Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data

Similar documents
HL Series - Commercial Heaters Tankless Water Heating Solutions

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

G234X-55 Conventional Gas Boiler

Centro-Matic Automatic Lubrication Systems System Controls

NAVIEN AMERICA INC FITCH AVENUE

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

FLASH TANK ECONOMIZER PRODUCT GUIDE

Instruction Sheet X Pump Block (XPB)

For Multi-Parameter Meters see mvx

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

MAC-120HE-01 Air-Cooled Chiller

In-Line Electronic Flow Switches

Better Boilers.

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

300 Series PA Pump and Cooler Assemblies

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Basic Nameplate Information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

CRN A-F-G-E-HQQE 3x400D 50 HZ

Sanitary Type Electronic Flow Switches

Electronic Flow Switches

USER S MANUAL HSC-24A

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Technical Specification. Generating Set with Waukesha engine burning natural gas

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Gas Water Heater

Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition

CGC s Hybrid System Loop Control

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Tempra / DHC-E. Simply the Best The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Commercial Semi-Instantaneous Water Heaters

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Model 1210C Battery Powered Pump Shown. Description

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TANKLESS DURABILITY Tankless Product Guide

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

SOLI TANKLESS PRODUCT GUIDE

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Technical data. Danfoss DHP-A

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

REGULATORS 175/153 Series

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

Aerona Air Source Heat Pumps

Explosion-Proof Electric Unit Heaters

F9MXE. Product Specifications

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Fossil fuel heating equipment

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

ELECTRIC CENTRAL HEATING FLOW BOILER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

High kw Electric Tankless Water Heater Troubleshooting Guide

PLUMBING SUBMITTAL

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Commercial Gas Water Heaters

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Multistage high-pressure multistage centrifugal pumps

Goulds Water Technology

Commercial Electric Water Heater

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

G9MXE. Product Specifications

Installation and maintenance instructions. Danfoss Vent

SECTION MORTUARY REFRIGERATORS

HVAC HANDBOOK HV AC LPH H B001

HP switch LP switch Discharge thermo Comp. Surface thermo

Commercial Boiler Systems and Controls

presents Hydraulic Separation Beyond Primary / Secondary Piping

Liquid Level Limit Switch liquiphant T FTL 20

Electric Flow Boiler

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Nirvana. Cycling Refrigerated Dryers

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

In-Line Air Separators

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5


Transcription:

Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas Snowmelt Panel, in conjunction with the snowmelt control, socket, and sensor, utilizes optics rather than continuity based on/ off sensors. This method of snowmelt detection allows for great efficiencies and set point controllability. The control on the panel measures slab temperature, as well as boiler loop temperature to ensure the return water going back to the boiler does not shock the boiler heat exchanger. The snowmelt system pump is piped independently from the boiler loop so that the only head loss that needs to be calculated in the system is the piping from the panel to the manifold, and the loops in the slab. This feature allows for higher flow rates and head losses if needed, which in turn expands the range of pumping ability for the system pump. Nominal Panel Output Qty Model # BTU Rating Boiler Pump System Pump Injection Pump Heat Exchanger Snow Melt Control T-SM-HBX-35 HX 35 UPS 6-99 UPS 6-15 UPS 15-58 LA14-5 HBX SNO-55 Technical Data Material: Backpan... Stainless Steel Optional Lockable Enclosure... Stainless Steel Piping... Copper Type L Mixing Device... Injection Pump Standards/Listings CSA C. No. 14-95 UL 598A ETL No. 337 Flow Capacity Rating of Balancing Valve... 1.76 m 3 /hr Max Ambient Temperature... 1 F (49 C) Max Water Temperature... F (93 C) Power Supply... 11V (AC) Max Current 6amp Page 1

Heat Exchanger Specifications PROJECT DATA SHEET Heat Load 35 BTU/h LMTD 61.9 deg. F Min. Oversizing % Hot Side Cold Side Fluid water glycol_(propylene)_5% Inlet Temperature 185. deg. F 69. deg. F Outlet Temperature 15. deg. F 139. deg. F Mass Flow 11.61 lb/h 571.1 lb/h Inlet Volume Flow.59 USGal/min 1.98 USGal/min Outlet Volume Flow.33 USGal/min 11.8 USGal/min Max. Pressure Drop 14.5 psi 14.5 psi HEAT EXCHANGER SELECTION Heat Exchanger Type LA14-5 # of Units Parallel 1. Heat Transfer Area 6.5 ft Fouling Factor.1 fthf/btu OHTC Clean 954. BTU/fthf OHTC Fouling 87.5 BTU/fthf Oversize 9.6 % Hot Side Cold Side Calculated Pressure Drop 6.8 psi.36 psi Heat Transfer NTU - - PHYSICAL PROPERTIES Hot Side Cold Side Fluid water glycol_(propylene)_5% Pressure 3. psig 3. psig Reference Temperature 167.5 deg. F 14. deg. F Density 6.961 lb/ft3 63.989 lb/ft3 Heat Capacity 1. BTU/lbF.876 BTU/lbF Thermal Conductivity.38 BTU/fthF.18 BTU/fthF Dynamic Viscosity.381 cp.79 cp Dimensions: mm (inches), NP = Number of Plates A B C D F K1 K K3 K4 194 (7.6) 8 (3.1) 15.4(6) 39.9(1.57) 1. +.3NP(.39+.9NP) 3/4" 3/4" 3/4" 3/4" Specifications and dimensional data shall be used as guidelines and may change without notice. For guaranteed performance, please verify selections with the manufacturer. Page

Panel Components 1 8 4 3 5 From Boiler 1 To Boiler 1 7 6 9 System Return 11 System Supply Part List 1 Stainless Steel Back Plate 7 Brazed Plate Heat Exchanger LA14-5 Lockable Stainless Steel Cover (Optional) 8 HBX Controls SNO-55 3 Tamas Control Box 9 1 1/4 Air Eliminator 4 Temperature Gauge 1 1 1/4 Balancing Valve 5 4V Transformer 11 System Pump UPS 6-15 6 Injection Pump UPS 15-58 1 Boiler Pump UPS 6-99 Page 3

Panel Dimensions 4.91 * 9.134 13.459 33.35 7.45 35.957 13.515 *Optional Lockable Enclosure Shown Page 4

Pump Specifications UPS 15-58 3 Speed Pump Ft 18 16 14 1 1 8 6 4 HI MED LOW Performance 4 6 GPM 8 1 1 8 7 Watts 6 5 HI MED LOW 4 3 4 6 8 1 1 GPM 3 o F Max fluid temp (closed system) 15 o F Max fluid temp (open system) 36 o F Min fluid temp 1 Bar Max system pressure Approvals ETL NSF Std 61 Annex G Page 5

Pump Specifications UPS 6-99FC/BFC SUPERBRUTE 3 5 HI MED Without Check Valve With Check Valve Head (ft.) 15 LOW 1 5 5 1 15 5 3 35 Flow (GPM) Flow range: Head range: Motors: Maximum fluid temperature: Min. fluid temperature: Maximum working pressure: - 34 U.S. GPM - 3 FEET Pole, Single Phase 3 F (11 C) 36 F ( C) 145 PSI B C A MODEL VOLTS AMPS WATTS HP CAPACITOR Spd. 3 1.8 197 1/6 mf/18v 115V Spd. 1.5 179 1/6 mf/18v Spd. 1 1.3 15 1/6 mf/18v Spd. 3.9 196 1/6 5mF/4V 3V Spd..8 179 1/6 5mF/4V Spd. 1.7 15 1/6 5mF/4V D F E Model Type A B C D E F Connection Type and Size Approximate Shipping Wt. (lbs) UPS6-99FC/BFC 6 1/ 6 4 7/8 3 1/ 3 7/16 3 5/3 GF 15/6 Flange - () 1/" Dia. Bolt Holes 1.3 Page 6

Pump Specifications UPS 6-15 F H [ft] 45 UPS 6-15 F, 6Hz Pumped liquid = Water Liquid temperature = 14 F Density = 61.35 lb/ft³ eta [%] 9 7 1/8" 5 7/8" 4 8 35 3 7 6 6 1/" 5 5 4 15 3 1 3 3/4" 5 5 1 15 5 3 35 4 45 P1 [W] Q [US gpm] 1 3 7/8" 3 1/8" 35 3 5 15 Description Value 1 5 Technical: Speed Number: 3 Max flow: 5 US gpm Head max: 45.3 ft Approvals on nameplate: ETL, CSA Page 7

HBX SNO-55 Specifications HBX Control Systems Inc Specification Part 1: SNO-55 Product 1. The Control must be capable of utilizing a multi-color backlight display.. The Hydronic Control must be a full microprocessor control with at least an 8-bit, 8MHz integrated microprocessor chip. 3. The Control must be capable of the following Input/Output Functions a. 1 x Demand Input/Dry contacts b. 1 x Boiler/BMS Output Relay c. 4 x Temperature Sensor Inputs: i. System ii. Return iii. Slab Sensor iv. Outdoor Air Temperature d. 3 x Output Relay (Pumps or Valve) e. 1 x Optical (digital) Snow sensor input 4. The Control must be capable of automatically calculating and resetting the system fluid target temperature based on the user defined system delta T for slab protection. 5. The Control must have the ability to program and control for Warm Weather Shut Down, and Cold Weather Shut Down. 6. The Control must be capable of operating a PMIp injection pump or a floating action valve for mixing purposes. 7. The Control/unit must operate using a three button user interface 8. The Control must also be capable of utilizing feedback from optical snow sensing technology with integrated slab temperature sensing. 9. The Control must have adjustable preset snow conditions to allow for snow and ice detector tuning. 1. The Control must have onboard testing capabilities to individually test each relay and to test control operations functionality. 11. The Control unit must be ETL approved. Part : Acceptable Products 1. HBX SNO-55 Control Page 8

HBX SNO-55 Specifications Part : Technical Data, Main Parts & Labels Inputs/Outputs: Side View Front View 66 mm 7.19 mm 3 x Thermistor Input (1K Ohm) 1 x Boiler/BMS Dry Contact (1 VAC, A) Output 3 x Relay Dry Contact (4VAC, 5A) Outputs 1 x Dry Contact Demand Input Sensor Input: 188 mm 1 x Optical Snow & Ice Detector / Slab Sensor Input 1 x Modulating Heater Output Power supply: 1 VAC, 15A (protected by resetable fuse) Supplied Parts: 1 x HBX 9-1K Ohm Thermistor, 1 lead wire 1 x HBX OUT-1 1K Ohm Outdoor Sensor Dimensions: Rear View 11 mm Top View 4.76 x 7.4 x.6 (11mm x 188mm x 66mm) ETL Listings: Meets CSA C. No. 4 Meets UL Standard 873 ETL Control No. 368143 167 mm Bottom View Storage: 1 mm 5 F to 14 F (1ºC to 4ºC) Terminal Labels: HBX SNO-55 Central Processing Unit 5 A 5 A 5 A A 14 15 16 17 18 19 1 1 3 4 5 6 7 8 9 1 11 1 13 1 SG PW TM S FD FD BL BL TM TM TM 1 3 4 5 1 1 1 1 1 3 C L N GR 1 1 SNO-11 Optical Sensor Relay 3 Demand Inputs Relay Boiler Contacts Relay 1 Sensor Inputs Supply Power 1 VAC Page 9