H15 Series BASO Automatic Shutoff Pilot Gas Valve

Similar documents
M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

G670 Intermittent Pilot Ignition Controls

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

G234X-55 Conventional Gas Boiler

Explosion-Proof Electric Unit Heaters

Commercial Gas Water Heaters

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Pressure Switch for gas and air

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Commercial Gas Water Heaters

300 Series PA Pump and Cooler Assemblies

Commercial & Industrial Propane Regulators and Meters

NAVIEN AMERICA INC FITCH AVENUE

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

P70, P72, and P170 Series Controls for Dual Pressure Applications

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

OBSOLETE. VS8420 Millivolt Gas Valve

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Instantaneous gas water heater

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl.

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

289 Series Spring-Loaded Relief Valves

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

HEAVY DUTY STORAGE GAS

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Commercial Gas Cooking Thermostats

Fisher 377 Trip Valve

PLUMBING RE-SUBMITTAL

San josé OWNER S MANUAL

Electric Water Heater

Your safety and the safety of others are very important.

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Commercial Electric Water Heater

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

Technical Specification. Generating Set with Waukesha engine burning natural gas

08.08 Vic-Check Valves

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

MODEL LP 225LP2 225LP4 Safety Relief Valves

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

orlando OWNER S MANUAL

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

Commercial Hot Water. Make a difference...

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Cased/Uncased Coils For Gas And Oil Furnaces

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Light Duty Commercial Electric Water Heater

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

PREPIPED LIQUID FUEL MANIFOLDS PLPM

Gas Valves. Thermocouples. Pilots. Thermopiles. Water Heating WH/HVAC PRODUCT INFORMATION

6 Crankcase Ventilation

QuickSpecs. HP 480/277 Volt Solutions. Overview

Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

Commercial Gas Furnace Upflow

Churrasco/Grill Manual Models: 2ft, 3ft, 4ft, 5ft & 6ft (with or without motor driven spits)

Electric & Gas Water Heaters

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

37E73A-903 & 906 INTELLI-VENT

3DLevelScanner II TECHNICAL DATA SHEET

API Flanged Safety Relief Valves Series 526 CATALOG

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Gas Water Heater

Installation. Professional Built-in Gas Rangetops VGRT736, CVGRT736, VGRT748, CVGRT748

MODEL J SERIES CONVERTER

UDSA - UDSBD unit heater

C18 ACERT Fire Pump Tier bkw/ rpm

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

1805 Series Relief Valves

Ingersoll Rand. Heat-Of-Compression Air Dryers

Incorrect use or failure of pressure regulators

HOT WATER SYSTEMS.

F9MXE. Product Specifications

Baumann Little Scotty Bronze Control Valve

E-gas Instant Gas Water Heaters

Accessories SUNNY REMOTE CONTROL

36T Series Snap-Action Temperature Controls

Air Eliminators and Combination Air Eliminators Strainers

USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger

Owner s Guide and Installation Instructions

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Transcription:

Product Bulletin Issue Date March 5, 2013 H15 Series BASO Automatic Shutoff Pilot Gas The H15 Series pilot valves provide safe lighting and complete shutoff of pilot and main burner gas in the event that the flame heating the thermocouple is extinguished. They are designed for standing pilot applications and can be used with natural gas and Liquefied Petroleum (LP) gas, at pressures up to 0.5 psi (35 mbar [3.5 kpa]). Typical applications include commercial cooking equipment, heaters, kilns, dishwashing equipment, industrial ovens, and similar applications. In addition to U.S. and Canadian certifications, the H15 models without a rotor B valve are CE Certified. Figure 1: H15 Automatic Pilot Compact Design Safe Lighting Reliable Easy Operation Features and Benefits Permits installation in dimensionally restricted applications Allows gas flow only to the pilot burner during lighting Proven by thousands of units in service Provides simple lighting with use of large reset button Approved Worldwide (Models without Rotor B Only) Broadens applications to include global markets 2013 BASO Gas Products 1 Code. BASO-PB-H15, Rev. D www.baso.com

Application The H15 series automatic pilot valves provide safe lighting and complete shutoff of pilot and main burner gas. They are designed for standing pilot applications and can be used with natural gas, LP gas, or LP gas-air mixtures at pressures up to 0.5 psi (35 mbar [3.5 kpa]). Models without a rotor B valve are suitable for operation over a temperature range of -30 to 175 F (-34 to 79 C). Models with a rotor B valve are suitable for operation over a temperature range of 32 to 175 F (0 to 79 C). The H15_B and H15_R models are suitable for operation over a temperature range of 32 to 300 F (0 to 149 C). The use of single function components provides maximum flexibility in manifold makeup. By combining the H15 pilot valve with other single function components (pressure regulator, automatic gas valve, and manual valve), you can meet the exact requirements of a wide variety of applications. Gas Supply Description H15 valves are 100% shutoff devices with compact, cast aluminum valve bodies. A rotor B valve is provided as an option for manual adjustment of the pilot flame (Figure 3). The flow interruption feature allows gas to flow only to the pilot during the lighting operation. Mounting You may mount the H15 valves in any convenient position. Shutoff 3 in. (72.6 mm) Sediment Trap Pilot Burner Gas Line Rotor B Reset Button Thermocouple Lead indicates possible locations for other controls. Shutoff Plug Reset Button indicates possible locations for other controls. Figure 3: Internal Pilot Gas Flow and Rotor B Installation Gas Supply 3 in. (76.2 mm) Sediment Trap Pilot Burner Gas Line Thermocouple Lead Figure 2: Internal Pilot Gas Flow Installation Shutoff Optional B Reset Button indicates possible locations for other controls. Thermocouple Lead 3 in. (76.2 mm) Sediment Trap Pilot Burner Gas Line Figure 4: External Pilot Gas Flow Installation 2 H15 Series BASO Automatic Shutoff Pilot Gas Product Bulletin

Dimensions A B Top View C Side View Figure 5: Internal Pilot Gas Dimensions Table 1: Internal Pilot Gas Dimensions Product A Maximum Length B Maximum Width C Maximum Height Number in. mm in. mm in. mm H15AA 2.95 75 2.22 56.4 3.50 89 H15AB 2.95 75 2.22 56.4 3.50 89 H15CA 3.17 80.5 2.25 57 3.93 100 H15CB 3.17 80.5 2.25 57 3.93 100 H15DA 3.17 80.5 2.25 57 3.93 100 H15DB 3.17 80.5 2.25 57 3.93 100 H15FA 3.50 89 2.69 68 4.65 118 H15QB 2.53 64 2.56 65 3.53 90 B C IN OUT Top View A Side View Figure 6: Internal Pilot Gas with Rotor B Dimensions Table 2: Internal Pilot Gas with Rotor B Dimensions Product A Maximum Length B Maximum Width C Maximum Height Number in. mm in. mm in. mm H15CH 3.36 85.2 1.84 47 3.76 95.5 H15DH 3.36 85.2 1.84 47 3.76 95.5 H15 Series BASO Automatic Shutoff Pilot Gas Product Bulletin 3

C B Top View A Side View Figure 7: External Pilot Gas Dimensions Table 3: External Pilot Gas Dimensions Product A Maximum Length B Maximum Width C Maximum Height Number in. mm in. mm in. mm H15AR 2.95 75 2.25 57 3.550 89 H15CQ 3.00 76 2.59 66 3.93 100 H15DQ 3.00 76 2.59 66 3.93 100 H15EQ 3.50 89 3.00 76 4.30 109.3 H15FQ 3.50 89 2.69 68 4.65 118 H15HQ 2.53 64 2.56 65 3.53 90 H15HR 2.53 64 2.56 65 3.53 90 H15QR 2.53 64 2.56 65 3.53 90 4 H15 Series BASO Automatic Shutoff Pilot Gas Product Bulletin

Ordering Information H 1 5 - Customer-Specific Requirements Letter *A= *B= H= *Q= *R= Rotor B Yes Power Unit Standard High Temperature Standard Standard High Temperature Pilot Gas Flow Internal Internal Internal External External Natural Gas Capacity Btu/hr at 1 in. W.C. (2.5 mbar [0.25 kpa]) Pressure Drop Letter Btu/hr kw Inlet/Outlet A (A,B)= A (R)= C= D= E= F= H= Q (R)= Q (B)= 160,000 163,000 322,000 335,000 480,000 610,000 160,000 93,000 104,000 47 48 94 98 144 179 47 27 30 3/8 x 3/8 in. NPT 3/8 x 3/8 in. NPT 1/2 x 1/2 in. NPT 3/4 x 3/4 in. NPT 3/4 x 3/4 in. NPT 1 x 1 in. NPT 3/8 x 3/8 in. NPT 1/4 x 1/4 in. NPT 1/4 x 1/4 in. NPT *Indicates CE Certified. The presence of a particular construction in this information does not guarantee its availability. Consult BASO Gas Products for available constructions. Figure 8: Ordering Matrix H15 Series BASO Automatic Shutoff Pilot Gas Product Bulletin 5

Technical Specifications Product Rated Inlet Pressure Body Recommended Thermocouple Lead Lengths Permissible Ambient (Surface) Temperature Inlet and Outlet Body Connections H15 Series BASO Automatic Shutoff Pilot Gas 0.5 psi (35 mbar [3.5 kpa]) Aluminum K15: 12 to 48 in. (305 to 1,220 mm) K16: 12 to 72 in. (305 to 1,830 mm) K19: 18 to 72 in. (457 to 1,830 mm) -30 to 175 F (-34 to 79 C) models without rotor B valve 32 to 175 F (0 to 79 C) models with rotor B valve 32 to 300 F (0 to 149 C) H15_B and H15_R models only 1/4, 3/8, 1/2, 3/4, or 1 in. NPT Torsion Group Group 2 (EN 125) Gas Classification Class B (EN 125) Types of Gas Packaging Bulk Pack Quantity Bulk Pack Weight Agency Listing Specification Standards Natural, Liquefied Petroleum (LP), and LP gas-air mixtures Bulk pack supplied to original equipment manufacturer (individual pack optional) 20, 30, 32, and 40 (depending on valve size) 24 to 42 lb (11 to 19 kg) CSA Certificate Number 229521-1656080 Australian Gas Association Certificate Number 4236 (Specific models without rotor valve only) AGA Class 1, Type Flame Safeguard (excludes H15Q_ and H15_B) EC Type Examination Certificate Number E0485 (excludes models with rotor B valve, H15E_, and H15Q_) UL File Number MH2926 (H15CA, CH, and DA models only) ANSI Z21.20, CAN1-6.4 ANSI Z21.21, CSA 6.5 ANSI Z21.78, CSA 6.20 AS 4620 EN 125 UL Standard 372 Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products. Refer to the H15 Series BASO Automatic Shutoff Pilot Gas Installation Instructions (Part. BASO-INS-H15) for necessary information on the installation, use, and servicing of this product. 1007 South 12th Street PO Box 170 Watertown, WI 53094 www.baso.com 1-877-227-6427 (1-877-BASOGAS) Published in U.S.A. 6 H15 Series BASO Automatic Shutoff Pilot Gas Product Bulletin