ion Genesis Pump Controller

Similar documents
Advantium 2 Plus Alarm

Single Station Remote Alarm

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

7 High-Resolution Digital Photo Frame

For Models #6-5001, #6-7501, # & #10-12K1

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

VK-250 WARRANTY REGISTRATION FORM

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Residential Standby Extended Warranty Statements

Leak Detection System

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Automatic Phone-Out Home Monitoring Systems

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Wireless Phone Jack System

Caller-ID on your TV!

, User s Manual

OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD

Liquid Carbon Balanced Transportable Headphone Amplifier. Cavalli audio. Copyright Cavalli Audio, LLC All Rights Reserved

Ceiling Mount Air Handler Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

Model Owner s Manual. Español - P. 19 Français - P. 39

24.2L M.A.N. V12 Engine Module

User Manual (English)

Universal Laptop Charger

Wireless Indoor/ Outdoor Thermometer

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Back-UPS Pro 1300/1500 Installation and Operation

Mini Power Bank and Charger

IR Repeater. Operation Manual P8620

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

U.S. COMMUNITIES EQUIPMENT SALE AND MAINTENANCE AGREEMENT (EQUIPMENT SALES, BREAK-FIX SERVICES WITH NO ON-SITE LABOR)

BroadBand PowerShield. User Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

Installation and Operation Back-UPS 1250, 1300, 1500

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Intelli-Time Alarm Clock model 13027

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

1 For All Non-Programmable Digital Thermostat

12-Volt 10-Amp Regulated Power Supply

LCD5500Z / PKP-LCD v3.x Installation Instructions

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

CA-125 Owner's Manual

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

Ultrasonic Distance Meter. Operation Manual

Weather Radio Alarm Clock

hello. welcome to smart watering.

RT-200 HI-TEST ROPE TESTER

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

User and Installation Guide

Security Auto Dialer. Owner s Manual. Please read before using this equipment.

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide.

INSTRUCTION MANUAL MODEL PCD-88

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a


Powerware Relay-Serial Card User s Guide

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

Wireless Phone Jack System

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

P O W E R S U P P L Y M A N U A L

User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC /120/230 Vac. Tower/Rack-Mount 1U

LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Nest Learning Thermostat Installation Guide. Installation step-by-step

Utility Distribution Systems

Wireless Home Security System Product Manual (Model #80355)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Alarm Clock USER GUIDE

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Owner s Instruction Manual. 2500/2554 Telephones Message Waiting

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

16/32 Channel 1U Rack Mount CCTV Power Supply

TERMS AND CONDITIONS

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Laptop Power Adapter for home/office User Manual

DCX300 - DCX400 - DCX600

PC Tab Security System INSTRUCTION MANUAL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Alarm Clock USER GUIDE

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Transcription:

Document No.: IONG-OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2 Setup.................................... 3 Operation.............................. 3 Troubleshooting......................... 4 Accessories...........................4 Specifications.............................. 4 Safety Precautions WARNING: To prevent fire or shock hazard, do not expose this product to rain or moisture. This product has a NEMA-1 rated enclosure for use in an indoor environment. Never spill liquid of any kind on the product. CAUTION: Risk of electric shock. To reduce risk of electric shock, do not remove cover. There are no user serviceable parts inside. Refer servicing to qualified service personnel. CAUTION: To prevent electric shock, ensure product is connected to a grounded outlet. The electrical outlet should be properly wired to a dedicated 15-amp circuit breaker. Proper short-circuit and overload protection must be provided at the distribution panel. Install in accordance with all local and national electrical codes. Recommended mounting is above floor level. For best performance, do not use electrical extension cords. General Overview Patent pending The ion Genesis is a residential sump pump controller for 1 or 2 pumps that includes redundant water level sensors, a configurable water level/pump turn-on setting, 2-pump alternation, pump failure sensing, local audible/visual alarm notification, and optional remote alarm notification. This product is for use with manual pumps only. A manual pump is a pump that runs when plugged into an outlet. Sensors are supplied with this unit for control. Indicators The front panel has lights, a display, and a sounder to offer direct feedback to the homeowner. Buttons The front of the controller has buttons labeled RESET/ TEST and PUMP TURN ON LEVEL. The RESET/TEST button has two functions and may be depressed while no pumps are running. When pushed, it runs the first pump temporarily, followed by the second pump if it exists. This can be used for pump troubleshooting, and the controller will remember how many pumps are available for future use. This button must be pushed once after removing or adding any pumps. The PUMP TURN ON LEVEL buttons set the water level at which the pump(s) turns on. This level is measured in inches, up from the middle of the lower water sensor (see the Installation section). When the water level is pumped down to the middle of the lower water sensor, the running pump is turned off. This setting only pertains to the lower water level sensor.

Document No.: IONG-OM Page 2 of 7 Installation Figure 1 1) See Figure 1. Clamp the two water sensors to any head pipes in the sump pit, one water sensor above the other with one near the bottom of the pit and one near the top. The bottom water sensor must be mounted above all pump intakes and will be used for day-to-day operation; the top one will be used as a backup for high water level sensing. Again, note that when the water is pumped down to the middle of the lower water sensor, the running pump will turn off. If the water rises to the middle of the top water sensor, the controller will cue audible, visual, and any remote alarms. HIGH WATER ALARM LEVEL HIGH WATER SENSOR 2) Mount the controller box to the wall in a place where its cord can reach a dedicated 120-volt AC electrical outlet (rated for at least 15 amps), and where the water sensors and sump pumps cords can reach the controller box. 3) See Figure 2. Connect the water sensors to the controller box, ensuring that each sensor plugs into its correct connector. The lower sensor plugs into the jack labeled DIGITAL LEVEL SENSOR and the higher sensor plugs into the jack labeled HIGH WATER SENSOR. 4) Plug a pump into the outlet marked PUMP 1 on the controller box. If there is a second pump, plug it into the outlet PUMP 2 on the controller box. PUMP OFF LEVEL PRIMARY PUMP Figure 2 DIGITAL LEVEL SENSOR OPTIONAL 2ND PUMP 5) In the event that the water level reaches the middle of the HIGH WATER SENSOR, audible and visual notifications will be initiated, and the REMOTE ALARM CONTACTS will be electrically opened, allowing external alarm systems (such as a home alarm) to be activated. If the ion Genesis is not to be connected to an external alarm system, proceed to step 6. If connecting a home alarm system to the ion Genesis, make the connection to the RJ-11 jack labeled REMOTE ALARM CONTACT. The centermost pins (3 and 4) are used for this circuit, and are short-circuited under normal conditions. If water reaches the HIGH WATER SENSOR, an internal relay will electrically break, putting an infinite resistance between pins 3 and 4, notifying the external alarm system. DIGITAL LEVEL SENSOR REMOTE ALARM CONTACTS HIGH WATER SENSOR 6) Proceed to the Setup section.

Document No.: IONG-OM Page 3 of 7 Setup Plug the controller box into the electrical outlet. The controller will automatically sense the connected pumps at this time by running them briefly. If they do not run, push the RESET/TEST button to ensure the controller counts each pump plugged into it. (Each pump must run temporarily for it to be counted.) If they still do not run, call for service. Using the PUMP TURN ON LEVEL buttons, set the desired water level at which the pump should turn on. This level is measured in inches, up from the middle of the lower water sensor ( DIGITAL LEVEL SENSOR, see Figure 1). When the water level is pumped down to the middle of the lower water sensor, the pump is turned off. Note that this setting only pertains to the lower water level sensor, and will be retained in memory in the event of a complete power failure. It is recommended that the system be tested by filling the sump pit with water using a hose. The first pump should turn on and empty the pit of water. If a second pump is installed, filling the pit again should cause the second pump to run. A level sensor failure has been detected A pump has been continuously running but the water level remains above the DIGITAL LEVEL SENSOR for an extended period of time Once in an alarm state, the controller will notify the homeowner that there may be trouble by: Initiating audible and visual cues If the alarm is caused by a high water level, the controller will break (electrically open) the remote alarm contacts, which may be connected to another device installed in the home Typical Installation ION GENESIS CONTROLLER To test the alarm functions, simply apply gentle pressure with a finger to the underside of the top level sensor (HIGH WATER SENSOR). The controller should cue audible and visual alerts, and engage any alarm dialers and/or external devices that may be connected for remote notification. Operation The controller will turn a pump on whenever the sump s water level rises above the height that was configured in the Setup section. That pump will be turned off after the water is pumped down to the middle of the lower water sensor (DIGITAL LEVEL SENSOR). If there is a second pump installed, it will be put on deck and will be run the next time a pump is called for. This alternation keeps wear even between the pumps over time. Due to residential wiring limits, only one pump will be run at a time by the controller. Under any of the following conditions, the controller will enter a state of alarm: A pump failure has been detected The water level reaches the HIGH WATER SENSOR WATER LEVEL SENSORS PUMPS Figure 3

Document No.: IONG-OM Page 4 of 7 Troubleshooting Symptom Cause Measures Power light not illuminated and display is blank. Tripped breaker. Faulty outlet. Reset breaker. Check outlet/wiring. Pump(s) run but will not pump down water. Basin empty but pump won t shut off. Restricted pump or pipe. Failing pump. Bad check valve. High flow. The DIGITAL LEVEL SENSOR is mounted too low in the basin. Clear pump or pipe. Compare water output to similar pump. Check for proper operation of check valve. Pump(s) undersized for incoming water flow, replace with higher capacity pump(s). The lower sensor (DIGITAL LEVEL SENSOR) must be mounted above all pump intakes. Remount sensor higher. Remote contacts not working. Faulty wiring. Use ohmmeter to test continuity of terminals. You should see continuity in normal operation, activate high water alarm - you should measure an open. Consult a qualified electrician for all wiring problems. Display shows 5 Minute Run Fault. Display shows Pump Failed To Start. A pump has been needed for longer than 5 minutes straight. Pump(s) is at least temporarily undersized for incoming water flow, the head pipe is restricted, or a pump is failing. A pump s electrical current draw is lower than expected. Watch pit s water level closely, check for any restrictions, or replace pump(s) ensuring that the new pump has proper flow capacity for incoming water flow. If the condition occurs for one pump, replace the failing pump. If it occurs when either pump is called for, this may indicate an internal problem with the ion Genesis; call for service. Display shows Pump Run Current Failure. A pump still is running after it has been turned off. This indicates an internal problem with the ion Genesis and requires immediate service to prevent further damage. Display shows Trending Fault. Display shows Level Sensor Failure. The water level is increasing, even after a pump is turned on. Pump(s) is at least temporarily undersized for incoming water flow, the head pipe is restricted, or a pump is failing. One of the water level sensors is unplugged or failing. Watch pit s water level closely, check for any restrictions, or replace pump(s) ensuring that the new pump has proper flow capacity for incoming water flow. Unplug then reconnect both water level sensors. If condition persists, replace the failing sensor. Display shows High Water. Display shows High Water Sensor Mode. The water level in the pit has reached the HIGH WATER SENSOR. Either a pump(s) is at least temporarily undersized for incoming water flow, the head pipe is restricted, a pump is failing, or the ion Genesis has an internal problem. The DIGITAL LEVEL SENSOR is unplugged, failing, or plugged into wrong jack. Make sure is a pump running. If not, press the RESET/TEST button, and check again. If still not running, call for service. Otherwise check for any restrictions, or replace pump(s) ensuring that the new pump has proper flow capacity for incoming water flow. Unplug then reconnect the DIGITAL LEVEL SENSOR (the lower of the two sensors in the pit) into the correct jack. If condition persists, replace it.

Document No.: IONG-OM Page 5 of 7 Accessories Increase your protection with the following qualified add-on accessories: StormPro Battery backup for AC pumps rated up to 5 amps. SUMPRO For AC pumps rated up to 12 amps. Alarm Phone Dialer Can be programmed with up to nine phone numbers to call in case of high water or other alarm. Specifications Voltage: Capacity: Standby Power Consumption: Remote Alarm Contacts: Temperature Range: Audible Alarm: Enclosure: Dimensions(sensors): Mounting: Dimensions (controller): 120 VAC, 60 Hz 15 amp maximum load per pump outlet (1/2 hp) 7 W maximum Normally closed (Open during alarm state) 30 VAC/DC @ 1A MAX 0 C to 40 C (32 F to 104 F) 80 db at 10 ft. NEMA-1 UL94V-0 Acrylonitrile Butadiene Styrene 4.62 x 4.62 mounting straps: 5.25 x 3.50 Up to #10 screws 8.260 x 3.940 mounting holes For operation or installation instructions for these accessories, call 1-800-323-1665

Document No.: IONG-OM Page 6 of 7 Warranty 1. Coverage and Term. Metropolitan Industries, Inc. ( Metropolitan ) warrants to the original purchaser (the Buyer ) of each Metropolitan product (the product ), that any part thereof which proves to be defective in material or workmanship within one (1) year from date of installation or 18 months from the date of manufacture, whichever comes first, will be replaced at no charge with a new or remanufactured part, F.O.B. factory. Buyer shall be responsible for all freight charges and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof. 2. Exclusions. THE WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS AND EXCLUSIONS: (a) The Warranty excludes products or workmanship which becomes defective as a result of: (i) earthquake, fire, storms, the elements or any other acts of God; (ii) normal wear and tear from use; (iii) accident, misuse, abuse or neglect ; (iv) modifications made by Buyer or any third party, other than Metropolitan; and (v) Buyer s failure to properly install, maintain, service and/or operate the product under normal conditions and according to manufacturer s instructions. (b) Metropolitan shall not be responsible for, and the Warranty shall not cover, extended damage which occurs because of Buyer s failure to notify Metropolitan promptly in writing of apparent defects. (c) Any part or component designated as manufactured by anyone other than Metropolitan shall be covered only by the express warranty of the manufacturer thereof. (d) The Warranty shall lapse upon Buyer s failure to fully comply with the terms and conditions of its contract with Metropolitan, including Buyer s failure to pay the purchase price for the product or any portion thereof. Buyer s subsequent compliance with the terms and conditions of any such contract, will not cause the term of the Warranty to extend beyond the time period set forth above. (e) No actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above. Metropolitan shall not be obligated to remedy any defect, where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above. 3. Process of Claims and Repairs. Metropolitan agrees that if the product or any part or component thereof shall fail to conform to the terms of this Warranty, Metropolitan shall replace such nonconforming product, part or component at the original point of delivery and furnish instruction for its disposition. Any transportation charges involved in such disposition and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof shall be the responsibility of Buyer. 4. Limitation on Liability. Notwithstanding any provision to the contrary, Metropolitan s entire liability under this Warranty shall not in the aggregate exceed, and Buyer s exclusive and sole remedies are, to the extent permitted by law, shall be to secure replacement of the defective product. UNDER NO CIRCUMSTANCES SHALL METROPOLITAN BE LIABLE UNDER THE WARRANTY FOR ANY INDIRECT, PUNITIVE, SPECIAL, EXEMPLARY, CONSEQUENTIAL OR INCIDENTAL DAMAGES (INCLUDING LOST PROFITS, REVENUE, USE OR ECONOMIC ADVANTAGE). 5. Express Waiver of Any Other Warranties. THE EXPRESS WARRANTY SET FORTH IN THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY METROPOLITAN, OR ANY OTHER PARTY, IN CONNECTION WITH ANY PRODUCT PURCHASED FROM METROPOLITAN. NEITHER METROPOLITAN, NOR ANY OTHER PARTY, MAKES ANY OTHER EXPRESS OR IMPLIED WARRANTY WHICH IS NOT SET FORTH HEREIN, AND METROPOLITAN HEREBY DISCLAIMS AND BUYER HEREBY WAIVES ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. 6. Not Transferable. The Warranty may not be transferred and shall be void on the sale or other transfer of the product. 7. Products and Warranty Subject to Change. Metropolitan reserves the right to make revisions to its products and their specifications, and to revise this Warranty and related information without notice.

Document No.: IONG-OM Page 7 of 7 PAGE LEFT INTENTIONALLY BLANK

37 Forestwood Drive Romeoville, IL 60446 815-886-9200 www.metropolitanind.com