PTP-Global. Alarm Management An Introduction



Similar documents
White Paper. Why is Alarm Management Required in Modern Plants? What s Inside:

Alarm Management What, Why, Who and How?

process Preventing Unplanned Downtime through Alarm Management: The Five Most Important Alarm Management Techniques for Preventing Unplanned Downtime

Alarm Management Program: Implementation Experience in a Petrochemical Company

Setting a new standard in alarm management

Process Solutions. DynAMo Alarm & Operations Management. Solution Note

Delivering operations integrity through better plant safety, availability and compliance across your entire enterprise

Usability does the system meet user needs & operate within their capabilities;

Alarm Management. July 2012 / White paper. Make the most of your energy SM

Alarm Management Standards Are You Taking Them Seriously?

Alarm Philosophy Document Template. Prepared for: Customer Company Name

ALARM PERFORMANCE IMPROVEMENT DURING ABNORMAL SITUATIONS

ISA-SP18 - Alarm Systems Management and Design Guide

Safety & Automation System (SAS) - How the Safety and the Automation Systems finally come together as an HMI

A Guide to Effective Alarm Management

ALARM MANAGEMENT AND ISA-18 A JOURNEY, NOT A DESTINATION

Introduction. Chapter 1

Alarm Management Services

Features. Emerson Solutions for Abnormal Situations

Alarm Management. White Paper. October 2008

Wonderware Alarm Adviser Providing the Right Advice to Improve Operator Efficiency

Integrated Fire and Gas Solution - Improves Plant Safety and Business Performance

A Path Forward for DCS Alarm Management

DeltaV Analyze. Introduction. DeltaV Distributed Control System. Product Data Sheet

Principles for alarm system design. February 2001 YA-711

THE ALARM SYSTEM FROM THE OPERATOR`S PERSPECTIVE. C T Mattiasson. Scanraff AB, Sweden. Introduction

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Alarm Management Standards and Best Practices

Alarms are used in chemical processing plants to

Seion. A Statistical Method for Alarm System Optimisation. White Paper. Dr. Tim Butters. Data Assimilation & Numerical Analysis Specialist

KPI, OEE AND DOWNTIME ANALYTICS. An ICONICS Whitepaper

Alarm Services. Introduction. Benefits. Alarm System Status Awareness. Increased operator efficiency. Regulatory and standards compliance.

Practical Ideas for Effective Alarm Management

Safety Requirements Specification Guideline

Planning Your Safety Instrumented System

Management of Change: Addressing Today s Challenge on Documenting the Changes

The Role of Automation Systems in Management of Change

Control Room Management and Related Best Practices

ABB Consulting Alarm Management. ABB Group March 24, 2015 Slide 1

Fire and Gas Solutions. Improving Safety and Business Performance

Loop Scout. Loop and Alarm Performance Management Service

White Paper. Intuition Operations Monitoring: Latest Software for Improving Plant Performance, Reliability and Safety.

Operations Management Pro

Collaborative Production Management in the Process Industries: From KPIs to Workflows

Predictive Asset Maintenance

Software improves alarm management and KPI reporting at UK-based power station

Alarm Management By the Numbers

Achieving Effective Alarm System Performance: Results of ASM Consortium Benchmarking against the EEMUA Guide for Alarm Systems

SOFTWARE-IMPLEMENTED SAFETY LOGIC Angela E. Summers, Ph.D., P.E., President, SIS-TECH Solutions, LP

System 800xA Alarm Management Effective detection, notification, analysis and corrective action of abnormal situations

Alarm Rationalization

Printed in the United States of America by 360 Digital Books, Kalamazoo, MI

MANAGING THE RISKS OF CHANGE

Alarm Response Management

Expanding Uniformance. Driving Digital Intelligence through Unified Data, Analytics, and Visualization

> THE SEVEN GREATEST THREATS TO PROCESS PLANT > WHAT S INSIDE: SAFETY, AND HOW TO MANAGE THEM WHITE PAPER

MANAGING ASSETS WITH MODERN TOOLS AT WHITE BIRCH PAPER

Software Development Risk Assessment

Maximizing return on plant assets

Decision Support System for Alarm Rationalization using Risk Assessment Matrix

The Benefits of using Dynamic Simulation and Training Systems for expanding Operator Knowledge and Understanding

Basic Fundamentals Of Safety Instrumented Systems

Alain Nifenecker - General Electric Manager Controls Engineering

Introducing and Managing Process Safety Key Performance Indicators (KPIs)

Plant Wide Performance Monitor Bridges Resource Gap

How To Use Safety System Software (S3)

Managing the Process, Not the Alarms at ConocoPhillips

Master Class. Electrical and Instrumentation (E &I) Engineering for Oil and Gas Facilities

ITIL A guide to Event Management

Safety critical communication. Overview. Communication. Andy Brazier

Kepware Whitepaper. Enabling Big Data Benefits in Upstream Systems. Steve Sponseller, Business Director, Oil & Gas. Introduction

Office Business Applications (OBA) for Healthcare Organizations. Make better decisions using the tools you already know

Comparative Analysis of Free IT Monitoring Platforms. Review of SolarWinds, CA Technologies, and Nagios IT monitoring platforms

IntraVUE Diagnostics. Device Failure

Monitoring of Applications for Performance and Availability. RTView for APM for applications built using GlassFish

Alarm Management. Whitepaper August DeltaV Distributed Control System

Managing Successful Software Development Projects Mike Thibado 12/28/05

SPPA-D3000 Plant Monitor Technical Description

Emergency Preparedness Guidelines

CENTRALIZED CONTROL CENTERS FOR THE OIL & GAS INDUSTRY A detailed analysis on Business challenges and Technical adoption.

DeltaV SIS for Burner Management Systems

Security Solutions to Meet NERC-CIP Requirements. Kevin Staggs, Honeywell Process Solutions

AP1000 European 18. Human Factors Engineering Design Control Document

Fire Station IP Alerting System

BS 7 SIS Safety Information System Green Light for Your Production

Chapter 1: Health & Safety Management Systems (SMS) Leadership and Organisational Safety Culture

FLEET SAFETY INSAFE Safety Consultants Mark McDaniel - Bob Starkey

Asset management systems increase reliability and efficiency

Integrating Control and Safety with Secure System Segregation

Control System Asset Management

Client Onboarding Process Reengineering: Performance Management of Client Onboarding Programs

Improving. Summary. gathered from. research, and. Burnout of. Whitepaper

Best Practices in. Best IT Asset Management through Smart RFID-Enabled Software. Art Barton, Director of RFID Strategies, RFTrail

Transcription:

Alarm Management An Introduction

Presentation Contents 1. The Old and the New 2. Importance of Alarm Management & Historical Context 3. Guides, Standards and Regulations 4. Benefits & Design of Alarm Management 5. Alarm Issues

The Old Simple and clear alarms Alarm annunciators Hard wired alarms PTP-Global

The Scope of the Problem Operators typically monitor more than 5,000 devices Each device typically has 4 to 5 alarms configured on it Devices x alarms results in Operators having to manage 20,000 to 25,000 alarms The average Operator gets 1,200 alarms per day, approximately 1 per minute! Engineering Equipment & Materials Users Association (EEMUA) recommends no more than 6 alarms per hour PTP-Global

The Causes of the Problem Historically, alarms were expensive and difficult to add resulting in careful review before implementation Each had to be hardwired Limited space in control panels Today, hardware and software advances has made it possible to alarm most devices at minimal cost Large increase in the quantity of alarms Less review resulting in reduced quality

Fundamental ASM Problem

Why Grey Scale Graphics Directing operator s attention to the most critical information with the least possibility for confusion, slow response, or errors in detection or interpretation. addressing concerns with respect to individuals that might have color vision deficiencies reducing glare so ambient light levels are high enough to support both visual acuity for non-display tasks (e.g., reading paper copy) and also biological clock adjustments for the appropriate day or night shift PTP-Global

Basic principles of human sensation and perception To enhance situation awareness, techniques to enhance the salience of the associated display elements. An object is more salient than another object if it stands out or grabs one s attention. Important to emphasize abnormal states, off-normal conditions and dynamic data. If red means critical alarm state then it should not also mean a pump is off. The background display color in combination with the ambient light level of the control room can impact the probability of eye strain and fatigue as well as visual acuity. PTP-Global

Sources of Abnormal Events

Human Limitations

ASM Grey Scale

HMI Individual Graphic Migration PTP-Global Initial Process Graphic Enabling Scope Execution 1234 1234 1234 Migrated Statics Graphic. 1234 Workpack Execution 1234 1234 (Note: More than one Workpack will be required to complete dynamic element migration when elements from more than 1 Process System are present) 1234 Current MB300 dynamic elements 1234 1234 1234 1234 Stage 1 Stage 2 1234 Partially Migrated Dynamics Graphic 1234 1234 1234 1234 Stage N 1234 1234 1234 Migrated Process Graphic 15/07/2013 Rev 0.2 12 1234

The Causes of the Problem Alarms are continuously added Often after incident reviews Changes in process After de-bottlenecking projects Equipment changes and degrades Different vendors with different normal operating conditions Wear resulting in reduced efficiency Seasonal changes to process

Common Problem Alarm Types Standing No dynamic process logic Nuisance Alarms Frequent Poor Set value/s Possible control problem Redundant Equipment out of service Alarms still functional Improperly Prioritised EEMUA recommends process alarm priorities of: 80% low, 15% medium and 5% high PTP-Global

..and the New DCS systems installed Numerous free alarms Everything is turned on

Alarm Timeline

Why is Alarm Management Important? Accident investigations have identified that: inadequate alarm system performance contributed to a significant number of industrial accidents Three Mile Island - 1979 Piper Alpha - 1988 Milford Haven Refinery - 1994 Buncefield Oil Storage - 2005

Three Mile Island - 1979 A series of of failures and operational errors occurred that resulted in the release of a measurable amount of radio active material into the air. Alarms are not applied properly The use of alarms is not fully understood Alarm systems can avoid these incidents

Piper Alpha Oil Rig - 1988 An accumulation of errors and questionable decisions caused a catastrophic fire on the offshore platform causing 167 deaths and billions of dollars worth of damage PTP-Global Inadequate shift handovers Issues with false alarms

Texaco Milford Haven Refinery - 1994 PTP-Global A severe electrical storm caused plant disturbances. An explosion that occurred five hours later was a combination of failures in management, equipment and control systems during the plant upset. Twenty-six people were injured and damage of 48 million was caused. Too many alarms that were poorly prioritised Control room displays did not help the operators to understand what was happening During the last 11 minutes before the explosion, the two operators had to recognise, acknowledge and act on 275 alarms

Buncefield Oil Storage - 2005 PTP-Global In December 2005, a number of explosions occurred. A large fire engulfed a high proportion of the site. Over 40 people were injured; fortunately there were no fatalities. Alarms were not tested regularly

EMMUA 191 PTP-Global Alarm Systems: A Guide to Design, Management, and Procurement Not a standard or regulation Globally accepted as the benchmark for best practice Guidance on designing, managing and procuring alarm systems

ISA 18.2-2009 PTP-Global Management of Alarm Systems for the Process Industries Based upon the EEMUA 191 recommendations To address development, design, installation and management Aims to improve safety within process industries.

Alarm management is a process, not Alarm Philosophy Alarm Rationalization Implementation & Execution a product. Benchmarking &Assessment Analyze your system and understand your problems Maintenance Determine key performance metrics Operator workload Problem alarms Compare facility performance Gap analysis (you cannot improve what you cannot measure) Continuous Improvement

Alarm Management Lifecycle Benchmarking &Assessment Alarm Philosophy Alarm Rationalization Implementation & Execution Maintenance Continuous Improvement Corporate document that specifies Objectives of alarms Assign roles & responsibilities Procedures for defining alarms How to assign priorities Expected Operator responses Management of change

Alarm Management Lifecycle Benchmarking &Assessment Alarm Philosophy Alarm Rationalization Implementation & Execution Maintenance Continuous Improvement Systematic review and documentation of each configured/engineered alarmable tag in the DCS Store information in Alarm Database Objective is to optimize alarm quantity and quality Ongoing process, target 50 to 100 worst alarmable tag per day PTP-Global

Alarm Management Lifecycle Benchmarking &Assessment Alarm Philosophy Alarm Rationalization Implementation & Execution Maintenance Continuous Improvement Implement alarm strategy on DCS Implement advanced alarming strategies Alarm shelving Temporary disabling of alarms depending on process state Dynamic alarming Change alarm limits depending on process state Alarm grouping Use top level alarm to summarize multiple ones (with drill-down capability) Alarm eclipsing Disable an H alarm if the HH alarm limit is reached

Alarm Management Lifecycle Benchmarking &Assessment Alarm Philosophy Alarm Rationalization Implementation & Execution Integrate into work practices and embed into company culture Prevent unauthorized changes Track changes made Monitor performance Maintenance Continuous Improvement

Alarm Management Lifecycle Benchmarking &Assessment Alarm Philosophy Alarm Rationalization Implementation & Execution Analyze alarm floods during upsets Frequent intervention analysis Identify opportunities for additional process automation (supervisory control) Maintenance Continuous Improvement

Benefits of Alarm Management Compliance with best practice Improved safety measures Reduced maintenance costs and better plant operation Improves production and Human performance Reduces operator workload Improved shift handovers Reduced insurance rates

Well Designed Alarm Management The purpose of an alarm system is to direct the operator s attention towards plant conditions requiring timely assessment or action Alert, inform and guide the operators Prevent unnecessary shutdown Only present the operator with useful and relevant alarms Use prioritisation to highlight critical alarms Have a detailed response to each alarm Allow enough time for the operator to respond

Number of Alarms Number of Installed Alarms per operator Number Configured Under Over 1000 Simple A major technology. alarm system, Risk which that the will operator require significant and the 100 300-1000 300 Mixed Sophisticated annunciator computer and computer-based alarm handling alarm with display alarm investment systems throughout may have its a life safety cycle role and that which is not needs fully to can powerful be effective. tools for If logical purely processing computer based and suppression displays are of appreciated. Also poor alarm system performance may alarms is very desirable - possibly in combination with Common sense suggests that, in general, the more alarms installed per operator, the greater be developed the likelihood and maintained of problems to the with best spurious practices used, then the alarm system may not have to be alarms, high alarm rates, not available be etc. recognised within On the industry and other given if hand, it is management to a work small well. number priority sophisticated, individual displays but is of does critical need alarms. good Significant tools for dealing effort of alarms should not be with has viewed to basic be as expended problems, necessarily on e.g. ensuring desirable repeating a consistent alarms, as this alarms may and mean that the operator from will out be of unaware service plant. of important Effort should events. be put A into balance has to be struck, identifying and it key is inevitable alarms and that ensuring on a that large they complex are clearly require displayed. involvement Management of a team of commitment engineering needs and to plant a large number of alarms will be required. (7) considered approach to the design of individual alarms. The optimisation of operational performance is likely to be operational made to staff solve for operational several months. problems, but much may often be achievable with relatively little effort

Average Alarm Findings EMMUA Oil & Gas PetroChem Power Other Average Alarms per Day Average Standing Alarms Peak Alarms per 10 Minutes Average Alarms/ 10 Minute Interval Distribution % (Low/Med/High) 144 1200 1500 2000 900 9 50 100 65 35 10 220 180 350 180 1 6 9 8 5 80/15/5 25/40/35 25/40/35 25/40/35 25/40/35

Alarm Issues Priority (1) Priority of Alarm Critical (emergency) Number Configured 20 (Total) High 5% Medium 15% Low 80% EMMUA Oil & Gas PetroChem Power Other Distribution % (Low/Med/High) 80/15/5 25/40/35 25/40/35 25/40/35 25/40/35

Alarm Issues Flooding Alarm activations occur so fast that the operator becomes flooded by them and is unable to distinguish useful information, which can cause: The operator may work on a less important alarm, or Attempt to struggle with all of the alarms, or Give up completely on the alarm system

More Alarm Issues Chattering Alarms Comes in and clears at least three times in one minute Nuisance Alarms bad actors Where a few number of alarms cause significant amount of alarm activations. Masking Where an alarm sound cannot be heard above typical noise levels

What Companies are Currently Providing Very limited analysing alarm log on DCS Data being stored in Printer replacement products Issues limit access to data, normally 1-2 weeks history Extracting data to Excel and performing frequency DCS Limited systems Analysis are designed Frequency to run the process not generate alarm Very reports Collection Slow to of access data required can be manual; data going to the data source Database If data logs, can be data limited has to size, be only conditioned several very months complex history Very time consuming, can take several hours

What is an Analyser Displays Real-time Key Performance Indicators (KPI) KPI display for Systems, Area s and Connectors Seamless integration between displays Handover End of Shift Reports Improved Performance for Frequency Analysis Pre-formatted Reports Simple to use

40

Impact on data processing 2 We might forget or fail to remember important information 2 referring to our memory store 1 We might misread something, we might miss something important, we might choose to focus on certain things rather than others 3 We process the information and make decisions 3 We might make the wrong connections, we may not have all of the facts, we might make the wrong assumptions 4 We act accordingly in line with the decision made 1 We take in information through our senses 4 We might select the wrong response, we might set out to act in one way but get clumsy

Conclusion Understanding ASM. Focus on issues that provide a better understanding of ASM, insight into reducing future incidents and prepare ops teams to handle abnormal situations as they do occur. Training and skill development. Focus on anticipating and coping with abnormal situations. Communications. Critical to communicate issues to plant personnel using technology during normal, abnormal and ER situations. Procedural Operations. Focus on procedures to accomplish important tasks particularly during start-up and shut-down. Process Monitoring and control. Focus on automation technologies for effective operations. PTP-Global

Let us Co-Invent the Future Tim.southam@amec.com Tel: 01224 838251 Mob: 07793 018205