Automated Perimeter PTS 910, 910 BY

Similar documents
OCTOPUS 300 Perimetry you can trust

FINANCIAL DISCLOSURE. Visual Field Interpretation VISUAL FIELD INTERPRETATION IN GLAUCOMA

LIVING WITH GLAUCOMA Volume 29, Number 1

Understanding Visual Fields, Part III; Which Field Should Be Performed?

Journal of Ophthalmic Medical Technology

SOCT Copernicus HR Specification

OCTOPUS 600 See the new pulse in perimetry

Tobii Technology AB. Accuracy and precision Test report. X2-60 fw Date: Methodology/Software version: 2.1.7

Visual Field Analyzers from Carl Zeiss. Expanding your field of vision

CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras. Designed for the highest possible image quality. See the smallest details, don t miss pathology.

Video-Based Eye Tracking

HRK-7000 / HRK-7000A Auto Ref-Keratometer

Tobii AB. Accuracy and precision Test report. Tobii Pro X3-120 fw Date: Methodology/Software version: 2.1.7*

PRODUCT SHEET.

Eye-tracking. Benjamin Noël

SLIT LAMP BQ 900 Sophisticated microscopy

Fundus Photograph Reading Center

ROI (Return on Investment) for EMR (Electronic Medical Record) Systems

A Guided User Experience Using Subtle Gaze Direction

Designing eye tracking experiments to measure human behavior

LOCSU Enhanced Services

Phoroptor VRx Digital Refraction System

2WIN Binocular Mobile Refractometer and Vision Analyzer

ASSESSMENT OF READING VISION IN LOW VISION PATIENTS

How To Use Bodescan For 3D Imaging Of The Human Body

Product Range Overview

WE ARE in a time of explosive growth

LOUPES AND HEADLIGHTS HEADLIGHTS. HEINE Headlights. Type of Light LED LED F.O. Light Intensity (at 250 mm working distance)

D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

How To Use Netbiter

EMR-9 Quick Start Guide (00175)D 1

SUPERIOR EYE TRACKING TECHNOLOGY. Totally Free Head Motion Unmatched Accuracy State-Of-The-Art Analysis Software.

microscope OP-Dent-5

// ipq-view Digital web viewing for your quality assurance. Be inspired. Move forward.

NEW. EVEN MORE data acquisition and test stand automation

Professor, D.Sc. (Tech.) Eugene Kovshov MSTU «STANKIN», Moscow, Russia

11/11/2015. Glaucoma: Diagnosis and Treatment. Financial disclosures. Glaucoma: the problem. Joshua J. Ney, M.D. No disclosures to report

Smart Refractor RT-3100

New XUY roller sensors

New development of automation for agricultural machinery

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

Glaucoma - Visual Fields

7 MEGAPIXEL 180 DEGREE IP VIDEO CAMERA

Ophthalmic diagnostic products / 2015 Catalogue

Machine Tool Inspection & Analyzer solutions

Benchtop Computer Monitor Generator

Help maintain homeostasis by capturing stimuli from the external environment and relaying them to the brain for processing.

22 (21.5 viewable), 16:9 FHD LED monitor with SuperClear VA technology and HDMI input. VA2265Sh

ABrand New Refraction Meas urement Instrument

Visual Field Testing

D/N VANDAL RES. VARI-FOCAL DOME CAMERA

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Powerful advances in whole-field electrophysiology measurements

CORTICAL VISUAL IMPAIRMENT

Comparison of Retinal Image Quality between SBK and PRK. Allen Boghossian, D.O. Durrie Vision Overland Park, KS

Digital input modules

GAZETRACKERrM: SOFTWARE DESIGNED TO FACILITATE EYE MOVEMENT ANALYSIS

Initial clinical experience with the FS200 Femto and EX500 excimer

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Application Report: Running µshape TM on a VF-20 Interferometer

Rest ECG

Newron Efficient building management

Teaching with PowerPoint

Vmax Vyntus SPIRO. Advance your lung function testing experience

3D SCANNING SOLUTION FOR PIPELINE INTEGRIT Y ASSESSMENT!

VG2435Sm :10 Ergonomic Multimedia Display. Overview. See More, Work More with a 16:10 Aspect Ratio Display

Radiant Temperature Sensor TY7321

Chlorophyll Content Meter. CCM-200 plus

Grasshopper3 U3. Point Grey Research Inc Riverside Way Richmond, BC Canada V6W 1K7 T (604)

Network Documentation Checklist

MODERN CLINICAL OPTOMETRY BILLING & CODING THE MEDICAL EYE EXAMINATION. Definitions of Eye Examinations. Federal Government Definition

Glaucoma. Quick reference guide. Issue date: April Diagnosis and management of chronic open angle glaucoma and ocular hypertension

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

22 (21.5 viewable), 16:9 FHD LED multimedia monitor with SuperClear VA technology. VA2265Sm-3

MINIMAT-EC-Servo Screwdriver Spindles

LASER MARKING SYSTEMS

ADU 5. Automatic Distillation Unit

Smart Home Security Camera. No cords. No wires. No worries. Features. Motion Alerts Receive push notifications and s if anything moves

Enhanced Reporting Software Monitor USER MANUAL

Eye Tracking Instructions

Senses 3. The optics of the eye Accommodation of the eye Ammetropias The eyeground Visual field

Quality Assured. NEWAGE MT90 Series Microhardness Traverse Testing System. Newage Hardness Testing

Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated testing of square and round bars

The Action Potential Graphics are used with permission of: adam.com ( Benjamin Cummings Publishing Co (

MInIMAT-ec. flexible data recording highly accurate

LLX 200. Download and data processing software

Typical TIG-plasma solutions

EMG Biofeedback Device

Advancements in Close-Range Photogrammetry for Crime Scene Reconstruction

Siemens AG Mobility Division Nonnendammallee Berlin Germany

How To Use Printroom Manager

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Series 6000 Torque measured metal bellow coupling

System Wiring Design Guide

Rodenstock Photo Optics

Transcription:

PTS 910, 910 BY

Automated Perimeter PTS 910, 910 BY Automated Perimeter PTS 910, 910 BY is a modern diagnostic instrument for precise and fast testing field of vision using static stimuli. Broad range of test strategies enables a precise examination as well as to conduct a fast screening test. Testing of drivers is provided thanks to Binocular Driving Test with 160 degrees bitemporal field. Implemented BSV (Binocular Single Vision) strategy allows examination of diplopy areas. The device also provides examination by means of flickering stimuli for CFF (Critical Fusion Frequency) measurement purposes. Blue on Yellow (SWAP) strategy identifies early glaucomatous visual field defect before they could be detected using standard perimetry. It also helps to detect ocular hypertensives and neurological diseases. Test result is presented as easy-to-interpret graphic charts, referred to the age norm and patient s hill of vision. The printout contains additional information useful for interpretation, such as Mean Defect (MD), Pattern Defect (PD), Bebie Curve, Hill of Vision and Defects Progress Analysis. Examination reliability can be estimated on the basis of false negative and false positive tests. Built-in digital camera provides eye tracking, eye-detection, pupil position detection and automatic continous fixation control during examination. With electrically controlled chinrest you can precisely and easily set a proper patient position. PTS 910 BY Software Features: Multilingual user interface 13 languages available Test result analysis: Age Norm Deviation, Defect Progress Analysis, Results Comparison, Hill of Vision Deviation Age-related normative database Re-testing of selected points 3D results visualization Examination results comparison analysis Export/import of examination results Transferring examination between patients Networking User friendly ergonomic interface Multimedia storage database backup EMR (Electronic Medical Record) integration Saving printout as a graphical file Sound effects

Test Field Window Results Comparison Window 3D Visualization Window Examination Window Results Review Window Main Window & Setup Window

Patient data PRINTOUTS Examination data Absolute level map in decibel scale HOV deviation map in decibel scale Statistics Standard printout Absolute level map in dot scale Age norm deviation map in doc scale Bebie Curve graph Automated Perimeter PTS 910, 910 BY Comparison printout Alternative printout BDT printout

PTS 910, 910 BY Technical Data Number of test points Tested field range Perimetry technique Stimulus size 168 ( PTS 910 ) 168+120 ( PTS 910 BY ) 100 (160 for driving test) Static Goldmann Size III Automated Perimeter PTS 910, 910 BY Stimulus source Stimulus intensity Fixation control Patient response time Background illumination Test fields Strategies LED 565 nm ( PTS 910 ) LED 565 nm, LED 440 nm ( PTS 910 BY ) from 0,03 asb to 1000 asb (in 3 db steps) Gaze tracking, Video eye monitor, Heijl/Krakau blind spot monitor 0,1 to 7,5 s 10 asb white color ( PTS 910 ) 10 asb white color, 314 asb yellow color ( PTS 910 BY ) Central 30 Full 50 Peripheral 30-50 Macula 10 Glaucoma 22 /50 Extended 50 nasal, 80 temporal Fast 30 User defined, up to 50 Binocular Driving Test, 160 bitemporal, 100 vertical Threshold, Fast threshold, Screening, 3-zone, Neurological, BSV (Binocular Single Vision), Spatial sensitivity, Flicker (Critical Fusion Frequency measurement), BDT (Binocular Driving Test), Blue on Yellow (SWAP, PTS 910 BY) Result maps Age Norm Deviation, Hill of Vision Deviation, Defect Probability Graph, Defect Progress Analysis, Results Comparison, Bebie Curve, Pupil Movement Graph, 3D Visualization of Patients HOV Interface Dimensions Operating Voltage Additional features USB 2.0 670 x 550 x 400 HxWxD [mm] 100-250V 50/60Hz Eye monitoring by built-in video camera. Advance auto-detection of eye position. Automatic pupil diameter measurement. Electrical chinrest adjustment. Patient s adaptive pacing. Printout with color maps, standard style printout or alternative (Humphrey-like) style printout. Network capabilities (remote database, networked review stations). Ergonomic design provides comfortable position during examination. A special ventilation system keeps fresh air throughout examination.

OPTOPOL Technology S.A. ul. Żabia 42 42-400 Zawiercie, Poland Tel./Fax: +48 32 670 91 73 info@optopol.com.pl ver. PTS 910, 910 BY 01-2012 CENV www.optopol.com Canon Europa N.V. Medical System Division Bovenkerkerweg 59-61 1185 XB Amstelveen The Netherlands Phone: +31 (0) 20 545 89 26 Fax: +31 (0) 20 545 82 20 Local Distributor: