Sun StorEdge RAID Manager 6.2.21 Release Notes



Similar documents
Sun StorEdge A5000 Installation Guide

Sun Enterprise Optional Power Sequencer Installation Guide

N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In

Sun Management Center Change Manager Release Notes

Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server

Upgrading the Solaris PC NetLink Software

Optimizing Solaris Resources Through Load Balancing

Service Level Definitions and Interactions

Solaris 10 Documentation README

Sun Enterprise 420R Server Product Notes

Sun StorEdge N8400 Filer Release Notes

Scrubbing Disks Using the Solaris Operating Environment Format Program

Sun StorEdge T3 Dual Storage Array - Part 1

SunFDDI 6.0 on the Sun Enterprise Server

Comparing JavaServer Pages Technology and Microsoft Active Server Pages

Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance

Solaris Bandwidth Manager

Sun Management Center 3.6 Version 5 Add-On Software Release Notes

Solaris 9 9/05 Installation Roadmap

Java Dynamic Management Architecture for Intelligent Networks

Service Level Agreement in the Data Center

Exploring the iplanet Directory Server NIS Extensions

JumpStart : NIS and sysidcfg

LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software

Reducing the Backup Window With Sun StorEdge Instant Image Software

Sun TM SNMP Management Agent Release Notes, Version 1.6

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Important Note on New Product Names

Sun StorEdge Enterprise Backup Software 7.2

Sun Management Center 3.5 Update 1b Release Notes

Sun Fire 6800/4810/4800/3800 Systems Software Release Notes

Managing NFS Workloads

Power Savings in the UltraSPARC T1 Processor

HelloWorld SOAP Sample:

Disaster Recovery Requirements Analysis

Sun Fire 6800/4810/4800/ 3800 Systems Product Notes

Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes

Developing a Security Policy

Sun StorEdge RAID Manager 6.22 User s Guide

Sun SNMP Management Agent Release Notes, Version 1.5.5

Sun Management Center 3.6 Version 4 Add-On Software Release Notes

Rapid Recovery Techniques: Exploring the Solaris Software Registry

SCSI Sense Key Error Guide

N1 Grid Engine 6 Release Notes

Sun Grid Engine Release Notes

RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array

Consolidation in the Data Center

Sun Fire B10n Content Load Balancing Blade Product Notes

Rapid Recovery Techniques: Auditing Custom Software Configuration

Service Level Management in the Data Center

Solaris Resource Manager

The UltraSPARC T1 Processor - High Bandwidth For Throughput Computing

Sun StorEdge Instant Image 3.0 and Oracle8i Database Best Practices

The Solaris Fingerprint Database - A Security Tool for Solaris Operating Environment Files

Brocade SilkWorm 4100 FC Switch Release Notes

Sun Fire 6800/4810/4800/3800 Systems Firmware Release Notes

Data Center Design Philosophy

Solaris 9 Installation Roadmap

Java Management Extensions SNMP Manager API

Sun StorEdge SAN Foundation Release Notes

Sun Microsystems, Inc Garcia Avenue Mountain View, CA FAX

Netra Data Plane Software Suite 2.0 Update 2 Release Notes

Automating Centralized File Integrity Checks in the Solaris 10 Operating System

Sun Remote System Control (RSC) Installation Guide

Sun Ray, Smart Cards, and Citrix

SunPCi Supporting Highly Available PC Applications with Solaris

Sun StorEdge network FC switch-8 and switch-16 Release Notes

Trust Modeling for Security Architecture Development

Sun Fire V480 Server Product Notes

Distributed Application Management using Jini Connection Technology

Sun 450 MHz UltraSPARC -II Module Upgrade

Sun Fire Midframe Server Best Practices for Administration

Sun Blade 1500 Workstation Product Notes

Brocade 5300 Switch Hardware Release Notes

Sun Fire V20z Server Release Notes

Sun Ray Server Software 3 Release Notes

Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0

Brocade 300 Switch Hardware Release Notes

Netra X4200 M2 Server Site Planning Guide

Sun Blade 100 and Sun Blade 150 Workstations

MIGRATION WHITEPAPER MIGRATING FROM MICROSOFT OFFICE TO OPENOFFICE.ORG OR STAROFFICE 9

Solaris Volume Manager Administration Guide

Operations Management Capabilities Model

A Strategy for Managing Performance

Sun StorEdge FC-100 Long Wave Gigabit Interface Converter Guide

Using Linux mdadm Multipathing with Sun StorEdge Systems

Platform Notes: The SunHSI/P Device Driver

Sun Cobalt Control Station. Using the LCD Console

Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide

Getting StartedWith Sun Java System Application Server 9.1 Update 2

Sun Ray Connector for Windows OS, Version 2.1 Release Notes

Transcription:

Sun StorEdge RAID Manager 6.2.21 Release Notes formicrosoftwindowsnt Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-6890-11 November 1999, Revision A Send comments about this document to: docfeedback@sun.com

Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 USA. All rights reserved. Portions copyright 1999 LSI Logic, Inc. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and other countries, exclusively licensed through X/Open Company, Ltd. For Netscape Communicator, the following notice applies: Copyright 1995 Netscape Communications Corporation. All rights reserved. Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, Solaris, RSM, and StorEdge are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-14(g)(2)(6/87) and FAR 52.227-19(6/87), or DFAR 252.227-7015(b)(6/95) and DFAR 227.7202-3(a). DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON- INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 Etats-Unis. Tous droits réservés. Des portions de ce produit sont protégées par un copyright (1999) de LSI Logic, Inc. Tous droits réservés. Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d autres pays et licenciée exclusivement par X/Open Company, Ltd. La notice suivante est applicable à Netscape Communicator : Copyright 1995 Netscape Communications Corporation. All rights reserved. Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, Solaris, RSM, et StorEdge sont des marques de fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface d utilisation graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique. Sun détient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox, cette licence couvrant également les licenciés de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun. CETTE PUBLICATION EST FOURNIE "EN L ETAT" ET AUCUNE GARANTIE, EXPRESSE OU IMPLICITE, N EST ACCORDEE, Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE, L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE, OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS. CE DENI DE GARANTIE NE S APPLIQUERAIT PAS, DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU. Please Recycle

Introduction This document contains important information for installing and using the Sun StorEdge RAID Manager 6.2.21 software for the Microsoft Windows NT platform. Table of Contents These Release Notes contain the following information: New Files on the RAID Manager CD page 2 Installing RAID Manager 6.2.21 page 2 Upgrading to RAID Manager 6.2.21 page 3 Firmware Specifications page 4 Replacing Controllers page 5 Overview of Open Issues page 6 Open Issues page 7 1

New Files on the RAID Manager CD The following table shows the files that have been added to the /firmware directory on the Sun StorEdge RAID Manager 6.2.21 CD. File Name fwcompat.def.update_1 03.00.11.32.bwd 03.00.11.33.apd Description The integration of the 03.00.11.32.bwd and 03.00.11.33.apd code names for the online or offline firmware download operation. The bootware code to support 3621A controllers. The appware code to support 3621A controllers. Refer to the Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Windows NT (805-6888-10) for complete instructions on how to install the Sun StorEdge RAID Manager software. Installing RAID Manager 6.2.21 Perform the following procedure to install Sun StorEdge RAID Manager 6.2.21 for the first time. To complete this procedure, you need: Sun StorEdge RAID Manager 6.2.21 CD Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Windows NT (805-6888-10). 1. Follow the installation procedures as described in the Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Windows NT. After completing and verifying the installation of RAID Manager, go to step 2. 2. Copy the following files from the /firmware directory on the RAID Manager 6.2.21 CD to the /Program Files/Raidmgr/Lib directory: fwcompat.def.update_1 03.00.11.32.bwd 03.00.11.33.apd 3. As a precaution, rename the existing fwcompat.def file in the /Lib directory to the following name: fwcompat.def.old 2 Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999

4. Rename the fwcompat.def.update_1 file to the following name: fwcompat.def 5. Select and perform either the Online or Offline method to download new controller firmware, and verify that 03.00.11.32.bwd and 03.00.11.33.apd can be selected from the firmware menu. This step completes installation of the RAID Manager 6.2.21 software. Upgrading to RAID Manager 6.2.21 Perform the following procedure to upgrade to Sun StorEdge RAID Manager 6.2.21 from an earlier version of RAID Manager. To complete this procedure, you need: Sun StorEdge RAID Manager 6.2.21 CD Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Windows NT (805-6888-10). 1. Copy the following files from the /firmware directory on the RAID Manager 6.2.21 CD to the /Program Files/Raidmgr/Lib directory: fwcompat.def.update_1 03.00.11.32.bwd 03.00.11.33.apd 2. As a precaution, rename the existing fwcompat.def file in the /Lib directory to the following name: fwcompat.def.old 3. Rename the fwcompat.def.update_1 file to the following name: fwcompat.def 4. Select and perform either the Online or Offline method to download new controller firmware, and verify that 03.00.11.32.bwd and 03.00.11.33.apd can be selected from the firmware menu. This step completes the upgrade procedure Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999 3

Firmware Specifications Refer to Appendix A in the Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Windows NT (805-6888-10) for more on firmware specifications. Latest Controller Firmware Version You should upgrade the controllers to the highest firmware level supported by your current version of RAID Manager. The most recent controller firmware version is: 3.00.11.32.bwd and 3.00.11.33.apd For instructions on upgrading controller firmware version, refer to the Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Windows NT (805-6888-10). Controller Firmware Requirements The RAID Module Controllers that support the RAID Manager 6.2.21 software and the required firmware level for each controller are shown in the following table. Controller Type Required Firmware 3201 2.04.20 does not support 3.0 3620, 3622 2.05.04 or later does not support 3.0 3240, 3621, 3621A 2.05.04, 3.0, or later 4 Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999

Upgrade Notes The following table shows the upgrade path for the controller firmware version on a RAID Module s controllers. If you have this firmware version: You should upgrade to: 2.05.04 to 2.05.05 directly to 3.00.11.32.bwd and 3.00.11.33.apd on both controllers 2.04.04 to 2.05.03 to 2.05.04 then 3.0 2.04.03 to 2.04.04 to 2.05.04 to 2.05.04 Note This software s CD contains firmware versions 2.04.04, 2.05.04, 3.0, and 3.00.11.32.bwd and 3.00.11.33.apd (appware and bootware). Replacing Controllers Chapter 7 in the Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Windows NT (805-6888-10) includes important information you may need to use when replacing failed controllers. Two procedures are described: Problems Bringing the New Controller Online Incompatible Firmware Detected For the Incompatible Firmware Detected procedure, the following information supersedes the existing information on page 7-18. You have replaced a controller and saw a message after the new controller was brought Online telling you that incompatible firmware has been detected and to consult this section. Consult the Sun StorEdge RAID Manager A3x00 Controller Replacement Guide (805-7854), shipped with the controller FRU you received. This manual describes the correct procedures for bringing FRU controllers to operational code levels. If the problem still persists, the recommended procedure is to contact your Customer Services Representative. Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999 5

Overview of Open Issues TABLE 1 summarizes the open issues. The remainder of this document consists of discussions of each issue and recommended workarounds, where known. TABLE 1 Issue Number Open Issues Description 4120457 Fujitsu 9LP and 18G HH serial numbers and date codes are not accurate when viewed through the Module Profile Drives selection. 4150501 List/Locate doesn t light StorEdge D1000 tray LED. 4150513 Health Check does not report redundant power supply or fan tray failure in RSM Array 2000 controller chassis. 4150514 Recovery Guru Help Window does not document all possible causes of power supply failures. 4155147 Configuration Manager window may not refresh with the proper status when the Recovery Guru changes the configuration. 4163706 Firmware download screen does not highlight a selected independent controller or entire RAID Module group. 4160507 CLOSED (duplicate of 4120457) 6 Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999

Open Issues 4120457: Fujitsu 9LP and 18G HH serial numbers and date codes are not accurate when viewed through the Module Profile Drives selection. In the Maintenance and Tuning application, selecting Module Profile Drives reports 0000XX as the serial number for 9LP units and 5000xx as the serial number for 18G units. This is not correct. Solution Verify the disk serial numbers by physically removing the disk unit from the tray. 4150501: List/Locate doesn t light StorEdge D1000 tray LED. If the List/Locate All Drives option is selected for any RAID 0, 1, 3, or 5 set, the resulting activity LED sequence is too fast to be detected and displayed by the StorEdge D1000 tray LED circuitry. However, the LED circuitry is able to properly detect and display this LED activity if disks are in the Unassigned group or are selected individually. Solution To view the disks being located, open the front drive panel of the StorEdge D1000 tray on the StorEdge A3500 or StorEdge A1000 systems and view the drive LEDs directly. or Select individual disks or disks in the Unassigned group. The LED states for these disks cycle ON and OFF in equal time increments, providing ample time for the StorEdge D1000 tray LED to present a visible sequence. Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999 7

4150513: Health Check does not report redundant power supply or fan tray failure in RSM Array 2000 controller chassis. This problem should not occur frequently, due to the high reliability of the power supplies; however, in the event that a second power supply also fails, significant downtime can occur. Solution Monitor the status LEDs of the RSM Array 2000 controller chassis directly. If an RSM Array 2000 chassis power supply or fan failure does occur, the affected status LED will illuminate. 4150514: Recovery Guru Help Window does not document all possible causes of power supply failures. If there is a single-line power failure to a dual AC box, Health Check correctly senses the power failure. The Recovery Guru, however, fails to mention numerous possible causes for the failure, including: The AC box could be faulty The connection could be loose More than one supply could have simultaneously failed The Recovery Guru simply instructs you to replace all failed supplies individually. Solution If you experience multiple power-supply failures, be aware that a potential cause of this is the loss of AC power to the affected area. This is particularly true if all supplies on only one side of each StorEdge A3x00 are reported as failed. 8 Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999

4155147: Configuration Manager window may not refresh with the proper status when the Recovery Guru changes the configuration. If the Configuration Manager window is open when the Recovery Guru makes changes to the configuration (for example, if a controller in a redundant configuration fails, is replaced with a new one, and then is manually activated), the Configuration Manager window is not refreshed. Solution Exit and restart the Configuration application to reflect the current configuration. 4163706: Firmware download screen does not highlight a selected independent controller or entire RAID Module group. When you select an independent controller during the procedure for downloading NVSRAM or firmware files, the firmware download screen does not highlight that controller. Solution Ignore the lack of highlighting and proceed with the download procedure. (That is, select the appropriate files and click OK.) 4160507 CLOSED (duplicate of 4120457) Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999 9

10 Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT November 1999