MCQ Data Aquisition Board. Preliminary Datasheet

Similar documents
NEW. EVEN MORE data acquisition and test stand automation

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

EVAL-UFDC-1/UFDC-1M-16

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DCP Fan Controller. Version 01/2009. The engineer s choice

User s Manual of Board Microcontroller ET-MEGA2560-ADK ET-MEGA2560-ADK

DC Electronic Loads 8500 series

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Optimize your simple machines... Modicon M218 Selection Guide

DCS Series 1 kw, 1.2 kw, & 3 kw

User Manual. AS-Interface Programmer

NC-12 Modbus Application

ECP & ECP240-32EX

SL Series AC and DC Electronic Loads

Wireless Temperature

AN2680 Application note

Programming Logic controllers

Vibration analysis and monitoring Compact. Powerful. Modern technology.

EDI Distributor Control Interface Wiring and Setup Instructions

DS1104 R&D Controller Board

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

The I2C Bus. NXP Semiconductors: UM10204 I2C-bus specification and user manual HAW - Arduino 1

PD 100A. Printing data system

1.44 kw Programmable DC Power Supplies XLN Series

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

If an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

International Journal of Electronics and Computer Science Engineering 1588

HDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Multi-Range Programmable DC Power Supplies 9115 Series

Designing VM2 Application Boards

Arduino ADK Back. For information on using the board with the Android OS, see Google's ADK documentation.

EN54-16 Voice Alarm System PRODUCT DATASHEETS

PCAN-MicroMod Evaluation Test and Development Environment for the PCAN-MicroMod. User Manual. Document version ( )

Multi-Range Programmable DC Power Supplies 9115 Series

1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

NETWORK ENABLED EQUIPMENT MONITOR

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

PCS0100en Persy Control Services B.V. Netherlands

Bluetooth HC-06 with serial port module Easy guide

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

MILE Encoder for EC 90 flat

USB-500 Series Stand-Alone, Low-Cost Data Loggers

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

Controlers. Controler

Rackmount Intelligent Pressure Scanners

JTAG-HS2 Programming Cable for Xilinx FPGAs. Overview. Revised January 22, 2015 This manual applies to the HTAG-HS2 rev. A

Part Number Description Packages available

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

M2M/IoT Solutions.

ENCODER TEST MODULE APPLICATION GUIDE

DS1621 Digital Thermometer and Thermostat

KS732 Family. Rev KS732. 1/3 CCD Color USB Camera

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

AN4646 Application note

User manual Compact Web PLC WP240 series IEC-line

MFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information

MH - Gesellschaft für Hardware/Software mbh

DS1621 Digital Thermometer and Thermostat

PICNet 1. PICNet 1 PIC18 Network & SD/MMC Development Board. Features. Applications. Description

Current plugin version: V2.145

How To Use A Watt Saver On A Microcontroller (Watt Saver) On A Cell Phone Or Mp3 Player

DS1307ZN. 64 x 8 Serial Real-Time Clock

- 35mA Standby, mA Speaking pre-defined phrases with up to 1925 total characters.

6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE

Current Monitoring Kit QUICK START GUIDE

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15 TUTORIAL OUTCOME 2 Part 1

Electronic Control Devices The European Product Catalogue 2007

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

USB-AD14f Data Acquisition System (USB)

Simplify Data Acquisition with a Built-in LXI Web Server

BrightSign Expander Hardware Guide

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Tire pressure monitoring

K-Type Thermocouple Sensor User s Guide

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

Current Monitoring Kit

High Power Programmable DC Power Supplies PVS Series

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015

Dyeing Programmer DP - 01

Lab Experiment 1: The LPC 2148 Education Board

Transcription:

MCQ Data Aquisition Board Preliminary Datasheet

Technical Data Sheet Specifications: Resolution: Max 24-bit Number of Channels: 8 Max Max Sampling Rate: from 50 Hz to 2 KHz programmable for each channel. Data acquisition from your own sensor up to 8 sensors, with Sensor Board. Ideal for OEM applications. User interface with 3 push-buttons and 4 LED Low cost. Power Supply: 12-36 V AC/DC USB interface Modular Architecture I2C BUS with build-in drivers for: Sensirion SHTxx series (Temperature/Relative Humidity) Sensirion SDP600 series (Differential Pressure) 4 digital input (Normally Open) 2- channel PWM for valves and actuator control 2 programmable analog output channels (0-5V), Max 80 ma Firmware Update from USB. Easy integration and communication with all MCQ Instruments products to make Custom Solution for laboratory uses. 485 BUS with open propetary protocol. The MCQ Data Acquisition Board is designed to provide a complete data acquisition solution for test and measurement applications and control several kinds of actuators. The MCQ Data Acquisition Board can collect data from 8 different sensors with an optional signal conditioning daughter card called Sensor Board. The Sensor Board is easily adapted to different sensors granting the maximum sensor performances and allowing test automation and control, calibration processes and the possibility to store all results. All this features make this Board ideal for OEM applications 2/10

TECHNICAL SPECIFICATIONS Input Range - +625 mv, +1.25 V, +2.5 V, ±625 mv, ±1.25 V, ±2.5 V Resolution Max 24 Bit Number of Channels 8 Sampling Rate Power Supply User Interfaces from 50 Hz to 2 KHz programmable for each channel 12-36 V AC/DC 3 push-function button and 4 LEDs Connectors Interfaces Slot for custom daughter board Sensor board 4 digital input (Normally Open) I2C BUS with build-in drivers for: Sensirion SHTxx series (Temperature/Relative Humidity) Sensirion SDP 600 series (Pressure) Other I2C Devices on request USB PC Interface 485 BUS with open propetary protocol 2 PWM channel for valves and actuator control 2 programmable output analog channels Analog Output (0-5V), Max 80 ma Output Signal Digital: 485 BUS with open propetary protocol 3/10

Connections: The image below illustrates you the interfaces and connections of the Board. 12 Power 13 Actuators 14 Flow 15 USB 16 Connectors Control Connector 485 Connector 17 Firmware Update Connector 1 2 3 4 USB Led Programmable Led Power Led System Programming Led 5 Reset 6 Programmable Switch 7 Programmable Switch 8 I 2 C Connector 11 Sensor board connectors 10 Microcontroller 9 Digital Input 4/10

Digital Input: 4 digital inputs for external communication with external devices or external switches or remotes. The digital input channels of DATA Acquisition Board are TTL and CMOS compatible. DIGITAL INPUT 4 - DIGITAL INPUT 3 - DIGITAL INPUT 2 - DIGITAL INPUT 1 + Digital Input Circuit: The digital input circuits have a 10 KOhm pull up resistor to 3.3 Volt, as illustrated in the figure below. This forces the digital inputs to be normally high, and allows contact closures to be connected directly between the digital input channels and which will pull the channel low when contacts are closed. Digital Inputs are reverse voltage protected, and protected against over voltage with internal CLAMP DIODES DVDD_3.3V D4 Connection: 4.7K R1 Diode TVS DIN1 + DIN2 + DIN3 + DIN X C1 D1 D2 D3 R3 R2 4.7K 47K C2 TO MICROPROCESSOR DIN4 + 100pF 100pF 5/10

Actuator Input: ANALOG OUTPUT 2 (PUMP) + ANALOG OUTPUT 2 (PUMP) - - ANALOG OUTPUT 1 (PUMP) + ANALOG OUTPUT 1 (PUMP) - PROPORTIONAL VALVE 2 (PWM) + PROPORTIONAL VALVE 2 (PWM) - PROPORTIONAL VALVE 1 (PWM) + PROPORTIONAL VALVE 1 (PWM) - Proportional Valve 1 & 2 PWM Output 0-10 V, with PWM frequency selectable from 1 KHz to 20 KHz Proportional Valve 1-2 can be used with any actuator requiring PWM input. Proportional Valve 1-2 can be also used to control solenoid valves (ON-OFF) with LOW STATE = 0V and HIGH STATE = 10V Max current for each channel: 150 ma Analog Output 1 & 2 0 5V Analog Ouput for analog actuators and analog controlled devices (diaphragm pumps and other analog devices) Analog Outputs can be also used to control low voltage solenoid valves (ON-OFF) with LOW STATE = 0V and HIGH STATE selectable by user in the range 0-5V Different upper range is possible upon customer request ( max 10V) Max current for each channel: 150 ma 6/10

Power Supply: DC IN 2 (12-24V) DC IN 1 (12-24V) The Data Acquisition Board requires a DC supply in the range 12-24 V. Min current supply: 600 ma. DC Input is not polarized. Internal Diode Rectifier provides the right polarization. Power Supply + and - could be connected indifferently to each position of the connector. Fast DAC Output: DC IN 2 (12-24V) DC IN 1 (12-24V) Output non-implemented in the current firmware release. For future use (e.g. sound alarms or piezo actuators). 7/10

BUS RS 485: DC OUT - (10V) DC OUT + (10V) RS 485 - B RS 485 - A Flow Board can assume both MASTER or SLAVE rule in a MASTER/SLAVE environment. Proprietary BUS protocol provides fast and secure communication between each MCQ Instruments device. Flow Boards, Acquisition Boards and Gas Blenders can be connected togheter with a maximum number on each bus of 64 devices. One MASTER is required on each BUS. MASTER device provides with BUS setup function a scan of the BUS network searching for connected SLAVE devices (each SLAVE device must have a unique address in the range 11-74, Address 10 is reserved to MASTER device). Once scan is complete, MASTER device stores in non-volatile memory the bus configuration with addressed and rules. On restart MASTER will provide BUS monitoring and it will be able to detect a failure of each of the SLAVE device, reporting it as an alarm. In this case MASTER will continue to communicate with all other remaining devices. For more information contact support@mcqinst.com For details of 485 BUS protocol functions, download document Communication Protocol from our website. 8/10

I2C BUS: I2C SCL VDD 3.3 V I2C SCK User can connect via I2C various sensors using this protocol. The flow board can supply 3.3V DC with a maximum current of 100 ma MCQ Instruments periodically develops drivers for various third-part sensors like Pressure sensors, Relative Humidity and Temperature sensors, etc. Flow Board actually includes drivers for the following sensors: 1) Sensirion SHTXX series Relative Humidity and Temperature 2) Sensirion SDP600 series Differential Pressure Other drivers can be developed on request. For more information contact support@mcqinst.com 9/10

Contact MCQ Instruments MCQ s.r.l. Via delle Quattro Fontane, 33 00184 - Rome - Italy Phone: +39 06.48.47.90 Fax: +39 06.99.33.15.98 info@mcqinst.com support@mcqinst.com 10/10