How to Choose the Right Pump

Similar documents
SIZING OF WATER PIPING SYSTEM

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

CHAPTER 2: The Plumbing System

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Pipe Sizes For Water Distribution System Design

Pressure Drop Basics & Valve Sizing

Leak Detector Guide. Your Guide to Home Water Conservation

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Utility Service Application

LEAK DETECTION GUIDE

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

Common Causes of High Water Bills

One of the fundamental design elements that every

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Section 4 Page 2. Flow in Pipes

A High Bill Usually Means a Leak

Home comfort: water heating

What Does A Sump Pump Do?

SIZING AND CAPACITIES OF GAS PIPING

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Pacific Pump and Power

Module 9: Basics of Pumps and Hydraulics Instructor Guide

PLUMBING CODE REQUIREMENTS AND SIZING GUIDE FOR RESIDENTIAL WATER SOFTENERS. Second Edition. Prepared by

Goulds Water Technology

FILLING AND PURGING THE SYSTEM

Sizing Plumbing Water System

FIRE SPRINKLERS IN TOWNHOMES/CONDOMINIUMS

Research of Grey Water for Use in Residential Applications Original date of publication: Updated:

Water Pressure Reducing Valves

detection kit the water leak water leaks: What you should know A helpful guide for locating indoor and outdoor water leaks Getting Ready

What to Expect From the Examination. How to Study the Plumbing Codes

Centrifugal Fans and Pumps are sized to meet the maximum

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Septic Tank to Cistern Conversions. Saving Water & Saving Money

2016 BUILDING PERMIT FEES*

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Energy and Cost Required to Lift or Pressurize Water

Model 1210C Battery Powered Pump Shown. Description

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

Fire Pump Plan Review March 2010

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

The Jockey Pump, an Important Part of a Fire Pump System.

Water Saver Bingo. Objectives:

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Sta-Rite Industries Basic Training Manual

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

Water Heater Sizing TS Saturday 2:15pm 5:15pm J. Joe Scott CPD, FASPE, LEED

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

City of Modesto WATER-USE HOME SURVEY

How To Calculate An Average Daily Flow

WATER & SEWER SERVICES

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Graywater System Guidelines

Fan Applications & System Guide

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

SPP Pumps Inc. Atlanta

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

HYDROSTATIC TEST PUMPS

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.


Do-It-Yourself. Home Water Survey

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

NAVIEN AMERICA INC FITCH AVENUE

The conditions below apply to the curves shown on the following pages.

Protect Your Home From Flooding. A guide for Lethbridge Residents

PLUMBING ROUGH IN INSPECTION

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

RESIDENTIAL WATER SURVEY

Frequent occurrences of basement flooding can result in long-term damage to the building and equipment that may not be covered by insurance.

1. Description. 2. List of Accessories included A B C F G H

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

SANITARY SEWER SPECIFICATIONS

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Pressure Reducing Valve Calculation Example

WATER LEAK DETECTION G

DRAFT ONLY ORDINANCE NO.

Get more from your hot water

Septic System Management Plan for Below Grade Systems

Selection Of Centrifugal Pumping Equipment 1

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

Please also see 10 golden rules for correct Saniflo installation on

To many people, a home s plumbing system is perceived as being extremely

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

Transcription:

How to Choose the Right Pump Making the right choice for your pump is important because you need to have enough pressure and flow to meet the demands of the systems which use the rainwater you ve collected. After all that s what you collected it for, right? So we ve compiled and simplified this information so you can make the right pump choices without having to go through pump school. Determining Pump Requirements: The first step in choosing a pump is to determine what purposes the water will be used for so we can get an idea on the volume of water (GPM) and the pressure requirements (PSI). GPM demand is determined by adding all of the possible simultaneous requirements from the various demands on the water system. For example, if you have an 8 zone irrigation system, you probably won t have more than 1 zone will be running at any given time, so only the GPM of the most demanding zone should be used. However, if you will also be using your water to flush toilets, then we need to add about 3 GPM to the requirements since the toilet may run at the same time as the irrigation. For typical water demands, see Page 3. PSI (pressure) requirements are derived by simply finding which of your water devices needs the most pressure. Anything else which cannot withstand that pressure will require a pressure regulator. For example, a drip irrigation system usually requires a minimum of 25 PSI and comes with its own regulator whereas most other fixtures like sprinklers, toilets and urinals, washing machines and hose bib attachments require about 40 45 PSI. The next step is to add the remainder of what the industry calls Dynamic Head so we can define the Total Dynamic Head (TDH) requirements. There are only two major components left to identify (there are other factors but are comparatively insignificant): Vertical lift: The vertical lift component is simply the distance (in feet) between the bottom of the pump intake and the highest point of demand in your system. For example; if you are using a submersible pump in an underground tank, and your highest sprinkler head is 20 feet higher than the bottom of the tank, then the vertical lift component is 20 feet. This is added directly to the dynamic head requirements. Friction loss: Friction loss is generally derived using charts and tables to determine how hard the pump has to work just to push the water through the pipes. There are basically two components: Horizontal distance and friction. For example: 100 of 1 Sch 40 PVC pipe at 15 GPM adds 14.63 of TDH to the equation. To determine this precise number, refer to the charts and tables on Page 4. As a general rule in design, larger pipes, shorter distances and limiting the number of 90 degree elbows in the system are best for performance. Page 1 3/1/2009

Completing the Total Dynamic Head equation: We now have 4 components: GPM, PSI, Vertical Lift and Friction Loss: 1. Your GPM demand will be matched with a corresponding pump GPM output by crossreferencing your TDH and the GPM on a pump performance curve chart (example on Page 5) to finalize your pump choice. 2. PSI is converted into its TDH component by multiplying the maximum PSI requirement by 2.31. For example, if your system requires 40 PSI then you need to add (40 X 2.31) 92.4 feet of TDH to the requirements. 3. Vertical lift is directly added to the TDH requirement. If you have 20 feet of maximum lift, then add 20 feet to the requirements. 4. Friction loss components are added together and the sum is directly added to the TDH requirements. Sample environment: We have a site where we have 8 irrigation zones and we also want to be use rainwater for two lavatories: A. Sprinkler Zones: The largest sprinkler zone requires 40 PSI, it has 5 sprinkler heads using a total of 12 GPM; the highest elevation requires 18 feet of vertical lift. We have also calculated approximately 20 feet of friction loss in the most demanding zone. Requirement: ((40 psi X 2.31) + 18 + 20), or (92.4 + 18 + 20), or 130.4 feet of TDH. The sprinkler system requires 12 GPM (save for cross reference). B. Lavatories: We ve determined that operation of 2 lavatories requires approximately 7 GPM and will operate using the same pressure as the irrigation system. The toilets are lower in elevation than the highest sprinkler zone so there is no additional vertical lift. We have calculated 5 feet of friction loss so we add 5 feet of TDH at 7 GPM for the lavatories. Total requirements: (130.4 + 5) = 135.4 of TDH at 19 GPM. (In this example, both lavatories can be flushed simultaneously with no performance impact on the most demanding sprinkler zone. Only you can decide if this is truly necessary). We cross reference this to the pump performance curve on Page 5 and determine that the 1 HP 1SC51E1HA submersible pumps will meet those demands. If a modest impact on irrigation performance is allowable while flushing lavatories, or if there are no lavatories in the equation, then a ¾ HP 1SC51D1GA submersible pump will deliver satisfactory performance. Page 2 3/1/2009

Typical Water Demands PRIVATE RESIDENCES Outlets Flow Rate GPM Total Usage Gallons Bathrooms in Home 1 1½ 2-2½ 3-4 Shower or Bathtub 5 35 35 35 53 70 Lavatory 4 2 2 4 6 8 Toilet 4 5 5 10 15 20 Kitchen Sink 5 3 3 3 3 3 Automatic Washer 5 35 18 18 18 Dishwasher 2 14 3 3 Normal seven minute* 45 70 98 122 peak demand (gallons) Minimum sized pump required to meet peak demand without 7 GPM (420 GPH) 10 GPM (600 GPH) 14 GPM (840 GPH) 17 GPM (1020 GPH) supplemental supply Notes: Values given are average and do not include higher or lower extremes. * Peak demand can occur several times during morning and evening hours. ** Count the number of fixtures in a home including outside hose bibs. Supply one gallon per minute each. YARD FIXTURES FARM USE Garden Hose ½" Garden Hose ¾" Sprinkler Lawn 3 GPM 6 GPM 3-7 GPM Horse, Steer Dry Cow Milking Cow Hog Sheep Chickens/100 Turkeys/100 Fire 12 Gallons per day 15 Gallons per day 35 Gallons per day 4 Gallons per day 2 Gallons per day 6 Gallons per day 20 Gallons per day 20-60 GPM PUBLIC BUILDINGS Pump Capacity Required in U.S. Gallons per Minute per fixture for Public Buildings Total Number of Fixtures Type of Building 25 or 26-51- 101-201- 401- Over Less 50 100 200 400 600 600 Hospitals 1.00 1.00.80.60.50.45.40 Mercantile Buildings 1.30 1.00.80.71.60.54.48 Office Buildings 1.20.90.72.65.50.40.35 Schools 1.20.85.65.60.55.45 Hotels, Motels.80.60.55.45.40.35.33 Apartment Buildings.60.50.37.30.28.25.24 1. For less than 25 fixtures, pump capacity should not be less than 75% of capacity required for 25 fixtures. 2. Where additional water is required for some special process, this should be added to pump capacity. 3. Where laundries or swimming pools are to be supplied, add approximately 10% to pump capacity for either. 4. Where the majority of occupants are women, add approximately 20% to pump capacity. Page 3 3/1/2009

Friction Loss SCH 40 PLASTIC PIPE : F RICTION LOSS (IN FEET OF HEAD) PER 100 F T. GPM GPH 3 8" ½" ¾" 1" 1¼" 1½" 2" 2½" 3" 4" 6" 8" 10" ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 1 60 4.25 1.38.356.11 2 120 15.13 4.83 1.21.38.10 3 180 31.97 9.96 2.51.77.21.10 4 240 54.97 17.07 4.21 1.30.35.16 5 300 84.41 25.76 6.33 1.92.51.24 6 360 36.34 8.83 2.69.71.33.10 8 480 63.71 15.18 4.58 1.19.55.17 10 600 97.52 25.98 6.88 1.78.83.25.11 15 900 49.68 14.63 3.75 1.74.52.22 20 1,200 86.94 25.07 6.39 2.94.86.36.13 25 1,500 38.41 9.71 4.44 1.29.54.19 30 1,800 13.62 6.26 1.81.75.26 35 2,100 18.17 8.37 2.42 1.00.35.09 40 2,400 23.55 10.70 3.11 1.28.44.12 45 2,700 29.44 13.46 3.84 1.54.55.15 50 3,000 16.45 4.67 1.93.66.17 60 3,600 23.48 6.60 2.71.93.25 70 4,200 8.83 3.66 1.24.33 80 4,800 11.43 4.67 1.58.41 90 5,400 14.26 5.82 1.98.52 100 6,000 7.11 2.42.63.08 125 7,500 10.83 3.80.95.13 150 9,000 5.15 1.33.18 175 10,500 6.90 1.78.23 200 12,000 8.90 2.27.30 250 15,000 3.36.45.12 300 18,000 4.85.63.17 350 21,000 6.53.84.22 400 24,000 1.08.28 Friction Loss EQUIVALENT NUMBER O F FEET STRAIGHT PIPE FOR DI FFERENT FITTINGS Size of fittings, Inches ½" ¾" 1" 1¼" 1½" 2" 2½" 3" 4" 5" 6" 8" 10" 90 Ell 1.5 2.0 2.7 3.5 4.3 5.5 6.5 8.0 10.0 14.0 15 20 25 45 Ell 0.8 1.0 1.3 1.7 2.0 2.5 3.0 3.8 5.0 6.3 7.1 9.4 12 Long Sweep Ell 1.0 1.4 1.7 2.3 2.7 3.5 4.2 5.2 7.0 9.0 11.0 14.0 Close Return Bend 3.6 5.0 6.0 8.3 10.0 13.0 15.0 18.0 24.0 31.0 37.0 39.0 Tee-Straight Run 1 2 2 3 3 4 5 Tee-Side Inlet or Outlet or Pitless Adapter 3.3 4.5 5.7 7.6 9.0 12.0 14.0 17.0 22.0 27.0 31.0 40.0 Ball or Globe Valve Open 17.0 22.0 27.0 36.0 43.0 55.0 67.0 82.0 110.0 140.0 160.0 220.0 Angle Valve Open 8.4 12.0 15.0 18.0 22.0 28.0 33.0 42.0 58.0 70.0 83.0 110.0 Gate Valve-Fully Open 0.4 0.5 0.6 0.8 1.0 1.2 1.4 1.7 2.3 2.9 3.5 4.5 Check Valve (Swing) 4 5 7 9 11 13 16 20 26 33 39 52 65 In Line Check Valve (Spring) 4 6 8 12 14 19 23 32 43 58 or Foot Valve Page 4 3/1/2009

IT T GOULDS PUMPS Residential Water Systems APPLICATIONS Submersible water pumps designed for pumping out of reservoirs and storage tanks: Homes and farms Mobile home parks and motels Schools and hospitals Municipal applications Industrial applications Commercial applications SPECIFICATIONS Pump: 1 1 4" NPT discharge and open suction. Maximum suspended solids 1 8". Capacities: to 35 U.S. GPM (7.9 m 3 /h). Total heads: to 240 feet TDH (70 m). Temperature: 104ºF (40ºC) continuous 140ºF (60ºC) intermittent. Maximum submergence: to 65 feet (20 m). Continuous duty rated, non-overloading motor. Motor: Single phase: 3450 RPM, 115 and 230 V, 60 Hz. Three phase: 3450 RPM, 230 V, 60 Hz. Non-overloading. Class F insulation. Thermal overload protection: built-in with automatic reset on single phase. Three phase models require external overloads in panel. Power cord: All 30' long. Single phase 16/3, with 115 V or 230 V plug Three phase 16/4 STO, bare leads NOTE: See accessory section for separate control panels. METERS FEET 1SC51E- C 1 HP 60 200 1SC51D -B TOTAL DYNAMIC HEAD 40 150 100 3 /4 HP 1SC51C -A 1 /2 HP 1SC51E-H 1SC51D -G 20 1SC51C -F 1 H P 50 3/4 H P 1/2 H P 0 0 0 5 10 15 20 25 30 35 U.S. GPM 0 1 2 3 4 5 6 7 8 m 3 /hr CAP ACITY Page 5 3/1/2009