H15 Series BASO 100% Shutoff Automatic Pilot Valve

Similar documents
G670 Intermittent Pilot Ignition Controls

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

G234X-55 Conventional Gas Boiler

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

P70, P72, and P170 Series Controls for Dual Pressure Applications

Pressure Switch for gas and air

Commercial & Industrial Propane Regulators and Meters

Instantaneous gas water heater

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

PLUMBING RE-SUBMITTAL

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Commercial Gas Water Heaters

V47 Series Temperature Actuated Modulating Water Valves

Commercial Gas Cooking Thermostats

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

NAVIEN AMERICA INC FITCH AVENUE

Commercial Gas Water Heaters

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

Explosion-Proof Electric Unit Heaters

SIZING AND CAPACITIES OF GAS PIPING

OBSOLETE. VS8420 Millivolt Gas Valve

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

Commercial Gas Water Heater

Commercial Gas Furnace Upflow

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

orlando OWNER S MANUAL

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

San josé OWNER S MANUAL

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

MODEL LP 225LP2 225LP4 Safety Relief Valves

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl.

SIOUX HYBRID WATER HEATER

For over 40 years, the leader in. nitrous oxide. equipment technology.

289 Series Spring-Loaded Relief Valves

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

300 Series PA Pump and Cooler Assemblies

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING

Technical Specification. Generating Set with Waukesha engine burning natural gas

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Cooling Capacity CFM in. w.c. (125 Pa)

SIZING AND CAPACITIES OF GAS PIPING

Your safety and the safety of others are very important.

Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller

Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION

Incorrect use or failure of pressure regulators

A99B Series Temperature Sensors

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

E-gas Instant Gas Water Heaters

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

V46 Pressure-Actuated Water-Regulating Valve

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

P66 Series Electronic Fan Speed Controls

INSTALLATION MANUAL GAS COOKTOP. Please read this guide thoroughly before installation. P/No.: MFL

CST29A Adapter Block for Carlyle Compressors

UDSA - UDSBD unit heater

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

Installation. Professional Built-in Gas Rangetops VGRT736, CVGRT736, VGRT748, CVGRT748

Ingersoll Rand. Heat-Of-Compression Air Dryers

37E73A-903 & 906 INTELLI-VENT

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Light Duty Commercial Electric Water Heater

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

Commercial Gas Water Heaters

Commercial Hot Water. Make a difference...

PREPIPED LIQUID FUEL MANIFOLDS PLPM

Gas Valves. Thermocouples. Pilots. Thermopiles. Water Heating WH/HVAC PRODUCT INFORMATION

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

HEAVY DUTY STORAGE GAS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Electric & Gas Water Heaters

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

VSO MAX HP High Flow Proportional Valve

:2009 HELLENIC CHNICAL SPECIFICATION ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common ICS: 93.

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

Electric Water Heater

Gas Instantaneous Water Heater

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

EFFECTIVE OCTOBER Atwood Furnaces. and Digital Thermostats

NITROX // safer diving

SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER SHC 2.5 SHC 4. English. English

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Churrasco/Grill Manual Models: 2ft, 3ft, 4ft, 5ft & 6ft (with or without motor driven spits)

Transcription:

Product Bulletin Issue Date April 22, 2003 H15 Series BASO 100% Shutoff Automatic Pilot Valve The H15 Series pilot valves provide safe lighting and complete shutoff of pilot and main burner gas on a variety of domestic and commercial gas burning equipment. Applications include commercial cooking equipment, room heaters, wall heaters, unit heaters, central heating equipment, crop dryers, dishwashing machines, industrial ovens, and degreasing equipment. In addition to U.S. and Canadian certifications, the H15 models without a rotor B valve are CE Certified. Figure 1: H15 Automatic Pilot Valve Compact Design Safe Lighting Reliable Easy Operation Features and Benefits Permits installation in dimensionally restricted applications Allows gas flow only to the pilot burner during lighting Proven by thousands of units in service Provides simple lighting with use of large reset button Approved Worldwide (Models without Rotor B Valve Only) Broadens applications to include global markets 2003 Johnson Controls, Inc. 1 Code. LIT-4350010 www.johnsoncontrols.com

Application The H15 series automatic pilot valves provide safe lighting and complete shutoff of pilot and main burner gas. They are designed for standing pilot applications and can be used with natural gas, Liquefied Petroleum (LP) gas, or LP gas-air mixtures at pressures up to 35 mbar (0.5 psi). Models without a rotor B valve are suitable for operation over a temperature range of -34 to 80 C (-30 to 175 F). Models with a rotor B valve are suitable for operation over a temperature range of 0 to 80 C (32 to 175 F). The H15_B and H15_R models are suitable for operation over a temperature range of -29 to 150 C (-20 to 300 F). The use of single function components provides maximum flexibility in manifold makeup. By combining the H15 pilot valve with other single function components (pressure regulator, automatic gas valve, manual valve), you can meet the exact requirements of a wide variety of applications. Description H15 valves are 100% shutoff devices with compact, cast aluminum valve bodies. A rotor B valve is provided as an option for manual adjustment of the pilot flame (see Figure 2). The flow interruption feature allows gas to flow only to the pilot during the lighting operation. Mounting You may mount the H15 valves in any convenient position. Shutoff Valve Rotor B Valve Knob Reset Button X X indicates possible locations for other controls. 72.6 mm (3 in.) Sediment Trap X Pilot Burner Gas Line Thermocouple Lead Figure 2: Typical Installation Showing Rotor B Valve 2 H15 Series BASO 100% Shutoff Automatic Pilot Valve Product Bulletin

Dimensions C B Top View A Side View Figure 3: Internal Pilot Gas Valve Dimensions Table 1: Internal Pilot Gas Valve Dimensions Product A Maximum Length B Maximum Width C Maximum Height Number mm in. mm in. mm in. H15AA 74 2.90 46 1.81 94 3.69 H15CA 86 3.40 49 1.93 100 3.93 H15CB 86 3.40 49 1.93 100 3.93 H15DA 86 3.40 49 1.93 100 3.93 H15DB 86 3.40 49 1.93 100 3.93 H15FA 89 3.50 68 2.68 117 4.62 B C IN OUT Top View A Side View Figure 4: Internal Pilot Gas Valve with Rotor B Valve Dimensions Table 2: Internal Pilot Gas Valve with Rotor B Valve Dimensions Product A Maximum Length B Maximum Width C Maximum Height Number mm in. mm in. mm in. H15CH 844 3.310 66 2.59 97 3.819 H15DH 89 3.50 76 3.00 1170 4.62 H15 Series BASO 100% Shutoff Automatic Pilot Valve Product Bulletin 3

C B Top View A Side View Figure 5: External Pilot Gas Valve Dimensions Table 3: External Pilot Gas Valve Dimensions Product A Maximum Length B Maximum Width C Maximum Height Number mm in. mm in. mm in. H15AR 74 2.90 46 1.81 94 3.69 H15CQ 86 3.40 49 1.93 100 3.93 H15DQ 86 3.40 49 1.93 100 3.93 H15EQ 65 2.56 74 3.00 105 4.12 H15FQ 89 3.50 76 3.00 117 4.62 H15HQ 65 2.56 66 2.59 977 3.81 H15HR 65 2.56 66 2.59 97 3.81 4 H15 Series BASO 100% Shutoff Automatic Pilot Valve Product Bulletin

Flow Capacity 3/8 x 3/8 in. and 7/16 x 7/16 cc 1/2 x 1/2 in. 3/4 x 3/4 in (H15D_) 3/4 x 3/4 in (H15E_) 1 x 1 in. 40 30 20 16.0 12.0 8.0 6.0 Pressure Drop mbar 10 7 4.0 2.8 Pressure Drop in. W.C. 5 4 2.0 1.6 3 2 1.0 0.8 1 Air (specific gravity = 1.0) 1 2 3 4 5 6 8 10 20 30 40 50 0.4 m 3 /h Natural Gas (specific gravity = 0.64) 1.5 2 3 4 6 10 20 40 60 50 100 200 300 500 1000 2000 m 3 /h cf/h LP - Propane (specific gravity = 1.53) 1 2 3 4 6 10 20 40 40 50 100 200 300 500 1000 2000 Capacity Figure 6: Maximum Flow Capacity m 3 /h cf/h H15 Series BASO 100% Shutoff Automatic Pilot Valve Product Bulletin 5

Ordering Information H 1 5 - Customer-specific Requirements Letter *A= *B= H= *Q= *R= Rotor B Valve Yes Power Unit Standard High Temperature Standard Standard High Temperature Letter A= C= D= E= F= H= R= Capacity kw Btu/hr 48 94 118 158 179 50 50 163,000 322,000 402,000 540,000 610,000 172,000 172,000 Inlet/Outlet 3/8 x 3/8 in. NPT 1/2 x 1/2 in. NPT 3/4 x 3/4 in. NPT 3/4 x 3/4 in. NPT 1 x 1 in. NPT 3/8 x 3/8 in. NPT 7/16 x 7/16 cc *Indicates CE Certified. The presence of a particular construction in this information does not guarantee its availability. Consult Johnson Controls for available constructions. Figure 7: Ordering Matrix 6 H15 Series BASO 100% Shutoff Automatic Pilot Valve Product Bulletin

Technical Specifications Product Maximum Operating Pressure Recommended Thermocouple Lead Lengths Permissible Ambient (Surface) Temperature Inlet and Outlet Body Connections H15 Series BASO 100% Shutoff Automatic Pilot Valve 35 mbar (0.5 psi) K15: 305 to 1,220 mm (12 to 48 in.) K16: 305 to 1,830 mm (12 to 72 in.) K19: 457 to 1,830 mm (18 to 72 in.) Valve Torsion Group Group 2 (EN 125) Gas Valve Family Types of Gas Packaging Bulk Pack Quantity Bulk Pack Weight Agency Listing Specification Standards -34 to 80 C (-30 to 175 F) models without rotor B valve 0 to 80 C (32 to 175 F) models with rotor B valve -29 to 150 C (-20 to 300 F) H15_B and H15_R models only 3/8, 1/2, 3/4, or 1 in. NPT and 7/16 cc Class B Natural, Liquefied Petroleum (LP), and LP gas-air mixtures Bulk pack supplied to original equipment manufacturer (individual pack optional) 20, 30, 32, and 40 (depending on valve size) 11 to 19 kg (24 to 42 lb) CSA (AGA/CGA) Certificate Number 176835-1074130 Australian Gas Association Certificate Number 4236 EN/EC Type Examination Certificate Number E3735 (models without rotor B valve only) UL File Number MH2926 (H15CA, CH, and DA models only) ANSI Z21.20-1997 ANSI Z21.20a-1998 ANSI Z21.21-2000 ANSI Z21-78-1997, CGA 6.20-M97 ANSI Z21.78a-1998, CGA 6.20a-M98 ANSI Z21.78b-1999, CGA 2.20b-M99 EN 125 UL Standard 372 The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Refer to the H15 Series BASO 100% Shutoff, Automatic Pilot Valve Installation Instructions (Part. 24-8711-390) for necessary information on the installation, use, and servicing of this product. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 Published in U.S.A. www.johnsoncontrols.com H15 Series BASO 100% Shutoff Automatic Pilot Valve Product Bulletin 7