LOW-NOISE DIESEL-POWERED AC GENERATOR

Similar documents
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Diesel Engine Driven Generators Page 1 of 6

Annex-A TECHNICAL SPECIFICATION

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Magnum Mobile Generator MMG55 Specifications

Technical Specification. Generating Set with Waukesha engine burning natural gas

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Marine Generating Sets 3.7 to 50 kva

DIESEL GENERATOR SETS

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Diesel Generating Set

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Spark-ignited generator set

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

TIG INVERTER INSTRUCTION MANUAL

Power Generation. Power Control PCL System Generator Set Control

C18 ACERT Fire Pump Tier bkw/ rpm

Auxiliary Power Unit (APU) for Military Vehicles

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

Atlas Copco Generators

Air conditioning, electrical testing

Electronic Diesel Control EDC 16

Thyristor-controlled power supplies and battery chargers

understanding medium frequency induction melting furnace and its components

User s Manual Before using the inverter, you need to read and save the safety instructions.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

RM4TG20 three-phase network control relay RM4-T - range V

BB800 Off-Grid Solar System

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Transporter Current Flow Diagram No. 80 / 1

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

Variable Transformers Product Design & Engineering Data

GENERATOR SET, DIESEL ENGINE, MODEL MEP-903A

Specifications for Volkswagen Industrial Engine

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Single-Phase AC Synchronous Generator

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

Commercial Gas Furnace Upflow

Current and voltage measuring relays

Circuit Breakers. NRC Series. NRC Series

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

net flywheel power 74 kw - 99 hp max operating weight kg PAT DOZER BLADE CAPACITY 2.19 m 3

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

Stroom voor elke toepassing

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Buck - Boost Transformers

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

3516 Industrial Engine

Diagnostic Fault Codes For Cummins Engines

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Quick Connect. quick - simple - efficient.

Cross-beam scanning system to detect slim objects. 100 mm in

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

R.C.C.B. s two-pole LEXIC

Generators TEM. for small hydroelectric power stations. Electric Machines

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

TESTING AND COMMISSIONING PROCEDURE FOR EMERGENCY GENERATOR INSTALLATION GOVERNMENT BUILDINGS THE HONG KONG SPECIAL ADMINISTRATIVE REGION

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Bulletin 150 SMC Flex Smart Motor Controller Specifications

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

PM734F - Technical Data Sheet Winding 28

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

SKID STEER LOADER CK20-1 / CK

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

8146/5 Series Breaker Panelboards

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

60 Series - General purpose relays 6-10 A. Features

The CLIPPER Solutions

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Transcription:

DATE: TO: CERTIFIED LOW-NOISE DIESEL-POWERED AC GENERATOR DG450UMI-QD MODEL: (200/400) DG250MI-Q1 SPECIFICATIONS CHAPTER 1: GENERAL CHAPTER 2: EQUIPMENT SPECIFICATIONS ATTACHED DRAWINGS APPEARANCE GENERATOR WIRING ENGINE WIRING SHINDAIWA Corporation 6-2-11, Ozuka-Nishi, Asaminami-Ku, Hiroshima, 731-3167, Japan

Chapter 1 General 1. Standards The designs and the productions are in conformity with: (1) Japan Industrial Standards (2) Electricity Academy Corporation - Electricity Standard Research Association Standard (JEC) (3) Japan Electric Industries Corporation Standard (JEM) (4) Japan Combustion Generating Equipment Corporation (5) Ministry of Construction (Low Noise Type Construction Machinery Standard) (6) Ministry of Construction (Construction Machinery Gas Emission Regulation Standard) 2. Design Conditions (1) Installation Place: Inside/Outside (2) Ambient Temperature: -15-+40 (3) Humidity: Less than 80% (4) Altitude: Less than 300meter (Sea Level) 3. Test and Check The test shall be done for the complete workable unit of Diesel Engine and Portable Generating Unit. (1) Checking Items a) Insulation and Dielectric Tests b) Starting c) Protection Devices Working Test d) Voltage Deviation and Speed Variation: 1/4, 2/4, 3/4 and 4/4 Load e) Load Test: 4/4 Load 30 minutes 4. Painting (1) Painting specifications and color are the manufacturer s standard 1

SPECIFICATION Item AC generator Model DG450UMI-QD Brushless, 3-Phase synchronous AC generator Frequency (Hz) 50/60 (k VA) 37/45 Rated output (kw) 29.6/36.0 Rated voltage (V) 200/220, 400/440 Rated amperage (A) 107/108, 53.5/59 Number of polarity 4 Rated power factor 0.8 (lagging) (V) 100/110 Single Phase output (A) Terminal 75, 38x2 (A) Receptacle 15Ax4 Engine Model ISUZU BB-4JG1T Type 4-cycle,water-cooled,direct injection type Air induction system Exhaust turbocharger Number of cylinder 4 Bore x stroke (mm) 95.4x107 Displacement (L) 3.059 Rated output (kw) 35.4/42.6 Rated revolution speed (min -1 ) 1500/1800 Fuel Diesel fuel (JIS K2204,class 1 to 3) Fuel consumption Note1 (L/hour) 6.6/7.9 Lubricating oil type Class CD or better, SAE30 Lubricating oil capacity (L) 10 (Effective 3) Lubricating oil consumption Note2 (L/hour) 0.018 Coolant capacity (L) 13 Battery 95D31R 5-hour capacity (Ah) 64 Fuel tank capacity (L) 124 Equipment dimension L W H (mm) 1770 920 1350 Mass Dry weight 1130 (kg) Amount weight 1260 Note1, 2: The indicated values were obtained under normal operating condition at 75% load. Use the numerical value as reference. 2

Chapter 2 Equipment Specifications 1. Diesel Engine Model: ISUZU BB-4JG1T Displacement: 3.050 L Rated Output/Rated Speed: 35.4kW {48.10PS}/42.6kW{57.9PS} : 1500/1800min -1 {rpm} Fuel: Diesel Fuel ASTM No. 2 or Equivalent Fuel Filter: Paper Filter Automatic Air Extraction: Standard Accessory External Fuel Changeover: Standard Accessory Battery: 95D31R (12V-64AH) 2. 3-Phase Synchronous Generator 1) Alternator Model: Rotating Field, Self-Ventilation (JCO), Protection (JP20) Output: 37.0/45.0kVA (29.6/36.0kW) Rate: Continuous Voltage: 400/440V Current: 53.4/59.0A Frequency: 50/60Hz Speed: 1500/1800min -1 Pole: 4 Poles Power Factor: 0.8 Lagging Exciting Method: Brushless, AC Exciter Wiring: Star, 3-Phase 4-Wire Insulation: Stator Wiring Class F : Rotor Wiring Class B Standard: JIS, JEM, JEC 2) Characteristic Voltage Deviation: Less than ±1.0% for the nominal value : Transient Values to be less than 20% (100%kVA, Power Factor 0.4) Over-speed Endurance: 2 minutes of120% of the rated speed Wave Distortion: Less than 2% (3-Phase, Line to Line, No Load) Generator Efficiency: More than 85% Insulation Resistance: More than 5MΩ Dielectric Insulation: 1500V for 1 minute or 1800V 1 second 3. Structure 1) Beds (bottom columns) and Vibration Proof Device Alternator is coupled directly with engine and they are installed on the bed through vibration proof device (Rubber Pad and Angle). 2) Low Noise Sound-Proof Enclosure (Bonnet) The structure is that the inside of the bonnet is sound-proof treated and you can lift up the alternator and the engine together with the beds by using a lifting lug. Sound Level: 51/53dB (A)/7m (No Load 1500/1800 min -1 ) 3) Fuel Tank The fuel tank is made of steel and incorporated with the electric type gauge. Capacity: 124L 3

4. Control Devices, Gauges and Protection Devices 1) Control Device Breaker: Circuit Breaker (Rate 600V 125A) : Circuit Breaker (Rate 600V 75A) Exciter Circuit: Automatic Voltage Regulator (F/V Characteristic) Current Leakage Shut Off Device: 30mA 0.1 second 2) Gauges (Displays) AC Volt Meter: 0-600V AC Ampere Meter: 0-75/150A Frequency Meter: 45-65Hz Hour Meter: 9999.9Hr Oil Pressure Gauge Water Temperature Gauge Preheat Lamp Disorder Display Lamps: High Water Temperature, Low Oil Pressure, Insufficient Charging Voltage Adjuster: Adjustable Range; Below 10%- and over +5% Panel Light Emergency Stop Button 3) Protection Device Item Set Value Display Trip Shut-Down Low Oil Pres. 98.1kPa - High Water Temp. 105 - Insufficient Charging - - - Over Current (Thermal relay) 120% - - Current Leakage 30mA 0.1sec. - 4) Output Terminals Plate R, S, T and O output terminals, 4 (four) receptacles of auxiliary power 100/110V 15A x 4 and 2 (tow) 37.5A 1-Phase output terminal set 5. Dimension and Weight Length: 1770mm Width: 920mm Height: 1350mm Dry Weight: 1130kg Outfitted Weight: 1260kg 6. Accessories Grounding Rod: 1 piece Fuse: 10A 1 piece Instruction manual Manual, engine 4

APPEARANCE FRONT VIEW RIGHT SIDE VIEW 5

LEFT SIDE VIEW TOP VIEW 6

CONTROL PANEL NO. Name Description of function 1 3-phase circuit breaker Turns the power supply to load equipment ON (closed) and OFF (open). 2 1-Phase circuit breaker Turns the power supply to load equipment ON (closed) and OFF (open). 3 Voltage meter Indicates voltage. 4 AC ampere meter Indicates phase current. 5 Frequency meter Indicates electricity frequency. 6 Earth leakage relay Detects electric leakage in the 3 phase,4wire output, and turns the circuit breaker OFF when activated 7 Panel light Illuminates control panel surface and Indicates generated electricity when the engine is in operation and generating. 8 Voltage adjustment dial Used to adjust voltage. 9 Volt meter change over switch Used to change the display voltage between phases 10 Warning indicator : NOTE Lights when an equipment malfunction occurs. 11 Coolant temperature gauge Indicates temperature of the engine coolant. 12 Oil pressure. gauge Indicates lubricating oil pressure. 13 Fuel meter Indicates remaining fuel. 14 Hour meter Indicates operating hours of the generator unit. 15 Emergency stop switch When the switch is pressed, stops an engine operation. 7

NO Name Description of function 16 Pre-heat indicator The indicator lights when the key switch is set to the [ON] position, and starts pre-heating. 17 Starter switch OFF: stops engine operation. ON: supplies electricity for control operation, and starts pre-heating. START: starts an engine operation 18 Throttle lever Low idling or rated speed selecting lever. 19 Frequency (Speed) adjusting knob Used to fine adjustment of frequency 20 Frequency select switch Select the rated speed of engine. NOTE High water temp. Low oil press. Charge fault 8

GENERATOR WIREING 9

ENGINE WIRING 10

MENO Product code: 71091-00000 2005.12