504 2004 Lippincott Williams & Wilkins



Similar documents
Zimmer Periarticular Proximal Tibial Locking Plate

Zimmer Small Fragment Universal Locking System. Surgical Technique

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

PERIPROSTHETIC IMPLANTS

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

NCB Distal Femur System. Surgical Technique

QUESTION I HAVE BEEN ASKED TO REHAB GRADE II AND III MCL INJURIES DIFFERENTLY BY DIFFERENT SURGEONS IN THE FIRST 6WEEKS FOLLOWING INJURY.

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Zimmer Periarticular Elbow Locking Plate System

Malleolar fractures Anna Ekman, Lena Brauer

How To Fix A Radial Head Plate

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

NCB Periprosthetic Femur Plate System. Surgical Technique

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Spinal Arthrodesis Group Exercises

.org. Distal Radius Fracture (Broken Wrist) Description. Cause

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

BONE PRESERVATION STEM

Fracture Care Coding September 28, 2011

Imaging of Lisfranc Injury

.org. Fractures of the Thoracic and Lumbar Spine. Cause. Description

Distal Radius Fractures. Lee W Hash, MD Affinity Orthopedics and Sports Medicine

Total Elbow Arthroplasty as Primary Treatment for Distal Humeral Fractures in Elderly Patients*


Scaphoid Non-union. Dr. Mandel Dr. Gyomorey. May 3 rd 2006

How To Use A Phoenix Retrograde Femoral Nail

Chapter 30. Rotational deformity Buddy taping Reduction of metacarpal fracture

Calcaneus (Heel Bone) Fractures

THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE

Structure and Function of the Hip

LISS PLT. The less invasive stabilization system for proximal tibia fractures.

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Posterior Referencing. Surgical Technique

V-TEK IVP System 2.7 System 4.0

INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

.org. Clavicle Fracture (Broken Collarbone) Anatomy. Description. Cause. Symptoms

.org. Ankle Fractures (Broken Ankle) Anatomy

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Syndesmosis Injuries

ASSOCIATED LESIONS COMPLICATIONS OSTEOARTICULAR COMPLICATIONS

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

TransFx External Fixation System Large and Intermediate Surgical Technique

Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires

Extra-articular Proximal Tibial Fractures: Nail or Plate?

TriLock 1.5 Implants for the Phalanges

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Versa-Fx II Femoral Fixation System Surgical Techniques

Rodding Surgery. 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD (800) (301)

Simplified surgery. Personalized performance.

The information contained in this document is intended for healthcare professionals only.

Total Elbow Arthroplasty and Rehabilitation

Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function

Management of common upper limb fractures in Adults and Children. Dr Matthew Sherlock Shoulder and Elbow Orthopaedic Surgeon

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Radial Head Fracture Repair and Rehabilitation

Adult Forearm Fractures

TRIGEN INTERTAN vs Stryker Gamma3 summary

The goals of surgery in ambulatory children with cerebral

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

PATIENT SPECIFIC PLATES FOR MANDIBLE: CUSTOM MADE PLATES FOR TRAUMA AND RECONSTRUCTION

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

Standard of Care: Tibial Plateau Fracture

Expert LFN. Lateral Femoral Nail.

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

Posttraumatic medial ankle instability

Rehabilitation Guidelines for Knee Multi-ligament Repair/Reconstruction

Achilles Tendon Repair, Operative Technique

LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures.

Expert TN. Tibial Nail.

LCP Compact Foot/Compact Hand.

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

ASOP Exams PO Box 7440 Seminole, FL The Manual of Fracture Casting & Bracing Exam 80% Passing ID # Name Title. Address. City State Zip.

Proximal Hip Fracture Open Reduction/Internal Fixation and Rehabilitation

Non Operative Management of Common Fractures

The Knee: Problems and Solutions

We compared the long-term outcome in 61

Introduction to the Bertram Hip Spacer

Transcription:

ORIGINAL ARTICLE Early Results of the Less Invasive Stabilization System for Mechanically Unstable Fractures of the Distal Femur (AO/OTA Types A2, A3, C2, and C3) Mark Weight, MD and Cory Collinge, MD Objectives: Historically, mechanically unstable fractures of the distal femur have been difficult to treat. Problems such as varus collapse, malunion, and nonunion frequently resulted before fixed-angle plates and indirect reduction techniques were popularized. More recently, the Less Invasive Stabilization System, or LISS (Synthes, Paoli, PA), has been designed to combine these 2 approaches with the intended goals of achieving adequate stable fixation and early healing. Early clinical results for the femoral Less Invasive Stabilization System have been promising. The purpose of this study is to evaluate the clinical results of patients with high energy, mechanically unstable fractures of the distal femur treated with the Less Invasive Stabilization System. Design: Retrospective analysis of a treatment protocol, consecutive patient series. Setting: Busy level II trauma center. Patients /Participants: Twenty-six patients with 27 high-energy AO/OTA types A2, A3, C2, and C3 fractures of the distal femur. Intervention: Treatment with indirect fracture reduction and internal distal femoral fixation using the Less Invasive Stabilization System. Main Outcome Measurements: Clinical and radiographic assessment. Results: Twenty-one patients with 22 fractures were available for evaluation at an average 19 months postinjury (range 12 35 months). The mechanism of injury included 12 motor vehicle collisions, 4 high falls, 5 motorcycle crashes, and 1 bicyclist struck by a car. Twenty patients had associated injuries. Six fractures were open. All fractures were comminuted; according to the AO/OTA fracture classification Accepted for publication April 28, 2004. From the Harris Methodist Hospital-Fort Worth and Fort Worth Affiliated Hospitals/John Peter Smith Orthopaedic Surgery Residency, Fort Worth, TX. The implants discussed in this manuscript have been 510K approved by the US Federal Drug Administration. No direct financial or other support has been provided to the authors from the makers of the implants discussed in this manuscript. Reprints: Cory Collinge, MD, 800 5th Street, Suite 500, Fort Worth, TX 76104 (e-mail: ccollinge@msn.com). Copyright 2004 by Lippincott Williams & Wilkins there were 4 A2, 3 A3, 12 C2, and 3 C3 fractures. All fractures healed without secondary surgeries at a mean of 13 weeks (range 7 16 weeks). There were no cases of failed fixation, implant breakage, or infection. Average joint line orientation relative to the femoral shaft axis (valgus) measured 99 on postoperative radiographs and 99 on final radiographs. A comparison of postoperative to healed final radiographs for each femur demonstrated no case with greater than a 3 difference in either varus or valgus. Complications included 1 malunion where the fracture was fixed in 8 of valgus and 2 cases of external rotation between 10 and 15. Painful hardware occurred in 4 patients, of which 3 underwent implant removal. The average knee range of motion was 5 to 114. Conclusions: The Less Invasive Stabilization System allows for stable fixation and facilitates early healing in mechanically unstable high-energy fractures of the distal femur. There were no patients with fixation failure, varus collapse, or nonunion in this at-risk population. This treatment safely allows for immediate postoperative initiation of joint mobility and the progression of weight bearing with early radiographic signs of healing. Key Words: minimally invasive plating, biologic plating, fracture fixation, femur, supracondylar femur (J Orthop Trauma 2004;18:503 508) Historically, the treatment of distal femur fractures has not produced a high percentage of excellent clinical results. Thin cortices, osteoporosis, a wide intramedullary canal, and fracture comminution have made stable fixation of these injuries difficult to achieve and maintain with traditional operative methods. In the 1970s and early 1980s, these injuries were approached with open reduction and internal fixation using established methods and standard implants. After early attempts at surgical treatment, however, relatively high complication rates were found that adversely affected clinical results. 1 9 Problems including infection, nonunion or delayed union, malunion, the need for bone graft, and stiffness due to delayed mobility were common. 2,7 12 Additionally, use of traditional methods to treat mechanically unstable distal femoral fractures resulted in problems with healing and failure of fixation resulting in varus collapse. 1,5,11 17 Subsequently, alternative meth- J Orthop Trauma Volume 18, Number 8, September 2004 503

Weight and Collinge J Orthop Trauma Volume 18, Number 8, September 2004 ods for comminuted or unstable fractures of the distal femur were proposed, including double plating, 13,18,19 use of plates for endosteal substitution, 1,20 22 and anatomically contoured plates. In the 1980s, advances in fracture care were applied to these difficult injuries and clinical results improved. First, indirect reduction and improved maintenance of the fracture biology was popularized by Mast et al and others. 1,23,24 Second, improvements in implant design occurred, leading to fixedangle plates such as the 95 angle blade plate and dynamic condylar screw. These fixed-angle implants impart a measure of stability to plate fixation in this area not previously available: in particular, they resist relative shortening of the medial side that may result in varus deformity. When these 2 treatments were employed together, dramatically improved rates of bone healing and fewer complications of treatment were found compared with historical controls. 2 Recently, locked plating systems have been developed, where screws are inserted that attach to the plate forming a multiple fixed-angle construct. Some of these systems are designed to apply the implants in a minimally invasive fashion that may diminish problems with fracture healing and infection. 21 23,25 28 Additionally, the Less Invasive Stabilization System, or LISS (Synthes USA, Paoli, PA), functions as an internal fixator, as the implant is designed not to compress the periosteum, thus potentially allowing maintenance of the vascularity to the injured bone (Fig. 1). Early clinical results for the distal femoral LISS have been promising. 19,29,30 To date, however, no study has specifically looked at the results of high-energy, mechanically unstable fractures of the distal femur (AO/OTA types A2, A3, C2, and C3) 31 treated with LISS. The purpose of this study is to evaluate early clinical and radiographic results of patients treated for these high-energy, mechanically unstable fractures of the distal femur (AO/OTA A2, A3, C2, and C3) 31 using the distal femoral LISS. METHODS Twenty-six patients identified from our trauma registry with 27 mechanically unstable distal femur fractures (AO/OTA 33-A2, A3, C2, and C3) 31 that were treated with LISS between August 1999 and October 2002. All fractures were treated by a single fellowship-trained orthopaedic trauma surgeon at a busy level II trauma facility. Treatment of patients with these injuries included a protocol of early fracture fixation using either LISS definitively or spanning of the fracture and knee joint with a temporizing external fixator. Open fractures, fractures with articular comminution, and polytraumatized patients were treated in a staged fashion. Definitive treatment included open reduction of any intra-articular fractures, indirect reduction of metaphyseal and metadiaphyseal fractures, and minimally invasive plate application and fixation. Operative treatment of the patients included in this report is as follows. Patients were positioned supine on a radiolucent operating table. A wide surgical prep of the entire lower extremity was performed, and prophylactic antibiotics were administered. If an external fixator was in place, it was carefully cleansed with iodine soap and paint and handled as little as possible throughout the case. Alcohol moistened sponges were placed around the pin sites and held in place with elastic gauze. A 5 to 10 cm skin incision was made along the lateral aspect of the distal femur and the iliotibial band fibers were incised in line with the skin. Displaced articular injuries were addressed first with reduction and application of 1 or 2 small fragment lag screws placed anterior to the expected site of plate placement. The surgical tactic was altered for comminuted articular fractures to include a lateral parapatellar approach to the joint to allow for improved access for articular reconstruction. Indirect reduction of the metaphyseal or metadiaphyseal fractures was achieved by a combination of methods. The external fixator (Stryker-Howmedica-Osteonics, Mahwah, NJ), FIGURE 1. Case example of a typical distal femur fracture treated in this series. A, Injury radiographs demonstrating high-energy distal femur fracture. B, Postoperative radiographs after minimally invasive treatment with LISS. C, Radiographs of healed fracture at 5.5 months. 504 2004 Lippincott Williams & Wilkins

J Orthop Trauma Volume 18, Number 8, September 2004 LISS for Mechanically Unstable Fractures of the Distal Femur if present, or a femoral distractor (Synthes USA) was used to gain length and was universally helpful in reduction. A wellplaced knee roll was used in all cases to aid in obtaining and maintaining reduction in flexion extension. Additional tools used for indirect reduction included the whirlybird device from the LISS set, Kirschner wire joysticks, or gentle manipulation of the condylar fragment using a large periarticular clamp (DePuy-Ace, Warsaw, IN). Using the radiolucent arm as a handle, the plate was inserted above the periosteum of the lateral femur in a submuscular tunnel beneath the vastus lateralis. The plate is designed to fit the anatomy of the distal femur and was applied such that the plate was nestled up next to the metaphyseal flare and lateral condyle of the distal femur by sliding it proximally and distally. The plate was centered on bone both proximally and distally and oriented flush with the lateral femoral condyle. A large periarticular clamp was used distally to gently hold the bone to the plate, which typically aided in the sagittal plane fracture reduction. All of these fractures had some level of comminution, and, in many cases, approximation of the normal anatomy was necessary. The opposite uninjured femur was useful as a template in many of these cases, as bony landmarks on the injured side were obscured by fracture. Great effort was then expended toward critically assessing the fracture alignment in varus-valgus, flexion extension, as well as rotation, prior to application of definitive fixation, a basic principle when using indirect reduction methods. Quality imaging was used, including an anterior-posterior (AP) view to assess varus-valgus, and a true lateral view to assess plate placement and flexion extension. Restoration of limb alignment in rotation was assessed clinically as compared to the contralateral side on preoperative examination. The successful use of the LISS system for the treatment of complicated fractures is technique dependent, and a learning curve exists. Once the LISS plate was inserted, a mini-open approach was performed at the proximal end of the plate to ensure that the plate was centered on the lateral side of the femur bone. A locking bolt in the most proximal screw hole was then inserted into the most proximal screw hole; this added stability to the aiming arm by rectangularizing the construct. Any gross adjustment of fracture reduction was done before provisional fixation was applied, using K-wires through the cannulated stabilization bolts. The whirlybird push-pull device was applied to bring the shaft of the femur toward the plate, fine tune the varus-valgus alignment, and augment stability of the provisional construct. At this time, great effort was again made to carefully scrutinize the fracture reduction in all planes before application of definitive fixation. Self-drilling locking screws (5 mm) were first placed for fixation into the condylar segment, and then into the shaft portion after drilling and measuring with K-wires. Considerable effort was made to apply K-wires and screws parallel to the joint surface as assessed on the AP imaging as a guide for restoring alignment. All screws were inserted in a unicortical fashion. They were placed using irrigation to cool the selfdrilling screws in an effort to prevent potential problems with bony necrosis and loss of fixation. Once adequate fixation was achieved, the guide system was removed and the wounds irrigated, dried, and closed. External fixators were only removed after all plating wounds were closed and sterilely dressed. Postoperatively, knee motion was initiated in patients on day 1 or 2 using physical therapy while they were awake. For those patients remaining intubated or in the intensive care unit, a continuous passive motion machine (CPM) in patients was used. Progressive weight bearing was encouraged once there was radiographic evidence of callus formation. Clinical and radiographic examinations were performed until the fracture was healed, and patients more than 12 months postinjury were called back in and examined. Records and radiographs were reviewed for demographics, fracture type, postoperative alignment, time to fracture healing (3 cortices bridged), and complications. Final clinical and radiographic evaluation was performed for knee range of motion, limb rotation, fracture healing, and final radiographic alignment. Final radiographic alignment was assessed using standing bilateral AP and lateral views of the distal femurs on long cassettes. Alignment in varus-valgus was assessed on long AP views with the patient standing, using the intramedullary line of the femur relative to that of the distal femoral articular surface. Flexion extension was evaluated on the lateral view by comparing the lines of the posterior (or anterior) cortical bone. Limb rotation was assessed with the patient prone and the knee flexed; this was compared to the contralateral side. RESULTS Of 26 patients, 2 died and 3 were lost to follow-up, leaving 21 patients with 22 fractures available for study. Of these 21 patients, the average age was 44 years (17 71 years) and follow-up averaged 18 months (range 12 35 months). Fourteen men and 7 women were available for inclusion. There was a high-energy mechanism of injury in all cases, including 12 motor vehicle collisions, 5 motorcycle crashes, 2 falls from a height greater than 10 feet, a parachuting accident (bilateral), and 1 bicyclist struck by a car. According to the AO/OTA fracture classification, there were 4 A2, 3 A3, 12 C2, and 3 C3 fractures (Fig. 2). 31 Only 1 patient had significant bone loss. Fifteen of 22 fractures extended proximally into the femoral diaphysis. Six fractures were open and were classified as 1 grade I, 1 grade II, and 4 grade III open fractures according to the system of Gustilo and Anderson. 32 There were 2 periprosthetic fractures, one in an active 71-year-old man with a total hip arthroplasty and the other in an active 71-year-old woman above a knee arthroplasty. Neither had profound signs of osteopenia radiographically nor were they being treated for os- 2004 Lippincott Williams & Wilkins 505

Weight and Collinge J Orthop Trauma Volume 18, Number 8, September 2004 teoporosis. Fourteen of 22 fractures were initially treated with a knee spanning external fixator, and definitive surgery was delayed until the patient and/or soft tissues had recovered enough to safely undergo surgery (mean 5 days, range 2 18 days). All fractures healed without secondary surgery. The mean time to healing was 13 weeks (range 7 16 weeks). There were no cases of failed fixation, nonunion, or infection, and no bone grafts were required. The mean time to full weight bearing was 11.5 weeks (range 8 15 weeks). Average joint line orientation relative to the femoral shaft axis measured 99 (valgus) on postoperative radiographs and 99 on final radiographs. 9 No patient measured a difference of more than 3 from postoperation to final radiographs. The average anatomic axis of the contralateral side measured 97. Only 1 of 22 fractures had greater than a 5 alteration of alignment in varus-valgus or flexion extension, a case found to be fixed in 8 of valgus relative to the other side. Two patients were found to have external rotation deformity of 10 to 15 relative to the contralateral side, but one of these had trauma to the contralateral femur. None had greater than a 15 difference in limb rotation from side to side. Four patients had symptomatic instrumentation at the lateral distal femur. Three had complete relief after implant removal, and 1 has surgery scheduled. Two patients underwent late knee ligament reconstruction, one for a symptomatic anterior cruciate deficiency and the other for an unstable posterolateral corner injury. No other secondary surgeries were performed. The average range of motion was 5 to 114 (extension range 2 22, flexion range 55 145 ). One patient with a C3 fracture pattern and associated severe ligamentous knee injury developed Brooker grade IV heterotopic ossification and marked knee stiffness. Excluding this patient, the average range of motion was 3 to 119. Extra-articular fractures or AO/OTA type A fractures had a mean arc of motion from 2 to 130, whereas intra-articular injuries or AO/OTA type C had an arc of motion of 7 to 102 (P < 0.01). The average knee range of motion for patients with open fractures was 3 to 117. FIGURE 2. AO/OTA classification demonstrating mechanically unstable fracture types treated in this series. DISCUSSION Minimally invasive plating techniques have been developed as a method of fracture fixation where additional soft tissue trauma is minimized and the fracture biology is left intact. The goals of these techniques are to restore the important anatomy, provide stable fixation, and to promote early fracture healing. This method of treatment has been applied to fractures of the distal femur, 19,21,22,29,30 as well as other complex lower extremity injuries from the hip to the pilon. 1,21,22,25,26,28 The use of fixed-angle implants has also shown benefits in the treatment of complex lower extremity injuries, including the distal femur. 10,20,21,24 Recently, LISS was developed with the rationale of combining the biologic advantages of a minimally invasive insertion technique with the mechanical advantages of a multiple fixed-angle device. Previous studies have demonstrated successful early results and relatively low complication rates using this treatment method for fractures of the distal femur. 19,29,30 The goal of this report was to specifically evaluate the results of LISS in mechanically unstable high-energy fractures of the distal femur where the stability of the fixation construct and preservation of fracture biology may be critical. All 22 high-energy, mechanically unstable fractures of the distal femur treated in this study group healed after the index procedure at an average of 13 weeks. There were no cases of fixation failure or implant breakage, and no fracture required bone grafting. Little information is available as to the results of treatments for high-energy injuries of the distal femur or those with mechanically unstable fractures that may be especially prone to healing or alignment problems and diminished clinical results. Two distinct patterns of distal femur injury have been recognized, 2,12,15,19,20,24,29 those in young patients resulting from high-energy trauma and those in elderly osteoporotic patients suffering low-energy injuries. To date, previous reports have made no clinical distinction between these 2 distinct types of injury, and results have been grouped together for analysis. 2 8,14 16,18 21,24,27,29,30 Historically, treatment failures have been relatively common, and complication rates have been high for these injuries. 2 7 Early attempts at open anatomic reduction and rigid internal fixation with traditional plates had significant problems, with delayed or nonunion occurring in 29% to 38% of fractures 5,33 and infection rates of 7% to 20%. 3,27,34 These 506 2004 Lippincott Williams & Wilkins

J Orthop Trauma Volume 18, Number 8, September 2004 LISS for Mechanically Unstable Fractures of the Distal Femur problems likely reflect the effects of further trauma on the surrounding soft tissues during the wide dissection required for the technique. Dramatically improved results have been reported in similar injuries using more biologic approaches and improved implants. 20,23,24 Reports by Bolhofner et al 20 and Ostrum and Geel 24 in treating distal femur fractures with techniques of indirect fracture reduction and internal fixation using 95 fixed-angle devices revealed markedly improved results compared with previous methods. They found early union in 93% to 100% of fractures and infections in only 0% to 2% of cases. The authors do, however, acknowledge certain limitations of their surgical technique, including the demanding nature of correct implant insertion and that it may not be suitable for all injuries. Early reports on distal femur fractures treated with similar principles using LISS have shown promising results as well. Schutz et al described their early results from multiple European centers 30 ; they found early healing in 37 of 40 patients (93%) treated for fractures with the distal femoral LISS. Kregor et al reported early union in 58 of 61 patients (95%) with distal femur fractures treated similarly with LISS. 29 The authors attribute successful early healing to vigilant maintenance of the fracture biology and strict adherence to the fixation principles of LISS. We have found that using indirect fracture reduction and fixation with LISS provides ample fixation to maintain fracture alignment in these high-energy and mechanically unstable fractures. In this series, the authors found no problems with fixation failure, varus collapse, or other changes in alignment postoperatively for injuries at risk, and radiographic alignment remained unchanged from operative fixation to final healed radiographs. Although earlier series demonstrated excellent fixation in the relatively osteopenic distal or condylar segment, 19,29,30 Schandelmaier et al found 4 patients whose fixation failed due to proximal screw pullout in their series of patients with a combination of low-energy and high-energy injuries. 19 Our results demonstrated no problems with either proximal or distal fixation. This may be attributed to the dissemination of information regarding the learning curve for this system and technique. Proximal failure due to eccentric placement of the plate on the lateral femur may result in inadequate purchase of the unicortical screws; this problem has been well recognized and may be avoided relatively easily. 19,29,30 Three of 22 fractures treated resulted in malunion found in this series. One patient experienced an 8 valgus deformity, and 2 others were found with mild deformities in external rotation. All were operatively fixed in these positions early in this series. Persistent deformity has been noted as the most common risk in minimally invasive fracture surgery, with rates as high as 32% or 44%. 19,21,22,28 The question no longer appears to be will the fracture heal or will it heal straight, but will we fix it straight? Most of the preliminary reports where malunion rates were extremely high described techniques that were still evolving at the time. 21,22,25,26 Although the risk for malunion is real, improved results should be expected if careful vigilance toward achieving alignment intraoperatively is observed. Limitations of this study include all of the shortcomings inherent to its retrospective nature. Also, there is no alternative treatment or control group included in this study with which to compare these results. There are 2 main strengths of this study. First, it is a consecutive series by a single surgeon who had the opportunity to consider and benefit from the learning curve of others. Strict adherence to the mechanical, biologic, and technical principles of LISS were upheld. Thus, these mostly positive clinical results should be reproducible by other orthopaedic surgeons. Second, the data analyzed only pertain to a limited type of patient, which are those who have experienced high-energy trauma resulting in comminuted or mechanically unstable fractures. These are patients that may reap the most benefit from these treatment methods, that is, a minimally invasive approach and use of fixed-angle implants. CONCLUSIONS A multiple fixed-angle and minimally invasive plating system such as LISS provides adequate stable fixation and facilitates early healing in mechanically unstable, high-energy fractures of the distal femur. There were no nonunions or patients who required bone grafting in this series of 22 similar fractures. There were no problems with fixation failure, varus collapse, or other postoperative changes in alignment in this at risk population. Radiographic alignment remained unchanged from operative fixation to final healed radiographs. It appears that LISS achieves the goals of stable fixation and early healing in these mechanically unstable injuries. It must be remembered that careful intraoperative attention should be given to restoring alignment in all planes. REFERENCES 1. Mast J, Jakob R, Ganz R. Planning and Reduction Technique in Fracture Surgery. New York, NY: Springer; 1989. 2. Neer CS, Grantham SA, Shelton ML. Supracondylar fracture of the adult femur. A study of one hundred and ten cases. J Bone Joint Surg. 1967; 49A:591 613. 3. Olerud S. Operative treatment of supracondylar fractures of the femur. Technique and results in fifteen cases. J Bone Joint Surg. 1972;54A: 1015 1032. 4. Pritchett JW. Supracondylar fractures of the femur. Clin Orthop. 1984:173 177. 5. Schatzker J, Horne G, Waddell J. The Toronto experience with the supracondylar fracture of the femur, 1966 1972. Injury. 1975;6:113 128. 6. Slatis P, Ryoppy S, Huttinen V. AO osteosynthesis of fractures of the distal third of the femur. Acta Orthop Scand. 1971;42:160 170. 7. Stewart MJ, Sisk TD, Wallace SL. Fractures of the distal end of the femur. J Bone Joint Surg. 1966;48A:784 807. 8. White EH, Russin LA. Supracondylar fractures of femur treated by internal fixation with immediate knee motion. Am J Surg. 1956;22:801 820. 9. Zehntner MK, Marchesi DG, Burch H, et al. Alignment of supracondylar fractures of the femur after internal fixation by AO/ASIF technique. J Orthop Trauma. 1992;6:318 326. 10. Altenberg AR, Shorkey RL. Blade plate fixation in nonunion and in com- 2004 Lippincott Williams & Wilkins 507

Weight and Collinge J Orthop Trauma Volume 18, Number 8, September 2004 plicated fractures of the supracondylar region of the femur. J Bone Joint Surg. 1949;31A:312 316. 11. Miclau T, Martin RE. The evolution of modern plate osteosynthesis. Injury. 1997;28(suppl 1):A3 A6. 12. Moore T, Watson T, Green S, et al. Complications of surgically treated supracondylar fractures of the femur. J Trauma. 1987;27:402 406. 13. Sanders R, Regazzoni P, Reudi T. Treatment of supracondylar intraarticular fractures of the femur using the dynamic condylar screw. J Orthop Trauma. 1989;3:214 222. 14. Sanders R, Swiontkowski M, Rosen H, et al. Complex fractures and malunions of the distal femur: results of treatment with double plates. J Bone Joint Surg Am. 1991;73A:341 346. 15. Schatzker J, Lambert DC. Supracondylar fractures of the femur. Clin Orthop. 1979;10:77 83. 16. Siliski JM, Mahring M, Hofer HP. Supracondylar-intercondylar fractures of the femur: treatment by internal fixation. J Bone Joint Surg Am. 1989; 71A:95 104. 17. Zickel R. Nonunions of fractures of the proximal and distal thirds of the shaft of the femur. Instr Course Lect. 1988;37:173 179. 18. Jazrawi LM, Kummer FJ, Simon JA, et al. New technique for treatment of unstable distal femur fractures by locked double-plating: case report and biomechanical evaluation. J Trauma. 2000;48:87 92. 19. Schandelmaier P, Partenheimer A, Koenemann B, et al. Distal femoral fractures and LISS stabilization. Injury. 2001;32(suppl 3):55 63. 20. Bolhofner BR, Carmen B, Clifford P. The results of open reduction and internal fixation of distal femur fractures using a biologic (indirect) reduction technique. J Orthop Trauma. 1996;10:37 44. 21. Krettek C, Schandelmaier P, Miclau T, et al. Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury. 1997;28(suppl 1):20 30. 22. Krettek C, Schandelmaier P, Miclau T, et al. Transarticular joint reconstruction and indirect plate osteosynthesis for complex distal supracondylar femoral fractures. Injury. 1997;28(suppl 1):31 41. 23. Henry SL. Supracondylar femur fractures treated percutaneously. Clin Orthop. 1998;350:80 84. 24. Ostrum RF, Geel C. Indirect reduction and internal fixation of supracondylar femur fractures without bone graft. J Orthop Trauma. 1995;9:278 284. 25. Collinge CA, Sanders RW. Percutaneous plating in the lower extremity. J Am Acad Orthop Surg. 2000;8:211 216. 26. Collinge C, Sanders R, DiPasquale T. Treatment of complex tibial periarticular fractures using percutaneous techniques. Clin Orthop. 2000;375: 69 77. 27. Farouk O, Krettek C, Miclau T, et al. The minimal invasive plate osteosynthesis: is percutaneous plating biologically superior to the traditional technique? J Orthop Trauma. 1999;13:401 406. 28. Helfet D, Shonnard P, Levine D, et al. Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury. 1997;28(suppl 1):42 48. 29. Kregor PJ, Stannard J, Zlowodzki M, et al. Distal femora fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results. Injury. 2001;32(suppl 3):32 47. 30. Schutz M, Muller M, Krettek C, et al. Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Result of a clinical study with special emphasis on difficult cases. Injury. 2001;32(suppl 3):48 54. 31. Orthopaedic Trauma Association Committee for Coding and Classification. Fracture and dislocation compendium. J Orthop Trauma. 1996;10 (suppl 1):41 45. 32. Gustilo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses. J Bone Joint Surg. 1976;58A:453 458. 33. Giles JB, DeLee JC, Heckman JD, et al. Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw. J Bone Joint Surg. 1982;64A:864 870. 34. Mize RD, Bucholz RW, Grogan DP. Surgical treatment of displaced, comminuted fractures of the distal end of the femur. J Bone Joint Surg. 1982;64:871 879. 508 2004 Lippincott Williams & Wilkins