QUADRANT Engineering Plastic Products. MediTECH Product Line implantable grade UHMW-PE. ARP Programme. Stefan Willing, QUADRANT

Similar documents
The information contained in this document is intended for healthcare professionals only.

Outline of a quality system and standard for the certification of conformity

Effect of Sterilization Techniques on Polymers

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Medical Device Packaging and Sterilization: What you need to know to protect your product

Products. EschmannStahlGrades Plastic Mould Steel Hot Work Tool Steel Cold Work Tool Steel Overview

NAN YA NYLON 66 Engineering Plastics. Flame Retardant.High Toughness.Heat Resistant. Impact Resistant.Moldability.Low Warpage

Polyolefin Heat Shrink Tubing for Tight-Tolerance Medical Applications

Resistance of Plastics to Gamma Irradiation

Gamma Sterilisation Validation according to ISO Sterilising dose -

North American Stainless

3D FUSION NANO POWDER DIRECT METAL SINTERING SYSTEMS SPECIFICATION

i-polymers for i-arthroplasty New Polymer Technologies for HIP Arthroplasty

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

HEALTHCARE Single - Use Systems CONTRACT MANUFACTURING SOLUTIONS PARTNER

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

Session Five: Modern XLPE Materials for Extruded Energy Cable Systems

North American Stainless

Validation of biomedical coatings

Cleanroom Packaging Protect against contamination

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI. GRI Test Method GM21

North American Stainless

Raven and Conductex Products for Specialty Applications

WHY CHOOSE TIMS? ISO9000 /TS certified. Class A Painting Facility. Large Manufacturing and Assembly Space. Competitive pricing

Training: NDT Access Conditions

Development of High-Speed High-Precision Cooling Plate

HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS

Packaging Validation according to ISO 11607

Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth

Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)

T H E E X C E L L E N C E, A P E R M A N E N T RESEARCH

Sinterstation. Pro Direct Metal SLM System

Precision injection moulding

Aviation. ACRYLITE Acrylic Sheet Products for Aircraft Transparencies

Quality Control and Quality Assurance

Metal Injection Molding (MIM) of components made of Titanium and its alloys

White Oils and Soft Paraffins

API Upstream Standard Development Update - Supply Chain Management. Rick Faircloth

Pressure Control Supplier Quality Requirements Nondestructive Testing Services SQ-10 Rev: 1.1

Electron Beam Technology for Pressure Sensitive Adhesive Applications

PROCESSING OF VARIOUS MATERIALS

Seamless stainless tubes for hydraulic and instrumentation systems

North American Stainless

Solution heat treatment facility

PA 1101 & PA 1102 black Impact-Resistant Plastic Materials Flexible, Chemical- Resistant and Made from Renewable Raw Materials.

You have our undivided attention.

Notes on Polymer Rheology Outline

Why Plastic Flows Better in Aluminum Injection Molds

Good Boards = Results

AS9100 Quality Manual

North American Stainless

North American Stainless

Engineering Plastics Solutions for Food & Dairy Production

Sargent Controls & Aerospace 5675 West Burlingame Rd. Tucson AZ PHONE: (520) FAX: (520)

Demand for more complex products with higher quality and longer life

Understanding Plastics Engineering Calculations

Additive Manufacturing: Processes and Standard Terminology

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

What Boat Captains and Marine Surveyors Should Know about Oils and Oil Analysis

EBM Inside. Additive Manufacturing of orthopedic implants

STAVAX SUPREME. Stainless tool steel

North American Stainless

Cold drawn seamless steel tubes for mechanical applications

GLOBAL MANUFACTURING. ARAUJO, Anna Carla AUG, 2015 Mechanical Engineering Department POLI/COPPE/UFRJ

DEVELOPMENT. Shorter time to market More product variants Increasing design complexity. Rapid. Prototyping PRODUCTION

1.4 Metallic Impurities Iron must not exceed 150 ppm and copper shall not exceed 6 ppm when tested according to TAPPI T 266.

FRIULFORGIA Srl COMPANY PRESENTATION. We shape your world

THERMAL INSULATION ISOCOMPACT

AISI O1 Cold work tool steel

STENCA PIPE. High quality pipe insulation.

Ningbo Yinzhou Keao Prototyping & Mould Factory Services include : CNC machining prototypes,

* This work is an official contribution of the National Institute of Standards and Technology and

FRICTION MATERIALS & BONDING SERVICES

Measurement of Residual Stress in Plastics

Application of Welding Standards in Hong Kong. S. K. Babu Laboratory Manager - Foundation Techniques Ltd

Sterile Cleanroom Management

The Crosslinked Ultra-high Molecular Weight Polyethylene

Automotive Base Oil Presentation

SECTION 1 COMPANY OVERVIEW

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Sterilization methods and equipment Lab 1-2

Best Available Technology for Sodium Hypochlorite Storage Tanks

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Why an Exactech Hip is Right for You

Oil Analysis. It is important that the sampling be done in the following manner: 1.

Dimensional Change Characteristics for Printed Circuit Board Films

LASER CUTTING OF STAINLESS STEEL

Test Methods for the Colour Fastness of Leather & Dyes. TFL Leather Technology Ltd. Quality and Environment February 2004 Version 1.

Verification Experiment on Cooling and Deformation Effects of Automatically Designed Cooling Channels for Block Laminated Molds

ABSTRACT INTRODUCTION

STENCA HT PIPE. Quality Insulation made of calcium silicate.

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

CYROLITE. Sterilization Methods & Considerations. Technical information

Prototyping Process Choosing the best process for your project

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

FlyMe Environmental impact assessment MHI/ Page 1(6) 2 Description and assessment of the Production process

Revision 0 May 22, 2015

Characterization of Polymers Using TGA

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

Transcription:

QUADRANT Engineering Plastic Products MediTECH Product Line implantable grade UHMW-PE ARP Programme Stefan Willing, QUADRANT

QUADRANT MediTECH Medical grade UHMW-PE manufactured and supplied by Quadrant MediTECH as shapes (plate, rod, preforms) to be used in Orthopedics Implants CHIRULEN EXTRULEN PE-UHMW medical grade CHIRULEN EXTRULEN PE-UHMW medical grade

QUADRANT MediTECH: Medical grade UHMW-PE GUR 1020 and GUR 1050 resin (powder) CHIRULEN 1020 and 1050 EXTRULEN 1020 and 1050 Shapes (plates, rods, preforms)

QUADRANT MediTECH: Medical grade UHMW-PE Primary Conversion & Resin Conditioning Post-sintering and Annealing Processes Cross-linking Expertise Blending & Mixing Technology

QUADRANT MediTECH: Medical grade UHMW-PE Compression molding technology: 3 dedicated presses Cleanroom operations (ISO 14644-1, class 8, note: Vreden only) Special mold surface allows elimination of release agent

MediTECH Conversion Technology Fort Wayne Pressing Operation

QUADRANT Engineering Plastic Products Product range of CHIRULEN and EXTRULEN CHIRULEN 1020 CHIRULEN 1050 standard sizes: sheet size sheet thickness rod diameter rod length 1000 mm x 500 mm 20 mm to 80 mm 20 mm to 80 mm 500 mm, 1000 mm EXTRULEN 1020 EXTRULEN 1050 standard diameter 12 mm to 100 mm length 500 mm, 1000 mm, 3000 mm Special sizes, cut-to-size, fabricated preforms upon request

QUADRANT Engineering Plastic Products MediTECH Product Line Typical applications ARP Programme

[Orthopedics - Total Joint Replacement] [Application: artificial hip and knee components] Material [CHIRULEN 1020 and 1050] Processes Properties and benefits: [Compression Molding, Stabilization under N 2 ] Stabilized / annealed under inert atmosphere (N 2 ) High dimensional stability Very high impact strength, excellent sliding properties, very high wear resistance Full traceability for 30 years GMP - Validated Processes Biocompatible, per ISO 5834, ASTM F 648 and USP Class VI requirements Long-term record in Orthopedics (e. g. hip, knee, elbow joint replacements)

[Orthopedics - Total Joint Replacement] [Application: artificial hip and knee components] Material [Crosslinked CHIRULEN 1020/1050] Processes Properties and benefits: [Compression Molding, Stabilization under N 2, Crosslinking process, secondary stabilization process under N 2 ] Improved wear resistance manufactured according to customer specifications cross-linking and stabilizing expertise with MediTECH, irradiation process performed by outside vendor(s) GMP - Validated Processes

[Orthopedics Spinal Implant] [Application: discs in spinal implants] Material [CHIRULEN 1020] Processes Properties and benefits: [Compression Molding, Stabilization under N 2 ] High dimensional stability Very high toughness and wear resistance Full traceability for 30 years GMP - Validated Processes Biocompatible per USP Class VI requirements

[Medical Devices] [Application: cutting block for medical device] Material [CHIRULEN 1020] Processes Properties and benefits: [Compression Molding, Stabilization under N 2 ] High dimensional stability Very high toughness and wear resistance Full traceability for 30 years GMP - Validated Processes Biocompatible per USP Class VI requirements

MediTECH Product Line: Locations within Quadrant MediTECH U.S. MediTECH U.K. MediTECH France MediTECH Italy MediTECH Hungary MediTECH Germany MediTECH China MediTECH Japan MediTECH India Primary Conversion Heat Treating & Finishing Cross-linking Custom Processing Sales & Distribution R&D / Testing Laboratory Primary Conversion Heat Treating & Finishing Cross-linking Custom Processing Sales & Distribution R&D / Testing Laboratory

MediTECH - Quality Management Quality Guidelines: ASTM F 648 and ISO 5834, customer s specification Resin lot qualification process Cross-check for physical/mechanical properties with Ticona (raw material supplier) and MediTECH U.S. Monthly resin lot verification and cross-check Dedicated MediTECH press operation since 1994 100 % press cycle verification Validated compression molding process Validated annealing cycles (nitrogen atmosphere) AQL10 - visual inspection ISO 9001 certified ISO 14001 certified ISO 13485 certified

MediTECH - Quality Management Lot Qualification Process TICONA 1250 kg per lot for testing and qualification purposes Converting of sheets (pressing) Certificate acc. to EN 10204-3.1. Scrap Annealing Planing N o Y e s Pressing? Sawing Visual check MediTECH USA Check of physical properties Investigation : PHS USA OFG Ticona Reason? No o.k.? YES Release Documentation in Database

Process parameters are visualized and filed during the entire process Quality Manuals available in the Intranet for medical personnel Traceability System based on Electronic Database

MediTECH - Technology Annealing Technology using Nitrogen Atmosphere - Tight implant tolerances - preventing material oxidation - Quenching free radicals after cross linking

MediTECH - Quality Management How does MediTECH Division ensure the extremely high quality standard necessary for CHIRULEN and EXTRULEN? CHIRULEN and EXTRULEN products undergo intensive visual inspection to make sure requirements of ISO 5834 and ASTM F 648 are by far exceeded.

Test per ISO 5834-1 and ASTM F-648 at Ticona 1,60 1,40 1,20 1,00 0,80 0,60 0,40 0,20 0,00 Resin Cleanliness Ticona average impurity level - Historical development Okt 95 Mrz 97 Jul 98 Dez 99 Apr 01 Sep 02 Jan 04 Mai 05 Okt 06 Feb 08 Jul 09 Nov 10

Shape Cleanliness Test per ISO 5834-2 and ASTM F-648 at QEPP MediTECH

MediTECH - Technology State of the art machining operations CNC lathe without cooling agent (for preforms only no final implant component!) Optical and mechanical measurement device AQL10 optical inspection

MediTECH - Technology Quality standards achieved by: -> continuous process improvements and well trained people resin pressing annealing Machining (preforms) Resin lot qualification and Cross-check process Reduced contamination by training the operators Validated resin conditioning Dedicated press Small scale press High pressure operations No release agents Validated in the manner of GMP Cycle for dimensional stability, low stress Unique inert process, prevent oxidation No cooling agents Special tooling and machining parameters Optical inspection of surface quality

MediTECH - Technology Process/Product Innovation Proven Research and Development capabilities MediTECH conversion evolution Next generation pressing technology for product and process improvement Improved homogeneity through optimized resin handling Radiation processing (Crosslinking) Developed jointly with our customers R&D / Technical Departments Leading supplier of Crosslinked UHMWPE in bulk form Radiation processing (Crosslinking) Stabilized PE-UHMW Blend PE-UHMW with additives, to improve oxidation behavior Developed jointly with our customers R&D / Technical Departments

Jointly developed Medical Polymers: UHMW-PE with Vitamin E Start Take off Feasibility, material and process development, investment, Supplier- Join-In, trials, validation DEVELOPPERS DESIGNERS ENABLERS Process feasibility & structure development Phase 1 Phase 3 Phase 3 Scale up & optimization, PFMEA Validation, Operation & Performance Qualification (IQ, OQ, PQ)

Cross-linking of medical grade PE-UHMW Highly cross-linked medical grade PE-UHMW Latest development in the orthopedic implant industry with regard to Polyethylene: - Highly cross-linked PE-UHMW with improved tribological properties. - Highly cross-linking achieved through either electron beam or gamma irradiation and subsequent, specially designed, annealing process to eliminate free radicals. - to markedly improve the wear resistance of UHMWPE - to significantly reduce the number of wear particles generated in vivo.

Cross-linking of medical grade PE-UHMW Radiation Chemistry Gamma Irradiation E-Beam Irradiation Conventional Chemistry Peroxide Chemistry Silane Chemistry Radiation Units: 10 kgy = 1 Mrad Typical sterilization dose levels: 25-40 kgy = 2.5-4 Mrad Highly cross-linking: above typical dose level of sterilization.

E-beam and gamma irradiation E-beam irradiation Gamma irradiation 1 - penetration depth of electrons 2 - primary electrons (source) 3 - secondary electrons 4 - irradiated material 5 - Co-60 irradiation source 6 - γ-quanta

Cross-linking of medical grade PE-UHMW What can MediTECH contribute to develop highly cross-linked PE- UHMW for orthopedic implants? MediTECH has several years experience developing highly cross-linked PE-UHMW for orthopedic implants in close cooperation with leading orthopedic implant manufacturers MediTECH currently provides significant commercial quantities of radiation cross-linked PE-UHMW to the orthopedic industry MediTECH understands the radiation process with respect to PE-UHMW closely cooperating with radiation vendors MediTECH knows how radiation and subsequent annealing affects PE- UHMW MediTECH has more than 20 years experience heat treating PE-UHMW for stabilization on large scale

Cross-linking of medical grade PE-UHMW Supply chain for highly cross-linked premium PE-UHMW 1. MediTECH produces semi-finished PE-UHMW products (CHIRULEN and EXTRULEN ) 2. Irradition of PE-UHMW semi-finished products at irradiation vendor at specified dose range (note: the dose range is to be specified by the OIM) 3. Specially designed annealing process at MediTECH to eliminate residual free radicals and to complete cross-linking process (note: annealing temperature and process is to be specified by the OIM) 4. Machine finish of highly cross-linked PE-UHMW products (planed sheets, rods, preforms etc.) at MediTECH 5. Delivery to customer, machine finish, packaging, sterilization

Options for highly cross-linked premium PE-UHMW Example for a process specification to be devised by the Impant Manufacturer Step 1 base material Chirulen 1020/1050 CHIRULEN 1020 2 shape initial size sheet 1000x500 [mm] x [mm] at irradiation rod 1000 [mm] x 70 [mm] 3 irrdiation gamma, dose rate 75 [kgy], Tolerance: +/- 10 % e-beam, dose rate [kgy] Temperature Atmosphere (Air/Inert) room temperature [ C] Air 4 quenching MediTECH cycle 150 [ C] 110 / 150 Atmosphere (Air/Inert) Inert (= Nitrogen) 5 remove surface final shape sheet 1000x500 [mm] x [mm] after irradiation and rod 1000 [mm] x 60 [mm] annealing/quenching 6 packaging standard/ black PE film black PE film