DUAL LEVELER/ LIMITER TOA 1000 series

Similar documents
TOA 900 SERIES II MIXER POWER AMPLIFIER

IMPORTANT SAFETY INSTRUCTIONS

LOXONE 12 Channel Amplifier

CX Zoner Installation & User Guide

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

Hear The Future...Now! SIEM-2T/SIEM-2R

DAB+ / FM Tuner Model: TU-201

OWNER'S MANUAL. AtlasSound.com PA601 COMMERCIAL AMPLIFIER. PA601 Commercial Amplifier. Power. Master

S/PDIF D/A Converter. User Manual. Rev.B, December 2011 Audial d.o.o Belgrade, Serbia

STEREO PREAMPLIFIER INSTRUCTIONS FOR USE

Achat 115MA full-range speaker. user manual

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual

BXR. Owner, s Manual. One hundred BASS EXTENDED RANGE P/N

CINEMA SB100 powered soundbar speaker

AM / FM Tuner + RDS. Model: TU

SUB 10 ACTIVE STUDIO SUBWOOFER

KEYBOARD EXTENDED RANGE. Sixty Owner, s Manual P/N

Features, Benefits, and Operation

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

SR-M1 Single -Woofer Monitor Speaker SR-M2 Twin -Woofer Monitor Speaker AC-M1 TOA PROFESSIONAL SOUND SYSTEM FLOOR MONITOR SPEAKER SYSTEM

*TD * ISA 280 ISA 450 ISA 750 ISA 1350 ISA 300Ti ISA 500Ti ISA 800Ti. Installed Sound Professional Audio Amplifiers.

Professional Disc Jockey Products 2001 Industries

EVID Compact Sound Speaker System

MODEL 2202IQ (1991-MSRP $549.00)

Congratulations! Thank you!

Safety Warnings and Guidelines

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

MCA Series Multi-Channel Amplifiers. Operation Manual

Line Level Converter Box. S Class Signal Processors

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

The Bouncer Bluetooth Stereo Speaker

OPERATION MANUAL. VDA-106A Video Distribution Amplifier. 1 st Edition - Rev.1

1402VLZ4 14-Channel. Compact Mixer. FEATURES: 14-channel mixer featuring our signature high-headroom, low-noise design APPLICATIONS:

Tone Hammer 500. Owners Manual. Manual Version 1.0

1 All safety instructions, warnings and operating instructions must be read first.

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

User and Installation Guide

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

Contents. Safety Warnings... 1

F(t) Forssell Technologies Inc

Instruction Manual. 5.1 Power Amplified Home Theatre Speaker System w/ Remote Control DSS-200

VOLUME AND TONE CONTROL - PREAMPLIFIER K8084

BXR 300C BXR 300R. Owner, s Manual P/N

XLS200 MKII. Subwoofer System OWNERS MANUAL

Perseus. Owner s Manual. Vacuum Tube Preamplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 02/01/06

MANUAL PC1000R

Kit Watt Audio Amplifier

CMP30. User Manual.

Zone Mixer. 6 channels configurable from 24 inputs. 3 zone outputs. Expandable via Sys-Link TM Built-in comp/limiter, ducking and alarm functions

COLOR VIDEO DOOR PHONE CDV-71BE/D

HDO700 P FIBRE OPTIC TRANSMITTER

How To Use The Gr8A Power Amplifier

AM/FM ALARM CLOCK RADIO

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

64-CHANNEL INTEGRATED AMPLIFIER

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CV-5000 HEAVY DUTY PROFESSIONAL AMPLIFIER

To reduce the risk of electrical shocks, fire, and related hazards:

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

MC300 POWER AMPLIFIER

24 Wide Screen LED Monitor with HDMI

PLA PLA-4300D Class-D Mono Block Power Amplifier. Two Channel High Performance Power Amplifier. Four Channel High Performance Power Amplifier

PRO MPA II. ART PRO MPA II Microphone Preamplifier USER S GUIDE

POWER AMPLIFIER STEREO VERSTÄRKER AMPLIFICADOR DE PODER ESTEREO AMPLIFICATEUR DE PUISSANCE STÉRÉO

Operation Manual for Users

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

INSTRUCTIONS FOR USE Pro-Ject Tube Box S

5 CHANNEL MIXER. S Class Signal Processors

Digital FM/AM Receiver

TUBE-TECH HLT 2A Stereo High- and Low shelving, T- filter & Low- and High cut

Replacing the vacuum tube

Owner s Manual channel amplifier

Gemini II. Subwoofer System OWNERS MANUAL

VACUUM TUBE COMPRESSOR

MA-4150 ORDERCODE D6149 Highlite International B.V.

CELO5. User & Installation Manual.

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

LT-82 Stationary IR Transmitter

Hegel H1 High End Integrated Amplifier

FREQUENCY RESPONSE ANALYZERS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Operation Manual. Multi Channel Power Amplifier DPA-430L

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

X 1400 X Channel Amplifier Instruction Manual

SZI IR Audio Transmission Technology Modulators/Radiators

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

Single Day Alarm Clock with. Bluetooth and USB Play-through

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

DAB2+ Dear Customer, Congratulations with your new Argon DAB2+

MIDI control allows the Split Personality to be used remotely in rack systems, or integrated into MIDI controlled setups for easy preset recall.

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

Stage 112. Owner, s Manual P/N

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

PA-2000/PA-4000/ PA-2000R/PA-4000R Public Address Amplifier

ELECTRICAL AUDIO EApreq

Owner s Manual Please read before using this equipment. 4-Channel Stereo Mixer

6 X 100Watt Class-D Audio Amplifier Board- TDA7498 User s Guide

Transcription:

Operating Instructions DUAL LEVELER/ LIMITER TOA 1000 series L-1102 CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL THE LIGHTNING FLASH WITH ARROWHEAD WITHIN A TRIANGLE IS INTENDED TO TELL THE USER THAT PARTS INSIDE THE PRODUCT ARE A RISK OF ELECTRIC SHOCK TO PERSONS. THE EXCLAMATION POINT WITHIN A TRIANGLE IS INTENDED TO TELL THE USER THAT IMPORTANT OPERATING AND SERVICING INSTRUCTIONS ARE IN THE PAPERS WITH THE APPLIANCE. Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference. TOA Corporation

Contents Handling precautions General description Features Nomenclature Front panel Rear panel Connections Operation Matching transformer mounting Block diagram Appearance Specifications Accessories 2 2 2 3 4 4 5 6 7 7 8 8 Handling Precautions 1. Operating power voltage is local mains voltage plus or minus ten percent. 2. Keep chemical and beverages away from the unit. 3. To avoid severe electric shocks and possible catastrophic damage, always refer servicing to qualified technical service personnel when component malfunctions occur. General Description Features The TOA L-1102 functions as a leveler or as a limiter, which can be selected with a switch. It contains two leveler/limiter units (CH1 and CH2), and each channel is equipped with a noise gate. The L-1102 is mountable in an EIA standard 19" rack (1-unit size). Dual leveler/limiter unit system. Either function can be selected for each unit with a switch. If the limiter is selected, speakers can be protected regardless of amplifier gain because the power amplifier output is used as a sense input. If the leveler is selected, an output level can be adjusted within the range of 0 db ~20 db. Gain reduction meter to check the unit's operation. Noise gate for each channel. Electronically-balanced input and output. Optional transformers LT-101 (input) and LT- 102 (output) enable transformer-balanced input and output. Security cover. 2

Nomenclature < Front Panel > Noise Gate Switch and Gate Standby Indicator Press this switch to put the noise gate in standby mode, and the standby indicator lights. To disable the noise gate, press the switch again, and the indicator is extinguished. Noise Gate Threshold Control Sets up the threshold of noise gate input within the range of from -80 db to -40 db. Noise Gate Indicator Lights when an input signal level is lower than a predetermined threshold value, and is extinguished when exceeding the threshold value. Leveler/Limiter Select Switch and Selection Indicator The switch selects either a leveler or a limiter. The leveler's indication lamp lights if the leveler is selected, and the limiter's indication lamp lights if the limiter is selected. Leveler/Limiter Threshold Control Adjusts the leveler's threshold level within the range of from -40 db to 0 db, or the limiter's threshold level from 1V to 100V rms. Output Level Control This control is effective only when the leveler is selected. It adjusts the output signal level within the range of 0 db~20 db (from "0" to "10" in 2 db steps). Gain Reduction Meter Indicates the output comperession with respect to the input for a maximum of 30 db. Bypass Switch and Bypass Indicator When this switch is pressed, as indicated by its indicator, all input signals bypass the unit for direct output. Signal Indicator Lights when an input signal level exceeds -30 db. Stereo Linkage Switch and Indicator Press this switch (its indicator lights) when stereo L and R signals are input into both channels, CH1 and CH2. Operation of both channels depends on the leveler/limiter threshold control setting for CH 1. All other switches and controls can be used independently for operation of each channel. [Note] : For stereo applications, the same function (i.e. either a leveler or limiter) must be selected for both channels. Power Switch and Indicator Press this switch to turn power ON (indicator lights). To turn power OFF, press this switch again (indicator is extinguished). Security Cover Mounting Hole Used to mount the security cover with the supplied screws to avoid accidental changes in control and switch settings. 3

Nomenclature < Rear Panel > AC Fuse Holder When replacing, be sure to use the fuse of specified rating and type to avoid the possibility of fire. AC Power Cord Plug this cord into the wall AC outlet. Ground Screw Terminal Hum can result from a ground loop to be formed when the L-1102 is connected to other equipment. In such cases, cut the loop by removing a shorting piece. Usually, mount the shorting piece to the terminal. Sense Input Screw Terminal Connect this terminal to the power amplifier output of each channel when in "limiter" mode. See to it that the polarities of power amplifier output and sense input terminal are matched. Output Screw Terminal The output terminal is electronically-balanced. Place the supplied shorting piece between E and C to convert into unbalanced type. Input Screw Terminal The input terminal is electronically-balanced. Place the supplied shorting piece between E and C to convert into unbalanced type. Connection Examples 1. If using as a leveler 2. If using as a limiter Power amp. input To mixer, preamplifier, etc. Speaker output To mixer, preamplifier, etc. Power amp. input Speaker output 1000 series Power amplifier 1000 series Power amplifier Speaker Speaker 4

Operation Leveler/Limiter Threshold Setting 1. Limiter (Speaker protection) Power amplifier output is input into the sense input screw terminal as a sense signal. If the sense signal level exceeds a predetermined threshold value, the limiter compresses the output. As can be seen from a compression curve in the figure below, the output amplitude is linear with respect to the input up to the threshold (A) and gentle and constant thereafter for compression in the ratio 10 (input) to 1 (output). (The leveler/limiter threshold control knob points to the threshold A.) POWER AMP OUTPUT INPUT 2. Leveler If the input signal level exceeds a predetermined threshold value, the output is compressed. The overall output level can be adjusted within the range of 0 db~20 db ("0"~"10" in 2 db steps) using the output level control. OUTPUT INPUT 5

Matching Transformer Mounting CAUTIONS THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL The L-1102's input and output are electrically balanced. These can be converted to transformer balanced types using the optional matching transformer LT-101 (input) and LT-102 (output). 1. Set the power switch to OFF and unplug the AC cord from a wall outlet. 2. Remove ten side panel screws to remove the case. 3. For input conversion, first fix two sleeves (supplied with the transformer) to the lefthand side, as viewed from the front, by tightening two screws from the outside of a bottom chassis, and then place the input transformer on the sleeves and fix it using two screws. See Fig. 1. After installing the transformer, detach connector CN35 from CN1, reconnect it to connector (a) at the transformer side, and connect connector (b) coming from the transformer to CN1, as shown in the figure. 4. Similarly, install the output transformer at the right-hand side for output conversion. And then, detach connector CN2 from CN36, reconnect it to connector (c) at the transformer side, and connect connector (d) coming from the transformer to CN36. 5. Replace the case. Fig.1 [Note] : (1) Follow the same procedure as the above to enable transformer-balanced input and output for channel 2. (2) When installing the transformer, never touch other internal components other than those described above as severe electric shocks may result. Transformer Specifications Model Impedance Frequency response Constant loss Distortion LT-101 30Hz~20kHz(±0.15dB) Within 1.5dB (1kHz) Under 0.2% (+5dB*, 50Hz) LT-102 30Hz~20kHz(±0.15dB) Within 1.5dB (1kHz) Under 0.2% (+5dB*, 50Hz) 0dB = 0.775V RMS Specifications are subject to change without notice. 6

Block Diagram Appearance Unit mm (in.) 7

Specifications Power Requirements AC Mains, 50 Hz/60 Hz Power Consumption 14W (120V AC version) 15W (220/240V AC version) Frequency Response 20~20kHz (±1 db) Total Harmonic Distortion Under 0.1% (1 khz, rated output) Under 0.2% (1 khz, 30 db compression) Input +4 db* for load (electronically balanced) Output + 4 db* for load (electronically balanced) Maximum Input Level + 20 db* Maximum Output Level + 20 db* Sense Input (electronically balanced) Noise Level Under 92 db* (IHF-A) Threshold Level Range Leveler: 40 to 0 db* (with respect to input) Limiter: 1~100V rms (with respect to sense input) Noise Gate Threshold Range 80 to 40 db* Adjustable Output Range 0 to +20 db Attack Times Dependent on input (or sense input) signal Release Times Dependent on input (or sense input) signal Finish Black Dimensions 482.6(W)X44.0(H)X316.8(D) mm [19.00X1.73X12.47 in.] Weight 4kg (8.8 Ib.) 0dB = 0.775V RMS Specifications are subject to change without notice. Accessories Security cover Security cover mounting screws Fuse 250V 0.3A (120V AC version) Fuse 250V T100mA 220/240V AC version) Shorting pieces Operating instructions Rack mounting screws 1 2 1 1 4 1 4 TOA Corporation KOBE, JAPAN 133-12-110-00