encoders (300 ma max.). 3 0V Common. X2 Marking Description 1 DI+ 2 DI- Digital input for position latching. 24 V logic < 5 V = 0, > 15 V = 1 Absolute maximum voltage: +30 V Absolute minimum voltage: -3 V The usage of this input depends on the application program of the drive; see the appropriate Firmware Manual delivered with the drive. X3 Marking Description 1 SHLD For earthing of the encoder cable shields. Internally 2 SHLD connected to the frame. 3 CHA+ Max. signal frequency: 200 khz 4 CHA- Signal levels: RS422/RS485, differential Input channels isolated from the logic, power supply, 5 CHB+ and earth 6 CHB- When the drive runs in the Forward direction, channel A should lead channel B by 90 (electrical) 7 CHZ+ Channel Z: One pulse per revolution (used in 8 CHZ- positioning applications only) Installation

20 Cable recommendation The encoder should be connected to the RTAC module with a cable specified below. Cable construction Conductor crosssectional area Maximum cable length 4 (2+1) Twisted pair cable with individual and overall shields. 0.5 to 1.0 mm 2 With a 5 volt encoder (+5.5 V output) (0.5 mm 2 cable): With a 5 volt encoder (+5.5 V output) (1.0 mm 2 cable): With 10 30 volt encoder (+24 V output) or external power supply: 30 m 60 m 100 m Note: The cable shields should be earthed only at the RTAC module if the pulse encoder is not isolated from the motor and earth. However, if the encoder is isolated from the motor and earth, the cable shields are to be connected to the encoder housing also. Note: Do not route the pulse encoder cables parallel to power (eg. motor) cables. Phasing When the pulse encoder is connected correctly, running the drive in the Forward (positive speed reference) direction should produce a positive encoder speed feedback. Installation

21 Wiring diagram Encoder output type: Push-pull Output pulse order in Forward rotation: 1, 2 (With encoders with 2 as the leading output, 1 and 2 should be wired to RTAC terminals B+ and A+ respectively. 1 and 2 should be wired to RTAC terminals B- and A- respectively.) Differential connection 1 2 RTAC X3 1 SHLD 1 2 3 SHLD A+ 1 4 A- VCC 0V 2 2 0 0 5 6 7 8 B+ B- Z+ Z- X1 1 +24V 2 +5.5V 3 0V Installation

22 Position latching The digital input on the RTAC-03 can be used for position latching provided it is supported by the application program. For more information, see the drive Firmware Manual. Programming the RTAC-03 The RTAC-03 is programmed through drive parameters. These parameters must be checked and adjusted. For further information, see the drive Firmware Manual. Installation

23 Fault tracing Diagnostic LEDs There are three diagnostic LEDs on the RTAC-03 module. CHA, CHB (Green) These LEDs show the activity on channels A and B as generated from the encoder output signal. WD/INIT (Yellow) Installation problems This LED shows the status of the module. The LED is lit when the drive is configuring the module at power-up. It can also be lit after power-up if an error occurs in the communication between the drive and the RTAC-03 (see Option slot installation below). Option slot installation In case the WD/INIT LED does not go out after about 5 seconds: The configuration has failed. Cycle the power supply of the drive. The module has a hardware failure. Ensure the 38-pin connector is properly inserted. Contact an ABB service representative. Fault tracing

24 AIMA-01 I/O Module Adapter installation There is no communication with the drive. Check that the drive is powered. Check the module node ID. Ensure the 38-pin connector is properly inserted. Check the parameter settings of the drive. Contact an ABB service representative. Fault tracing

C 4 25 Technical data Dimensions: 34 mm CHASSIS RTAC-03 TTL PULSE ENCODER INTERFACE GND 95 mm 1 2 3 4 5 6 7 8 1 2 SHLD SHLD CHA+ CHA- CHB+ CHB- CHZ+ CHZ- DI+ DI- X3 X2 CHA CHB WD/ INIT NODE ID B E D A 9 F 0 8 1 7 2 3 6 5 1 2 3 +24V +5.5V 0V X1 20 mm 62 mm Mounting: Into an option slot of the RMIO board of the drive or onto external I/O Module Adapter (AIMA-01). Degree of protection: IP20 Ambient conditions: The applicable ambient conditions specified for the drive in its Hardware Manual are in effect. Hardware settings: Rotary switch for node ID selection (range 16 31) Termination switches for encoder signals CHA, CHB and CHZ. Connectors: 38-pin parallel bus connector One 3-way, one 2-way, and one 8-way non-detachable screwtype terminal block for max. 2.5 mm 2 wire. Technical data

26 Encoder interface: Encoder type: TTL-type incremental pulse encoder with a supply voltage of 5 V or 10 30 V Encoder voltage output: 5.5 V DC (300 ma) or 24 V DC (210 ma), short-circuit proof, isolated Signals: CHA, CHB, CHZ (RS422/RS485, differential) Maximum frequency: 200 khz Maximum cable length: See table on page 20. Speed feedback resolution: 0.00305% (15 bits) Speed feedback accuracy: 50 ppm Isolated from the logic and earth Digital (position latching) input: 24 V logic <5V= 0, >15V= 1 Absolute maximum voltage: 30 V Absolute minimum voltage: -3 V Max. power consumption: 150mA (5V) + 300mA (24V) Estimated min. lifetime: 100 000 h Miscellaneous: All materials UL/CSA-approved Complies with EMC standards EN 50081-2 and EN 50082-2 Technical data

3AFE68650500 REV A EN EFFECTIVE: 10.02.2006 ABB Oy AC Drives P.O. Box 184 FIN-00381 HELSINKI FINLAND Telephone +358 10 22 11 Fax +358 10 22 22681 Internet www.abb.com ABB Inc. Automation Technologies Drives & Motors 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone 262-785-3200 800-HELP-365 Fax 262-780-5135 ABB Beijing Drive Systems Co. Ltd. No. 1, Block D, A-10 Jiuxianqiao Beilu Chaoyang District Beijing, P.R. China, 100015 Telephone +86 10 5821 7788 Fax +86 10 5821 7618