Loctite Spray Valve Part Number 98520

Similar documents
MP-4V Heavy Duty Riveter / 39048

Stainless Steel Single and Dual Circulation Kits

MODEL G300 BRAKE BLEEDER

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

OP300S / OP350 2:1 RATIO TRANSFER PUMP

Fluid Regulator. Instructions Parts List L LOW PRESSURE

TITAN 13 x 2 ½ BRAKES

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

PAINT SPRAY GUN WASHER

8 ton air/hydraulic long ram jack

Style 9168 Field Service Kit Black Max Piston intake valve

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

PALLET JACK TON

BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN

Instructions and precautions. Fork Height. Visit our website at:

Installation Instructions S

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Part I - Installation

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

This instruction is valid for all ACD pump models shown on page 2

AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: SE-100-1, SE-200-1, SE-500-1, and SE FORM NO. L H-0814

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

758 Heavy-duty Ratchet Guy Wire Cutter

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

2006 HEADSHOK Service Video #1

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Installation Instructions

STC 3S A Series Solenoid Valves

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

tire inflator with pressure gauge

MODEL T200-F18 MODEL T125-F18 Finish Nailers

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

AIR HYDRAULIC RIVETER

OPERATING INSTRUCTION MANUAL FOR S-240 HYDRAULIC CUTTERS WITH PARTS LIST

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Series Hose Reels

MaxiMist Spraymate By Earlex

Installation and Maintenance Instructions

REPAIR AND MAINTENANCE MANUAL

Installation and Maintenance Instructions

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System

Installation Instructions / Warranty

PILOT SL & XC SERVICE GUIDE

Self Purging Liquid Trap (SPLT ) User s Manual

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

TECHNICAL SERVICE MANUAL

55-Gallon Dispenser Package

Ozone Generator Manual

PNEUMATIC PLANISHING HAMMER

ROTOR LOADER OWNER S MANUAL

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Mini-led spotlight with magnetic base

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Installation, Maintenance, & Repair Series 4000B/LF4000B

INSTALLATION & OPERATING INSTRUCTIONS

2:1 RATIO TRANSFER PUMP

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Installation Instructions / Warranty

OAK WORKBENCH WITH 2 DRAWERS

OWNER'S MANUAL P O L Y C A R T, 1 7 C U B I C F O O T M O D E L : P C T B H. Assembly Installation Operation Repair Parts

BUNK BED. Model No.: DA3797E - Espresso DA3797P- Pine. UPC CODE: (Espresso) (Pine) NOTE: Lot number: Date of purchase:

Round Housing with Side Ports

SINGLE STAGE INLINE FIRE PUMP

HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Auto-belay Cable Replacement Process

12-Volt Negative Ground Installation Instructions

P8 MAXI-LUBE AIR OPERATED GREASE PUMP

Tri-Homo Style Operation and Maintenance Instructions

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Installation Instructions / Warranty

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Rexroth Hydraulic Pump A10VO Series User Manual

81000 Series Aluminum Gate Valve Installation and Repair Manual

Hydraulic Punch Driver Kit

Machine needle shut-off nozzle type HP

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

3/4 PIPE CLAMP WITH STAND

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

Operating Instruction Manual For S-40B Hydraulic Cutters With Parts List

GEAR BOXES MAXIMUM LOAD LIMITS: SpaceCadet. SpaceBooster. RocketBox. box weight. box contents

Installation Instructions

Transcription:

EQUIPMENT Operation Manual PN 98520 Loctite Spray Valve Part Number 98520

Table of Contents 1 Please Observe The Following... 3 1.1 Emphasized Sections... 3 1.2 For Your Safety... 3 1.3 Unpacking and Inspection... 3 1.4 Items supplied... 4 1.5 Features... 4 2 Description... 4 3 Technical Data... 5 4 Installation... 5 4.1 Connecting The Valve... 5 5 Operation... 6 5.1 Operating Instructions... 6 5.2 Spray Area Coverage By Round Nozzle... 6 6 Troubleshooting... 7 6.1 Troubleshooting Guide... 7 7 Care and Maintenance... 8 7.2 Needle/Piston Assembly and Seal Replacement (See Section 9)... 9 7.3 Nozzle and Air Cap Replacement (See Section 9)... 9 7.4 Seat Replacement (See Section 9)... 9 8 Accessories and Spare Parts... 10 9 Valve Illustrations... 10 10 Warranty... 11

1 Please Observe The Following 1.1 Emphasized Sections Warning! Refers to safety regulations and requires safety measures that protect the operator or other persons from injury or danger to life. Caution! Emphasizes what must be done or avoided so that the unit or other property is not damaged. Notice: Gives recommendations for better handling of the unit during operation or adjustment as well as for service activities. 1.2 For Your Safety For safe and successful operation of the unit, read these instructions completely. If the instructions are not observed, the manufacturer can assume no responsibility. Do not operate this unit in excess of maximum ratings/settings. Always wear appropriate personal protective eyewear, clothing or apparel when operating or cleaning/servicing the equipment. The fluid being dispensed may be toxic and/or hazardous. Refer to Material Safety Data Sheet for proper handling and safety precautions Use only original equipment replacement parts. Always disconnect the power supply before servicing the unit. Observe general safety regulations for the handling of chemicals such as Loctite adhesives and sealants. Observe the manufacturer s instructions as stated in the Material Safety Data Sheet (MSDS). While under warranty, the unit may be repaired only by an authorized Loctite service representative. 1.3 Unpacking and Inspection Carefully unpack the Loctite Spray Valve and examine the items contained in the carton. Inspect the unit for any damage that might have occurred in transit. If such damage has occurred, notify the carrier immediately. Claims for damage must be made by the consignee to the carrier and should be reported to the manufacturer.

1 Please Observe The Following (continued) 1.4 Items supplied Loctite Spray Valve 98520 Spray Nozzle Kit.046 orifice 989270 Hose Connections 2 x 48 Mounting Bracket 985281 with screw and hex key Air and product fittings attached to valve at factory 1.5 Features Items # Description 1 Stroke Control Adjustment Knob 2 Valve-actuating Air Inlet Port 3 Fluid Inlet Port 4 Removable Spray Cap 5 Atomize Air Inlet Port 1 2 5 PN 98520 3 4 2 Description Loctite Spray Valve provides an effective solution to automatic spraying of low viscosity primers, lubricants, and compatible fluids up to 1200 cp. The valve is best operated in conjunction with the Loctite Spray Valve Controller 98521 for providing consistent spray coverage over a wide range of operating conditions.

PORT A PORT B MODE DECIMAL MODE/TIME SET MODE/TIME DISPLAY 3 Technical Data Size 104.1 x 25.4 mm (4.1 x 1.0 ) Weight 331g (0.73lb) Fluid Inlet Port 1/8 NPT female Air Inlet Port 10-32 UNF-2B Atomize Air Inlet Port 10-32 UNF-2B Fluid Pressure 100 psi (6.9 bar) maximum Activation Pressure 70 psi (4.8 bar) minimum Wetted Parts 303 stainless steel, Acetal, PTFE Air Cylinder Material 303 stainless steel Operating Frequency Exceeds 400 cycles/min. 4 Installation 4.1 Connecting The Valve Item Description # 1 From air source 2 Air Filter -985397 3 Constant air flow 4 Valve Air Hose (included) 5 Atomize Air Hose (included) 6 Fluid Feed Hose (optional) 7 Bond-A-Matic 3000 (optional) 8 Spray Valve Controller (98521 optional) 6 2 1 3 4 7 5 PN 98520 98520 Valve 8

5 Operation Nozzle size 5.1 Operating Instructions 1. Set valve air pressure at Valve Controller to 70 psi (4.8 bar). 2. Set the atomize air pressure at Valve Controller according to the viscosity of fluid being spray. 3. Set fluid pressure at Fluid Reservoir according the viscosity of fluid being sprayed; do not exceed 100 psi (6.9 bars). 4. Place a waste bucket under the valve spray nozzle and purge the valve until the fluid flows steadily. Spray coverage is determined by: Stroke control adjustment Rotate Stroke Control Knob clockwise to decrease flow rate and counterclockwise to increase flow rate. DO NOT rotate the knob beyond the Line Marker which is labeled on the knob shaft. Length of actuation as set at Valve Controller (the valve-on time) Fluid reservoir pressure Fluid viscosity Distance between the spray nozzle and the sprayed surface 5.2 Spray Area Coverage By Round Nozzle 1 (25.40mm) 2 (50.80mm) Distance from Sprayed Surface 3 4 (76.20mm) (101.60mm) 5 (101.60mm) 6 (152.40mm) Spray area coverage (diameter) 0.046 0.25 0.50 0.75 1.00 1.25 1.50 (1.17mm) (6.35mm) (12.70mm) (19.05mm) (25.40mm) (31.75mm) (38.10mm) 0.028 0.20 0.40 0.60 0.80 1.00 1.20 (0.71mm) (5.08mm) (10.16mm) (15.24mm) (20.32mm) (25.40mm) (30.48mm) 0.014 0.17 0.34 0.50 0.65 0.85 1.00 (0.36mm) (4.32mm) (8.64mm) (12.70mm) (16.51mm) (21.59mm) (25.40mm) *Spray area coverage shown in above charts is for reference only. Actual coverage area depends on fluid viscosity and characteristics.

6 Troubleshooting 6.1 Troubleshooting Guide PROBLEM POSSIBLE CAUSE CORRECTION No fluid flow Inconsistent fluid flow Fluid drools after the valve closes, eventually stopping Fluid flows through nozzle but will not spray Steady drip Fluid pressure too low Operating pressure too low Valve is not actuating Fluid cured in valve chamber Stroke control adjustment not activating or engaged Fluid pressure fluctuating Valve operating pressure is too low Valve opening time is not consistent Air trapped in Fluid Housing Air trapped in Fluid Housing Post-spray time is too short Atomize pressure is too low Dirty Needle and Acetal Seat Acetal Seat is worn or damaged Fluid pressure exceeds 100 psi (6.9 bars) Valve reassembled incorrectly Increase fluid pressure at Fluid Reservoir Increase air pressure to 70 psi (4.8 bars) at Valve Controller Check Valve Controller for air pressure level to valve Disassemble and clean valve thoroughly Engage by rotating the Stroke Control Adjustment Knob counterclockwise (but not beyond the Line Marker ) Make sure fluid pressure is constant Increase valve pressure to 70 psi (4.8 bars) at Valve Controller Check to make sure the Valve Controller is providing a consistent air pressure output Purge air from valve Purge air from valve Increase post-spray time at Valve Controller Increase atomizing pressure at Valve Controller Thoroughly clean Needle and Seat Replace worn or damaged part Lower fluid pressure at Fluid Reservoir until dripping stops Disassemble and reassemble valve according to instructions

7 Care and Maintenance Tool/Material required (one each): open-end wrench, snap-ring pliers, soft brush, o-ring grease, wooden dowel and thumb screw (included). Cleaning agent recommended: Isopropyl Alcohol or equivalent solvent. 7.1 Cleaning (See Section 9) (Repair kit 989271 recommended) 1. Release fluid pressure at Fluid Reservoir. 2. Disconnect fluid line and valve air hoses from valve. 3. Remove Stroke Control Adjustment Knob (19) by rotating it counterclockwise beyond the Line Marker; the knob is loosen as it is pushed by the Compression Spring. 4. Remove the Compression Spring (1) and the two Mylar Washers (18) on each end of the Compression Spring. 5. Using the open-end wrench to remove the Locking Cap (8) and then pull the Air Cap (11) out from the Fluid Housing (7). 6. Using the open-end wrench to remove the Nozzle (9) along with the Spacer (13); replace O-ring if it is damaged. 7. Hold Fluid Housing (7) and rotate the Air Cylinder/Needle Assembly (2) counterclockwise. When completely un-threaded, pull the two valve segments straight apart to separate. 8. Using the soft brush to clean Fluid Housing (7), Needle/Piston Assembly (17) and Nozzle (9) with Isopropyl Alcohol. 9. If the valve is leaking, using the Thumb Screw (TSD1113-28) to remove the Seat (10) and replace it with a new one; refer to Section 7.4 Seat Replacement for instructions. 10. Reinstall Nozzle (9), Spacer (13), Air Cap (11) and Locking Cap (8) into Fluid Housing (7). 11. Lubricate O-ring (6) with grease then reassemble the Air Cylinder/Needle Assembly (2) into Fluid Housing (7). 12. To reinstall Compression Spring (1) by first placing one Mylar Washer over the Needle/Piston Assembly (17), then the other Mylar Washer into the Stroke Control Adjustment Knob (18) and followed by the Compression Spring. 13. Reinstall the Stroke Control Adjustment Knob (19) by rotating it clockwise until it stops and then counterclockwise to the desired setting BUT NOT beyond the Line Marker on the knob shaft.

7 Care and Maintenance (continued) 7.2 Needle/Piston Assembly and Seal Replacement (See Section 9) (Repair Kit 989273 required) 1. Follow Step# 1-7 in previous section (Section 7.1). 2. Replace O-ring (6) if damaged. 3. Remove Cup Seal (14) from Fluid Housing (7). 4. Use the snap-ring pliers to remove the first Retaining Ring (3). 5. Pull the Needle/Piston Assembly (17) straight out from the Air Cylinder (2). 6. Use the Snap-ring pliers to remove the second Retaining Ring (15). 7. Remove the Nylon Washer (16) and O-ring (5); replace these parts if damaged. 8. Reinstall O-ring (5), Nylon Washer (16) and secure with a Retaining Ring (14). 9. Reinstall Needle/Piston Assembly (17) and secure with the other Retaining Ring (3). 10. Reinstall Cup Seal (14) into Fluid Housing (7) using a soft rod (such as a wooden dowel). 11. Follow Step# 9-13 in previous section (Section 7.1). 7.3 Nozzle and Air Cap Replacement (See Section 9) (Nozzle kits 989268, 989269, 989270) 1. Remove Stroke Control Adjustment Knob (19) by rotating it counterclockwise and beyond the Line Marker position. 2. Remove the Compression Spring (1) and the two Mylar Washers (18) on each end of the Compression Spring. 3. Using the open-end wrench to remove the Locking Cap (8) and then pull the Air Cap (11) out from the Fluid Housing (7). 4. Using the open-end wrench to remove the old Nozzle (9) and Spacer (13). 5. Reinstall Spacer (13) and using the open-end wrench to reinstall new Nozzle (9), make sure the O-ring is on the Nozzle; do not over tighten the Nozzle. 6. Install new Air Cap (11) and then secure it with the Locking Cap (8). 7.4 Seat Replacement (See Section 9) (1 replacement seat is included with kit 989271 and 1 with each spray nozzle orifice kit, 989268, 989269, or 989270) 1. Insert the Thumb Screw inside the Nozzle (9) and rotate clockwise to attach to the Seat (10). 2. Secure the Nozzle on a soft jaw vise and then pull the Thumb Screw, with the Seat attached, straight out. 3. Install the new Seat on the Thumb Screw and then insert the Thumb Screw straight into the Nozzle. To ensure proper seat alignment, it is recommended that the seat installation is done on an Arbor Press.

8 Accessories and Spare Parts Spray Nozzle Kit -.014 Orifice Item 989268 Spray Nozzle Kit -.028 Orifice Item 989269 Spray Nozzle Kit -.046 Orifice Item 989270 Spray Valve Seal Kit Item 989271 Spray Valve Hose and Fitting Kit Item 989272 Spray Valve Piston Repair Kit Item 989273 Spray Valve Air Actuator Item 989371 9 Valve Illustrations 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 Thumb Screw Seat O-ring Nozzle

10 Warranty Henkel expressly warrants that all products referred to in this Instruction Manual for (Loctite 98520 Spray Valve) (hereafter called Products ) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, as its option, to replacing those Products which are shown to be defective in either materials or workmanship or to credit the purchaser the amount of the purchase price thereof (plus freight and insurance charges paid therefor by the user). The purchaser s sole and exclusive remedy for breach of warranty shall be such replacement or credit. A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted in writing within one month after discovery of the defect or after the time the defect should reasonably have been discovered and in any event, within (12) months after the delivery of the Products to the purchaser. This warranty does not apply to perishable items, such as, but not limited to: (o-rings, seals, washers, filters, lights, etc.). No such claim shall be allowed in respect of products which have been neglected or improperly stored, transported, handled, installed, connected, operated, used or maintained. In the event of unauthorized modification of the Products including, where products, parts or attachments for use in connection with the Products are available from Henkel, the use of products, parts or attachments which are not manufactured by Henkel, no claim shall be allowed. No Products shall be returned to Henkel for any reason without prior written approval from Henkel. Products shall be returned freight prepaid, in accordance with instructions from Henkel. NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED, MISUSED, NEGLECTED, OR DAMAGED BY ACCIDENT, OR IF THE SYSTEM WAS USED TO DISPENSE ANY LIQUID MATERIAL OTHER THAN LOCTITE PRODUCTS. EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, HENKEL MAKES NO WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS. ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND OTHER WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR TRADEMARK INFRINGEMENT) ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY THE PURCHASER. THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS. WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH, THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS AND SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE.

Henkel Corporation 1001 Trout Brook Crossing Rocky Hill, CT 06067-3910 Henkel Automotive Technology Center 2455 Featherstone Road Auburn Hills, Michigan 48326 Henkel Canada Corporation 2225 Meadowpine Boulevard Mississauga, Ontario L5N 7P2 Henkel Ltda. Rua Karl Huller, 136 Jd. Canhema 09941-410 Diadema/SP, Brazil Henkel Capital, S.A. de C.V. Calzada de la Viga s/n Fracc. Los Laureles Loc. Tulpetlac, C.P. 55090 Ecatepac de Morelos, Edo. de México www.loctite.com Loctite is a trademark of Henkel Corporation, U.S.A. Copyright 2004. Henkel Corporation All rights reserved. Data in this operation manual is subject to change without notice. Manual P/N: 989372, Date:04/2005