100 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES. Includes: Standby Power Rating Model QT100 (Bisque) kw 60Hz

Similar documents
Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Diesel Engine Driven Generators Page 1 of 6

Spark-ignited generator set

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

Diesel Generating Set

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

20 kw. 20 kw ISO. Synergy Variable Speed Residential Standby Generator Air-Cooled Gas Engine FEATURES

SG035. Industrial Gaseous Generator Set. SG035 35kW. primary codes and standards. Standby Power Rating 44kVA 35kW 60Hz

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

8/11 kw. 8/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

DIESEL GENERATOR SETS

16/20/22 kw. 16/20/22 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine

16/20/22 kw CENTURION SERIES

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

How To Use A Cat Diesel Engine

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

How To Control A Power Command Powerplant

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

C18 ACERT Fire Pump Tier bkw/ rpm

Magnum Mobile Generator MMG55 Specifications

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DGDK 60 Hz

New 27 hp 2 Cylinder Liquid-Cooled Engine

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

Marine Generating Sets 3.7 to 50 kva

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

Diesel Generator Set Model DFMB 60 Hz

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Annex-A TECHNICAL SPECIFICATION

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

LOAD BANK TESTING PROCEDURE

912. The engine for construction equipment.

3516 Industrial Engine

Technical Specification. Generating Set with Waukesha engine burning natural gas

It s storming outside. Neighbors have no power. For you, dinner s on in 15.

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Frequently Asked Questions Generators

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Centro-Matic Automatic Lubrication Systems System Controls

STANDBY PERMANENT MOUNT SERIES GENERATOR

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

C18 Diesel Oilfield Generator Set

Basic Nameplate Information

Signature and ISX CM870 Electronics

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

IGSA POWER GENERATION SYSTEMS

A Single Source for all Power System Solutions

APS100 Rental Generator Set Specification

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Auxiliary Power Unit (APU) for Military Vehicles

PM734F - Technical Data Sheet Winding 28

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

Explosion-Proof Electric Unit Heaters

Rotary screw compressors kw 5,5 7, , bar MODULO

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

300 Series PA Pump and Cooler Assemblies

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Cat Electronic Technician 2015C v1.0 Product Status Report 2/16/2016 9:19 AM

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Atlas Copco Generators

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

D RDC2 Controller d One digital controller manages both the generator set and

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

CorePower Home Standby Generator

Commercial Gas Furnace Upflow

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

Medical Air Systems: Scroll

POWER GENERATION.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Electric Coolant Pumps. Always at the Correct Temperature

residential & commercial Generators

Transcription:

GENERAC STANDBY GENERATORS Includes: Generac Naturally Aspirated Gaseous Fueled 6.8L Engine kw Liquid-Cooled Engine Generator Sets Standby Power Rating Model QT (Bisque) - kw 60Hz Two Line LCD Tri-lingual Digital Nexus Controller Isochronous Electronic Governor Closed Coolant Recovery System Smart Battery Charger UV/Ozone Resistant Hoses ±1% Voltage Regulation Natural Gas or LP Operation 2 Year Limited Warranty UL 2200 Listed Meets 2010 EPA Emission Regulations Meets CA/MA emissions requirement with optional catalyst FEATURES INNOVATIVE DESIGN & PROTO TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN. But it doesn t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. TEST CRITERIA: PROTO TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. An unequalled ±1% voltage regulation. SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.

Application & Engineering Data QT GENERATOR SPECIFICATIONS ROTOR INSULATION STATOR INSULATION Synchronous Class H Class H TELEPHONE INTERFERENCE FACTOR (TIF) <50 ALTERNATOR OUTPUT LEADS 3-PHASE/1-PHASE BEARINGS COUPLING LOAD CAPACITY (STANDBY RATING) EXCITATION SYSTEM VOLTAGE REGULATION SENSING 6/4 wire Sealed Ball Gear Drive kw Brushless Full Digital Three Phase REGULATION ± 0.25% GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 C above a 40 C ambient Insulation is Class F rated at 130 C rise All models are fully prototyped tested ENCLOSURE FEATURES Galvanized steel or aluminum weather protective enclosure options available Enclosed critical grade muffler Small, compact, attractive Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. ENGINE SPECIFICATIONS MAKE Generac MODEL V-type CYLINDERS 10 DISPLACEMENT 6.8 Liter BORE 3.55 STROKE 4.17 COMPRESSION RATIO 9:1 INTAKE AIR SYSTEM Naturally Aspirated VALVE SEATS Hardened LIFTER Hydraulic GOVERNOR SPECIFICATIONS Electronic FREQUENCY REGULATION Isochronous STEADY STATE REGULATION ± 0.25% ENGINE LUBRICATION SYSTEM OIL PUMP Gear OIL FILTER Full flow spin-on cartridge CRANKCASE CAPACITY 5 Quarts ENGINE COOLING SYSTEM Closed WATER PUMP Belt driven FAN SPEED 1670 FAN DIAMETER 26 inches FAN MODE Puller FUEL SYSTEM FUEL Natural gas, propane vapor CARBURETOR Down Draft SECONDARY FUEL REGULATOR FUEL SHUT OFF SOLENOID OPERATING FUEL PRESSURE 11-14 H 2 O ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR SMART BATTERY CHARGER RECOMMENDED BATTERY SYSTEM VOLTAGE 12V 30 Amp 12V, 2 Amp Group 24F, 12V, 525CCA 12 Volts Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271).

Generac Standby Generator - kw OPERATING DATA KW RATING (LP/NG) ENGINE SIZE 6.8 Liter V-10 GENERATOR OUTPUT VOLTAGE/KW - 60Hz LP AMP NG AMP CB Size 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 0.8 pf 120/240V, 3-phase, 0.8 pf 277/480V, 3-phase, 0.8 pf GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208-240 3-phase 480V 3-phase ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle 25% of rated load 50% of rated load 75% of rated load % of rated load ENGINE COOLING 417 347 301 150 Natural Gas (ft 3 /hr.) 130 371 713 991 1260 89 200 240 371 326 283 141 450 400 350 175 Propane (gal/hr.) (ft 3 /hr.) 1.4 52 4.1 149 7.9 287 11 400 13.9 507 Air flow (inlet air including alternator and combustion air) System coolant capacity Heat rejection to coolant Max. operating air temp. on radiator Max. ambient temperature COMBUSTION AIR REQUIREMENTS ft 3 /min. US gal. BTU/hr. 5,500 4.5 342,000 60 (150) 50 (140) Flow at rated power 60 Hz cfm 262 SOUND EMISSIONS IN DBA Exercising at 7 meters Normal operation at 7 meters EXHAUST Exhaust flow at rated output 60 Hz Exhaust temp. at muffler outlet ENGINE PARAMETERS cfm 61 72 888 516 (960) Rated synchronous RPM 60 Hz 2300 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration Altitude Deration 3% for every 10 C above - C 1.65% for every 10 F above - F 1% for every m above - m 3% for every 0 ft. above - ft. 25 77 183 600 RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. kw rating is based on LPG Fuel and may derate with natural gas.

INTERCONNECTIONS QT NEXUS CONTROL FEATURES 2-Line Plain Text LCD Display Simple user interface for ease of operation Mode Switch Automatic Start on Utility failure. 7 day exerciser -Auto -Off Stops unit. Power is removed. Control and charger still operate. -Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds Engine Start Sequence Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration) Engine Warm-up 5 seconds Engine Cool-Down 1 minute Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped. Smart Battery Charger Automatic Voltage Regulation with Over and Under Voltage Protection Automatic Low Oil Pressure Shutdown Overspeed Shutdown, 72Hz High Temperature Shutdown Overcrank Protection Safety Fused Failure to Transfer Protection Low Battery Protection 50 Event Run Log Future Set Capable Exerciser Incorrect Wiring Protection Internal Fault Protection Common External Fault Capability Governor Failure Protection *Single and three phase connections may vary, refer to the owner s manual for specific connection information. CIRCUIT BREAKER WIRE AND CONDUIT SIZE kw VOLTS CB AMPS LUG SIZE 240 1 Ø 500 3-2/0 to 400 mcm 240 3 Ø 350 (1) 600 mcm to #4 or (2) 250 mcm to 1/0 208 3 Ø 400 (1) 600 mcm to #4 or (2) 250 mcm to 1/0 480 3 Ø 175 #6 to 300 mcm

INSTALLATION LAYOUT QT Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2010 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0188690SBY-A / Printed in U.S.A. 10/12/10