Structural Analysis of a Multi-Storeyed Building using ETABS for different Plan Configurations

Similar documents
SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

The International Journal Of Science & Technoledge (ISSN X)

SEISMIC RETROFITTING OF STRUCTURES

Optimum proportions for the design of suspension bridge

Structural Design of Multi-story Residential Building for in Salem, India

ANALYSIS AND DESIGN OF RC TALL BUILDING SUBJECTED TO WIND AND EARTHQUAKE LOADS

Seismic performance evaluation of an existing school building in Turkey

Seismic Risk Evaluation of a Building Stock and Retrofit Prioritization

Structural Design Criteria & Design Loads on Delhi Metro Rail and Checking of Safety of Radial Joints in Tunnel Lining Segments

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Seismic Risk Prioritization of RC Public Buildings

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

SEISMIC APPROACH DESIGN COMPARISON BETWEEN

CH. 2 LOADS ON BUILDINGS

INTRODUCTION TO LIMIT STATES

A project report on, Prepared in partial fulfillment of. Study oriented project, Course code: CE G611 Computer Aided Analysis and Design

Aluminium systems profile selection

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

The University of Birmingham (Live System)

Effect of Container Height on Base Shear of Elevated Water Tank

Specification for Structures to be Built in Disaster Areas

9.3 Two-way Slabs (Part I)

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

Chapter. Earthquake Damage: Types, Process, Categories

A Case Study Comparing Two Approaches for Applying Area Loads: Tributary Area Loads vs Shell Pressure Loads

Concrete Frame Design Manual

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

Seismic Isolated Hospital Design Practice in Turkey: Erzurum Medical Campus

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Advanced Retrofitting Methods and Techniques for RC Building: State of an Art

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

Retrofitting of Existing RCC Buildings by Method of Jacketing

DISASTER RESISTANCE EARTHQUAKES AND STRUCTURES

ARCHITECTURE. Asst. Prof. Meltem VATAN KAPTAN

Technical Notes 3B - Brick Masonry Section Properties May 1993

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Performance-based Evaluation of the Seismic Response of Bridges with Foundations Designed to Uplift

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

In this study analytical investigation of effect of retrofit application using carbon fiber (CFRP) on seismic behavior of a monumental building at

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

Seismic Analysis and Design of Steel Liquid Storage Tanks

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT

Comparison of Seismic Performance of D-region of Existing RC Structures Designed with Different Recommendations

Analysis of a Tower Crane Accident

SEISMIC CAPACITY OF EXISTING RC SCHOOL BUILDINGS IN OTA CITY, TOKYO, JAPAN

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

Methods for Seismic Retrofitting of Structures

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

Seismic Evaluation and Retrofitting of RC Building by Using Energy Dissipating Devices

New approaches in Eurocode 3 efficient global structural design

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY

Design Example of a Six Storey Building

A NEW DESIGN METHOD FOR INDUSTRIAL PORTAL FRAMES IN FIRE

Simulation for the Collapse of WTC after Aeroplane Impact

Structural fire design Eurocode Timber structures

Design and Construction of Cantilevered Reinforced Concrete Structures

HOUSE BUILDING DIGEST

SEISMIC DESIGN OF TWO STOREY REINFORCED CONCRETE BUILDING IN MALAYSIA WITH LOW CLASS DUCTILITY

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

Structural Audit of Buildings

MECHANICS OF SOLIDS - BEAMS TUTORIAL 2 SHEAR FORCE AND BENDING MOMENTS IN BEAMS

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

Design Of Reinforced Concrete Structures ii Two-Way Slabs

Design Manual to BS8110

NPTEL STRUCTURAL RELIABILITY

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

Elevating Your House. Introduction CHAPTER 5

Structural Analysis. EUROCODE 2 Background and Applications

bi directional loading). Prototype ten story

PARAMETRIC STUDY OF THE STRUCTURES (INFLUENCE OF THE SHELLS)

Structural Design Calculation For Pergola

BLIND TEST ON DAMAGE DETECTION OF A STEEL FRAME STRUCTURE

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

Predicting Seismic Vulnerable Zones using GIS. Outline of the presentation. Objectives. Risk Mapping Overview Factor Maps. Three levels of Zonation

Expected Performance Rating System

Five reasons buildings fail in an earthquake and how to avoid them

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

ENGINEERING SCIENCE H1 OUTCOME 1 - TUTORIAL 3 BENDING MOMENTS EDEXCEL HNC/D ENGINEERING SCIENCE LEVEL 4 H1 FORMERLY UNIT 21718P

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

EARTHQUAKE DESIGN OF BUILDINGS

Transcription:

Structural Analysis of a Multi-Storeyed Building using ETABS for different Plan Configurations Abhay Guleria Undergraduate, Deptt. of Civil Engineering, J.N.G.E.C. Sundernagar, Sundernagar, India Abstract ETABS stands for Extended Three dimensional Analysis of Building Systems. ETABS is commonly used to analyze: Skyscrapers, parking garages, steel & concrete structures, low and high rise buildings, and portal frame structures. The case study in this paper mainly emphasizes on structural behavior of multi-storey building for different plan configurations like rectangular, C, L and I-shape. Modelling of 15- storeys R.C.C. framed building is done on the ETABS software for analysis. Post analysis of the structure, maximum shear forces, bending moments, and maximum storey displacement are computed and then compared for all the analyzed cases. Keywords- Structure Design, ETABS, High Rise Buildings, Plan Irregularity I. INTRODUCTION Structural analysis means determination of the general shape and all the specific dimensions of a particular structure so that it will perform the function for which it is created and will safely withstand the influences which will act on it throughout its useful life. ETABS was used to create the mathematical model of the Burj Khalifa, designed by Skidmore, Owings and Merrill LLP (SOM). The input, output and numerical solution techniques of ETABS are specifically designed to take advantage of the unique physical and numerical characteristics associated with building type structures. ETABS provides both static and dynamic analysis for wide range of gravity, thermal and lateral loads. Dynamic analysis may include seismic response spectrum or accelerogram time history. This analysis mainly deals with the study of a rectangular, L, C and I shaped plan using ETABS. A 32m x 24m 15- storeys structure having 4m x 4m bays is modelled using ETABS. The height of each storey is taken as 3m, making total height of the structure 45m. Loads considered are taken in accordance with the IS-875(Part1, Part2), IS-1893(2002) code and combinations are acc. to IS-875(Part5). Post analysis of the structure, maximum shear forces, bending moments, and maximum storey displacement are computed and then compared for all the analysed cases. II. MODELLING OF RCC FRAMES An RCC framed structure is basically an assembly of slabs, beams, columns and foundation inter-connected to each other as a unit. The load transfer mechanism in these structures is from slabs to beams, from beams to columns, and then ultimately from columns to the foundation, which in turn passes the load to the soil. In this structural analysis study, we have adopted four cases by assuming different shapes for the same structure, as explained below. 1. Rectangular Plan 2. L-shape Plan 3. I-shape Plan 4. C-shape Plan The building is 32m x 24m in plan with columns spaced at 4m from center to center. A floor to floor height of 3m is assumed. Plan of the building for all the cases is shown in the following figure. Units Fig 1: Plan (a) Rectangular (b) L shape (c) I shape (d) C shape of the Building 1481

TABLE 1 Building Description Length x Width 32m x 24m No. of storeys 15 Storey height 3m Beam dimensions 450x450mm = 2.07 kn/m (acting on the beam) 3. Live load: Floor load: 4kN/m 2 and Roof load: 2 kn/m 2 (IS 875 (Part 2) acting on beams 4. Seismic Load: Seismic zone: V (Z=0.36), Soil type: I, Importance factor: 1, Response reduction factor: 5, Damping: 5%. IS 1893(Part-1):2002. Column 1-5 storeys dimensions Column 6-12 storeys dimensions 600x600mm 500x500mm Here Seismic load is considered along two directions EQlength and EQwidth Slab thickness 125mm Thickness of main wall 230mm Height of parapet wall 0.90m Thickness of parapet wall 115mm Support conditions Fixed V. LOADING COMIBINATION The structure has been analyzed for load combinations considering all the previous loads in proper ratio. Combination of self-weight, dead load, live load and seismic load was taken into consideration according to IS-code 875(Part 5). TABLE 3 III. MATERIAL SPECIFICATIONS TABLE 2 Material Specifications Grade of Concrete,M30 f ck= 30N/mm 2 Grade of Steel f y= 415N/mm 2 Density of Concrete ϒ c= 25kN/m 3 Density of Brick walls considered ϒ brick= 20kN/m 3 IV. LOADING Loads acting on the structure are dead load (DL), Live load and Earthquake load (EL). 1. Self weight comprises of the weight of beams, columns and slab of the building. 2. Dead load: Wall load, Parapet load and floor load (IS 875(Part1)) a) Wall load= (unit weight of brick masonry X wall thickness X wall height) = 20 kn/m 3 X 0.230m X 3m = 13.8 kn/m (acting on the beam) b) Wall load (due to Parapet wall at top floor) = (unit weight of brick masonry X parapet wall thickness X wall height) = 20 kn/m 3 X 0.115m X 0.90m 1482

VI. MODELLING IN ETABS Fig 2: 3-D View of the 15-storeys Rectangular-shape building VII. RESULTS AND DISCUSSIONS TABLE 4 Max B.M. and Force of Beam Forces Rectangular L-shape I-shape C-shape B.M. M y 92.99 97.38 101.54 99.74 B.M. M z 0.11 1.56 0.64 1.12 Force F y 161.09 159.18 158.18 159.27 Units kn-m TABLE 5 Max B.M. and Force of Column Forces Rectangular L-shape I-shape C-shape Axial Force F x 399.265 453.41 400.40 435.03 Force F y 88.16 87.68 91.96 90.59 Force F z 90.11 86.15 95.23 87.59 B.M. M y 181.93 172.35 174.40 173.63 B.M. M z 182.11 172.24 173.64 172.39 Storey Overturning Moments for different Plan Configurations Fig 3: 3-D View of the 15-storeys L-shape building VII. USING THE TEMPLATE Fig 4: 3-D View of the 15-storeys I-shape building Fig 6: Storey Height Vs Overturning Moments The figure shows that the overturning moment varies inversely with storey height. In case of rectangular plan, a moment produced is higher than other shapes. Storey overturning moment decreases with increase in storey height for all cases. Comparison of Storey for 1 st, 5 th, 10 th, 15 th storey for different configurations Fig 5: 3-D View of the 15-storeys C-shape building Fig 7: Graph of Storey for different Plan configurations 1483

As per above fig. it has been concluded that the storey shear decreases with the increase in storey height. Storey shear is less in L-shape building among all the cases. C paper and are not topically subordinate to each other. Fig 8:Graph of Storey for 5 th Storey Roof Displacement Vs Height of the Building Fig 9: Graph of Storey Drift Vs Storey height STOREY TABLE 6 LATERAL DISPLACEMENT (mm) Rectangular L-shape I-shape C-shape 0 0 0 0 0 1 1.37 1.30 1.27 1.37 2 3.41 3.58 3.51 3.41 3 5.95 6.29 5.85 6.05 4 8.49 9.11 8.29 8.59 5 11.12 12.03 10.93 11.32 6 13.76 15.07 13.76 14.24 7 16.78 18.32 16.49 17.37 8 19.51 21.57 19.41 20.39 9 22.24 24.72 22.15 23.22 10 24.59 27.64 24.49 25.85 11 26.83 30.46 26.93 28.49 12 28.88 32.95 28.88 30.63 13 30.15 34.91 30.34 32.49 14 31.61 36.86 31.71 34.15 15 32.39 38.16 32.78 35.02 Above table shows that the storey displacement increases with the increase in storey height. Displacement in rectangular shape building is less than other cases. Max Lateral Drift for various storey heights TABLE 7 STOREY LATERAL DRIFT (mm) Rectangular L-shape I-shape C-shape 0 0 0 0 0 1 3.9 3.8 3.8 3.8 2 7.3 7.3 7.2 7.4 3 8.1 8.4 8.1 8.4 4 8.2 8.7 8.4 8.8 5 8.2 8.9 8.5 9 6 9.5 10.04 9.7 10.03 7 9.4 10.01 9.6 10.01 8 9.0 9.8 9.3 9.9 9 8.5 9.4 8.9 9.5 10 7.9 8.8 8.3 9.0 11 7.1 8.0 7.6 8.3 12 6.2 7.2 6.7 7.4 13 5.1 6.1 5.6 6.3 14 3.7 4.8 4.3 5.0 15 2.3 3.7 3.1 3.9 Fig 9: Mode Shape for 12 th mode for (a) Rectangular (b) L-shape (c) I- shape (d) C-shape of the building VIII. CONCLUSIONS The analysis of the multi-storeyed building reflected that the storey overturning moment varies inversely with storey height. Moreover, L-shape, I-shape type buildings give almost similar response against the overturning moment. Storey drift displacement increased with storey height up to 6 th storey reaching to maximum value and then started decreasing. From dynamic analysis, mode shapes are generated and it can be concluded that asymmetrical plans undergo more deformation than symmetrical plans. Asymmetrical plans should be 1484

adopted considering into gaps. The Fig. 9 shows that asymmetrical plans undergo more deformation and hence symmetrical plans must be adhered to. ACKNWOLEDGMENT This case study would not have been possible without the able guidance of Prof.RL Sharma, Director JNGEC, S.P.Guleria (H.O.D.), Madhu Sharma, Assistant Professor, and Tarun Goel, Assistant Professor, Civil Engineering. I extend my heartfelt thanks to our worthy faculty. REFERENCES [1] Poonam, Anil Kumar and A. K. Gupta, Study of Response of Structural Irregular Building Frames to Seismic Excitations, International Journal of Civil, Structural, Environmental and Infrastructure Engineering Research and Development, Vol.2, Issue 2 (2012) 25-31 [2] B. K. Sanghani and P. G. Patel, Behaviour of Building Component in Various Zones, International Journal of Advances in Engineering Sciences, Vol. 1, Issue 1(Jan. 2011) [3] P. Prashanth, S. Anshuman, R.K. Pandey, Herbert Arpan, Comparison of design results of a Structure designed using STAAD and ETABS Software, INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING, Volume 2, No 3, 2012 [4] Salahuddin Hammad, Habib Saqib, Rehman Talha, Comparison of design of a building using ETABS V 9.5 & STAAD PRO, 2005 [5] Bureau of Indian Standards: IS-875, part 1 (1987), Dead Loads on Buildings and Structures, New Delhi, India. [6] Bureau of Indian Standards: IS-1893, part 1 (2002), Criteria for Earthquake Resistant Design of Structures: Part 1 General provisions and Buildings, New Delhi, India. 1485