ELASTOMERIC INLINE CHECK VALVES FOR CONTROL AND PREVENTION OF SANITARY SEWER OVERFLOW



Similar documents
Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

SANITARY SEWER BACKUP. Causes & Prevention

Number September 2014 SEWER LIABILITY

SEWER CLEANING, INSPECTION AND ASSESSMENT

Sanitary Sewer Master Plan

HYDROVEX. CSO, SSO and Stormwater Management Specialist Products and Services for North America

Unauthorized Discharges and Sanitary Sewer Overflows

DRAFT Public Outreach Document for What s an SSMP?

City of Dallas Wastewater Collection System: TCEQ Sanitary Sewer Outreach Agreement City Council Briefing January 17, 2007

TOWN OF SURFSIDE UTILITY UPGRADE PROJECT Project Completion

Tim Schneller, P.E. GBA Engineers and Architects

COMBINED SEWER OVERFLOW OPERATIONAL AND MAINTENANCE PLAN SUMMARY

At the end of today s seminar you should be better. Recognize the causes of Sewer Lateral backup. Identify techniques to protect your home from

BASEMENT FLOODING. Prevention Guide for. Homeowners

Sanitary Sewer Overflow (SSO) Incident Report Form

City and County of San Francisco 2030 Sewer System Master Plan TASK 400 TECHNICAL MEMORANDUM NO. 405

How To Build A Backwater Valve

OVER-HEAD SEWER ASSISTANCE GRANT

ecmar SECTION INSTRUCTIONS: Sanitary Sewer Collection Systems

First in Service First in Safety

M E M O R A N D U M. Among the standard conditions contained in the NPDES permit is also a Duty to

SANITARY SEWER SPECIFICATIONS

SAWS SSO Reduction Program

Scattergraph Principles and Practice Characterization of Sanitary Sewer and Combined Sewer Overflows

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY. a guide to PREVENTING SEWER BACKUPS AND FLOODING

Mitigating Basement Backups

COMBINED SEWER OVERFLOW LONG-TERM CONTROL PLAN Executive Summary

Protect Your Home From Flooding. A guide for Lethbridge Residents

Components of a Basement Flooding Protection Plan: Sewer System Improvements. November 2000

City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005

Almonte Sanitary District Sewer System Management Plan Adopted by the ALMONTE Board of Directors on_08/28/06

VILLAGE OF GRANVILLE SEWER BACK-UP and WATER LEAK POLICIES

CODE OF REGULATIONS OF THE NORTHEAST OHIO REGIONAL SEWER DISTRICT TITLE III SEPARATE SANITARY SEWER CODE

Sanitary Sewer Overflow Annual Report

ORDINANCE NO. 15 BE IT ORDAINED BY THE COUNCIL OF KANSAS CITY:

Town of Essex NE Lagoon. Service Area. Essex Plant. Service Area. Pumping Station No. 4. Wastewater Pumped To NE Lagoons (Treatment Plant No.

Kansas City s Overflow Control Program

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

Monterey Regional Water Pollution Control Agency. Sewer System Management Plan

Sanitary Sewer Overflows Response to EPA Rule Making

Extreme Wet Weather in Brookfield. How to Keep Your Basement Dry During Heavy Rains and Floods

SEWER BACKUPS WHAT TO DO AND HOW TO PREVENT

EPA Region 4 Introduction to Conducting Evaluations of Municipal Wastewater Collection System Management, Operation, and Maintenance Programs

Maine Department of Environmental Protection Program Guidance On Combined Sewer Overflow Facility Plans

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

Department of Public Utilities. Information for Property Owners & Residents about Sewer Backup Incidents. September 2014.

PREVENTING WET OR FLO ODED BASEMENTS

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

ELIMINATE STORM WATER FROM ENTERING SANITARY SEWER SYSTEMS

Home Drainage & Causes of Basement Flooding. Water

Sanitary Sewer Overflow/Facility Bypass Application

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

List of Figures List of Abbreviations Executive Report

Sanitary Sewer Smoke Testing

A Systematic Approach to Reduce Infiltration and Inflow (I&I) and Sanitary Sewer Overflows (SSO) PETE GORHAM, P.E. MIKE LYNN FEBRUARY 19, 2015

DEPARTMENT OF ENVIRONMENTAL QUALITY

What is a CSO / SSO? Sewer Overflows. Prevalence of CSOs in the US. Magnitude of Problem (Local)

Rainwater is directed away from walls at surface. Any water infiltrating is captured in drains below foundation

City of Hillsboro Inflow and Infiltration Elimination Program

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

Beechmont Park Project

Jay R. Smith Mfg. Co.

Sanitary Sewer Overflow(SSO)/Bypass Notification Form Instructions

Standard Operating Procedures Storm Drain System Maintenance

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

See Appendix A for additional information, or contact ASTM directly.

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH

AN UPDATE ON LOUISVILLE MSD s BASEMENT BACKFLOW PREVENTION PROGRAM 10 YEARS AND 6,700 INSTALLATIONS LATER

Corporate Report. Report from Transportation and Environmental Services, Environmental Services

Affordable Asset Management Making Use of the Data You Have: An Owner s Perspective

minimum deductible may be increased significantly.

Dry Weather Flow from Footing Drains and Service Connections

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

MIAMI-DADE LATERAL PILOT PROGRAM. James T. Cowgill, P.E. Rodney J. Lovett Franklin Torrealba, P.E.

GIS Applications for Regulatory Compliance

Volume Reduction in the Regional District of Nanaimo s Sanitary Sewers

Element 4: FATS, OILS, AND GREASE (FOG) CONTROL PROGRAM

Downspout Disconnection Program FAQs

The Town of Lakeshore Basement Flooding Information to Residents

CITY OF HIGHLAND PARK, ILLINOIS Stormwater Management Fact Sheet

Sewer System Management Plan (SSMP)

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

MARYLAND AVENUE BACKUPS DURING AUGUST 31, 2014 STORM EVENT COMMUNITY OUTREACH

foundation designed to keep water out of the basement.

Capital Improvement Plan City of Houston WASTEWATER TREATMENT FACILITIES

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Using Frequent Sewer Inspection to Prioritize Asset Management. May 1, John Schroeder, P.E., BCEE Drew Richards, EI Tim Fallara, P.E.

Water & Sewer Utility Maintenance SC-76

Transcription:

A Red Valve Company And Tideflex Technologies White Paper 600 North Bell Avenue Carnegie, PA 15106 (412)279-0044 www.redvalve.com ELASTOMERIC INLINE CHECK VALVES FOR CONTROL AND PREVENTION OF SANITARY SEWER OVERFLOW April 14, 2011 Harry Conrad Southeast Regional Sales Manager Red Valve Company, Inc. Southeast Regional Office 219 Albert Street Winter Springs, FL 32708 Phone: (407) 803-3472 Fax: (407) 327-0600 fax E-mail: hconrad@redvalve.com

Contents Abstract....2 Keywords..2 Introduction.....2 Causes and Effects of SSOs......3 All Elastomeric Valves in Combined and Sanitary Sewers.... 3 Using the All Elastomeric CheckMate Inline Check Valve for Control of Sanitary Sewer Inflow and Infiltration.......4 Advantages of Elastomeric Over Metal and Mechanical Checks........5 References.......6 Rev. 11/10/11 Page 1 of 6

Abstract It is costly for municipalities when sanitary sewer overflow (SSO) occurs. SSO can happen in a residential, commercial or institutional building, as well as in a street or environmentally sensitive area. The costs of cleaning, damages, noncompliance and possible litigation are daunting. Mechanical inline flapper and swing check valves are sometimes used to stop SSO in gravity sewer lines. However, they have an inherent inability to close off against sewage debris. Also, their high failure rate, frequently required maintenance, high headloss and high cracking pressure make them an ineffective solution. This is why the overwhelming majority of gravity sanitary sewer infrastructures do not use check valves. This paper is a brief discussion of the techniques and use of both Duck Bill and Inline All Elastomer Check Valves to prevent SSO, CSO and sewage back-ups; as well as controlling inflow and infiltration in gravity sanitary sewer infrastructures and provide odor mitigation. Keywords Sanitary Sewer Overflow, Combined Sewer Overflow, Infiltration, Inflow, All Elastomeric Duck Bill Check Valves, All Elastomeric Inline Check Valves Introduction Infiltration, inflow and backup of sewage in homes or businesses is costly and causes undo suffering. Use of engineering studies, video mapping, instrumentation and SCADA can reveal the sources of the problem. They do not solve the problem. Actual repair and/or replacement of buried pipe and infrastructure is expensive and requires engineering and extensive construction or relining of the pipes. In 1981, 1 to combat these and other problems relating to combined sewers, storm sewers and sanitary sewers; the EPA research division 2 commissioned Red Valve Company to create and test an All Elastomeric Duck Bill Check Valve. 3 In fact, the first All Elastomeric Duck Bill Tideflex Check Valve (54 ) that Red Valve manufactured and installed in New York City, in 1984, is still in service today. Combined sewer overflow (CSO) occurs in a system specifically designed with a combined sewer. 4 Currently, over 600,000 large and millions of smaller Tideflex Check Valves are solving CSO, storm sewer, SSO Figure 1 - and drainage backflow problems around the world. The latest All Elastomeric Duck Bill Tideflex Check Valve, Model TF-1, continues the tradition of reliable backflow checking in both outfall and inside the structure applications. No matter what the debris, head pressure and back pressure conditions are, Tideflex Elastomeric Check Valves are proven to perform over the years. Wards Island Outfall New York City, NY Installed in 1984 Rev. 11/10/11 Page 2 of 6

Causes and Effects of SSOs Occasional unintentional discharges of raw sewage from municipal sanitary sewers occur in almost every system. These types of discharges are called sanitary sewer overflows (SSOs). SSOs have a variety of causes including, but not limited to, blockages, line breaks, sewer defects that allow storm water and groundwater to overload the system, lapses in sewer system operation and maintenance, power failures, inadequate sewer design and capacity, and vandalism. The untreated sewage from these overflows can contaminate our waters, causing serious water quality problems and illness. Lack of capacity in the system causes back-up of sanitary flow into basements, causing property damage and threatening public health. EPA estimates that there are at least 23,000-75,000 SSOs per year (not including sewage backups into buildings). 5 All Elastomeric Check Valves in Combined and Sanitary Sewers Gravity sanitary sewer lines seldom use check valves even when SSO sources are known. Mechanical inline flapper and swing check valves are occasionally used to stop SSO in gravity sewer lines. However, they have an inherent inability to close off against sewage and debris. Also, their high failure rate, frequently required maintenance, high headloss and high cracking pressure make them an unpopular and ineffective solution In 1981, the EPA realized that municipalities with combined sewers (as well as tidal storm sewer systems) that were then using flap gates, incurred tremendous costs annually due to failing check valves. 7 Municipalities also had to increase their budgets to cover the high maintenance and operating expenses that mechanical check valves require. 6 On an EPA grant, the Elastomeric Duckbill Tideflex Check Valve was developed to eliminate the operational and maintenance problems associated with flap gates. 6 In particular, the elastomeric gates are designed to close tightly around objects that might otherwise prevent a flap gate from closing. 6 Figure 2 - Man Unclogging Sewer Overflow in Chennai, India Figure 3 - Failed Open Swing Flap Gate Figure 4 - An Elasomeric Duckbill Tideflex Check Valve Flowing There are physical characteristics that are required to achieve the low headloss, high back pressure and the close tightly around objects 6 abilities of the Elastomeric Tideflex Check Valves. The main one being that the duckbill opening is 1.57 X the I.D. of the pipe. 8 This is what enables the Tideflex Check Valve to achieve the abilities mentioned above. The size of the bill has no drawbacks in most Rev. 11/10/11 Page 3 of 6

applications. However, in gravity sanitary sewers it is often necessary modify the end of the pipeline or add a manhole to add the Tideflex Check Valve. Figure 5 - Tideflex Check Valves Open with Positive Pressure Figure 6 - Reverse Pressure Seals the Curved Bill of Tideflex Check Valves to Prevent Backflow Figure 7 - The Curved Bill of the Model TF-1 Closes on Backpressure, Even Sealing Tightly Around Debris Using the All Elastomeric CheckMate Inline Check Valve for Control of Sanitary Sewer Inflow and Infiltration In response, Red Valve Company has created the All Elastomeric CheckMate Inline Check Valve for gravity sanitary sewers, storm sewers, combined sewers and drainage applications. The CheckMate is designed to have the same benefits of Tideflex Check Valves, but with one big advantage. The CheckMate fits inside of the pipeline, which significantly reduces construction and installation costs. The CheckMate Inline Check Valve prevents backflow, opens with less than 1 of pressure and closes on debris. Because the CheckMate opens greater then 90% of the pipe I.D., it has extremely low headloss and it will pass just about anything that flows down the pipeline.. Figure 8 - The CheckMate Valve on Low Flow Manufactured by Red Valve Company, the CheckMate Inline Check valve is used for backflow prevention of sewage and odor mitigation. It is easily installed inside of the incoming and outgoing inverts and laterals of manholes and wet wells. It can also be located remotely from structures in buried pipe runs for area control of inflow and infiltration. Like the Tideflex Check Valve, the CheckMate Inline Check Valve s unique elastomer fabric-reinforced design provides a proven record of maintenance-free performance, cost savings and results that no other inline check valve can match. Also like the Tideflex Check Valve, the CheckMate closes around debris and has a 100% fabric and elastomer construction that eliminates corrosion problems. Because the CheckMate is made with the same unibody construction, there are no mechanical components to catch debris, corrode or fail. Both Tideflex Check Valves and CheckMate Inline Check Valves are made in the United States in Gastonia, NC. Rev. 11/10/11 Page 4 of 6

Advantages of Elastomeric Over Metal and Mechanical Checks Because of the severe service, continuous debris and highly corrosive conditions in gravity sanitary sewers, there are difficulties with service life and maintenance of metal and mechanical devices. Below is a short list outlining the advantages of elastomeric over metal and mechanical checks. Extremely low headloss. Durable, 100% elastomer construction. No mechanical parts. 25 year life expectancy. Operates on differential pressure. Virtually maintenance-free. Less than 1 of head pressure cracks open valve. Closes on debris. Silent, non-slamming. CheckMate Inline Check Valves are readily available in sizes 4 to 72. To view an animation of a CheckMate Inline Check Valves in action, visit http://www.tideflex.com/checkmate. For more information on Tideflex Check Valves, visit http://www.tideflex.com. Figure 8 Cross Section Views of a CheckMate Valve Showing the Various Stages of Flow - Open (Top), Flowing (Middle) and Closed (Bottom) Figure 9 - A Cross Section of CheckMate Valves Installed in a Manhole Rev. 11/10/11 Page 5 of 6

References 1 Abbreviated Tideflex Development Chronology, http://www.tideflex.com/beta/documents/documents2/check_valves/tideflex_timeline.pdf 2 EPA Risk Reduction Engineering Laboratory, Cincinnati, Ohio 3 EPA 600S289020 EPA Development Evaluation a Rubber Duck Bill Tide Gates, February, 1990 4 EPA Manual of Combined Sewer Overflow Control 635/R-93/007, Office of Research and Development EPA/625/R-93/007, September 1993 5 EPA National Pollutant Discharge Elimination System (NPDES) http://cfpub.epa.gov/npdes/home.cfm?program_id=4 6 The Tideflex Advantage: Still Ahead of the Curve PowerPoint Presentation, Video clip of interview with EPA s D. Richard Fields, 1984 7 EPA Manual of Combined Sewer Overflow Control 635/R-93/007, Office of Research and Development EPA/625/R-93/007, September 1993, Page 39, Elastomeric Tide Gates 8 Specification TT-TF-1 1.02:E: Bill slit conforms to 1.57 times the pipe diameter Rev. 11/10/11 Page 6 of 6