Title Release Notes PC SDK 5.14.03. Date 2012-03-30. Dealt with by, telephone. Table of Content GENERAL... 3. Corrected Issues 5.14.03 PDD...



Similar documents
Title Release Notes PC SDK Date Dealt with by, telephone. Table of Content GENERAL... 2

Release Notes RAB Date Table of Content GENERAL Release Information...2. Introduction...2. Installation...

Release Notes FlexPendant SDK Date Table of Content GENERAL Release Information...2. Introduction...2. Installation...

Release Notes FlexPendant SDK

Release Notes FlexPendant SDK

Release Notes FlexPendant SDK

Release Notes FlexPendant SDK

Application manual Robot Application Builder

ABB Robotics. Application manual PC SDK

Out n About! for Outlook Electronic In/Out Status Board. Administrators Guide. Version 3.x

Wise Package Studio 8.0 MR1 Release Notes

Appendix F: Instructions for Downloading Microsoft Access Runtime

UNICORN 7.0. Administration and Technical Manual

Measurement Studio. Contents RELEASE NOTES

UNICORN 6.4. Administration and Technical Manual

Pcounter Web Report 3.x Installation Guide - v Pcounter Web Report Installation Guide Version 3.4

Guide to Installing BBL Crystal MIND on Windows 7

Click Studios. Passwordstate. Upgrade Instructions to V7 from V5.xx

What s New RobotStudio

2014 Electrical Server Installation Guide

Getting Started with the Ed-Fi ODS and Ed-Fi ODS API

TECHNICAL DOCUMENTATION SPECOPS DEPLOY / APP 4.7 DOCUMENTATION

CAPIX Job Scheduler User Guide

Installation Guide: Delta Module Manager Launcher

Archive Attender Version 3.5

Installation Guide. Release Management for Visual Studio 2013

Perceptive Intelligent Capture. Product Migration Guide. with Supervised Learning. Version 5.5 SP3

RobotWare 6 External Presentation

Zanibal Plug-in For Microsoft Outlook Installation & User Guide Version 1.1

Table of Content RELEASE INFORMATION... 2 ORDERING AND INSTALLATION... 3 CHANGES IN CUTTING POWERPAC

To install Multifront you need to have familiarity with Internet Information Services (IIS), Microsoft.NET Framework and SQL Server 2008.

BUILDER 3.0 Installation Guide with Microsoft SQL Server 2005 Express Edition January 2008

Administration guide. Host software WinCCU Installation. Complete gas volume and energy data management

Getting Started with the LabVIEW Mobile Module Version 2009

Integrating an ASP.NET MVC Web Application in Sitecore CMS

Symantec Backup Exec 12.5 for Windows Servers. Quick Installation Guide

Iron Speed Designer Installation Guide

FAQ CE 5.0 and WM 5.0 Application Development

for Networks Installation Guide for the application on a server September 2015 (GUIDE 2) Memory Booster version 1.3-N and later

System Requirements for Microsoft Dynamics NAV 2013 R2

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version

Graphic Generation Tool Installation Instructions Code No. LIT Software Release 1.3 Issued December 5, 2014

multiple placeholders bound to one definition, 158 page approval not match author/editor rights, 157 problems with, 156 troubleshooting,

Filestream Ltd. File Stream Document Management Integration Overview

Application Note CTAN #374

Citrix Worx App SDK Overview

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

How To Install Database Oasis On A Computer Or Computer (For Free)

Introduction and Overview

for Networks Installation Guide for the application on the server August 2014 (GUIDE 2) Lucid Exact Version 1.7-N and later

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

DOCSVAULT Document Management System for everyone

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

System Requirements for Microsoft Dynamics NAV 2016

for Networks Installation Guide for the application on the server July 2014 (GUIDE 2) Lucid Rapid Version 6.05-N and later

NSi Mobile Installation Guide. Version 6.2

Release Notes, QuickBooks SDK 11.0 (09/14/2011) Welcome to the QuickBooks Software Development Kit (SDK) Version 11.0.

InstallAware for Windows Installer, Native Code, and DRM

Software Installation Arc Welding System M2004 IRC5

Ipswitch Client Installation Guide

Citrix EdgeSight for Load Testing Installation Guide. Citrix EdgeSight for Load Testing 3.8

Installation Notes for Outpost Network Security (ONS) version 3.2

VEEAM ONE 8 RELEASE NOTES

Upgrading Client Security and Policy Manager in 4 easy steps

NetIQ Advanced Authentication Framework - Administrative Tools. Installation Guide. Version 5.1.0

VERITAS Backup Exec TM 10.0 for Windows Servers

SOLIDWORKS Education Edition Installation Instructions Preparation

System Administration Training Guide. S100 Installation and Site Management

System Requirements for Microsoft Dynamics NAV 2016

Welch Allyn Connectivity SDK Development

WhatsUp Gold v16.3 Installation and Configuration Guide

PATROL Console Server and RTserver Getting Started

Pearl Echo Installation Checklist

Omgeo OASYS Workstation Installation Guide. Version 6.4 December 13, 2011

Copyrights, Legal Notices, Trademarks and Servicemarks

e-business Suite Server Install Guide

Witango Application Server 6. Installation Guide for Windows

How To Deploy Lync 2010 Client Using SCCM 2012 R2

How To Install An Aneka Cloud On A Windows 7 Computer (For Free)

Symantec Backup Exec 2010 R2. Quick Installation Guide

Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1

This document is provided to you by ABC E BUSINESS, Microsoft Dynamics Preferred partner. System Requirements NAV 2016

safend a w a v e s y s t e m s c o m p a n y

Kentico CMS 7.0 Installer documentation

DameWare Server. Administrator Guide

VirtualXP Users Guide

Installation Guide. Sitecore CMS 6.5. Installation guide for administrators and developers. Installation Guide Rev:

Sentinel Cloud V.3.5 Installation Guide

1 (11) Paperiton DMS Document Management System System Requirements Release: 2012/

LAE 5.1. Windows Server Installation Guide. Version 1.0

Getting Started with IVI-COM and Python for the Lambda Genesys Power Supply

Installation Manual v2.0.0

Network Licensing. White Paper 0-15Apr014ks(WP02_Network) Network Licensing with the CRYPTO-BOX. White Paper

Installation Guide for RTX 2011 with Service Pack 1

User Manual. 3-Heights PDF Producer API. Version 4.6

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015

Internet Information Services Integration Kit. Version 2.4. User Guide

Installing GFI Network Server Monitor

Sage ERP MAS 90 Sage ERP MAS 200 Sage ERP MAS 200 SQL. Installation and System Administrator's Guide 4MASIN450-08

Backup Exec 15. Quick Installation Guide

Transcription:

1/15 Table of Content GENERAL... 3 Release Information... 3 Introduction... 3 Installation... 4 Hardware and Software requirements... 5 Deployment... 6 Compatibility... 7 Updates in PC SDK 5.14.03 vs. 5.14.02... 8 Updates in PC SDK 5.14.02 vs. 5.14.01... 8 Updates in PC SDK 5.14.01 vs. 5.14... 8 Updates in PC SDK 5.14 vs. 5.13... 8 Information 5.14.03... 8 Information 5.14.02... 9 Information 5.14.01... 11 Information 5.14... 12 Information 5.13.02... 12 Information 5.13.01... 13 Information 5.13... 13 Corrected Issues 5.14.03 PDD... 14 Corrected Issues 5.14.02 PDD... 14 Corrected Issues 5.14.01 PDD... 14 Corrected Issues 5.14 PDD... 14 Corrected Issues 5.13.02 PDD... 14 Corrected Issues 5.13.01 PDD... 14 Corrected Issues 5.13 PDD... 14 Known Limitations... 15

2/15 Product Support... 15

3/15 General Release Information The information should be considered as last minutes information and most up-to-date. Introduction This file contains the release notes for PC SDK 5.14.03. PC SDK 5.14.03 is included in the RobotStudio installer, which is distributed on the RobotWare 5.14.03 DVD. It can be used for anyone who wants to develop a customized PC operator interface, for the IRC 5 controller. It can also be used to develop RobotStudio add-ins that interacts with the controller. With PC SDK it is possible to create an application that connects to one or several IRC5 controllers, real as well as virtual. No license is required to develop applications using PC SDK. The end user of a PC SDK application, needs to have the option PC Interface on the IRC5 controller. For download, updates and information, visit the RobotStudio Community: http://www.robotstudio.com/community. To get started, or to learn more, visit our Developer Center: developercenter.robotstudio.com. Here you will also find the User Forum, where developers discuss software problems and solutions online: http://www.robotstudio.com/forum. The installation includes software, documentation and tools as specified below: Software PC SDK (5.14.03) Documentation Application manual PC SDK (5.14.03), Html Help and Pdf). PC SDK erence Documentation (5.14.03), documentation of class libraries with method signatures in C# and Visual Basic (Html Help). Tools

4/15 ABBControllerAPI.msm - merge module including the PS SDK dlls to be used when a PC SDK application is deployed to a customer s PC ABB Industrial Robot Communication Runtime.msi - to be used when a PC SDK application is deployed to a PC without RobotStudio After installation the documentation can be launched from Windows Start Menu\Programs\ABB Industrial IT\Robotics IT\Robot Studio 5.14. In no event shall ABB be liable for incidental or consequential damages arising from use of this product, of the software and hardware described in relating product documentation. Installation To install PC SDK click RobotStudio on the RobotWare & RobotStudio DVD. If you select the default installation option Full, PC SDK will be installed. If you want to install only PC SDK and not RobotStudio select the installation option Custom. PC SDK 5.xx will be installed side by side with any previous major version of PC SDK 5.xx, while minor versions within a release will update to the latest one. Before you start the installation you are recommended to read chapter 2, Installation and development environment, in the PC SDK Application Manual which is available on the Documentation DVD in PDF format. Microsoft Visual Studio development environment is used to develop PC SDK applications. Visual Studio 2008 Express or better, or Visual Studio 2010 Express or better is required. The default installation path is C:\Program Files\ABB Industrial IT\Robotics IT\SDK\PC SDK 5.14.

5/15 Hardware and Software requirements Software requirements Microsoft Windows XP SP3 32bit edition Microsoft Windows 7 32bit edition Microsoft Windows 7 64bit edition Note! PC SDK application that shall be executed on Windows 7 64 bit edition, must be built with target platform set to x86. The default setting in VisualStudio 2008 is AnyCPU Microsoft Visual Studio 2008 PC SDK requires Express edition or better. Microsoft Visual Studio 2010 PC SDK requires Express edition or better. Note! PC SDK applications requires Robot Communications Runtime to be installed on your PC. It comes with the RobotStudio installation, but can also be installed separately from C:\Program Files\ABB Industrial IT\Robotics IT\SDK\PC SDK 5.14.\redistributable\RobotCommunicationRuntime after you have installed PC SDK. Recommended hardware 10 MB free disk-space on the installation hard disk IRC5 requirements - RobotStudio 5.14.xx for building a test system and for debugging and testing in the virtual environment - RobotWare option "PC Interface" for communication with IRC5 controller.

6/15 Deployment When you build a PC SDK stand alone executable (not a RobotStudio Add-In), and want to deploy it to the end users computer, you must ensure that all necessary dependencies are also deployed. Your application will not function without those dependencies. If RobotStudio and the PC SDK are already installed on the end users computer, the required assemblies may already be in place, but your application installer should not rely on that. To make sure that the PC SDK assemblies are deployed, include the merge module ABBControllerAPI.msm in your setup project. The merge module can be found in the folder ABB Industrial IT\Robotics IT\SDK\PC SDK 5.14\Redistributable. As an alternative you can include the individual assembly files and deploy them in the same folder as your executable. To make sure that Robot Communication Runtime is deployed, inform the end user to install it. A complete installer which you can distribute together with your application can be found in the folder, ABB Industrial IT\Robotics IT\SDK\PC SDK 5.14\Redistributable. Note 1: Deploy the same versions as your application was built with Please note. It is a requirement of the.net Common Language Runtime that the exact same version of the referenced assemblies, as your application was built with, are available on the target computer. For example if your application was built with ABB.Robotics.Controller.dll version 5.14.1032, the exact same version of this assembly must be deployed to the end users computer. Note 2: Getting older versions of the PC SDK assemblies and ABBControllerAPI.msm Previous versions of the PC SDK assemblies, and ABBControllerAPI.msm can be downloaded from http://developercenter.robotstudio.com.

7/15 Compatibility PC SDK 5.14 and 5.13 are compatible, there are no breaking changes. PC SDK communicates with the robot controller using the Robot Communication Runtime, which is designed to be backwards compatible with earlier versions of RobotWare. Note! Functionality introduced in later versions of RobotWare will not be available for a PC SDK application that is connected to a controller with an older version of RobotWare. For example the Messaging functionality is only supported on RobotWare 5.10 and above. This means that a PC SDK application cannot use the Ipc class when communicating with a controller with RobotWare 5.09. The code will compile, but an exception will be thrown at runtime. Application developers are responsible for handling this scenario in their applications. Please refer to the PC SDK erence Documentation for details. Note! Compatibility between RobotWare minor revisions is guaranteed (PC SDK 5.14.01 will be compatible with PC SDK/RW 5.14.02 etc). EventHandlers and events For 5.09 the internal event architecture was completely redesigned. 1. All previous event handlers are [Obsolete] and existing events are changed to the EventHandler<TEventArgs> generic delegate. Ex: This example shows how to change from the old to the new event handler type. // This old line will fail myeventlog.messagewritten += new MessageWrittenEventHandler( OnMessage ); // and should be replaced like this myeventlog.messagewritten += new EventHandler<MessageWrittenEventArgs>( OnMessage ); //or preferably myeventlog.messagewritten += OnMessage; 2. Previous versions of PC SDK used the Windows Thread Pool internally to raise events. From 5.09 a single thread is used to dispatch all events. This reduces the risk of race conditions in client code. However, it makes it even more important to use the Control.BeginInvoke(... )/Control.EndInvoke(... ) pattern to avoid event starvation. Additionally, we now raise all events internally prior to any external subscribers, as this will reduce the risk of race conditions between inner and external subscribers. If your application is based on Control.Invoke(... ) and not on Control.BeginInvoke(... ) all events will be serialized, both internally and externally. However in previous PC SDK versions you may encounter "out-of-order" events and thread pool starvation through the use of Control.Invoke(... ). Some public events raise an initial event immediately when the subscription is activated; however this is not consistent or by design and should therefore be avoided. Later versions of PC SDK will remove all initial events.

8/15 3. Mastership.Request(... ) throws an InvalidOperationException if the user is not authenticated against the controller, previous versions raised an ArgumentException. Updates in PC SDK 5.14.03 vs. 5.14.02 No updates Updates in PC SDK 5.14.02 vs. 5.14.01 No updates Updates in PC SDK 5.14.01 vs. 5.14 No updates Updates in PC SDK 5.14 vs. 5.13 No updates Information 5.14.03 Memory leak Fixed memory leak issue. Legacy Controller API Merge Modules and Assemblies On the Developer Center we have published old versions of the merge module ABBControllerAPI.msm, which you can use if you need to create an installer project, for a PC SDK application targeting an old version of RobotWare. We have also published an installer that can be used to install previous versions of PC SDK Controller API assemblies into the GAC. This is only of interest for developers who have created PC SDK installer projects which does not include the above mentioned merge module, and thus not contain all required files. Such applications needs RobotStudio to be installed, in order to work. If your end user reports that your application stops working when RobotStudio is removed or upgraded, they can use this installer to install the required assemblies. Note: The preferred solution is to update your installer project to include the ABBControllerAPI.msm merge module.

9/15 Redistributable assemblies are now shared The PC SDK redistributable assemblies in the merge module ABBControllerAPI.msm are now installed as shared in the Global Assembly Cache. This means that several applications using PC SDK can be installed and uninstalled on the same machine without affecting each other, when using ABBControllerAPI.msm. Information 5.14.02 PC SDK 5.14.01 assemblies are removed from the GAC When PC SDK 5.14.02 is installed, the 5.14.02 version of the PC SDK assemblies are installed in the GAC. The 5.14.01 assemblies are removed from the GAC, if not in use by another installed application. Hint: To force a PC SDK application built with an earlier version of the SDK, for example 5.14.01, to use the 5.14.02 assemblies, without first rebuilding it, you can include an assembly binding element in your app.config file. This may be useful on your development machine. On the end users machine it is recommended to deploy the correct assemblies. See section Deployment for more information. <runtime> <assemblybinding xmlns="urn:schemas-microsoft-com:asm.v1"> <dependentassembly> <assemblyidentity name="abb.robotics" publickeytoken="1da709b7d1f14b7b" culture="neutral" /> <bindingredirect oldversion="5.0.0.0-5.65535.65535.65535" newversion="5.14.2027.0"/> </dependentassembly> <dependentassembly> <assemblyidentity name="abb.robotics.controllers" publickeytoken="1da709b7d1f14b7b" culture="neutral" /> <bindingredirect oldversion="5.0.0.0-5.65535.65535.65535" newversion="5.14.2027.0"/> </dependentassembly> </assemblybinding> </runtime> Manage mastership for all controller resources It is now possible to request and release mastership over all resources of the controller at the same time. Example: Controller controller; using(mastership.request(controller)) { } // add your code here

10/15 By calling controller.ismaster you can check if you have mastership over all the resources. Event when Task.Enabled is changed The new event Controller.EnabledChanged is fired when the task selection state is changed. Task.Enabled can be set under the following conditions When using PC SDK from a RobotStudio Add-In, connected to a Virtual Controller, that is in Manual Mode, it is possible to set the task enabled property. Under all other conditions, setting the property will throw an exception. Type.GetObject renamed to Type.GetInstance The methods Type.GetObjects() and Type.GetObject(string name) has been renamed Type.GetInstances() and Type.GetInstance(string name) for usability reasons. The old methods can still be used but are marked as obsolete.

11/15 Fill ArrayData from string It is now possible to fill arrays from strings. If the string is not of the correct format, an exception of type RapidDataFormatException is thrown. Example: ArrayData data =... data.fillfromstring2(... ); Note: The fill from string implementations of all RAPID data type classes like Bool, RobTarget, Num, etc, is documented to through a RapidDataFormatException if the string is not of the correct format. However the behaviour was different than the documentation and various.net exceptions like NullerenceException, as the general PC SDK GenericControllerException was thrown instead. When fill from string was implemented for array types, it was desired to have the same error handling as for the atomic types, mentioned above. Throwing RapidDataFormatException instead of GenericControllerException, would break compatibility. In order to provide a consistent set of fill from string implementations the current FillFromString method was made obsolete in favour for FillFromString2 which implements the correct functionality and error handling. Class UserDefined initialized to a valid default value When creating an instance of the UserDefined class, its Components property now returns an array of sub components, representing the default value for the record type represented by the instance. In previous versions null was returned for a newly created UserDefined instance. Instance.SetAttribute works for string data type attributes It is now possible to set the value of attributes with string data type. AuthorizationException thrown when not logged in When calling methods that requires a logged on user, without a previous logon, an AuthorizationException exception is thrown, with a message text explaining that a log on is required. Information 5.14.01 Eventlog.MessageWritten now works on Chinese system There was a problem with listening to the event Eventlog.MessageWritten on a controller with Chinese language (culture code zh ). This has now been corrected.

12/15 Creating a single installer for a PC SDK application using InstallShield Limited Edition using Custom Action Using InstallShield 2010 Limited Edition and Visual Studio 2010, you can create an installer that installs both your PC SDK application and the Robot Communication Runtime. This means you can deliver one installer to your customers instead of two. This solution makes use of a Custom Action in InstallShield which launches the embedded Robot Communication Runtime redistributable installer. Please refer to this post in the Developer Tools User Forum for more details: http://www.robotstudio.com/forum/forum_posts.asp?tid=5047&sid=139z8358c3d31 3778a61366bzec384fc Information 5.14 Memory leakage in PC-SDK (DSE10353) A memory leak in the PC SDK method Controller.Rapid.GetRapidData() has been corrected. No simple installation for PC SDK apps because msm file RCR (DSE10406) The Robot Communication Runtime is at present not available as a merge module (.msm file), only as a separate installer. If you are creating an installer for an application built with PC SDK, it is not possible to let it install the Robot Communication Runtime. The Robot Communication Runtime must first be installed on the target computer, using the separate installer, which can be found in the Redistributable folder of the PC SDK installation. Information 5.13.02 PC SDK exception in AWPP when running on Windows 7-64 bit (DSE9926) PC SDK can now handle parenthesis in the system or release folders, e.g. "Program Files (x86)". Previous versions throw an exception. Parameter values for x- p- and i-start missing in Restart com (DSE10140) From revision 5.13.02 is it possible to do a I-Start via PC SDK. A new enum value, IStart, has been added to the enum ControllerStartMode. E.g. using (Mastership.Request(m_controller.Rapid)) using (Mastership.Request(m_controller.Configuration)) { m_controller.restart(controllerstartmode.istart); } PCSDK 5.13.255.0 Evenlog Class (DSE1069) This is now corrected.

13/15 Information 5.13.01 Connect when controller is in SYS_FAIL state (DSE9830) A bug in PC SDK 5.13 makes it impossible to connect to a controller which is in sys-fail state. This has now been corrected. Information 5.13 It is now possible to access RAPID data that are declared in hidden modules and in hidden tasks. E.g RapidData data; Controller controller; // Access data declared in a hidden task. // A hidden task has the -hidden attribute defined in the Controller Configuration. data = controller.rapid.getrapiddata("hidden_task", "module1", "num1"); // Access data declared in a hidden module // A hidden module has the -hidden attribute defined in the Controller Configuration. data = controller.rapid.getrapiddata("t_rob1", "hidden_module1", "num2"); // Access data declared in a shared hidden module // A shared hidden module has the -hidden and the -shared attributes defined in the Controller Configuration. data = controller.rapid.getrapiddata("num3"); // Access data declared in an installed module // An installed module is loaded from a install script using the -install option. data = controller.rapid.getrapiddata("t_rob1", "#SYS", "num4"); // Access data declared in an installed hidden module // An installed module is loaded from an install script using the -install and -hidden options. data = controller.rapid.getrapiddata("t_rob1", "#SYS", "num5") Simulate physical setting of input signals on a Virtual Controller It is now possible to simulate the physical setting of the value of an input signal. The previously existing method to set the value of a signal is similar to setting a signal from RAPID. Depending on the Access Level the controller safety system may or may not allow the signal value to be changed. When a physical signal is set by connecting it to +24V the controller cannot prevent it from happening, no matter what Access Level the signal has. By setting the property InputAsPhysical on the Signal class, a subsequent write operation will simulate a physical write. This is important in a scenario where a PC SDK application shall set signal values in order to verify a RAPID program in a Virtual Controller Dnum variable not accessible from PC SDK (DSE9020) It is now possible to access RAPID dnum variables via PC SDK. A new class Dnum has been added. 32 bit group signals is now supported by the PC SDK. (DSE9386) 32 bit group signals is now supported by the PC SDK. Memory leak (DSE9493) There was a memory leak in PCSDK when retrieving ipc messages. It leaked about 400 bytes per message it retrieves, this has now been corrected.

14/15 Corrected Issues 5.14.03 Old PC SDK Apps not working with/against RW5.14.02 PDD PDD308 Corrected Issues 5.14.02 No corrected issues. Corrected Issues 5.14.01 RobotStudio installation removes 5.13 SDK files ControllerFileSystemInfo.Exists throws exception PC SDK CapiDevTest Update No simple installation for PC SDK apps because msm file RCR is missing UIInstructionEvent does not support more than 4 lines Comma in UIMessageBox text is interpreted as newline PDD PDD DSE10707 Forum DSE10702 DSE10406 Forum Forum Corrected Issues 5.14 Memory leakage in PC-SDK PDD DSE10353 Corrected Issues 5.13.02 PC SDK exception in AWPP when running on Windows 7-64 bit Parameter values for x- p- and i-start missing in Restart com PCSDK 5.13.255.0 Evenlog Class PDD DSE9926 DSE10140 DSE10169 Corrected Issues 5.13.01 Connect when controller is in SYS_FAIL state PDD DSE9830 Corrected Issues 5.13 PDD Dnum variable not accessible from PC SDK DSE9020 32 bit group signals is now supported by the PC SDK. DSE9386 Memory leak DSE9493

15/15 Known Limitations PC SDK UIInstructionEvent / RAPID UIListView - if you are using characters like double quote ( ) and brackets ([ ]) in the RAPID array of list item strings, the UIListViewEventArgs.ListItems may return the wrong number of list items. Avoid using double quote ( ) and brackets ([ ]). In manual mode, when a PC SDK application releases master and immediately requests master again, the FlexPendant is locked up when the user presses the prompt to grant write access to the PC SDK application. In automatic mode there is no problem. PC SDK IPC Messaging - the PC SDK erratically ALWAYS sends 444 byte. Data must therefore be null terminated. Also, there is a problem reading the data if the PC SDK thread is running as STA. Changing it to MTA will solve that problem. The property IsLocal on the class RapidData, returns true for shared data, even though such data is visible from all modules. The declarations of default zonedata and speeddata has been moved from module BASE.SYS in each task, and are now installed as shared data. If an application used to create a RapidData object representing for example "v1000", the IsLocal property returned false in RobotWare 5.12, but will return true in RobotWare 5.13." Product Support For technical support please turn to your local ABB office. http://www.abb.com/contacts For help, advice and the latest updates please visit the User Forum. http://www.robotstudio.com/forum