COSHH INFORMATION and PRODUCT SAFETY DATA. PRODUCT Lead acid electric storage batteries filled with dilute sulphuric acid

Similar documents
REVISION NO : 3 August 2010

EUROBAT CUSTOMER CARE PROGRAMME INSTRUCTIONS FOR THE SAFE HANDLING OF LEAD-ACID BATTERIES

Beats Product Information Sheet 20 Watt Hours

Material Safety Data Sheet

Material Safety Data Sheet

Fila Chemicals USA FILA CR CHEMTREC

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31 CYTOFIXX (CYTOLOGICAL FIXATIVE)

Creation Date: Revision Date: Page: 1 of 7

Li-Ion Batteries <100 Wh

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING SULPHURIC ACID DRAIN CLEANER

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

Ingredient % content Hazard data Cross linked Sodium Polyacrylite CAS No: Non chemical fillers Zeolite 1-10

Safety Data Sheet Avesta Neutralization Agent 502

1 IDENTIFICATION OF PRODUCTS AND MANUFACTURING COMPANY. DataSafe Genesis Odyssey Powerbloc Dry BB-10N. 9750Nxxxx to 9750M0835

Technical Data Sheet

SAFETY DATA SHEET POTASSIUM NITRATE

B.B. BATTERY CO., LTD. MATERIAL SAFETY DATA SHEET

This information is of relevance only if the battery is broken and this results in direct contact with the battery s contents. 4.

SAFETY DATA SHEET ID-11 Developer (Part B)

SAFETY DATA SHEET BLUECOL SCREENWASH

Safety Data Sheet. according to Regulation (EU) No. 1907/ Sulfuric Acid 1.0 N

Apple Product Information Sheet 20 Watt Hours

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture

ANTEC VIRKON SAFETY DATA SHEET HSD/1H (1) IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND COMPANY

Ingredient CAS Number Weight % ACGIH TLV PEL STEL Phosphoric Acid mg/m3 1 mg/m3 3 mg/m3

PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

Safety Data Sheet. Product #: Aspira Scientific 521 Cottonwood Dr. Milpitas, CA

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET WINTERHALTER A81 BLUE ENZYME DRAIN CLEANER

SAFETY DATA SHEET according to 1907/2006/EC, Article 31

GESSO PRIMER WHITE DALER ROWNEY, 2 Corporate Drive, Cranbury, New Jersey, USA

MATERIAL SAFETY DATA SHEET. SODIUM HYDRIDE, 65% dispersion in mineral oil, toluene soluble bags

MSDS FOR RECHARGEABLE LITHIUM-ION BATTERIES

Material Safety Data Sheet

SAFETY DATA SHEET DRAIN CLEANER

PRODUCT SAFETY DATA SHEET

Product Title Abstract

MATERIAL SAFETY DATA SHEET TOILET BOWL SANITIZER

Safety data sheet. DK-5900 Rudkøbing

SAFETY DATA SHEET EVO-STIK GRIPFILL SOLVENT FREE (Irl)

Swallowed Do not induce vomiting give 250 ml water to drink. Seek immediate medical attention.

SAFETY DATA SHEET NITRIC ACID (70% w/w)

ADDIT Last update: 20/04/2010, version 2.0 page 1 / 5

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

SAFETY DATA SHEET DUST REMOVER

SAFETY DATA SHEET BOSTIK AQUAGRIP 536

Material Safety Data Sheet For NiMH Batteries

Safety data sheet for product

SAFETY DATA SHEET PRIVATE LABEL SULPHURIC ACID DRAIN CLEANER SPD1047/SPD1046

Material Safety Data Sheet GREASED LIGHTNING SUPER STRENGTH CLEANER & DEGREASER

: Fairy Professional Original Washing Up Liquid 5L

SAFETY DATA SHEET BRONZE PUTTY HARDENER

SAFETY DATA SHEET EVO-STIK PLUMBERS MAIT

SAFETY DATA SHEET CLEANLINE GP MILD CONCENTRATED DETERGENT

Essential Oils Direct Ltd

Battery Information Sheet

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011

MATERIAL SAFETY DATA SHEETS

SECTION 1 - PRODUCT IDENTIFICATION

PRODUCT SAFETY DATA SHEET

SECTION 2: HAZARDS IDENTIFICATION Classification of the Substance or Mixture Classification (GHS-US) Not classified

OFF! DEEP WOODS SPORTSMEN INSECT REPELLENT I (PUMP SPRAY)

92699, 92708, 92732, 53825, 53810, : D-55Y Yellow UV Leak Detection Dye Concentrate

MATERIAL SAFETY DATA SHEET

PRODUCT SAFETY DATA SHEET

SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006 Issue 1 - Revision Date

OFF! CLIP-ON MOSQUITO REPELLENT

SAFETY DATA SHEET DOUBLE TT MAINTENANCE SPRAY

Safety Data Sheet According to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS

Safety Data Sheet Vertox Whole Wheat Bait

SAFETY DATA SHEET (REACH regulation (EC) n 1907/ n 453/2010)

Version: 1.0 Revision Date: 06/25/2013 Print Date: 06/25/2013 POOL TIME D.E. FILTER POWDER

Material Safety Data Sheet in accordance with 91/155/EEC

This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries.

Safety Data Sheet SOMAmer Reagent

Sodium Aluminum Tetrafluoride

1. PRODUCT AND COMPANY IDENTIFICATION

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

SAFETY DATA SHEET Revised edition no : 1 SDS/MSDS Date : 23 / 8 / 2012

SECTION 1 Identification of the substance/mixture and of the company

Safety data sheet according to 1907/2006/EC, Article 31

MATERIAL SAFETY DATA SHEET OF EPOXY ESTER KU 95 1/5

SAFETY DATA SHEET West Skyhawk Drive West Jordan, UT U.S.A. Phone

SAFETY DATA SHEET According to 91/155 EC

SAFETY DATA SHEET CLEENOL LIFT GRAFFITI REMOVER

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

: 5-Bromothiazole. Flotowgasse 18-22/2/ WIEN AUSTRIA Telefon : +43 (0) Fax : +43 (0) Emergency Phone # : +43 (0)

Product Bulletin INTEROX HYDROGEN PEROXIDE

SAFETY DATA SHEET Revised edition no : 1 SDS/MSDS Date : 26 / 11 / 2012

: CRYSTAL CLEAN DRAIN CLEANER CRYSTALS

SAFETY DATA SHEET LIQUITEX PROFESSIONAL SPRAY PAINT

SAFETY DATA SHEET according to 1907/2006/EC, Article 31

How To Safely Use A Lithium Ion Cell

Material Safety Data Sheet 1. PRODUCT AND COMPANY INDENTIFICATION

MATERIAL SAFETY DATA SHEET Sealed Nickel Cadmium Rechargeable Batteries

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

MATERIAL SAFETY DATA SHEET In accordance with CE Regulation n 1907/2006. Annex II.

CRC Industries Europe bvba. 12, Bld des Martyrs de Chateaubriant F Argenteuil Cédex

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 13 / 7 / 2012

SAFETY DATA SHEET TYRE SHINE

Transcription:

COSHH INFORMATION and SAFETY DATA acid electric storage batteries filled with dilute sulphuric acid Sulphate Sulphuric Acid (Max strength of 40%) HAZARDOUS CLASSIFICATION Corrosive Group 8 U.N. NUMBER 2794 PACKING GROUP 3 CONTAINER TYPE Polypropylene I.A.T.A - AIR TRANSPORT CLASSIFICATION Not classified for transport by air unless specified on individual products NATURE OF SUBSTANCES WITHIN THE BATTERY CORROSIVE Stored electrical energy Toxic compounds Explosive gas mixture involved during charging WARNING Hydrogen and oxygen gases are emitted from a battery during charge and at other times, such as when the battery is moved, shaken or subject to vibration. These gases contain small droplets of corrosive electrolyte. PROTECTIVE MEASURES Keep away from children Keep away from sources of ignition such as Naked Flames, Cigarettes and machinery that may cause sparks Keep and charge in a well ventilated area Wear protective clothing Do not ingest or allow electrolyte to come into contact with skin or eyes

ELECTROLYTE The electrolyte contained within the battery is a mixture of sulphuric acid and water (up to 40% sulphuric acid) CORROSION Attacks many metals with liberation of hydrogen gas which is highly flammable and has the potential to form explosive mixtures with air. Attacks clothing. Reacts with many chemicals with varying degrees of violence. Avoid contact with sulphide waste or arsenic. FLASH POINT Non flammable, however hydrogen gas may form. BOILING POINT 110 Degrees Centigrade / Celsius HEALTH RISKS ASSOCIATED WITH ELECTROLYTE GENERAL Corrosive and irritant. Inhalation and skin absorption are primary. INHALATION The vapour can irritate all parts of the respiratory system. CONTACT WITH EYES Burns the eyes severely. Permanent damage will occur if urgent medical aid is not sought. SKIN CONTACT Prolonged contact will cause tissue damage. INGESTION Will cause severe irritation and damage. SPILLAGE OF ELECTROLYTE Wear protective clothing such as a rubber or PVC apron with bib, rubber or PVC gloves and face visor. Neutralize all alkali (soda ash, sodium carbonate, sodium bicarbonate) washed down with water and scrubbed with a hard broom. ALL SPILLAGES MUST BE CONTAINED - DO NOT ALLOW TO ENTER MAIN DRAINAGE SYSTEM If electrolyte has entered a water course or sewer or contaminated soil or vegetation, your local Environment Agency Office should be advised.

EMERGENCY FIRST AID INHALATION Remove from exposure, rest and keep warm. Obtain medical attention immediately. CONTACT WITH EYES Wash out with plenty of water for at least 15 minutes. Obtain URGENT medical attention. SKIN CONTACT Remove contaminated clothing immediately and rinse affected skin with water for at least 15 minutes. Obtain URGENT medical attention. INGESTION If the electrolyte has been confined to the mouth give large quantities of water as mouth wash ensuring that it is NOT swallowed. If electrolyte has been swallowed give water to drink immediately and DO NOT induce vomiting. Seek URGENT medical attention. BURNS Apply a sterile bandage. Obtain medical attention. LEAD & LEAD COMPOUND BURNS and lead compounds are classified as being potentially toxic. The lead and lead compounds are well contained within the battery and the possibility of lead exposure is negligible. However, the battery cells should not be dismantled under any circumstances. Small amounts of arsenic and antimony are present in certain types of battery, and during the charging process there is a chance that stibine and arsenic may be given off as gases. The concentration of these gases is negligible and does not present any risk to health. Guidance notes are available from the Health and Safety Executive on Stibine and Arsenic (E.H.11 and E.H.12) HANDLING AND STORAGE Batteries are generally heavy and often awkward to handle. Care should be taken and correct lifting techniques employed. Keep the battery upright at all times. Always wear protective clothing when handling batteries, rubber or PVC apron, rubber or PVC gloves and eye protection. This is particularly important during fitting and charging operations.

Use only distilled water for topping up cells, other substances may cause a dangerous reaction in the cells. Top up the recommended level - do not over fill. Follow manufacturers instructions. Ensure batteries are maintained in dry, clean conditions, to avoid the possibility of corrosion and short circuits developing. No attempts should be made to repair a battery. This work involves a number of hazards and should be carried out by suitably trained persons in accordance with manufacturer's instructions. All labelling and manufacturer's instruction must be read carefully and complied with. The electrolyte is dilute sulphuric acid which is both poisonous and corrosive. It must not be allowed to come into contact with eyes, skin or clothing. Members of the public / non-trained persons must never remove electrolyte from a battery. This should only be carried out in a controlled environment by persons trained in that operation. DISTRIBUTORS If acid of recommended specific gravity is not available for the internal filling, the maximum concentration dilution with water should not exceed a specific gravity of 1.400 when measured at 16 degrees centigrade / 60 degrees farenheit. The use of a higher concentration of acid is highly dangerous and should only take place under the supervision of a qualified chemist. FIRE PRECAUTIONS The internal ohmic resistance of a lead acid battery is very low and a high current will flow if the terminals are short circuited. Sparks and molten metal may be ejected. It is therefore essential to avoid metal objects touching across the terminals. Before working on or near a battery, remove any metallic items from hands, wrist and neck, together with any such items that may fall from pockets. Always use insulated tools. Spanners should be of the single ended type. Do not place tools or any other conductive objects on top of batteries. Switch off all chargers before connection/disconnections are made to batteries. Charge off the vehicle in a well ventilated area. Hydrogen and oxygen gases are emitted from a battery when it is being charged and also at other times, particularly if it is moved, shaken or subject to vibration. These gases contain droplets of corrosive electrolyte. A Hydrogen/air mixture can produce a violent explosion if ignited, and it must be assumed that this mixture is present in the immediate vicinity at the top of the battery at all times.

The boxes and lid are made from several types of plastic components, which in normal conditions present no hazard. However, in the case of fire the plastic could decompose and may give off toxic vapours. Suitable respiratory protection should be worn during fire fighting. The following precautions must always be taken :- Charging and storage must be carried out in well ventilated areas. No smoking or naked flames should be permitted in the charging area or elsewhere during installations, inspections on or near the battery. TO EXTINGUISH FIRE USE CO2 OR SMOTHER WITH DRY POWDER DO NOT USE WATER OR FOAM AS THESE MAY CAUSE ELECTRIC SHOCK AGM AND GEL BATTERIES A.G.M. Batteries (Absorbed Glass Mat) acid electrical storage batteries with immobilized dilute sulphuric acid absorbed into the plates. Batteries are totally sealed with no danger of leakage. GEL Batteries (Gel filled batteries) acid electrical storage batteries with the electrolyte immobilized in a silica gel. Batteries are totally sealed with no danger of leakage. TYPE OF CONTAINER Polypropylene Immobilized Sulphuric Acid (Max strength of 40%) HAZARDOUS CLASSIFICATION Batteries : Immobilized electrolyte UN Number 2800 CLASS 8 I.A.T.A. TRANSPORT ASSOCIATION CLASSIFICATION These batteries are unregulated for air transport because they meet the requirements of : Special Provision "A 67" as promulgated by the International Civil Aviation Association (I.A.T.A. and I.C.A.O). They also meet the Vibration and Pressure Differential Tests of the International Maritime Dangerous Goods (I.M.D.G.) regulations.

TRANSPORT DETAILS FOR AGM AND GEL BATTERIES A.G.M. Batteries (Absorbed Glass Mat) acid electrical storage batteries with immobilized dilute sulphuric acid absorbed into the plates. Batteries are totally sealed with no danger of leakage. GEL Batteries (Gel filled batteries) acid electrical storage batteries with the electrolyte immobilized in a silica gel. Batteries are totally sealed with no danger of leakage. TYPE OF CONTAINER Polypropylene "Non spillable" Immobilized Sulphuric Acid (Max strength of 40%) HAZARDOUS CLASSIFICATION Batteries : Immobilized electrolyte. UN Number 2800, Class 8. Unregulated by DOT for transportation by Road, Rail, Sea and Air, because they meet the requirements of 49 CFR 173.159(d). The only transportation requirements are : (1) The batteries must be securely packed in such a way as to prevent the possibility of short circuiting. (2) The battery and outer packaging must be labelled "Non spillable Battery" I.A.T.A. TRANSPORT ASSOCIATION CLASSIFICATION These batteries are unregulated for air transport because they meet the requirements of : Special Provision "A 67" as promulgated by the International Civil Aviation Association (I.A.T.A. and I.C.A.O). They also meet the Vibration and Pressure Differential Tests of the International Maritime Dangerous Goods (I.M.D.G.) regulations. TRANSPORT DETAILS FOR WET FLOODED BATTERIES acid electric storage batteries filled with dilute sulphuric acid Sulphate Sulphuric Acid (Max strength of 40%)

HAZARDOUS CLASSIFICATION Corrosive Group 8 U.N. NUMBER 2794 PACKING GROUP 3 CONTAINER TYPE Polypropylene I.A.T.A - AIR TRANSPORT CLASSIFICATION Not classified for transport by air unless specified on individual products