RN/RQ. Series. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Similar documents
Mechanical Rooftop Custom Capabilities

Bring the fresh in. Dedicated Outside Air Systems

Innovent LASER Packaged Fresh Air Conditioning Units

Defining Quality. Building Comfort. Heating and Cooling Coils

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

Defining Quality. Building Comfort. Precision. Air Conditioning

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Element D Services Heating, Ventilating, and Air Conditioning

Glossary of Heating, Ventilation and Air Conditioning Terms

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

MAC-120HE-01 Air-Cooled Chiller

Dehumidification Frequently Asked Questions

DOAS UNITS. MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR. Kitchens Hotel Corridors Laboratories. Paint Booths. Capacities Tons MBH

Nordic Heat Pump Product Guide

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

RPV - RP - RA air handling units

PMI-IF-H High Efficiency Gas Heat Units

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

ARMSTRONG AIR HEAT PUMPS

How To Buy A Lennox Power System

PLUG and PLAY VRV Connection

CE6500 Energy Recovery Ventilator

SECTION HEAT PUMPS

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

HVAC Systems: Overview

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

Pool Dehumidification Basics

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER

Installation Manual CLIFC Fan & Coil Variable Speed

KONRAD. Hybrid Fancoil Series

Lower Energy Costs with Rooftop Air-Conditioning Package Units

Geothermal Comfort Systems

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Answers to Your Questions from the Webinar

Creating Efficient HVAC Systems

Why Daikin? 2015 Houston, Texas USA

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

HSX19 Air Conditioner Up to SEER. Home Comfort Systems HSX19. The most quiet and efficient central air conditioner you can buy.

Customized Assessment Blueprint

Local Dealer:

Why Do I Need Precision Air Conditioning?

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

A. Section includes air conditioning units, controls and control panels.

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

ROOF TOP MOUNTED Air Handler Specification

SECTION AIR CONDITIONING UNIT

Think Green Think Renewable Think

Cooling kw Heating kw

york air-conditioning products Residential & VRF News 2015

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

SMALL DUCT HIGH VELOCITY COMFORT SYSTEM

Selection Tips For Air-Conditioning Cooling Systems

Single Package Vertical Air Conditioners. Vert-I-Pak

Chilled Water Precision Air Conditioner For Critical Application

The Different Types of Air Conditioning Equipment for IT Environments

Lesson 36 Selection Of Air Conditioning Systems

Johnson Air-Rotation Systems

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

Energy Efficiency in Industrial HVAC Systems

EnergyPro Building Energy Analysis. Assisted Living Building

How Ground/Water Source Heat Pumps Work

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Cooling Capacity CFM in. w.c. (125 Pa)

FBQ. DC Duct Heat Pump or Cooling Only

Energy Efficiency. Energy Efficient Home Cooling:

HVAC Basic Science - System Capacity

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

Cooling Capacity CFM in. w.c. (125 Pa)

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

ASME Packaged Indirect Fired Water Heater

Mechanical Systems Proposal revised

HVAC Checklist - Long Form

3/29/2012 INTRODUCTION HVAC BASICS

Evaporative Cooling for Residential and Light-Commercial

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

TWE+TTA TWE+TWA T.R.

FTQ. Daikin Inverter Ducted Heat Pump

SECTION MORTUARY REFRIGERATORS

Basics of HVAC Cleaning

Commercial Gas Furnace Upflow

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

SustainE(Sustainable Energy)

How To Design A Building In New Delhi

Transcription:

RN/RQ Series PACKAGED ROOFTOP UNITS, Heat pumps & OUTDOOR AIR HANDLing units RQ Series Features: Air-cooled or water-cooled condenser rooftop unit, with capacities from 2-140 tons Available as a chilled water or noncompressorized DX air handling unit, from 800-55,500 cfm Air-source, water-source, and geothermal heat pump options R-410A scroll compressors - one, two, or four stage cooling Variable capacity and variable speed R-410A scroll compressors for load matching cooling and improved part load efficiency Electric, gas, steam, or hot water heating Direct drive backward curved plenum supply fans Power exhaust and power return options Factory installed AAONAIRE total and sensible energy recovery wheels Double wall rigid polyurethane foam panel construction with a minimum R-value of 13 Service access doors with full length stainless steel piano hinges and lockable handles Sloped stainless steel drain pans RN Series Application Flexibility Minimizes Installation Time and Reduces Cost Makeup Air Applications Up to 100 % Outside Air Dehumidification and Filtration Capabilities Large Tonnage Rooftops with Small Footprints Factory Installed or Customer Specific Controls Options

RN/RQ Rooftop/Air Handler Series AAON RN and RQ Series rooftop units continue to lead the packaged rooftop equipment industry in performance and serviceability. Double wall rigid polyurethane foam insulated cabinet construction and direct drive backward curved plenum fans allow RN and RQ Series units to have quiet, energy efficient air flow with high static pressure capabilities. RN and RQ Series units also feature lockable hinged doors which provide service access to all sections of the unit. Superior Features Cabinet construction consists of rigid polyurethane foam panels with G90 galvanized steel on both sides and a closed cell polyurethane foam interior core. The inner wall protects the insulation from moisture damage, prevents microbial growth, and is easy to clean. Two inch rigid polyurethane foam insulated panels have a thermal resistance R-value of 13 or greater, which exceeds the R-value of a cabinet with four inch thick fiberglass construction. They also make the cabinet more rigid and resistant to damage and provide increased sound dampening. Access doors with full length stainless steel piano hinges and quarter turn, lockable handles provide improved reliability over single point hinges and make the unit easily serviceable. Corrosion resistant polyurethane paint exceeds a 2,500 hour salt spray test. Compressors and unit controls are contained within a compartment isolated from the air stream for ease of service and increased sound dampening. Direct drive backward curved plenum fans with rubber isolation mounts provide improved energy efficiency and reduced maintenance versus belt driven fans. Double sloped stainless steel drain pans eliminate standing water which can support microbial growth and stainless steel construction prevents corrosion that could lead to water leaks and contaminants in the air stream. Run test report, wiring diagram, and Installation, Operation, and Maintenance manual with startup form provided in control access compartment of every unit. 5 year non-prorated compressor warranty, 15 year non-prorated aluminized steel gas heat exchanger warranty and 25 year non-prorated stainless steel gas heat exchanger warranty. 6-30 ton RN Series Water-Cooled Condenser Packaged Rooftop Unit or Chilled Water Rooftop Air Handling Unit 55-140 ton RN Series Microchannel Air-Cooled Condenser Packaged Rooftop Unit

Air-Cooled or Water-Cooled Condensers Premier Options Variable capacity and variable speed R-410A scroll compressors for load matching cooling and improved part load efficiency. Refrigerant-to-water heat exchanger for improved unit efficiency. Air-source, water-source, and geothermal heat pump options for energy efficient heating. Factory installed total or sensible AAONAIRE energy recovery wheels. Humidity control options including: High Capacity Coils, Modulating Humidity Control, Return Air Bypass, and Mixed Air Bypass. Chilled water cooling coils allow unit to tie into existing chilled water system. Hot water or steam heating coils allow unit to tie into existing boiler system. Polymer e-coated coils, copper finned coils, and stainless steel coil casings are available to extend the life of the coils and protect them in corrosive environments. Power exhaust and power return fans with economizer for application flexibility. VFD controlled supply, exhaust, and return fans for precise airflow control, building pressure control, and reduced power consumption. Modulating gas heat with stainless steel heat exchanger provides greater fuel efficiency, longer heater life, and improved occupancy comfort. SCR (Silicon Controlled Rectifier) electric heat control for reduced power consumption, longer heater life, and improved occupant comfort. Multiple high efficiency air filtration options. Unit controls options including factory installed control-by-others. R-13 Double Wall Rigid Polyurethane Foam Panel Construction AAON is setting a new standard for performance with double wall construction using closed cell polyurethane foam insulation. Not only does it have more than twice the insulating R-value, it creates a far more rigid and stronger assembly with less air leakage than fiberglass insulated panels. Dehumidification AAON offers many humidity control options. High capacity cooling coils are available which allow for more dehumidification versus standard cooling coils. Return air bypass and mixed air bypass are available on RN Series units for single coil humidity control. Modulating humidity control is available to provide energy efficient dehumidification, even with low sensible heat loads, without the temperature swings common with on/off reheat systems. AAONAIRE Energy Recovery AAONAIRE energy recovery wheels, total or sensible only, provide energy savings by recycling energy instead of losing energy through exhaust air streams. AAONAIRE systems also enhance indoor air quality by allowing larger amounts of outside air to be provided to the space and through improved humidity control. Cutaway of panel showing thermal break and foam core. Factory installed AAONAIRE energy recovery wheel saves heating and cooling energy. RN/RQ Rooftop / Air Handler Series

Ease of Serviceability AAON equipment is designed from concept to completion with minimum service time as a primary factor. Readily accessible compressors and control components allow timely evaluation of service issues without delay. Colorcoded wiring diagrams allow fast connection identification and analysis and thus a reduction in down time and cost. Individual components and wires are also labeled for quick circuit evaluation. The result of this AAON standard procedure is low service cost and greater unit run time. Power exhaust or return Invisible footprint condenser design All double wall construction Air Handling Unit Option AAON RN and RQ Series outdoor air handling units provide a hydronic cooling and heating option. Gas, electric, steam, and hot water heating are available on an RN and RQ Series air handling units. Cabinet construction is similar to the packaged rooftop units with easily accessible coil connections. Gear driven economizer Slide out filter access Electric, Natural Gas, Liquid Propane, Hot Water, or Steam Heat 2-6 ton RQ Series Color-coded wiring diagram Slide out filter access Continuous bulb seal All components labeled R-410A scroll compressor

Ease of Serviceability Color-coded wiring diagram All components labeled Makeup Air Capability AAON RN and RQ Series units have makeup air capability and can be specified with up to 100% outside air. AAONAIRE energy recovery wheels are available on makeup air units to increase the unit s energy efficiency. High capacity cooling coils are available to handle the higher latent load of outside air. Modulating gas heat and SCR electric heat are available to provide energy efficient supply air temperature heating. Modulating humidity control is available to provide dehumidification without over cooling when the outside air humidity is above setpoint. Variable capacity scroll compressors are available to provide energy efficient supply air temperature. R-410A scroll compressors 26-70 ton RN Series VFD controlled variable speed scroll compressors provide load matching cooling and improve part load efficiency. } Variable capacity scroll compressors provide load matching cooling and improve part load efficiency. Gear driven economizer eliminates the excess play and binding that occurs with linkage type economizers.

RN Model RN-006 Cabinet Air-Cooled EER Water-Cooled EER RN-007 2,500 A Up to 14.0 NA RN-008 2,800 Nominal cfm Width* Height* Length* 2,200 RN-010 3,400 RN-009 4,000 RN-011 4,600 B Up to 13.9 NA RN-013 5,200 RN-015 5,800 RN-016 4,800 RN-018 NA 5,400 RN-020 C Up to 12.7 6,000 RN-025 7,500 Up to 16 RN-030 9,000 RN-026 8,600 RN-031 10,100 RN-040 12,800 D Up to 12.2 Up to 16.5 RN-050 15,000 RN-060 18,000 RN-070 21,000 RN-055 21,000 RN-065 24,000 RN-075 27,000 RN-090 22,000 E Up to 12.1 Up to 15.2 RN-105 26,500 RN-120 31,000 RN-130 34,000 RN-140 37,000 *Dimensions vary depending on options selected. All dimensions are in inches. Design cfm may be 30-50 % greater or less than nominal cfm. 79 44 82 96 50 88 101 59 110 100 97 155 142 102 294 6-30 ton RN Series Air-Cooled Condenser Packaged Rooftop Unit H Dimpled heat exchanger provides energy efficient heat transfer and has no internal turbulator, which can corrode over time. W L

Air-Source Heat Pump Option Energy efficient cooling and heating can be achieved by reversing the flow of the unit s refrigeration circuits. This allows the indoor coil to be used as either a cooling coil or heating coil. This is a more efficient method of heating than electric resistance heating because a heat pump can reject more heat to the space per the amount of energy used. Thus, the operating costs of heat pump heating are always less than the operating costs of electric resistance heating. Heat pump heating is also a more efficient method of heating than gas heating and, depending on the cost of electricity and natural gas or propane, heat pump heating can have less operating costs than gas heating. Direct Drive Backward Curved Plenum Fans are more energy efficient, quieter, and require less maintenance than belt driven fans. VFD controlled and ECM driven supply, exhaust, and return fans are available for precise air flow control, building pressure control, and reduced power consumption. Water-Source/Geothermal Heat Pump Option The constant temperature of the earth used as the exchange medium instead of the outside air temperature. A few feet below the earth s surface the ground remains at a relatively constant temperature. Depending on latitude, ground temperatures range from 45 f to 75 f. This ground temperature is warmer than the air above it during the winter and cooler than the air in the summer. The geothermal heat pump takes advantage of this constant temperature by exchanging heat with the earth through a ground heat exchanger. H Microchannel condenser coils are more efficient, lighter, and use less refrigerant than traditional fin and tube condenser coils. L W 2-6 ton RQ Series Water-Source/Geothermal Heat Pump Rootftop Units RQ Model RQ-002 Air-Cooled SEER Water-Cooled EER RQ-004 Up to 19.2 NA 1,600 Nominal cfm Width Height* Length* 800 RQ-003 1,200 RQ-005 2,000 RQ-006 2,400 44 43 82 *Dimensions vary depending on options selected. All dimensions are in inches. Design cfm may be 30-50 % greater or less than nominal cfm.

AAON Environmentally Friendly HVAC Product Family Custom & Cataloged Air Handling Units (800-200,000+ cfm) Condensers & Condensing Units (2-230 tons) Chillers (Air-Cooled, Evaporative- Cooled, Heat Pumps) (5-540 tons) Rooftop Units (2-240 tons) Outdoor Equipment Rooms (Chillers, Boilers & Pumps) Self Contained Units (3-70 tons) Heating and Cooling for... Auditoriums Convenience Stores Health Clubs Healthcare Facilities Homes Lodgings Manufacturing Museums & Libraries Natatoriums Office Buildings Restaurants Retail Stores Schools Supermarkets Residential Systems (2-5 tons) Geothermal & WSHP Units (2-230 tons) Air-Source Heat Pumps (2-230 tons) Defining Quality. Building Comfort. 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com It is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing, specifications, and/or design of its product without notice, obligation, or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE are registered trademarks of AAON, Inc., Tulsa, OK. RN/RQ R69530 130531