3512C Land Drilling Generator Set

Similar documents
C18 ACERT Fire Pump Tier bkw/ rpm

3516 Industrial Engine

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

How To Use A Cat Diesel Engine

3516B Offshore Generator Set

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

3516B Offshore Emergency Generator Set

C18 Diesel Oilfield Generator Set

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

DIESEL GENERATOR SETS

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Technical Specification. Generating Set with Waukesha engine burning natural gas

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Diesel Engine Driven Generators Page 1 of 6

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Spark-ignited generator set

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Annex-A TECHNICAL SPECIFICATION

INDUSTRIAL ENGINE RATINGS GUIDE

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Diesel Generating Set

Diesel Generator Set Model DFHC 60 Hz

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

Diesel Generator Set Model DFMB 60 Hz

Diesel Generator Set Model DGDK 60 Hz

How To Control A Power Command Powerplant

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Magnum Mobile Generator MMG55 Specifications

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Centro-Matic Automatic Lubrication Systems System Controls

Marine Generating Sets 3.7 to 50 kva

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

X G R E N T A L

New 27 hp 2 Cylinder Liquid-Cooled Engine

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E DIESEL ENGINE CONTROL SYSTEMS

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

300 Series PA Pump and Cooler Assemblies

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

1013 E. The engine for agricultural equipment.

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Signature and ISX CM870 Electronics

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

The Yachtmans Choice...

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

912. The engine for construction equipment.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

OFFSHORE POWER. Caterpillar Global Petroleum

Cooling system components, removing and installing

Diagnostic Fault Codes For Cummins Engines

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

LOAD BANK TESTING PROCEDURE

D6R Series III Track-Type Tractor

REMOVAL AND INSTALLATION

Atlas Copco Generators

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

IGSA POWER GENERATION SYSTEMS

1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED

6 Crankcase Ventilation

Kobelco Extended Warranty Program.

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Auxiliary Power Unit (APU) for Military Vehicles

APS100 Rental Generator Set Specification

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

HEAVY-DUTY, REDEFINED. REDEFINED.

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Hydraulic Control Solutions

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

CAT CG132. Series Gas Generator Sets

Single-Phase AC Synchronous Generator

Medical Air Systems: Scroll

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Process Alarm Solutions

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

SELECTION, APPLICATION & MAINTENANCE

Parts Catalog For Nordco Engine (JD 4045TF270)

Rotary screw compressors kw 5,5 7, , bar MODULO

Section 10 Maintenance Specifications

How To Use A Ds340 (Dsp)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Transcription:

Land Drilling Generator Set 1045 ekw (1492 kva) 1101 bkw (1476 bhp) 60 Hz (1200 rpm) Image shown with optional attachments. CAT GENERATOR SET SPECIFICATIONS V-12, 4-Stroke-Cycle-Diesel Emissions... Non-current EPA Tier 2 Bore... 170 mm (6.69 in) Stroke... 190 mm (7.48 in) Displacement... 52 L (3158 in 3 ) Aspiration... Turbocharged-Aftercooled Fuel System... EUI Engine Control and Protection... ADEM A3 Generator... SR4B Voltage...600 Generator Set Control... EMCP 4.3 Note: Power rating does not include radiator fan power. FEATURES Product Design - Developed specifically to meet the demands of oil and gas applications - Latest electronics for enhanced safety, performance, and user interface - Proven reliability and durability - Robust base design for high durability and ideal for loading/unloading operations - Market-leading power density - Rugged, oversized cooling system for 50 C ambient capability at rated power - Long overhaul life proven in oilfield applications - Core engine components designed for reconditioning and reuse at overhaul Ease of Installation - Inner-outer base mounting configuration simplifies rig integration - Wide range of attachments enable configuration flexibility - Inner base three-point generator mounting maintains factory alignment - Single lifting point simplifies installation work Safety - E-stop pushbutton on instrument panel - Air shutoff and explosion relief valves available - Configurable alarm, derate, and shutdown set points - Extra alarms, inputs, and outputs available Custom Packaging For any petroleum application, trust Caterpillar to meet your exact needs with a factory custom package. Cat engines, generators, enclosures, controls, radiators, transmissions anything your project requires can be custom-designed and matched to meet any project requirement. Custom packages are globally supported and are covered by a one-year warranty after startup. Testing - Every Cat generator set is full-load tested to ensure proper engine performance. - Standard configurations are assembled, tested, and validated as a package to ensure performance, reliability and durability. Product Support Offered Through Global Cat Dealer Network - More than 2,200 dealer outlets - Cat factory-trained dealer technicians service every aspect of your Cat petroleum product - Worldwide parts availability, service, and warranty - Preventive maintenance agreements available for repairbefore-failure options - S O S SM program matches your oil and coolant samples against Caterpillar set standards to determine: Internal engine component condition Presence of unwanted fluids Presence of combustion by-products Site-specific oil change interval Over 80 Years of Engine Manufacturing Experience Ownership of these manufacturing processes enables Caterpillar to produce high quality, dependable products. Web Site For all your petroleum power requirements, visit www.catoilandgasinfo.com. LEHW0068-01 Page 1 of 6

CONFIGURATION Air Inlet System Corrosion-resistant aftercooler core Air inlet shutoff Air cleaner options: *Regular duty Heavy duty + Remote air inlet adapter rectangular + Remote air inlet adapter round Control System ADEM A3 ECU, left-hand mounted Engine control options: *Direct rack control 0-200 madc, space heater and jacket water heater connection and controls Cat DVR control, includes reactive droop capability, 3-phase voltage sensing, kvar/pf modes, RFI suppression, min/max exciter limiter and exciter diode monitor, space heater and jacket water heater connection and controls Direct rack control 0-200 madc with 6 stator RTDs, 2 bearing RTDs, space heater and jacket water heater connection and controls Cat DVR control, includes reactive droop capability, 3-phase voltage sensing, kvar/pf modes, RFI suppression, min/max exciter limiter and exciter diode monitor, space heater and jacket water heater connection and controls, 6 stator RTDs, 2 bearing RTDs + Load sharing governor, 2301A Cooling System Separate-circuit aftercooled Outlet controlled jacket water thermostat Jacket water pump gear driven Dual outlet Aftercooler water pump gear driven Aftercooler water thermostat Radiator options: *Caterpillar supplied radiator, 46/CVS-stacked 0.627 ratio, includes blower fan, fan drive, pulley, belt guard, coolant level sensor, regulator, and fuel cooler Remote cooling connection RH Remote cooling connection LH Customer-provided radiator Custom radiator Cooling system connection options (for use with customersupplied radiator): Dual outlet coupling-type connections Dual outlet hose and clamp-type connections Fan drive and belt guard (for use with remote and customersupplied radiators) Fan pulley options (for use with customer-supplied radiator): Front stub shaft Front stub shaft with 197 mm pulley Front stub shaft with 248 mm pulley Custom + Coolant level sensor + Coolant conditioner Exhaust System Dry exhaust manifold Dual turbochargers, water cooled bearings Exhaust expander options: Exhaust expander 297 mm to 340 mm (11.7 in to 13.4 in) *No exhaust expander included Flexible exhaust fitting options: Flexible fitting, 356 mm (14 in) *No flexible fitting included + Elbow, 305 mm (12 in) + Muffler, 356 mm (14 in), spark arresting, includes companion flanges, clean-out box, and spark box + Muffler, 305 mm (12 in), spark arresting, includes companion flanges, clean-out box, and spark box Flywheel and Housing SAE No. 00 flywheel SAE No. 00 flywheel housing SAE standard rotation Fuel System Fuel transfer pump Fuel return line with flexible connection Electronic unit injectors Fuel filter options: *Fuel filter simplex (LH) with priming pump (LH) Custom fuel filter + Primary fuel filter + Primary fuel filter with water separator Generator Attachments Generator terminal box options: Barrel-mounted petroleum terminal box Barrel-mounted petroleum terminal box with air filter and pressure differential switch + Current transformers (3) + Cable access box Instrumentation Emergency stop button Analog gauges: Fuel pressure Engine oil pressure Engine oil temperature Engine coolant temperature DC voltage Engine percent load EMCP 4.3 control panel 5.5 inch graphical display 16 languages supported Engine/generator monitoring and protection CAN, RS 485 MODBUS, Ethernet communications supported Remote e-stop/start/stop Engine start and crank attempt counter Thermocouple options: Thermocouples installed, one per cylinder *No thermocouples included *Denotes which option is included in the standard configuration + Optional attachment LEHW0068-01 Page 2 of 6

CONFIGURATION (continued) Service port connector Customer connection terminal blocks + Communications module PL1000T + Communications module PL1000E Lubrication System Crankcase breather Oil cooler Shallow oil pan Oil drain extension, 2 in NPT female connection Oil filter options: *Simplex oil filter Custom oil filter Centrifugal oil filter options: RH installed centrifugal oil filter *No centrifugal oil filter included Lubricating oil options: SAE15W40, Caterpillar DEO, 500 hour *No lubricating oil included + Crankcase fumes disposal + Oil level regulator Mounting System Inner base options: *4.19 m (165 in) length, 412 mm (16.2 in) height tubes, 1.18 m (50.5 in) wide Custom base Outer base options: *No outer base included Custom outer base + Package isolator supports (3), for mounting inner base to customer-supplied base Power Take-off Charging alternator options *No alternator Alternator, 24V, 68A Protection System Alarms: ECU voltage Oil pressure Low/high water temperature Overspeed Crankcase pressure Aftercooler temperature Low water level (optional) Air inlet restriction Exhaust stack temperature Oil/fuel filter differential pressure Derate: High water temperature Crankcase pressure Aftercooler temperature Air inlet restriction Exhaust temperature Shutdown: Oil pressure Low/high water temperature Overspeed Crankcase pressure Aftercooler temperature Explosion relief valve options: Explosion relief valves (3) *No explosion relief valves + Metal particle detector switch + Metal particle detector with annunciator Starting System Starting motor options: *TDI air starting motor, RH 1034 kpa (150 psi) Custom starting motor + Air pressure regulator General Barring group options: LH installed engine barring group *No barring group included Jacket water heater options: Jacket water heater, UL recognized, 120-240V, single phase, 6 kw, LH and RH mounted Jacket water heater, UL recognized, 120-480V, single phase, 12 kw, LH and RH mounted *No jacket water heater included + Jacket water heater lines *Denotes which option is included in the standard configuration + Optional attachment LEHW0068-01 Page 3 of 6

TECHNICAL DATA 3512C Land Drilling Generator Set 1200 rpm Units DM8320 Generator Set Data Rated power ekw 1045 kva rating kva 1492 Rated power factor 0.7 Frequency Hz 60 Engine Data Engine power bkw (bhp) 1101 (1476) Engine speed rpm 1200 Max. altitude without derate m (ft) 2700 (8858) BMEP kpa (psi) 2127 (308) BSFC @ 100% load g/bkw-hr (lb/bhp-hr) 200 (0.33) BSFC @ 75% load g/bkw-hr (lb/bhp-hr) 205 (0.34) BSFC @ 50% load g/bkw-hr (lb/bhp-hr) 214 (0.35) BSFC @ 25% load g/bkw-hr (lb/bhp-hr) 237 (0.39) Fuel consumption (nominal) L/hr (gal/hr) 262.9 (69.5) Air flow rate (@25 C, 101.3 kpa) m 3 /min (ft 3 /min) 93.4 (3298) Inlet manifold pressure kpa (psi) 253.7 (36.8) Inlet manifold temperature C ( F) 58.1 (136.6) Aftercooler water temperature C ( F) 50 (122) Jacket water temperature C ( F) 99 (210) Exhaust stack temperature C ( F) 397.6 (748) Exhaust flow rate (@ stack temp, 101.3 kpa) m 3 /min (ft 3 /min) 218 (7699) Lube oil system capacity L (gal) 318 (84) Engine coolant capacity L (gal) 157 (41) Radiator coolant capacity (JW) L (gal) 284 (75) Radiator coolant capacity (AC) L (gal) 197 (52) Oil change interval Hours 500 Generator Data Frame size 867 Efficiency 95% Voltage Volts 600 Design kva rating kva 1750 Insulation class H Temperature rise (@ 40 C ambient temp) C 80 Coastal protection Included Excitation PM or SE Number of poles 6 Winding Form wound Pitch 0.7333 Number of leads 6 Number of bearings 2 Ingress protection (IP) rating 23 Alignment Close coupled Space heater W 1200 RTDs per phase 2 RTD resistance Ohm 10 LEHW0068-01 Page 4 of 6

altitude and ambient deration factors 10 C 20 C 30 C 40 C 50 C 0 m 1.00 1.00 1.00 1.00 1.00 300 m 1.00 1.00 1.00 1.00 1.00 500 m 1.00 1.00 1.00 1.00 1.00 1000 m 1.00 1.00 1.00 1.00 1.00 1500 m 1.00 1.00 1.00 1.00 1.00 2000 m 1.00 1.00 1.00 1.00 0.97 2500 m 1.00 1.00 0.97 0.94 0.91 3000 m 1.00 0.94 0.91 0.88 0.85 3500 m 1.00 0.88 0.85 0.82 0.80 4000 m 0.86 0.83 0.80 0.77 0.75 4500 m 0.80 0.77 0.75 0.72 0.70 EMCP 4.3 FEATURES 140 mm (5.5 in) Graphical Display Generator AC voltage 3-phase (L-L & L-N) ± 0.25% accuracy rpm and battery voltage Generator AC current (per phase and average) Generator frequency Power metering (kw, kva, kvar, pf) Hour meters (kw-hour, kvar-hour) Engine oil pressure (psi, kpa or bar) Engine oil temperature ( C or F) Engine coolant temperature ( C or F) Multiple language support Engine start and crank attempt counter Real time clock Communication Accessory CAN data link RS-485 annunciator data link RS-485 SCADA (Modbus RTU) Ethernet SCADA (Modbus TCP) Controls Auto/start/stop Engine cooldown timer Emergency stop Engine cycle crank Programmable cycle timer Generator Set Protection Over/under voltage Over/under frequency Generator phase sequence Over current (timed and inverse) Reverse kw, kva Current balance Low oil pressure High coolant temp Low coolant level Fail to start Overspeed Outputs 16 programmable digital outputs 3 programmable (4-20mA or ±10V) 2 programmable (PWM) Inputs Emergency stop Remote start 12 programmable digital inputs Oil pressure and water temperature 3 programmable inputs (±10V, PWM, current, or resistive) Oil temperature, fuel level Other Features 16 languages supported: - Arabic - Greek - Chinese - Italian - Danish - Japanese - Dutch - Portuguese - English - Russian - Finnish - Spanish - French - Swedish - German - Turkish Programmable security levels Reduced power mode Programmable kw relay Cat switchgear integration Status event log LEHW0068-01 Page 5 of 6

land DRILLING generator set 2659 mm 104.7 in 6051 mm 238.2 in 2318 mm 91.2 in Generator Set Dimensions Length 6051 mm 238.2 in Width 2318 mm 91.2 in Height 2659 mm 104.7 in Weight 14 453 kg 31,864 lb * Generator set weight is dry and includes engine, generator, and base. Note: Do not use for installation design. See installation drawing for details. RATING definitions and CONDITIONS Performance is obtained and corrected in accordance with ISO 3046/1. Reference atmospheric inlet air: 100 kpa (29.61 in Hg), 25 C (77 F), 30% relative humidity at stated aftercooler temperature. Performance is also in accordance with SAE J1995, BS5514/1, and DIN6271/1 standard reference conditions, Reference fuel: #2 distillate diesel with a 35 degree API gravity, lower heating value is 42 780 kj/kg (18,390 Btu/lb) when used at 29 C (84.2 F), where the density is 838.9 g/l (7.001 lb/gal). Engines are equipped with standard accessories; lube oil pump, fuel pump, aftercooler water pump, and jacket water pump. The power required to drive auxiliaries must be deducted from the gross output to arrive at the net power available for the external (flywheel) load. Typical auxiliaries include cooling fans, air compressors, and charging alternators. Power tolerance is +/- 5% Exhaust stack temperature tolerance is +/- 8% Inlet airflow rate tolerance is +/- 5% Intake manifold pressure tolerance is +/- 10% Exhaust flow rate tolerance is +/- 6% Fuel rate tolerance is +/- 5% Heat rejection tolerance is +/- 5% Exhaust heat rejection tolerance is +/- 10% Wet exhaust mass flow rate Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, EUI, S O S, Caterpillar Yellow and the Power Edge trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. Performance Number: DM8320-00 2013 Caterpillar LEHW0068-01 (2-13) All rights reserved.