PORTABLE AIR CONDITIONER

Similar documents
PORTABLE AIR CONDITIONER

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Use and Care Manual. Model CPA12KH AIR CONDITIONER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

2KW CERAMIC HEATER DHCER20. User Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

Meaco 30L and Meaco 40L dehumidifier instruction manual

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Important Safeguards

Get Me Cool Now Portable Air Conditioner User s Manual

USER S MANUAL HSC-24A

PORTABLE AIR CONDITIONER (LOCAL)

Instruction manual for Firstline FCS12000CH

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

PORTABLE AIR CONDITIONER

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Room Air Conditioners

Operating Instructions Air Conditioner

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

Portable Air Conditioner INSTRUCTION MANUAL

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

LUCCI AIRFUSION QUEST II CEILING FAN

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

Wine Cooler with Thermo-Electric Cooling & Heating Technology

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

REMOTE CONTROL MANUAL

Split Type Room Air Conditioner. KSWM units

Room Air Conditioners

Operating Instructions Air Conditioner

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

SAFEGUARDING THE ENVIRONMENT

GenStore Archive Cabinet

OPTIONAL SLENDER REMOTE CONTROL

Portable Air Conditioner

2-SLICE COOL TOUCH TOASTER

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

FOXAIR 60/50 ALL MODELS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Room Air Conditioners

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Taurus Series YORK Window Air Conditioners

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY

R410A SPLIT SERIES DC INVERTER

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

LG Wireless Remote Controller

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Dehumidifier D 850E. - Instruction manual version 02

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

FT-100 Fire Training Fog Machine User Manual English

Operating Instructions Split System Air Conditioner

OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit

Operating instructions in the back. PD1020L

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

FTXS. Wall Mount Heat Pump or Cooling Only

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

SWIMMING POOL HEAT PUMP Owners Manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

PORTABLE AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

VACUUM CLEANER INSTRUCTION MANUAL

LG Room Air Conditioner OWNER'S MANUAL

- 2 - IMPORTANT SAFETY REMINDERS

CARING FOR YOUR WATER HEATER

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Inverter Single Zone Ductless Mini Split Heat Pump

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

LG Multi Type Air Conditioner

WINDOW ROOM AIR CONDITIONER

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Operating Instructions

Dehumidifier Users manual. For Models: DH45S DH65S

Meaco DD8L desiccant dehumidifier Instruction Manual

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

Transcription:

MODEL: DIMC10RC / DIMC1RC / DIMC15RC INSTRUCTION MANUAL PORTABLE AIR CONDITIONER IMPORTANT INFORMATION Carefully read this instruction manual before you install or use your portable air conditioner. Please retain this manual for product warranty and for future reference. CAUTION 1. Make sure the inlet and outlet vents are never blocked.. Ensure the appliance is on a stable, even surface when operating to avoid water leakage. 3. Do not operate this unit in an explosive or corrosive atmosphere. 4. When switched to cooling, only operate this unit in ambient temperatures between 17 C and 43 C. For heating, only operate this unit in ambient temperatures between 5 C and 3 C. 5. Clean the air filter frequently to ensure efficient operation. 6. To prevent compressor damage when the unit has been operating and is turned off, please wait at least 3 minutes before restarting. 7. This unit needs to be plugged into a 0-40V ~ 50Hz AC, 10 Amp power outlet. 8. Do not use any extension cords with this unit. 9. This unit is for indoor operation only. 10. Open the adjustable air vent and extend the exhaust pipe (and drain pipe, if fitted) to the closest window before using. 11. Only ever have a professional technician, manufacturer or service agent replace a damaged power cord. 1. The batteries from the remote control must be removed and disposed of safely, before the appliance is scrapped. 13. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 14. Children should be supervised to ensure that they do not play with the appliance. Important. The air conditioner must always be stored and transported upright. In case of doubt we suggest you wait for at least 4 hours before operation. (Please keep unit upright at all times) 1

PACKAGE CONTENTS CONTROLS AND DISPLAY Portable air conditioner DIMC10RC Remote control Batteries for remote control Extendable window kit Water tray PARTS 1. Controls. Remote receiver 3. Adjustable air vent 4. Window kit adaptor 5. Exhaust tube 6. Upper drain plug 7. Cool air inlet 8. Cool air filter 9. Hot air inlet DIMC1RC/ DIMC15RC 1. POWER 10. Hot air filter Press the POWER button to turn the unit "ON" or "OFF". The portable air conditioner is fitted with a compressor delay protection circuit. This 11. Lower drain plug protects the unit from possible damage due to rapid starting and stopping of its compressor. Compressor operation begins 3 minutes after the unit is switched on or the mode is switched from dehumidify to air conditioning.. FUNCTION Press this button to select cooling, heating or dehumidification. When the heating or dehumidification functions are used the upper drain plug (6) must be Note: Make sure drain plugs (6 and 11) are fitted before use. removed and a drain hose must be attached. 3

3. TEMP+ In cooling function, this button raises the set temperature by 1 C each time it is pressed to a maximum of 30 C. In heating function, this button raises the set temperature by 1 C each time it is pressed to a maximum of 5 C. 4. TEMP- In cooling function, this button lowers the set temperature by 1 C each time it is pressed, to a minimum of 17 C. In heating function, this button lowers the set temperature by 1 C each time it is pressed to a minimum of 15 C. The time taken to reach the desired set temperature will depend on the environment and the size of the space in which the unit is operating in. For example, if the ambient temperature is too hot or the room is too large, the rate at which the temperature descends will be slow as the cooling may be less effective. 5. DISPLAY The display indicates the current, the set temperature or the timer setting. When the timer or temperature is adjusted, the new setting is shown then the display returns to the current set temperature. The display is also used to show error codes should a fault occur, see ERROR CODES. 7. TIMER ON/OFF button for the programmable timer. The timer can be used to turn the unit on automatically after a set time delay is complete. 1. With the unit OFF, press the "TIMER" button to set the desired time delay before the unit is to start.. Choose the function desired (cooling, heating or dehumidification.) 3. Once the set time delay is complete, the unit will turn on automatically. 4. If you press the POWER button before the time delay is complete, the delay will be cancelled and the unit will turn on immediately. The timer can be used to turn the unit off automatically after a set time period is complete. 1. With the unit ON, press the "TIMER" button to set the desired time for the unit to remain on.. Once the set time period is complete, the unit will turn off automatically. 3. If you press the POWER button before the time delay is complete, the delay will be cancelled and the unit will turn off immediately. 6. SPEED Press SPEED to select LOW, MEDIUM, HIGH or AUTO fan speed. If AUTO fan speed is selected, the unit operates at maximum capacity and high fan speed while the room temperature is more than C from the set temperature. When the room temperature is within C of the set temperature, the unit operates at medium capacity and fan speed. Once the room temperature equals the set temperature, the unit will operate at minimum capacity and low fan speed to efficiently maintain the desired temperature. When HIGH, MEDIUM or LOW speed is selected, the unit operates at maximum capacity until the set temperature is reached. The fan operates at the selected speed. 8. SLEEP Press the SLEEP button to select the sleep comfort mode. When the unit is cooling and sleep mode is selected, the unit will raise the set temperature 1 C each hour to a maximum of C over two hours. When the unit is heating and sleep mode is selected, the unit will lower the set temperature 1 C each hour to a maximum of C over two hours. These temperatures will be maintained for the balance of the time set and help maximize sleep comfort. When setting the "sleep comfort" mode, please ensure that you set the number of hours required by using the TIMER function. The hours set will be shown on the display by pressing either the TEMP+ or TEMP- buttons. 4 5

REMOTE CONTROL INSTALLATION Unpacking the unit. 1. Remove the exhaust tube from its storage under the rear air outlet. Replace the rear air outlet.. Install the exhaust tube by rotating it clockwise onto the rear air outlet. Please ensure it is fully inserted before use. Locating the unit. Install the portable air conditioner in a flat location POWER FUNC TIMER AUTO HI MID LOW SLEEP ON/OFF switch Function selector Timer programming Automatic fan speed High fan speed Medium fan speed Low fan speed Sleep comfort mode selector Raise Set Temperature Lower Set Temperature with adequate space to ensure the air inlets and outlets will not be blocked. Keep a minimum clearance of 50cm from walls and other objects. Locate the unit to allow the exhaust pipe and drain hose to reach a suitable window, as shown. Avoid sharp bends or kinks in the exhaust pipe. The optional adjustable window slider is included to ensure the exhaust pipe is held in place (in the window) and prevents expelled hot air re-entering the room. The appliance should not be used in damp areas such as a laundry or bathroom. Do not place the unit where it will be in direct sunlight as it may overheat and turn off. 6 7

ADJUSTABLE WINDOW SLIDER KIT WATER DRAIN (Error code E4) The adjustable window slider kit is installed as shown below. When the air conditioner is used, excess water condensation may be produced that cannot be removed via the exhaust hose. This water is captured by an internal container. When this container is full, the unit will stop working and display the E4 error code. When the error code E4 is displayed the water collected in the internal container must be manually drained: 1. Switch off and unplug the unit.. Move the unit to a suitable place to drain the water. Consider placing a tray or suitable container under the outlet pipe to catch the drained water. HEATING AND DEHUMIDIFICATION When the heating or dehumidification functions are used the upper drain plug (6) must be removed and a drain hose must be attached. 3. Remove the lower drain plug (11), refer to parts illustration. 4. Slightly tilt the unit to the rear to drain the water. 5. Replace the drain plug. Make sure the drain plug is re-fitted to the drain outlet before use. Extend the exhaust to the window before the unit is restarted. HEATING When using the heating function move the rear air outlet with the exhaust tube to the front of the unit as below: The outlet exhaust must still be attached to the window when using the heating function. Return the outlet and tube to the rear of the unit for cooling or dehumidification. 8 9

MAINTENANCE WARNING: ALWAYS UNPLUG THE UNIT BEFORE MOVING OR CLEANING. CARE OF THE UNIT 1. Only plug the unit into a suitable 0-40V~ 50Hz AC 10 AMP power supply.. Hold the plug when unplugging the unit, never pull on the cord. CLEANING Air filters The air filters located on the rear of the unit can be removed simply by pulling the filter frame slightly out and then across to the side. 3. Do not place the unit in direct sunlight. This can fade the plastic case. 4. Do not operate the unit in a confined space. 5. Do not place objects on top of the unit. This blocks the air outlet. 6. Do not place the unit where the air inlets or outlets may be blocked by curtains or furniture. 7. Keep the filters clean. OVERHEAT PROTECTION This unit is fitted with an overheat prevention device. If the unit overheats it will automatically turn off. The unit can be restarted after 30 minutes. Cabinet Wipe with a damp cloth and polish with a soft cloth. ERROR CODES Error codes are shown on the display should a fault occur. E1: Indicates open circuit or short circuit in the room temperature sensor. E: Indicates open circuit or short circuit in the pipe temperature sensor. E4: Indicates the internal water container is full. Refer to WATER DRAIN. If error code E4 persists, please contact an authorized service centre. 10 11

TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself. Unauthorized repairs may result in the loss of warranty and can endanger the user and their property. Problem Cause Solution The air conditioner does not operate. The air conditioner does not seem to operate efficiently. No power supply. Error code E4 is shown, indicating the internal water container is full. The start timer function is active. The air conditioner is in direct sunlight. Windows or doors are open. Connect to a functioning power supply socket and switch on. Empty the internal water container. (Refer to WATER DRAIN) Press the POWER button to deactivate the TIMER function. Close the curtains. Close windows and doors. WARRANTY The warranty period is 4 months from the date of purchase. Glen Dimplex Australia Pty Ltd Unit 1, 1 Lionel Road. Glen Dimplex Australasia Ltd 38 Harris Road, East Tamaki, Mount Waverley VIC 3149. Manukau, Auckland 013 Australia New Zealand Ph: 1300 556 816 Ph: (09) 74 865 Fax: 1800 058 900 Fax: (09) 74 847 Web: www.dimplex.com.au Web: www.dimplex.co.nz The filters are dirty. Clean the filters. The air conditioner is noisy. The compressor does not work. The air inlets or outlets are blocked. The room temperature is below the set temperature. The air conditioner is not level. The overheat protection is activated. Remove the blockage. Lower set temperature. Place the air conditioner on an even, solid surface. Wait 30 minutes until the temperature has decreased, then turn the air conditioner on again. Note: Compressor operation begins 3 minutes after the unit is switched on. DISPOSAL Do not dispose of electrical appliances as unsorted municipal waste. Use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the ground water, polluting the food chain and damaging health and well-being. The remote control does not function. The distance between the remote control and the air conditioner is too great. Move closer to the air conditioner. Aim the remote control directly at the control panel. The batteries are flat. Replace the batteries. If you have any issues with your unit, please contact Glen Dimplex for your nearest service agent. Proof of purchase is required at the time of service. 1 13

SPECIFICATIONS Model No. Power Source Power Consumption (EN14511) Rated Power (EN60335) Cooling / Heating Capacity Air Flow Moisture Removed Refrigerant Min. room size Max. room size Dimensions (mm) Net Weight DIMC10RC 0-40V ~ 50Hz AC 145W / 1090W 180W / 1100W 3000W / 3000W 360 M 3 /H 40 L/DAY R410A 10m m 300W x 507D x 67H 8KG DIMC1RC 0-40V ~ 50Hz AC 145W / 146W 1480W / 1300W 3500W / 3500W 450 M 3 /H 60 L/DAY R410A 10m 5m 300W x 550D x 760H 9.5KG Model No. Power Source Power Consumption (EN14511) Rated Power (EN60335) Cooling / Heating Capacity Air Flow Moisture Removed Refrigerant Min. room size Max. room size Dimensions (mm) Net Weight DIMC15RC 0-40V ~ 50Hz AC 186W / 1566W 1700W / 1500W 4400W / 4400W 550 M 3 /H 75 L/DAY R410A 10m 9m 300W x 550D x 760H 31.5KG 14