Omnigrad S TMT142R. Technical Information. Compact RTD assembly Temperature transmitter for for resistance thermometers, adjustable via HART protocol

Similar documents
Technical Information RIA14

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Digital display DA 48

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Contents. Document information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Technical Data. Dimensions

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Plastic tube flowmeters Series PT/PS

Software and Display instruments

Omnigrad S TR66. Technical Information. Modular RTD assembly, flameproof Bar stock-thermowell, with thread or flange

Rosemount 644 Temperature Transmitter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Electronic Flow Switches

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

COMBIMASS. Technical Data COMBIMASS eco-bio +

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Microcor Wireless Transmitter (MWT)

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Flow switches Series AD/VH

Wahl C50 Calibrator FEATURES

Test equipment for temperature and its reduction

Inductive sensor NI10-M18-Y1X-H1141

Measuring Temperature withthermistors a Tutorial David Potter

ph/redox Measurement MyPro CPM 431

TEIP11 I/P signal converter for standard signals. Measurement made easy

PRODUCT PROFILE FEATURES

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

T0118 T2118 T3118. Instruction Manual

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Control- and feedback head for integrated mounting on Robolux valves Type 2036

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Operating instructions. itemp PCP TMT181. Temperature head transmitter. BA100R/24/ae/

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Temperature Transmitters ZTT series

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

J TB/TW Temperature limiter, temperature monitor

Hand-held thermometer Model CTH7000

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Rosemount 333 HART Tri-Loop

How To Use A Ds340 (Dsp)

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Type testing

PC BASED PID TEMPERATURE CONTROLLER

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DeltaV S-series Traditional I/O

Capteur température et humidité pour HVAC

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

USB-500/600 Series Low-Cost Data Loggers and Accessories

3DLevelScanner II TECHNICAL DATA SHEET

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems

Sanitary Type Electronic Flow Switches

Instruction Manual. T3111 T3111L T3111P T3111Ex

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Thermometer in stainless steel with capillary and switch contacts

MINI MCR-SL-R-UI(-SP)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Rosemount 333 HART Tri-Loop

Temperature Accuracy of Thermistors and RTDs Application Notes

Basic RTD Measurements. Basics of Resistance Temperature Detectors

MLC TM Maximum Productivity and Versatility for Control without Compromise!

USB-500 Series Stand-Alone, Low-Cost Data Loggers

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

TTH300 Head-mount temperature transmitter

4-Channel Thermometer / Datalogger

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Reliability Accuracy Performance

NEW. EVEN MORE data acquisition and test stand automation

S300 Series Dust Monitors

Pressure transmitter For general industrial applications Model A-10

Microcontroller to Sensor Interfacing Techniques

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

MOUNTING AND OPERATING INSTRUCTIONS

Impedance 50 (75 connectors via adapters)

SITRANS F flowmeters SITRANS F M

PROCESS AUTOMATION MANUAL. Universal Temperature Converter. KFD2-UT2-(Ex)*(-1) ISO9001

Operating instructions. itemp HART TMT162. Temperature field transmitter. BA132R/24/ae/12.06 Device software

Duct Humidity Transmitter

USB-500 Series Low-Cost Data Loggers and Accessories

Rosemount 248 Temperature Transmitter

For Multi-Parameter Meters see mvx

Transcription:

Technical Information Omnigrad S TMT142R Compact RTD assembly Temperature transmitter for for resistance thermometers, adjustable via HART protocol Application The temperature assembly TMT142R from the Omnigrad S family is a compact resistance thermometer specifically designed to fulfill the requirements of different process industries such as the chemical, petrochemical and energy but even suitable to other general purpose applications. The thermometer assembly TMT142R consists of a temperature RTD sensor insert (Pt 100) and an electronic two-wire temperature transmitter providing a 4 to 20 ma output, configurable via HART protocol. Thanks to the versatility of its product structure, the TMT142R is easily adaptable to various applications in many different industrial processes. Your benefits HART protocol for operating the device on site using handheld terminal (DXR375) or remotely via the PC Illuminated display, rotatable Operation, visualization and maintenance with PC, e.g. using FieldCare or ReadWin 2000 operating software Pt 100 sensing element with class A accuracy (IEC 60751) or class1/3 DIN B Pt 100 wire wound for use in temperature range -200 to 600 C (-328 to 1112 F) Single Pt 100 with 3 or 4 wires connection Undervoltage detection responds immediately, output of falsified measured values is prevented Highly accurate in entire operating temperature range Sensor monitoring: Failure conditioning, corrosion detection to NAMUR NE 89; Failure conditioning in event of sensor break or sensor short-circuit, adjustable to NAMUR NE 43 EMC to NAMUR NE 21, CE Aluminum or stainless steel (optional) housing with IP67 or NEMA 4x ingress protection degree Calibration certificate can be ordered together with the assembly Output simulation Min./max. process value recorded Customized measuring range setup or expanded SETUP, see questionnaire Approvals: ATEX (EEx ia, EEx d and dust ignitionproof), CSA (IS, NI, XP and DIP) 0 1 TI128R/09/en 71022415

HELP I O TMT142R Function and system design Measuring principle In the RTD thermometer (Resistance Temperature Detector) the sensing element is an electric resistor with a 100 Ohm resistance value at 0 C (so called Pt 100, according to the IEC 60751 standard norm). The resistance value of a Pt 100 increases with temperature, depending on the physical characteristic of the used material (platinum). In the industrial thermometers, according to the standard IEC 60751, the thermal coefficient of the Pt 100 platinum sensors is = 3.85*10-3 C -1, in the range between 0 C to 100 C. Measuring system FieldCare, ReadWin 2000 RN221N Commubox TMT142R, TMT142C PMC731: PIC0001 Online 1 >Group Select 2 PV 0.7 bar DXR375 HART Communication Example of an application of the compact thermometer The Omnigrad S HART TMT142R is a compact thermometer with a two-wire transmitter and an input for resistance thermometers in 3-wire or 4-wire connection, and an analog output. The LC display shows the current measured value digitally and as a bar graph with an indicator for limit value violation. The TMT142R can be operated via the HART protocol using a handheld terminal (DXR375) or PC (FieldCare or ReadWin 2000 operating software). The sensor construction is based on the IEC 60751 standard, giving high reliability and performance in all the typical industrial environment conditions. The Pt 100 sensing element is a wire wound type (WW) and is placed in tip of the sensor. The measuring probe (RTD replaceable insert) is installed in a thermowell. Thanks to the spring load construction method, the sensing element is always in contact with the inner tip of the thermowell in order to guarantee the best heat transfer from the process to the sensing element. The transmitter housing is available either in coated aluminum or stainless steel (optional), with or without LC display. The fit between housing, thermowell and cable gland ensures a minimum IP65 (Ingress Protection) grade. The thermowell can be either welded or made from bar-stock material. The thermowells are available in different forms and with many process connections: threads, flanges or weld-in types (see the paragraph Thermowell ). Corrosion detection Sensor connection line corrosion can corrupt the measured value. For this reason, the device gives you the opportunity to detect corrosion for thermocouples and resistance thermometers with a 4-wire connection before measured value corruption takes place. 2 Endress+Hauser

Input Measured variable Measuring range Type of input Temperature (temperature linear transmission behavior) The transmitter records different measuring ranges depending on the sensor connection and input signals (see 'Type of input'). Input Designation Measuring range limits Min. span Resistance thermometer (RTD) to IEC 751 ( = 0.00385) -200 to 850 C (-328 to 1562 F) to JIS C1604-81 ( = 0.003916) to DIN 43760 ( = 0.006180) -200 to 649 C (-328 to 1200 F) to Edison Copper Winding No.15 ( = 0.004274) to SAMA ( = 0.003923) to Edison Curve ( = 0.006720) to GOST ( = 0.003911) to GOST ( = 0.004278) (Callendar - van Dusen) -100 to 700 C (-148 to 1292 F) -200 to 850 C (-328 to 1562 F) -200 to 850 C (-328 to 1562 F) Type of connection: 3- or 4-wire connection With 3-wire and 4-wire connection, sensor wire resistance to max. 50 per wire Sensor current: 0.3 ma Response time Self heating Tests in water at 0.4 m/s (according to IEC 60751; 23 to 33 C step changes), without thermowell t50: 2.5 s t90: 7 s Negligible Endress+Hauser 3

Output Output signal Signal on alarm Load Linearization/transmission behavior Filter Galvanic isolation Input current required Current limit Switch-on delay Analog 4 to 20 ma, 20 to 4 ma Underranging: Linear drop to 3.8 ma Overranging: Linear rise to 20.5 ma Sensor break; sensor short-circuit: 3.6 ma or 21.0 ma (configurable 21.6 ma to 23 ma) Max. (V power supply - 11 V) / 0.022 A (current output) Temperature linear, resistance linear, voltage linear 1 st order digital filter: 0 to 60 s U = 2 kv AC (input/output) 3.5 ma 23 ma 4 s (during switch-on operation I a = 4 ma) Power supply Electrical connection Supply voltage Cable entry Residual ripple U b = 11 to 40 V (8 to 40 V without display), reverse polarity protection Warning! Power must be fed to the device from an 11 to 40 VDC power supply in accordance with NEC Class 02 (low voltage/current) with short-circuit power limit to 8 A/150 VA. See "Product structure" Perm. residual ripple U ss 3 V at U b 13.5 V, f max. = 1 khz 4 Endress+Hauser

Accuracy Response time Reference operating conditions Maximum measured error 1 s per channel Calibration temperature: +25 C ± 5 K (77 F ± 9 F) Maximum error of the Pt 100 (WW) sensing element Ê Cl. A 3 = 0.30+0.0050ItI -200 to 600 C (-328 to 1112 F) Ê Cl. 1/3 DIN B 3 = 0.10+0.0017It -50 to 250 C (-58 to 482 F) 3 = 0.30+0.0050ItI -200 to -50 / 250 to 600 C (-328 to -58/482 to 1112 F) (ItI=absolute value of the temperature in C) Transmitter maximum measured error Designation digital Accuracy D/A Resistance thermometer (RTD) 0.2 K 0.1 K 1 0.02% 1) Only with the "Advanced Electronics" option Physical input range of the sensors 10 to 400 Repeatability 0.03% of the physical input range (15 Bit) Resolution A/D conversion: 18 Bit With the "Advanced Electronics" option: 0.015% of the physical input range (16 Bit) Influence of supply voltage Long-term stability ±0.005%/V deviation from 24 V, related to the full scale value 0.1 K/year or 0.05%/year Data under reference conditions. % relates to the set span. The larger value applies. Endress+Hauser 5

Remote operation Configuration see Operating elements Interface HART communication via transmitter power supply (e.g. RN221N; see 'Measuring system'). Configurable device parameters (selection) Sensor type and type of connection, engineering units ( C/ F), measuring ranges, internal/external cold junction, compensation of wire resistance with 2-wire connection, failure mode, output signal (4 to 20/20 to 4 ma), digital filter (damping), offset, TAG+descriptor (8+16 characters), output simulation, customized linearization, recording of min./max. process value, analog output: channel 1 (C1) Option: customized linearization Certificates and approvals CE mark Ex approval Other standards and guidelines The device meets the statutory requirements of the EC directives. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. Information about currently available Ex versions (ATEX, FM, CSA, etc.) can be supplied by your E+H Sales Center on request. All explosion protection data are given in a separate documentation which is available upon request. IEC 60529: Degrees of protection through housing (IP code) IEC 61010: Protection measures for electrical equipment for measurement, control, regulation and laboratory procedures IEC 1326: Electromagnetic compatibility (EMC requirements) NAMUR Association for Standards for Control and Regulation in the Chemical Industry 12 Endress+Hauser