PorouS PolYethYlene ImPlantS

Similar documents
Cranial/Neurosurgical Implants

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

Titanium Wire with Barb and Needle. For canthal tendon procedures.

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Technique Guide. Norian SRS Fast Set Putty. Calcium phosphate bone void filler.

MatrixNEURO CMF Matrix

Scout Vessel Guard. A hydrogel membrane with exceptional handling characteristics.

MatrixNEURO. The next generation cranial plating system.

PERIPROSTHETIC IMPLANTS

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD

PSI Patient Specific Implants. Derived from CT data for excellent reconstructive results.

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

HUNTER TENDON IMPLANTS

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

(English) NEXUS SPINE SPACER SYSTEM

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Zimmer Small Fragment Universal Locking System. Surgical Technique

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

The information contained in this document is intended for healthcare professionals only.

Knotilus TM. Anchor Instability Repair. Technique Guide

Arizona State University Institutional Animal Care and Use Committee STANDARD INSTITUTIONAL GUIDELINE RODENT SURGERY

IVALON Ophthalmic. IVALON Ophthalmic Products

Retractable Screen. Replacement Screen Instructions

Contraindications: Malign or benign strictures in the upper part of esophagus close to the cricopharyngeal muscle.

Scotchgard Multi-Layer Protective Film 1004

Dental Implant Options in Atrophic Jaws

BONE CEMENT. History, Performance, and Choice TECHNICAL MONOGRAPH

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

CeSpace Titanium / PEEK

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

LCP Compact Foot/Compact Hand.

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

BONE PRESERVATION STEM

Posterior Referencing. Surgical Technique

Why an Exactech Hip is Right for You

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Bard * PerFix * Plug. Technique Guide. A Modified Technique with the. Open Inguinal Hernia Repair

Praxis Technology: Enhancements to Ti-MIM processing bring medical implants a step closer

TriLock 1.5 Implants for the Phalanges

Abdominal Pedicle Flaps To The Hand And Forearm John C. Kelleher M.D., F.A.C.S.

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

IMPLANT MENTOR EFFECTIVE JANUARY 2012 BREAST IMPLANTS NOT FOR DISTRIBUTION IN USA APPROVED FOR EMEA REGION. Mentor Worldwide LLC Rev C

August 21, TCM Associates Ltd Mr. Iain Alligan Technical Director 3 Hillgrove Business Park Nazeing Road Essex EN9 2HB United Kingdom

Lentur Cable System. Surgical Technique

Get the Facts, Be Informed, Make YOUR Best Decision. Pelvic Organ Prolapse

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

Warranty. 1/5. Warranty

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

Zimmer DeNovo NT Natural Tissue Graft

Standard laryngoscope blade assemblies Directions for use

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

CDT 2015 Code Change Summary New codes effective 1/1/2015

How To Fix A Radial Head Plate

The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty

Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D.

Quick Facts about Breast Augmentation with IDEAL IMPLANT Saline-filled Breast Implants

COPYRIGHT ASPS. Breast Augmentation. The Symbol of Excellence in Plastic Surgery

TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.

Ventral Hernia Repair

Outlines: Original Artwork: LeMaitre. Light Post Adapter. Light Post Adapter. Fits Olympus, Storz, and Stryker Equipment* English Instructions for Use

Installation Instructions: (Part # SB76880) XRC Armor Front Fender Kit

Acetabular Wedge Augment System

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

London Farm Kitchen Sinks

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Neuro Closure C A T A L O G

NCB Distal Femur System. Surgical Technique

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Achilles Tendon Repair, Operative Technique

Zimmer Periarticular Proximal Tibial Locking Plate

Instructions for Use

THE MENTOR COMMITMENT

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

MINI IMPLANTS FOR LOWER DENTURE STABLIZATION

Products for. the Oral and Maxillofacial Surgeon CMF

PATIENT SPECIFIC PLATES FOR MANDIBLE: CUSTOM MADE PLATES FOR TRAUMA AND RECONSTRUCTION

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

Brisa UV Gel Enhancements Sculpted on a Tip

V-TEK IVP System 2.7 System 4.0

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

PARALOID KM-1 Acrylic Impact Modifier

Titanium versus Zirconium Implants

Material Comparison Lower Quality Blender Optimum Electric Motor Assembly. Plastic Fans Low cost

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Aestheticare Cosmetic Surgery Institute Dr. Ronald E. Moser Rancho Viejo Rd. San Juan Capistrano, CA (800)

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

WARNING To reduce the risk of. READ ALL INSTRUCTIONS BEFORE USING. KEEP AWAY FROM WATER DANGER Any appliance is

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Plasmax Plasma Concentration System BIOLOGICS

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

1300 West Bartlett Road Elgin, Illinois Phone: (847) Fax: (847) SUBJECT: Pelican NP and NS Cab Glass Replacement

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Transcription:

SYnPor PorouS PolYethYlene ImPlantS For craniofacial and orbital augmentation and reconstruction SurgIcal technique

Table of Contents Introduction SYNPOR Porous Polyethylene Implants 2 Indications and Contraindications 3 SYNPOR Implant Sheets 4 SYNPOR Implant Titanium Reinforced Fan Plates 5 Surgical Technique Handling 6 Sizing 7 Contouring 8 Stabilizing 9 Additional Warnings and Precautions 10 Product Information SYNPOR Implants 11 SYNPOR Porous Polyethylene Implants Surgical Technique DePuy Synthes CMF

SYNPOR Porous Polyethylene Implants SYNPOR Implants are manufactured from an inert, nonabsorbable polymer formulated to contain a network of open and interconnecting pores approximately 100 µm 250 µm in size. These interconnected pores allow fibrovascular tissue ingrowth and relative host incorporation, rather than the host encapsulation observed with smooth-surface implants. 1 SYNPOR Implants are well-suited for craniofacial reconstruction and augmentation. The implant s porous structure promotes tissue ingrowth and results in rapid integration and stabilization. Features Porous structure supports tissue ingrowth Smooth implants have one barrier surface allowing tissue ingrowth on only one side Nonabsorbable and biocompatible material Semirigid material is strong yet flexible Contourable and easily shaped Implants may be fixated with screws, wire, or suture Clinical applications Orbital augmentation and reconstruction Orbital floor/wall Orbital rim Enophthalmos Cranial/skull base augmentation and reconstruction Cranioplasty Calvarial bone graft donor sites Burr hole defects Sellar floor Pterion Mastoid Facial augmentation and reconstruction Malar Genioplasty Mandibular: angle/body/ramus 2 DePuy Synthes CMF SYNPOR Porous Polyethylene Implants Surgical Technique

SYNPOR Porous Polyethylene Implants Material SYNPOR Implants are manufactured from ultra-high molecular weight polyethylene (UHMWPE), which has a long history of use as a surgical implant and meets ASTM standards. 2,3 In addition, SYNPOR Implants have passed ISO standard tests for biocompatibility. 4 Several SYNPOR Implant designs also incorporate titanium mesh constructed from commercially pure (CP) titanium. Indications SYNPOR Porous Polyethylene Implants are intended for use in non-load bearing applications in craniofacial reconstruction, cosmetic surgery, and repair of craniofacial trauma. Contraindications Active or latent infection Inadequate coverage of healthy, vascularized tissue Full load-bearing applications Systemic disorders that cause poor wound healing or may lead to soft tissue deterioration over the implant References 1. Yaremchuk MJ. Facial Skeletal Reconstruction Using Porous Polyethylene Implants. Plastic Reconstr Surg. 2003; 111(6):1818-27. 2. astm F648, Standard Specification for Ultra-High-Molecular Weight Polyethylene Powder and Fabricated Form for Surgical Implants. 3. astm F755, Standard Specification for Selection of Porous Polyethylene for Use in Surgical Implants. 4. ISO 10993, Biological Evaluation of Medical Devices. SYNPOR Porous Polyethylene Implants Surgical Technique DePuy Synthes CMF 3

SYNPOR Implant Sheets SYNPOR Implant Sheets Engineered to maintain an open, interconnected porosity throughout the implant to support tissue ingrowth. SYNPOR Implant Smooth Sheets Implants have a thin layer of solid polyethylene on the superior surface to minimize tissue adhesion and porous polyethylene on the inferior surface to support tissue ingrowth. Radiolucency reduces interference with diagnostic imaging Anatomical shapes, proven through many years of clinical history, allow quick implantation and minimize trimming 50 mm x 50 mm sheets for custom shaping Multiple thicknesses to meet clinical needs Technique tip: For smooth implants, place the smooth side of the implant toward the soft tissue to minimize adhesion and ensure motility of the globe. SYNPOR Implant Square Sheet SYNPOR Implant Smooth Square Sheet SYNPOR Implant Orbital Floor Plate SYNPOR Implant Fan Plate 4 DePuy Synthes CMF SYNPOR Porous Polyethylene Implants Surgical Technique

SYNPOR Implant Titanium Reinforced Fan Plates SYNPOR Implant Titanium Reinforced Fan Plates Porous sheet embedded with the DePuy Synthes CMF fan-shaped 1.3 mm titanium orbital floor plate. SYNPOR Implant Smooth Titanium Reinforced Fan Plates Porous sheet embedded with the DePuy Synthes CMF fan-shaped 1.3 mm titanium orbital floor plate. SYNPOR Implant Smooth Titanium Reinforced Fan Plates provide a barrier to minimize soft tissue adhesion on the superior surface and a porous surface on the reverse side to support tissue ingrowth SYNPOR Implant Titanium Reinforced Fan Plate SYNPOR Implant Titanium Reinforced Fan Plate, with exposed fixation holes Radiographic visibility Increased sheet strength and contour retention Available with titanium mesh partially exposed or completely covered for multiple fixation options Anatomical shape and radial titanium mesh design minimize cutting Polyethylene sheets reduce sharp titanium edges after cutting and facilitate insertion Fixation hole positions allow optimal screw placement Available in two thicknesses: 0.8 mm and 1.5 mm Compatible with 1.3 mm titanium screws Technique tip: For smooth implants, place the smooth side of the implant toward the soft tissue to minimize adhesion and ensure motility of the globe. SYNPOR Implant Smooth Titanium Reinforced Fan Plate SYNPOR Implant Smooth Titanium Reinforced Fan Plate, with exposed fixation holes SYNPOR Porous Polyethylene Implants Surgical Technique DePuy Synthes CMF 5

Handling 1 Handling SYNPOR Porous Polyethylene Implants are provided sterile and pyrogen-free, for single-patient use. Do not resterilize. Do not remove SYNPOR Implants from their packaging until time of implantation. Handle implants with clean, powder-free gloves to prevent contamination. Caution Do not place implants on surgical drapes, surgical clothing, or any other material that may contaminate the implants with lint or other particulate matter. Implants may be placed in sterile saline to prevent contamination. Discard and DO NOT USE previously opened or damaged devices. Use only devices that are packaged in unopened and undamaged packages. DO NOT USE if there is loss of sterility of the device. The implants are intended for SINGLE use only. 6 DePuy Synthes CMF SYNPOR Porous Polyethylene Implants Surgical Technique

Sizing 2 Sizing SYNPOR Implants can be easily cut and sculpted with scissors, mesh cutters, or a scalpel. Thicker implants may be adapted to the surgical site using bone cutters or cutting burrs to achieve the desired shape. If the implant is burred, reestablish the open pore structure by shaving the outer surface with a scalpel. Multiple pieces can be sutured together when thicker or larger implants are required. After sizing the implant, rinse it in sterile saline solution to remove loose particles. Caution Do not place or carve the implant on cloth or any other surface that may contaminate the implant with lint and other particulate matter. The implants are NOT to be modified by any electrosurgery device. SYNPOR Porous Polyethylene Implants Surgical Technique DePuy Synthes CMF 7

Contouring 3 Contouring SYNPOR Implants can be contoured by submerging in hot, sterile saline (over 70 C/160 F) for several minutes until the implant softens. Higher temperatures will improve the ability to contour the implant. Remove the implant from the hot saline and contour to the desired shape. If there is too much resistance, return the implant to hot saline. Allow the implant to cool completely to maintain the achieved shape. Cold, sterile saline can accelerate the cooling process. Reheat the implant as needed to achieve the final form desired. 8 DePuy Synthes CMF SYNPOR Porous Polyethylene Implants Surgical Technique

Stabilizing 4 Stabilizing If desired, implants may be stabilized with screws, wire, or suture. SYNPOR Implant Titanium Reinforced Fan Plates are compatible with 1.3 mm titanium cortex screws. When using screws, tighten them sufficiently to compress the implant to the bone and minimize the screw profile. Make any final modifications in situ. Feather the edges of the implant to create a smooth transition and minimize palpability. Important: Take care to remove all carved debris from the surgical site. SYNPOR Porous Polyethylene Implants Surgical Technique DePuy Synthes CMF 9

Additional Warnings and Precautions SYNPOR Porous Polyethylene Implants are not intended for full load-bearing applications unless used with traditional rigid fixation. The device can break or bend as a result of stress or activity, which could cause failure of the device or the treatment. The surgeon is to be thoroughly familiar with the devices, the method of application, the instruments, and the surgical procedure. The surgeon must select a type or types of internal fixation appropriate for the treatment. Improper selection, placement, positioning, and fixation of the devices can cause subsequent undesirable results. Porous Polyethylene Implants should not be used in areas exposed to the outside environment. The devices can break or be damaged due to excessive activity or trauma. This could lead to failure of the implant construct, which could require additional surgery and device removal. 11 DePuy Synthes CMF SYNPOR Porous Polyethylene Implants Surgical Technique

Product Information SYNPOR Square Sheets, sterile 08.510.110S 50 mm x 50 mm, 0.45 mm thick 08.510.120S 50 mm x 50 mm, 0.8 mm thick 08.510.130S 50 mm x 50 mm, 1.5 mm thick 08.510.140S 50 mm x 50 mm, 3.0 mm thick SYNPOR Smooth Square Sheets, sterile 08.510.220S 50 mm x 50 mm, 0.8 mm thick SYNPOR Orbital Floor Plates, sterile 08.510.540S 24 mm, 0.8 mm thick 08.510.541S 30 mm, 0.8 mm thick 08.510.542S 35 mm, 0.8 mm thick 08.510.543S 24 mm, 1.5 mm thick 08.510.544S 30 mm, 1.5 mm thick 08.510.545S 35 mm, 1.5 mm thick SYNPOR Smooth Orbital Floor Plates, sterile 08.510.640S 24 mm, 0.8 mm thick 08.510.641S 30 mm, 0.8 mm thick 08.510.642S 35 mm, 0.8 mm thick SYNPOR Fan Plates, sterile 08.510.546S 35 mm radius, 0.8 mm thick 08.510.547S 35 mm radius, 1.5 mm thick SYNPOR Smooth Fan Plates, sterile 08.510.646S 35 mm radius, 0.8 mm thick SYNPOR Porous Polyethylene Implants Surgical Technique DePuy Synthes CMF 11

Product Information SYNPOR Titanium Reinforced Fan Plates, sterile 08.520.120S 0.8 mm thick (purple) 08.520.130S 1.5 mm thick (teal) SYNPOR Smooth Titanium Reinforced Fan Plates, sterile 08.520.220S 0.8 mm thick (purple) 08.520.230S 1.5 mm thick (teal) SYNPOR Titanium Reinforced Fan Plates, with exposed fixation holes, sterile 08.520.121S 0.8 mm thick (purple) 08.520.131S 1.5 mm thick (teal) SYNPOR Smooth Titanium Reinforced Fan Plates, with exposed fixation holes, sterile 08.520.221S 0.8 mm thick (purple) 08.520.231S 1.5 mm thick (teal) 11 DePuy Synthes CMF SYNPOR Porous Polyethylene Implants Surgical Technique

Limited Warranty and Disclaimer: DePuy Synthes CMF products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. WARNING: In the USA, this product has labeling limitations. See package insert for complete information. Rx Only Not all products are currently available in all markets. Manufactured by (United States): DePuy Synthes CMF 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 Legal manufacturer (Canada): DePuy Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 www.depuysynthes.com DePuy Synthes CMF, a division of DOI 2014. All rights reserved. DSUS/MOC/0414/0013 8/14