Numerical Simulation of Automobile Windshield Defogging. Mark Doroudian Mindware Engineering

Similar documents
CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems

2013 Code_Saturne User Group Meeting. EDF R&D Chatou, France. 9 th April 2013

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Turbulence Modeling in CFD Simulation of Intake Manifold for a 4 Cylinder Engine

Best Practices Workshop: Heat Transfer

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

CCTech TM. ICEM-CFD & FLUENT Software Training. Course Brochure. Simulation is The Future

CONVERGE Features, Capabilities and Applications

CFD ANALYSIS CHALLENGES IN BUILDING SIMULATION FOR SIMBUILD2004 CONFERENCE. Ferdinand Schmid and Galen Burrell Architectural Energy Corporation

Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology

Introduction to CFD Analysis

Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling

ME6130 An introduction to CFD 1-1

COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE

Customer Training Material. Lecture 2. Introduction to. Methodology ANSYS FLUENT. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved.

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

Numerical Simulation of the External Flow Field. Around a Bluff Car*

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 4000 OPEN CHANNEL MIXER R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

CFD Analysis of Automotive Ventilated Disc Brake Rotor

CFD software overview comparison, limitations and user interfaces

CastNet: Modelling platform for open source solver technology

Introduction to ANSYS

Using CFD to improve the design of a circulating water channel

Aerodynamic Department Institute of Aviation. Adam Dziubiński CFD group FLUENT

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Natural Convection. Buoyancy force

Introduction to CFD Analysis

New Trends in the Field of Automobile Air Conditioning

CastNet: GUI environment for OpenFOAM

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Harvesting-Combine-Flow Simulation Technique

Coupling Forced Convection in Air Gaps with Heat and Moisture Transfer inside Constructions

Multiphase Flow - Appendices

Steady Flow: Laminar and Turbulent in an S-Bend

CFD ANALYSES OF FLUID FLOW AND HEAT TRANSFER IN PATTERNED ROLL-BONDED ALUMINIUM PLATE RADIATORS

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Condensation of Moist Air in Heat Exchanger Using CFD

. Address the following issues in your solution:

Introduction to ANSYS ICEM CFD

CHEG 3128 Heat, Mass, & Kinetics Laboratory Diffusion in Laminar Flow Regimes Modeling and COMSOL Tutorial Tutorial by Andrea Kadilak

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

CFD Analysis Of Multi-Phase Flow And Its Measurements

O.F.Wind Wind Site Assessment Simulation in complex terrain based on OpenFOAM. Darmstadt,

Thermal Simulation of a Power Electronics Cold Plate with a Parametric Design Study

NUCLEAR ENERGY RESEARCH INITIATIVE

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING

The influence of mesh characteristics on OpenFOAM simulations of the DrivAer model

GAMBIT Demo Tutorial

University Turbine Systems Research 2012 Fellowship Program Final Report. Prepared for: General Electric Company

CFD STUDY OF TEMPERATURE AND SMOKE DISTRIBUTION IN A RAILWAY TUNNEL WITH NATURAL VENTILATION SYSTEM

A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions

AIR STREAMS IN BUILDING FOR BROILERS

Fundamentals of Climate Change (PCC 587): Water Vapor

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

Performance Comparison of a Vertical Axis Wind Turbine using Commercial and Open Source Computational Fluid Dynamics based Codes

Energy Efficient Data Center Design. Can Ozcan Ozen Engineering Emre Türköz Ozen Engineering

CFD SIMULATION OF IPR-R1 TRIGA SUBCHANNELS FLUID FLOW

Measurement and Prediction Technology of Cooling Capability for Hybrid Drivetrain Components. Tadashi Yamada TOYOTA MOTOR CORPORATION

Set up and solve a transient problem using the pressure-based solver and VOF model.

CFD Analysis of Supersonic Exhaust Diffuser System for Higher Altitude Simulation

Lecture 7 - Meshing. Applied Computational Fluid Dynamics

NUMERICAL INVESTIGATION OF HEAT AND MASS TRANSFER IN A REFRIGERATED TRUCK COMPARTMENT

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

Automatic air conditioning system

Heat Transfer by Free Convection

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

V. N. Chougule, O. F. Daud, G. R. Gupta, V. H. Shelke, R. V. Ugale (Department of Mechanical Engineering, M. E. S. College of Engineering, India)

Lecture 16 - Free Surface Flows. Applied Computational Fluid Dynamics

Abaqus/CFD Sample Problems. Abaqus 6.10

This tutorial provides a recipe for simulating L

Laminar Flow in a Baffled Stirred Mixer

Customer Training Material. Shell Meshing Stamped Part ICEM CFD. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved. WS3.

Thermal Management of Electronic Devices used in Automotive Safety A DoE approach

Comparative Analysis of Gas Turbine Blades with and without Turbulators

Automatic air conditioning system

CHEMICAL ENGINEERING LABORATORY 3, CE 427 DRYING OF SOLIDS

Tutorial: 2D Pipe Junction Using Hexa Meshing

Chapter 12 - Liquids and Solids

Description of zero-buoyancy entraining plume model

Tomasz STELMACH. WindSim Annual User Meeting 16 June 2011

AIR DISTRIBUTION FOR COMFORT AND IAQ

CFD Analysis of Swept and Leaned Transonic Compressor Rotor

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

DESIGN AND SIMULATION OF LITHIUM- ION BATTERY THERMAL MANAGEMENT SYSTEM FOR MILD HYBRID VEHICLE APPLICATION

HowTo Rhino & ICEM. 1) New file setup: choose Millimeter (automatically converts to Meters if imported to ICEM)

Importing Boundary and Volume Meshes

Numerical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS

GEOMETRIC, THERMODYNAMIC AND CFD ANALYSES OF A REAL SCROLL EXPANDER FOR MICRO ORC APPLICATIONS

Comparison of Spherical and Membrane Large LNG. Carriers in Terms of Cargo Handling

Experimental Evaluation Of The Frost Formation

The Three Heat Transfer Modes in Reflow Soldering

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance

COMPUTATIONAL FLOW MODELLING OF FORMULA-SAE SIDEPODS FOR OPTIMUM RADIATOR HEAT MANAGEMENT

Introduction to COMSOL. The Navier-Stokes Equations

Transcription:

Numerical Simulation of Automobile Windshield Defogging Mark Doroudian Mindware Engineering

Abstract Visibility in the automotive industry is a major source of concern for the car manufacturers and safety design engineers. Water film (fog) that forms on the windshield during winter times would reduce and disturb the driver s visibility. This water film is originating from condensing water vapor on the inside surface of the windshield due to low outside temperatures. Primary source of this vapor is the passenger s breath, which condenses on the windshield. Warm and dry air, which impinges at certain velocity and angle relative to the windshield, will reduce the thickness of this water film (defogging) and hence improves driver s visibility. Therefore, a well-designed HVAC system will help reduce this water film thickness to an accepted level for visibility. CFD technology can be utilized to study the defogging process by tracking water vapor content and predict transient variation of condensed water layer on the glass surface. An analytical approach to simulate the defogging process including removal of the water vapor from the passenger cabin glass is discussed. The pre-processing including grid generation was performed using ICEMCFD. The transient thermal CFD simulation was performed using Fluent. Introduction Visibility in the automotive industry is a major source of concern for the car manufacturers and safety design engineers. Water film (fog) that forms on the windshield during winter times would reduce and disturb the driver s visibility. This water film is originating from condensing water vapor on the inside surface of the windshield due to low outside temperatures. Primary source of this vapor is the passenger s breath, which condenses on the windshield. Warm and dry air, which impinges at certain velocity and angle relative to the windshield, will reduce the thickness of this water film (defogging) and hence improves driver s visibility. Therefore, a well-designed HVAC system will help reduce this water film thickness to an accepted level for visibility. This paper presents the results of the application of CFD technology to study the defogging process by tracking water vapor content and predict transient variation of condensed water layer on the glass surface. The pre-processing including grid generation was performed using ICEMCFD. The transient thermal CFD simulation was performed using Fluent. CFD Grid Characteristics The passenger cabin of an automobile contains air with a relevant content of water vapors, originating from various sources (breath of passenger(s), outside humidity, etc.). These vapors condense on the inside surfaces of the cabin, especially on the windows (windshield, side windows, rear windows), due to lower temperatures of the outside air and radiation heat transfer effects. The condensed water film blocks the view from the inside and it has to be removed before the vehicle can be safely operated. In order to remove this condensed water film, the HVAC unit of the car is used in the defogging mode. In this mode, air with lower humidity than ambient supplied at certain velocities and temperatures into the cabin through the demister and defroster registers. A jet of air through the defroster nozzle and demister are directed at the windshield inner surface. The velocity of this jet of air is usually around 4 to 5 meters per second for a length of scale of.5 to 1.5 meters. The boundary layer thickness near the windshield is approximately 17000 micrometers. The fog layer smaller than 5 micrometer is considered as transparent. The fog layer thicker than 200 micrometer might result in drips and run offs. To study fog layers of that thickness, two-phase flow analysis is required. The CFD grid for defogging simulation for this study had the following characteristics: o Ten layers of prism cells adjacent to walls with fog layer. o The value of the turbulent y + =1 in the cells adjacent to walls with fog layer. o Height of the cells adjacent to walls with fog layer was greater than twice the fog layer thickness.

o The mesh was conformal (no hanging node adaptions or non-conformal interfaces) on the walls. CFD Grid Generation The ICEMCFD Cabin Modeler was used to create the minivan geometry. The Cabin Modeler was used to adjust the size of the default minivan cabin model. The dimensions of the cabin interior were taken off of an actual vehicle with a tape measure. Most often, the vehicle data exists in a CAD package and the physical model is not available. In that case, the CAD model is imported into ICEMCFD MED using one of the direct cad interfaces. Usually some CAD clean up is necessary before running ICEM grid generation tools. The CAD preparations include checks for single edges (i.e. no gaps, the fluid domain is enclosed within the cabin), proper curves and material points. For this cabin model, the grid resolution was chosen so that the resulting grid would represent the actual geometry as close as possible and without paying additional penalty of having high number of computational cells. In this interior cabin flow model, tetrahedral cells occupy most of the interior volume of the vehicle. The triangle faces of the tetrahedral cells, which were on the glass surfaces and some inlet/outlet boundaries, were extruded to represent four domains: 1- The boundary layer near the windows (air side) 2- The glass domain (solid side) 3- The ice domain (solid side) 4- Inlet and outlet regions. 10 layers of prisms were extruded in the boundary region with first layer initial height of 100 micrometers(the one next to the window shells), the height of these prisms was exponentially increased based on a growth rate of 1.1. (the 10 th prism layer height, which was attached to the tetras, was 0.235mm). See the figures below: Figure 1. The grid on a cut section through the cabin centerline. The red oval shows the defrost nozzle region and is shown in the next figure.

Figure 2. The grid on a cut section through the cabin centerline near the defrost nozzle opening into the vehicle cabin Figure 3. A section cut through the vehicle centerline shows the layout of the prism layers inside the computational domain The outer shells of the boundary layer prisms were used to extrude the five layer Glass prisms. The total height of those equidistant glass layers was 4.6 mm. Then another five equidistant layer was extruded to represent the Ice prisms with a total height of 0.4 mm. The inlet and outlet boundary regions were extended by extruding the outer triangular shells. This was done to account for the ducts that supply the defrost and demist registers. This flow model was constructed to perform both defogging and deicing simulation using this single computational domain. However, in the case of the defogging simulation the ice layer was omitted.

Boundary Conditions and Analysis Set Up The flow into the cabin was set to 400 kg/hour of air. The air was entering the cabin through the defrost nozzle, the driver side demist, and the passenger side demist. The air was exiting the vehicle through the air extractors in the rear of the vehicle. Some of the boundary conditions that were applied to the cabin defogging model: The walls that needed to be tracked for vapor thickness (inside surfaces of the green house glass) were flagged for the solver. The air Temperature at the inlets as a function of time by means of a user defined subroutine (UDF). The relative humidity(species mass fraction for water) at the inlet boundaries was assigned as a function of time(udf). Atmospheric conditions were applied at the outlet boundaries The glass temperature was set to 256 K. The cabin relative humidity was initialized at 50%. The thickness of the water condensate film which was assumed to be uniformly distributed on all the surfaces was set to 10 micrometers. The CFD solver that was used to perform the defogging simulation was Fluent. Fluent is a commercial CFD solver. The following solver functions were used for this defogging calculation: Init_water_distribution Calc_water_source Watervapor_source Solid_side_heat_flux Fluid_side_temperature Inlet_water_vapor Watervapor_diffusivity The strategy for performing the defogging simulation was to decouple the flow solution from the temperature and humidity calculations. This was done by assuming that the flow field in the cabin is driven by the flow coming through the HVAC unit and the buoyancy effects have a small effect on the defogging of the green house surfaces. Based on this assumption, the flow field in the cabin was solved for steady state conditions. This steady state solution for the flow field is then used as the initial conditions to solve for the temperature and humidity over a simulation period. The time step is usually in the range of 0.01 to 0.1 seconds. For this calculation, the time step was set to 0.06 seconds. During the simulation, the solver tracks the water vapor content through out the computational domain. The following assumptions were made regarding the water condensation on the walls: Water film is a continuous film of condensed water on a wall, contained in the first cell next to the glass. Surface tension, gravity effects are neglected on the water film Water film is not flowing or moving at any time. Evaporation/condensation will happen at specified walls only.

Water vapour is at saturation conditions at the interface between the fog layer and moist air. The solver delivers temperature, pressure and humidity for the cells next to the walls. The solver dbefogging module will determine the mass transfer process and direction based on the following criteria: Evaporation when Tcell>Tsaturation, deficit in specific humidity. Condensation when Tcell<Tsaturation, excess in specific humidity. Equilibrium (no mass transfer) when Tcell>Tsaturation, and excess in specific humidity or Tcell<Tsaturation, and deficit in specific humidity. Defogging module will determine the mass transfer rate by a diffusion law for specific humidity. Defogging module will update water film thickness based on the new mass transfer rate determined above. Defogging module will apply appropriate source/sink to the water vapour species in the cells next to glass. Defogging module will compute latent heat of vaporization/condensation and updating thermal boundary conditions to the solid/fluid sides of the glass. Results The results of the analysis that are of interest are: Species mass fraction of water Thickness of the water condensate on the walls Source term of water vapor on the pre-selected internal walls. Positive is evaporation, negative is condensation. Saturation temperature for water vapor in the cell layers next to the pre-selected walls. Gradient of the water vapor mass fraction in the cell layers next to the walls to show the potential for evaporation or condensation. Some of the results of the analysis are shown below. Figure 4. Particle traces released from the defrost nozzle and side demist inlets. The traces are colored by velocity magnitude.

Figure 5. Y Plus distribution on the green house surfaces Figure 6. Temperature (K) distribution on the green house surfaces

Figure 7. Velocity distribution near the green house surfaces Figure 8. Water vapor source term plot on the green house surfaces

Summary Figure 9. Film water thickness on the green house surfaces The ICEMCFD Cabin Modeler was used to create the grid for the interior cabin of a minivan. The ICEMCFD med was used to create to prism layers near the green house surfaces. The Fluent solver was used to perform a flow simulation to track the moisture content in the air and the water film thickness on the vehicle interior surface. These tools could be used to help design the defroster nozzle and the demister register quite sometime before the physical part is ready for testing. References 1. Fluent 6.0 User Guide Manual, 21(1-3), 2001 2. V. R. Voller and C. R. Swaminathan. Generalized Source-Based Method for Solidification Phase Change. Numer. Heat Transfer B, 19(2):175-189, 1991. 3. V. R. Voller and C. Prakash. A Fixed-Grid Numerical Modeling Methodology for Convection-Diffusion Mushy Region Phase- Change Problems. Int. J. Heat Mass Transfer, 30:1709-1720, 1987.