Model 88C Resistivity Meter Instruction Manual

Similar documents
Electrical Stability Tester, Model 23E Instruction Manual Manual No , Revision B Instrument No

Methylene Blue Kit Instruction Manual

ExStik TM ph Waterproof Meters

3 WATT LED SPOTLIGHT Model No. SLM

12 Volt 30 Amp Digital Solar Charge Controller

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Manual Ranging MultiMeter

ATS Overhead Table Shelf System INSTRUCTION MANUAL

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Instruction Manual Temp 4/5/6 Temperature Meter Series

CappController Pipette Controller. Operation Manual Version:

SunMaxx Solar Filling Station Operating Instructions

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Advantium 2 Plus Alarm

Hygro-Thermometer + InfraRed Thermometer Model RH101

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

How To Use A Cdm250 Digital Multimeter

NFC Communication Tray Model: HHX-IT3-Z

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Relative Humidity Calibration Kit

Installation Instructions

CLEARSENSE - H 2 S Direct-Read Dosimeter For passive monitoring of hydrogen sulfide (H 2 S)

Global Water Instrumentation, Inc.

Periodic Verification System Model 775PVS

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

Wall-Mounting your HP computer. User Guide

AutoRanging Digital MultiMeter

OPERATING INSTRUCTIONS

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

Bottom Loading Water Dispenser

RT-200 HI-TEST ROPE TESTER

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Compaq Presario Desktop Products. Upgrading and Servicing Guide

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Battery Charger. Instruction Manual G

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Care and use guide. Contents. a handy solution made easy. page

Model 349KLX Remote Display Digital Scale User Instructions

Nokia Wireless Keyboard (SU-8W) User Guide

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Ultrasonic Distance Meter. Operation Manual

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Single Station Remote Alarm

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Part I - Installation

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

INSTALLER S & OWNER S MANUAL

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

National- Spencer Inc.

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Li Battery Pack & Charger Safety & Operating Instructions

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Atomic Alarm Clock model 13131W2

Wireless Indoor/ Outdoor Thermometer

BroadBand PowerShield. User Manual

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Model 5101, 5102, 5103SL, 5110, 5111, 5115 STEEL SECURITY SAFE. Read this manual carefully and never store it inside the safe!

EzFlex Combustible Gas Leak Detector Model EZ40

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

Outlines: Original Artwork: LeMaitre. Light Post Adapter. Light Post Adapter. Fits Olympus, Storz, and Stryker Equipment* English Instructions for Use

Installation and Operating Instructions (for chargers shown below)

2-Way Wireless Indoor Siren Installation Guide

MODEL G300 BRAKE BLEEDER

75th anniversary blender

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Customer Support

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

62 Max/62 Max + Infrared Thermometer

Nokia Bluetooth Headset BH-118 User Guide

HVAC Clamp Meter. Users Manual

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

PART 1 - INTRODUCTION...

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

User Manual (English)

Care and use guide. Contents. a handy solution made easy. page

7 High-Resolution Digital Photo Frame

Instructions & Safety Information Models A220-20D and A220-20L Version 2

About this Manual. Support for Your Product

Threaded Inline Air Heaters

CIC-50. T1/E1 G.703 Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EFData CDM-550/550T Modems)

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

High Temperature InfraRed Thermometer with Laser Pointer

4.3-inch Back-Up Camera

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Microwave Meter. Instruction Manual

12-Volt 10-Amp Regulated Power Supply

Installation and Operation Manual

Transcription:

Model 88C Resistivity Meter Instruction Manual Manual No. 207980, Revision E Instrument No. 207960

Model 88C Resistivity Meter Instruction Manual 2014 Fann Instrument Company Houston, Texas, USA All rights reserved. No part of this work covered by the copyright hereon may be reproduced or copied in any form or by any means (graphic, electronic, or mechanical) without first receiving the written permission of Fann Instrument Company, Houston, Texas, USA. Printed in USA. The information contained in this document includes concepts, methods, and apparatus which may be covered by U.S. Patents. Fann Instrument Company reserves the right to make improvements in design, construction, and appearance of our products without prior notice. FANN and the FANN logo are registered trademarks of Fann Instrument Company in the United States and/or other countries. All other trademarks mentioned in the operating instructions are the exclusive property of the respective manufacturers. Contact Fann Instrument Company Phone 1-281-871-4482 1-800-347-0450 Fax 1-281-871-4358 Postal Address Fann Instrument Company P.O. Box 4350 Houston, Texas, 77210 USA Shipping Address Fann Instrument Company 14851 Milner Road, Gate 5 Houston, Texas, 77032, USA Online www.fann.com fannmail@fann.com 207980 Revision E, July 2014 2

Table of Contents 1 Introduction... 4 1.1 Document Conventions... 4 2 Safety... 6 2.1 Battery Safety... 6 3 Features and Specifications... 7 4 Operation... 9 4.1 Fluid Samples... 9 4.2 Semisolid Samples... 10 5 Troubleshooting and Maintenance... 12 5.1 Calibration... 12 5.2 Battery Replacement... 12 5.3 Cleaning... 13 6 Parts List... 14 7 Warranty and Returns... 15 7.1 Warranty... 15 7.2 Returns... 15 List of Figures Figure 3-1 Resistivity Meter, Model 88C... 8 Figure 4-1 Resistivity Chart for NaCl Solutions... 11 List of Tables Table 3-1 Resistivity Meter, Model 88C Specifications... 7 Table 3-2 Range of Environmental Conditions... 7 Table 6-1 Model 88 Resistivity Meter Included Parts... 14 Table 6-2 Optional Equipment... 14 207980 Revision E, July 2014 3

1 Introduction The Model 88C Resistivity Meter measures the resistivity of fluids, slurries, and semisolids according to API Recommended Practice 13B-1. Field and laboratory personnel rely on this instrument to evaluate formation characteristics from electric logs. Resistivity is the ability of a material to resist conduction; conductivity is the reciprocal of resistivity. 1.1 Document Conventions The following icons are used as necessary in this instruction manual. NOTE. Notes emphasize additional information that may be useful to the reader. CAUTION. Describes a situation or practice that requires operator awareness or action in order to avoid undesirable consequences. MANDATORY ACTION. Gives directions that, if not observed, could result in loss of data or in damage to equipment. WARNING! Describes an unsafe condition or practice that if not corrected, could result in personal injury or threat to health. ELECTRICITY WARNING! Alerts the operator that there is risk of electric shock. 207980 Revision E, July 2014 4

HOT SURFACE! Alerts the operator that there is a hot surface and that there is risk of getting burned if the surface is touched. EXPLOSION RISK! Alerts the operator that there is risk of explosion. 207980 Revision E, July 2014 5

2 Safety Safe laboratory practices and procedures should be observed while operating and maintaining the Model 88C. 2.1 Battery Safety On nine volt batteries, the positive and negative terminals are on the same end, next to each other. If these terminals touch anything metal, such as steel wool, coins, or a paper clip, a short circuit could occur, creating heat, sparks, a fire, or an explosion. Nine volt batteries can explode if they are stored in a hot location, charged improperly, or if the terminals contact metal, creating a short circuit. Some batteries contain toxic or corrosive material, which can leak if the battery is damaged. Store unused 9-volt batteries in their original packaging, a sealed plastic container, or securely cover both terminals to prevent short circuits. Do not charge rechargeable batteries before storing them. Store batteries at or below 70 o F (21 o C). 207980 Revision E, July 2014 6

3 Features and Specifications The Model 88C can measure resistivity in three ranges 0.01 to 2, 0.1 to 20, and 1.0 to 200 ohm meters. The ohm-meter reading can be converted into parts per million sodium chloride (or equivalent calcium chloride, potassium chloride or other carbonate or hydroxyl salts) using the resistivity chart (Figure 4-1). This instrument can be operated by its own batteries or by a battery eliminator (P/N 101710234). The Model 88C has these features: Direct digital readout in ohm-meters Built-in temperature probe Low battery indicator Test Button for calibration Table 3-1 Resistivity Meter, Model 88C Specifications Category Meter Range Meter Dimensions (Height x Width x Length) Carrying Case Dimensions (Height x Width x Length) Weight Power Supply Specification 0.01 to 200 ohm-meters 2.8 x 5.1 x 8.3 inches 7.1 x 13 x 21 centimeters 9 x 3.5 x 7.9 inches 22.9 x 8.9 x 20.1 centimeters 4 lb (1.8 kg) 4 x 9V alkaline batteries Table 3-2 Range of Environmental Conditions Maximum Altitude 6562 ft (2000 m) Temperature Range 41 o F to 104 o F (5 o C to 40 o C) Maximum Relative Humidity (RH) 80% RH at 87.8 o F (31 o C) or less 50% RH at 104 o F (40 o C) 207980 Revision E, July 2014 7

Sample Cell Figure 3-1 Resistivity Meter, Model 88C 207980 Revision E, July 2014 8

4 Operation The Model 88C Resistivity Meter can measure resistivity of fluid samples and semisolid samples (e.g., filter cakes or mud solids). Procedures for both types of samples are listed here. The resistivity chart (Figure 4-1) is used to determine the quantity of sodium chloride (in combination with distilled water or other salt-free aqueous medium) that is required to produce a solution with the same resistivity as the sample. The concentration for carbonate salts, calcium salts, and hydroxyl salts can be found in conductance tables for aqueous solutions. 4.1 Fluid Samples This procedure explains how to measure resistivity of liquids, filtrates, and drilling fluids. 1. Remove the sample cell and fill it with the sample. Fill and discharge the sample cell several times before the final fill. To fill use the suction ball to pull sample into the Lucite cell. Make sure there are no bubbles in the sample. 2. Reattach the sample cell onto the pins on the meter. 3. Insert the temperature probe into the sample cell wall. 4. Set the MODE knob to TEMP and let the temperature stabilize. The temperature will stabilize within approximately three minutes if the meter and sample are not at room temperature. 5. Remove the sample cell and clean it with distilled water. If necessary, use a pipe cleaner and mild soap to clean the cell bore. Do not use solvents to clean the cell. 207980 Revision E, July 2014 9

6. Using the resistivity chart (Figure 4-1), convert the resistivity in ohm-meters to concentration of chlorides. 4.2 Semisolid Samples This procedure explains how to measure resistivity of semisolid samples, such as filter cakes and mud solids. 1. Prepare samples of uniform moisture content. 2. Remove the sample cell from the resistivity meter. 3. Completely fill the slot on the outer surface of the cell between the pins with a semisolid sample, making sure the sample connects both pins. 4. Reattach the sample cell onto the pins on the meter. 5. Insert the temperature probe into the sample cell wall. 6. Set the MODE knob to TEMP and let the temperature stabilize. The temperature will stabilize within approximately three minutes if the meter and sample are not at room temperature. 7. Remove the sample cell and clean it with distilled water. If necessary, use a pipe cleaner and mild soap to clean the cell bore. Do not use solvents to clean the cell. 8. Using the resistivity chart (Figure 4-1), convert the resistivity in ohm-meters to concentration of chlorides. 207980 Revision E, July 2014 10

Figure 4-1 Resistivity Chart for NaCl Solutions 207980 Revision E, July 2014 11

5 Troubleshooting and Maintenance Calibration and regular maintenance procedures are described in this section. If more extensive maintenance or service of the instrument is required, please contact Fann Instrument Company. 5.1 Calibration This procedure is a simple method for checking the instrument. A thorough calibration requires a calibration kit. A calibration kit (P/N 210179) is available as a separate purchase. See the parts list for details. 1. Set the MODE knob to RESISTANCE. 2. Set the RANGE knob to 2. 3. Push and hold the TEST button. 4. Observe the reading. The reading should stabilize at 1.800 ± 0.040 ohm-meters. If the reading is not correct, low batteries may be the cause. Replace the batteries and repeat the calibration. If the reading is still not correct, then return the instrument for recalibration. 5.2 Battery Replacement When the battery is low, the digital display will show an arrow pointing to LOW BATT. When the LOW BATT arrow appears, replace the complete set of four 9-volt batteries. Lift the battery tray (back of the instrument) at the slot and pull the battery tray out. When inserting new batteries, make sure the battery terminals are placed as shown on the diagram in the tray. If batteries are inserted incorrectly, they will become damaged. 207980 Revision E, July 2014 12

A battery eliminator (P/N 101710234) is available as a separate purchase. See the parts list for details. 5.3 Cleaning Always clean the cell immediately after making a measurement. Do not use solvents to clean the cell. Avoid scratching the surface of the cell. 1. Purge the cell with distilled water until it is clean. 2. If additional cleaning is necessary, use a pipe cleaner and mild soap. 3. After extensive use, follow these steps to thoroughly clean the cell. a. Soak the cell bore in cleaning solution (P/N 210181) for 2 to 3 hours. b. Scrub it with a pipe cleaner. c. Rinse with distilled water. d. Dry the cell with a clean pipe cleaner. 207980 Revision E, July 2014 13

6 Parts List Table 6-1 Model 88 Resistivity Meter Included Parts Part No. Quantity Description 201057 2 BATTERY HOLDER, 9 VOLT 203623 1 CARRYING CASE 205643 4 BATTERY 9 VOLT 206724 2 KNOB 3/4 DIA X 5/8 HEIGHT w/ 2 SET SCREWS 207262 1 SAMPLE CELL 207263 2 PIN CONTACT MODEL 88C RESISTIVITY METER 207962 1 OVERLAY 88C RESISTIVITY METER 208571 1 JACK POWER PANEL MOUNT 208806 1 CIRCUIT BOARD ASSEMBLY AMPLIFIER 88 208807 1 BOOT SWITCH 204156 1 RED RUBBER BULB, 2ML CAPACITY Table 6-2 Optional Equipment Part No. Description 210441 PIPE CLEANERS, 20/PKG 210179 RESISTIVITY CALIBRATION KIT* 210181 CLEANING SOLUTION, 4 OZ. 210182 STANDARD RESISTIVITY SOLUTION, 4 0Z. 101710234 BATTERY ELIMINATOR, 115/230V *Calibration Kit includes pipe cleaners, cleaning solution, and standard resistance solution. 207980 Revision E, July 2014 14

7 Warranty and Returns 7.1 Warranty Fann Instrument Company warrants only title to the equipment, products and materials supplied and that the same are free from defects in workmanship and materials for one year from date of delivery. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED OF MERCHANTABILITY, FITNESS OR OTHERWISE BEYOND THOSE STATED IN THE IMMEDIATELY PRECEDING SENTENCE. Fann's sole liability and Customer's exclusive remedy in any cause of action (whether in contract, tort, breach of warranty or otherwise) arising out of the sale, lease or use of any equipment, products or materials is expressly limited to the replacement of such on their return to Fann or, at Fann's option, to the allowance to Customer of credit for the cost of such items. In no event shall Fann be liable for special, incidental, indirect, consequential or punitive damages. Notwithstanding any specification or description in its catalogs, literature or brochures of materials used in the manufacture of its products, Fann reserves the right to substitute other materials without notice. Fann does not warrant in any way equipment, products, and material not manufactured by Fann, and such will be sold only with the warranties, if any, that are given by the manufacturer thereof. Fann will only pass through to Customer the warranty granted to it by the manufacturer of such items. 7.2 Returns For your protection, items being returned must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Fann will not be responsible for damage resulting from careless or insufficient packing. Before returning items for any reason, authorization must be obtained from Fann Instrument Company. When applying for authorization, please include information regarding the reason the items are to be returned. Our correspondence address: Fann Instrument Company P.O. Box 4350 Houston, Texas USA 77210 Telephone: 281-871-4482 Toll Free: 800-347-0450 FAX: 281-871-4446 Email fannmail@fann.com Our shipping address: Fann Instrument Company 14851 Milner Road, Gate 5 Houston, Texas USA 77032 207980 Revision E, July 2014 15