SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

STRATO LED Drivers 70W, Single output

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

Challenges to Ensure Safety of Electronic Equipment

CANADIAN STANDARDS ASSOCIATION OPERATING AS CSA GROUP 178 REXDALE BOULEVARD TORONTO, ONTARIO M9W 1R3 CANADA

ANSI Watthour Meter Testing & Certification Programs

TEST REPORT EN (1997) +A1 (2001)

Three-phase monitoring relay CM-PFE

Huawei NE5000E 400Gbps Flexible Line Processing Unit

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Test Report #: Date: April 8, 2005

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Annex of the certificate (Page 1/18) Accreditation Scope

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Waveguide Access Point WGA631. Product Guide

Guidance for upgrading to GB (IEC : 2005, MOD)

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RM4TG20 three-phase network control relay RM4-T - range V

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Analog signal converters CC-E I/I Current / current isolators

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electrical Safety and Another Regulation Amendment Regulation (No. 1) 2008

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

The Safety of Personal Hygiene and Beauty Therapy Equipment Used in Commercial Settings

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

IEC and CISPR Standards

Dual Chamber Temporary External Pacemaker

Cisco TelePresence MCU 4500 Series safety and compliance information

Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling

PUBLIC AUTHORITY FOR INDUSTRY

Cisco ASR 9001-S Router

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Power Supplies 3. SDN-P DIN Rail Series

Handheld portable appliance testers

EC-Declaration of Conformity Annex

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

AXIS T81B22 DC 30W Midspan

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Argentina. Certification Guidelines. For. Electric and Electronic Products

Patient Transport. with the Automated Impella Controller

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Technical Article. EMC filters for medical devices

Espotel Test Laboratory Services. November 20, 2014

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Cisco Nexus 7000 Series Power Supply Modules

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

7.5 Watt AC-DC Switch Power Supply

CERTIFICATE OF CONFORMITY

15 Series - Electronic step relay and dimmer. Features SERIE

Nya och reviderade standarder 2014

INTERNATIONAL STANDARD

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Operating Manual UWAPS-TINY Series

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

CSA GROUP 8501 EAST PLEASANT VALLEY ROAD CLEVELAND, OHIO 44131

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Power Meter Series 700

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

ST Series POWER SUPPLIES USER INSTRUCTIONS

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

40 Years of experience in EMC testing

How To Use A Power Supply Unit (Upu)

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Failure code manual. content

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Your energy costs. A room-by-room guide. P.O. Box San Diego, CA Connect at sdge.com

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SINGAPORE CONSUMER PROTECTION (SAFETY REQUIREMENTS) REGISTRATION SCHEME

Lithium Ion Battery Specifications

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

High Frequency Power Quality

HOUSING QUALITY STANDARDS (HQS)

CPAP System This CPAP system is intended for the treatment of adult obstructive Sleep Apnea only. NOTE: The C-Flex mark is used under license.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Section B: Electricity

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TUV RHEINLAND OF NORTH AMERICA INC. 12 Commerce Road Newtown, CT 06470 Mr. Bruce Fagley: 203 426 0888 x119 Email: bfagley@us.tuv.com www.tuv.com ELECTRICAL Valid to: August 31, 2018 Certificate Number: 3331.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the laboratory s compliance with A2LA s ENERGY STAR Accreditation Program requirements 1 accreditation is granted to this laboratory to perform the following energy efficiency, product safety, and electromagnetic compatibility (EMC) tests: Test Description: Test Method(s) 2 : Emissions 3 Radiated and Conducted (up to 40 GHz) 47 CFR, FCC Part 15B (using ANSI C63.4-2014); 47 CFR, FCC Part 18 (using FCC MP-5, 1986); ICES-003, Issue 6; IEC/CISPR 11; EN 55011; AS/NZS CISPR 11; AS/NZS CISPR 11:2004; IEC/CISPR 14-1; AS/NZS CISPR 14.1:2010; EN 55014-1; EN 55022; IEC/CISPR 22; AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; EN 55032; CISPR 32; KN 32; CNS 13438 (up to 6 GHz); CNS 13783-1; VCCI V-3 (up to 6 GHz); TCVN 7189:2009 (CISPR 22:2006); KN 11; KN 14-1; KN14-2; KN 22 Current Harmonics IEC 61000-3-2; EN 61000-3-2; EN 61000-3-12 Flicker and Fluctuations IEC 61000-3-3; EN 61000-3-3; EN 61000-3-11 Immunity 3 Electrostatic Discharge IEC 61000-4-2; EN 61000-4-2 Radiated (up to 6 GHz) Electrical Fast Transient / Burst IEC 61000-4-3; EN 61000-4-3 IEC 61000-4-4; EN 61000-4-4 (A2LA Cert. No. 3331.01) Revised 11/30/2016 Page 1 of 6

Test Description: Test Method(s) 2 : Immunity 3 (cont.) Surge IEC 61000-4-5; EN 61000-4-5 Conducted IEC 61000-4-6; EN 61000-4-6 Power Frequency Magnetic Field Voltage Dips, Short Interrupts, and Voltage Variations Conducted, Common Mode Disturbances (0 to 150) KHz IEC 61000-4-8; EN 61000-4-8 IEC 61000-4-11; EN 61000-4-11 IEC 61000-4-16; EN 61000-4-16 Generic / Product Specific KN 24; KN 35; EMC Standards 3,4 EN ISO 14982; EN 50121-3-1; EN 50121-3-2; EN 50121-1; EN 50121-2; EN 50121-4; EN 50270; EN 50370-1; EN 55103-1; EN 55103-2; EN/IEC 60601-1-2; KN 60601-1-2; EN 60669-2-1; EN 61000-6-4; KN 61000-6-4; EN 61000-6-3; KN 61000-6-3; EN 61000-6-2; KN 61000-6-2; EN 61000-6-1; KN 61000-6-1; EN 61326-2-2; EN 61326-2-1; EN 61326-1; EN 61326-2-4; EN 61326-2-5; EN/IEC 61326-2-3; EN/IEC 61326-2-6; EN 62040-2; CISPR 12; EN 55013; EN 12016; EN 50130-4; EN 60945; KN 60945; IEC 60533; KN 60533; EN 50428; EN 60947-2; EN 61547; EN 55014-2; EN 55020; EN 55024; EN 12895; ISO 13766; EN 61204-3; ETSI EN 301 489-1; ETSI EN 301 489-3; EN 1155; EN 62233; IDA TS EMC (Singapore); EN 61800-3, KN 61800-3 (only clauses 5.3, 6.1); EN 50293; EN 16361 (only clauses 4.13 & 5.13) Testing for the above Generic / Product Specific EMC standards is via the Emissions and Immunity test methods. (A2LA Cert. No. 3331.01) Revised 11/30/2016 Page 2 of 6

Test Description: Test Method(s) 2 : Product Safety Household EN/IEC/CSA/UL 60335-1: General Requirements; EN/IEC/CSA 60335-2-2: Vacuum Cleaners and Water Suction Cleaning; EN/IEC/CSA/UL 60335-2-8: Shavers, Hair Clippers; EN/IEC/CSA 60335-2-9: Grills, Toasters and Similar; EN/IEC/CSA 60335-2-10: Floor Treatment and Wet Scrubbing Machines; EN/IEC/CSA 60335-2-14: Kitchen Appliances; EN/IEC/CSA 60335-2-15: Appliances for Heating Liquids; EN/IEC/CSA 60335-2-23: Appliances for Skin or Hair Care; EN/IEC/CSA 60335-2-28: Sewing Machines; EN/IEC/CSA 60335-2-29: Battery Chargers; EN/IEC/CSA 60335-2-30: Room Heaters; EN/IEC/CSA 60335-2-32: Massage Appliances; EN/IEC/CSA 60335-2-41: Pumps; EN/IEC/CSA 60335-2-42: Commercial Forced Convection Ovens, Steam Cookers and Steam-Convection Ovens; EN/IEC/CSA 60335-2-43: Clothes Dryers and Towel Rails; EN/IEC/CSA 60335-2-44: Ironers; EN/IEC/CSA 60335-2-45: Portable Heating Tools and Similar Equipment; EN/IEC/CSA 60335-2-52: Oral Hygiene Appliances; EN/IEC/CSA 60335-2-60: Whirlpool Baths; EN/IEC/CSA 60335-2-64: Commercial Electric Kitchen Machines; EN/IEC/CSA 60335-2-65: Air Cleaning Appliances; EN/IEC/CSA 60335-2-75: Commercial Dispensing Appliances and Vending; EN/IEC/CSA 60335-2-80: Fans; EN/IEC/CSA 60335-2-81: Foot Warmers and Heating Mats; EN/IEC/CSA 60335-2-82: Amusement Machines and Personal Service Machines; EN/IEC/CSA 60335-2-84: Toilets; EN/IEC/CSA 60335-2-95: Drives for Vertically Moving Garage Doors; EN/IEC/CSA 60335-2-97: Drives for Rolling Shutters, Awnings, Blinds Information Technology EN/IEC/CSA/UL 60950-1; EN/IEC/CSA/UL 60950-21; EN/IEC/CSA/UL 60950-22; EN/IEC/CSA/UL 60950-23; EN/IEC 62040; IEC/UL 62368 Audio / Video EN/IEC/CSA/UL 60065 Lab, Test & Measurement IEC/EN/CSA/UL 61010-1; IEC/EN/CSA/UL 61010-2-10; IEC/EN 61010-2-081; IEC/EN 61010-2-101 (A2LA Cert. No. 3331.01) Revised 11/30/2016 Page 3 of 6

The below tests are performed using the above Product Safety standards - Input Current - Steady Force Test - Durability of Markings - Drop Test - Access to Live Parts - Stress Relief - Energy Hazards - Wall or Ceiling Mounted Equipment - Capacitance Discharge - Handles and Manual Controls - TNV Circuits, Limits, Connections, Voltages Generated Externally - Battery Overcharge / Discharge and Reverse Current Measurements - SELV Circuits - Spillage Tests - Telecommunication Network Separation and Protection - Protection Against Hazardous Moving Parts - Limited Current Circuits, Values - Thermal Requirements - Limited Power Sources - Temperature Rise - Resistances of Earthing Conductors - Resistance to Abnormal Heat - Component Failure and Abnormal Operation - Touch Current and Protective Conductor Current - Creepage Distances, Clearances - Electric Strength - Working Voltage - Humidity Conditioning - Thermal Cycling and Thermal Aging - Fluid Pressure and Leakage - Mechanical Strength - Voltage Surge / Impulse - Enclosed and Sealed Parts - Stability - Ionizing Radiation - Sound Pressure Level - Torque - Resistance to Fire - Power Supply Output / Transformer / Accessible Connector Overload Excluded Measurements: - Laser - Vibration - Photobiological - Oxygen Bomb - Cord Reel - Specially Protected Equipment (IP rated) (A2LA Cert. No. 3331.01) Revised 11/30/2016 Page 4 of 6

Test Description: Test Method(s) 2 : Energy Efficiency Verification Testing for Canada IEC/EN 62301; CAN/CSA C381.1-08; CAN/CSA C802.2 California Efficiency Commission (CEC) Efficiency Testing Product Family Guidelines: Consumer Audio & Video Large Battery Charger Systems Portable Electric Spas Supporting Test Method(s): IEC 62087:2002(E) Energy Efficiency Battery Charger System Test Procedure Version 2.2 dated November 12, 2008 CEC Appliance Efficiency Regulations Section 1604(g)(2) Power Supplies US EPA Test Method dated 08-11-2004 Small Battery Charger Systems 10 CFR 430.23(aa) - Appendix Y to Subpart B of Part 430, Uniform Test Method for Measuring the Energy Consumption of Battery Chargers Televisions 10 CFR Section 430.23(h) (Appendix H to Subpart B of Part 430) EPA ENERGY STAR Testing Product Family Supporting Test Methods(s): Guidelines: Computers ENERGY STAR Program Requirements for Computers Version 6.1; ENERGY STAR Test Method for Computers (August 2014) With reference to IEC 62301 (2011); IEC62623(2012); IEC 60107-1 (1997); EPRI Generalized Test Protocol for Calculating the Energy Efficiency of Internal AC-DC and DC-DC Power Supplies Enterprise Servers Imaging Equipment ENERGY STAR Program Requirements for Computer Servers Version 2.0; ENERGY STAR Test Method for Computer Servers (April 2013) With reference to IEC 62301 (2011); Standard Performance Evaluation Corporation (SPEC) most current Server Efficiency Rating Tool (SERT); EPRI Generalized Test Protocol for Calculating the Energy Efficiency of Internal AC-DC and DC-DC Power Supplies ENERGY STAR Program Requirements for Imaging Equipment Version 2.0; Test Method for Determining Imaging Equipment Energy Use (September 2014) With reference to IEC 62301 (2011) (A2LA Cert. No. 3331.01) Revised 11/30/2016 Page 5 of 6

1 A2LA provides accreditation to the U.S. EPA s Conditions and Criteria for Recognition of Laboratories for the ENERGY STAR Program by verifying an organization s compliance to A2LA document R222 - Specific Requirements - EPA ENERGY STAR Accreditation Program and to the related test methods listed above. Accreditation by A2LA does not infer Recognition by the EPA for ENERGY STAR testing. Please verify this organization s recognition status at the EPA s website, located at http://www.energystar.gov/index.cfm?fuseaction=recognized_bodies_list.show_rcb_search_form. 2 When the date, revision or edition of a test method standard is not identified on the scope of accreditation, the laboratory is required to be using the current version within one year of the date of publication, per part C., Section 1 of A2LA R101 - General Requirements - Accreditation of ISO-IEC 17025 Laboratories. 3 Field testing services are available for this test and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for this test. 4 For Product Family Standards listed on this scope of accreditation, the laboratory is found to be compliant with all test methods referenced within the Product Family Standard. As such, if outdated versions of the specific test methods are identified by the Product Family Standards listed on this scope of accreditation, it is not necessary to explicitly list the outdated versions of the specific test methods on the scope. In addition, the laboratory is capable of issuing accredited test reports to the outdated versions of the specific test methods although the outdated versions are not listed on this scope of accreditation. (A2LA Cert. No. 3331.01) Revised 11/30/2016 Page 6 of 6

Accredited Laboratory A2LA has accredited TUV RHEINLAND OF NORTH AMERICA INC. Newtown, CT for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the A2LA R222 - Specific Requirements - EPA ENERGY STAR Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 17 th day of November 2016. President and CEO For the Accreditation Council Certificate Number 3331.01 Valid to August 31, 2018 For the tests to which this accreditation applies, please refer to the laboratory s Electrical Scope of Accreditation.