Caché Integration with a Network Appliance Filer



Similar documents
Using the Caché SQL Gateway

Caché License Management

Using the Studio Source Control Hooks

Using Encrypted File Systems with Caché 5.0

Identifying Memory Fragmentation within the Microsoft IIS Environment

How To Use Directcontrol With Netapp Filers And Directcontrol Together

Caché Data Integrity Guide

How To Set Up Egnyte For Netapp Sync For Netapp

Try-Catch FAQ. Version February InterSystems Corporation 1 Memorial Drive Cambridge MA

Installing Management Applications on VNX for File

NetApp Storage System Plug-In for Oracle Enterprise Manager 12c Installation and Administration Guide

Caché Security Administration Guide

NTP Software QFS for NAS, NetApp Edition Installation Guide

Clustered Data ONTAP 8.2

Use QNAP NAS for Backup

OnCommand Performance Manager 1.1

NetBackup Backup, Archive, and Restore Getting Started Guide

Networking Best Practices Guide. Version 6.5

StarWind iscsi SAN Configuring HA File Server for SMB NAS

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

Isilon OneFS. Version 7.2. OneFS Migration Tools Guide

Caché Data Integrity Guide

An Oracle White Paper April How to Install the Oracle Solaris 10 Operating System on x86 Systems

Ahsay Replication Server v5.5. Administrator s Guide. Ahsay TM Online Backup - Development Department

StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

Caché Security Administration Guide

Configuring Symantec AntiVirus for NetApp Storage system

v5.2 Installation Guide for Websense Enterprise v5.2 Embedded on Cisco Content Engine

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide

File Auditor for NAS, Net App Edition

Symantec Event Collector 4.3 for Microsoft Windows Quick Reference

Sophos Anti-Virus for NetApp Storage Systems startup guide

Using Windows Administrative Tools on VNX

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

Heroix Longitude Quick Start Guide V7.1

How To Manage File Access On Data Ontap On A Pc Or Mac Or Mac (For A Mac) On A Network (For Mac) With A Network Or Ipad (For An Ipad) On An Ipa (For Pc Or

SAS System for Windows: Integrating with a Network Appliance Filer Mark Hayakawa, Technical Marketing Engineer, Network Appliance, Inc.

EMC Celerra Network Server

Version 3.8. Installation Guide

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

IDENTITIES, ACCESS TOKENS, AND THE ISILON ONEFS USER MAPPING SERVICE

Caché High Availability Guide

Interoperability of Bloombase StoreSafe and Thales e-security keyauthority for Data At- Rest Encryption

Quick Start - NetApp File Archiver

CSP Gateway Configuration Guide

2 Downloading Access Manager 3.1 SP4 IR1

System Manager 1.1. Customer Presentation Feb 2010

Oracle Enterprise Manager

Veeam Task Manager for Hyper-V

HP A-IMC Firewall Manager

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

NETWRIX ACCOUNT LOCKOUT EXAMINER

Symantec NetBackup Backup, Archive, and Restore Getting Started Guide. Release 7.5

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

Oracle Cloud. What s New for Oracle Compute Cloud Service (IaaS) Topics. July What's New for Oracle Compute Cloud Service (IaaS) Release 16.

Veeam Cloud Connect. Version 8.0. Administrator Guide

Infor Web UI Sizing and Deployment for a Thin Client Solution

Installing SQL Server 2012 on SMB Shares on NetApp Storage

LANDesk White Paper. LANDesk Management Suite for Lenovo Secure Managed Client

NetIQ Sentinel Quick Start Guide

Sophos Anti-Virus for NetApp Storage Systems user guide. Product version: 3.0

Avaya Identity Engines Ignition Server Release: Avaya Inc. All Rights Reserved.

Ensemble X12 Development Guide

Caché System Administration Guide

An Oracle Technical White Paper May How to Configure Kaspersky Anti-Virus Software for the Oracle ZFS Storage Appliance

Administration Quick Start

EMC Data Domain Management Center

HP LeftHand SAN Solutions

Enterprise Solution for Remote Desktop Services System Administration Server Management Server Management (Continued)...

Monitoring Nginx Server

Nasuni Management Console Guide

Lepide Software. LepideAuditor for File Server [CONFIGURATION GUIDE] This guide informs How to configure settings for first time usage of the software

Oracle WebLogic Server

Configuring Symantec Protection Engine for Network Attached Storage 7.5 for NetApp Data ONTAP

Novell Identity Manager Resource Kit

StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec

ADOBE CONNECT ENTERPRISE SERVER 6

CSP Gateway Configuration Guide

Introduction to Virtual Datacenter

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

HP IMC Firewall Manager

Novell ZENworks 10 Configuration Management SP3

NexentaConnect for VMware Virtual SAN

Disaster Recovery. Websense Web Security Web Security Gateway. v7.6

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

Dell Recovery Manager for Active Directory 8.6. Quick Start Guide

Quick Start Guide for Parallels Virtuozzo

Isilon OneFS. Version OneFS Migration Tools Guide

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Novell Access Manager

Network Attached Storage. Jinfeng Yang Oct/19/2015

OnCommand Unified Manager 6.3

NTP Software File Auditor for Windows Edition

PN Connect:Enterprise Secure FTP Client Release Notes Version

Backup Solutions for the Celerra File Server

Configuring IBM Cognos Controller 8 to use Single Sign- On

DameWare Server. Administrator Guide

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

Infor Warehouse Mobility for Infor ERP LN Installation Guide

GRAVITYZONE HERE. Deployment Guide VLE Environment

Transcription:

Caché Integration with a Network Appliance Filer Version 2010.2 25 April 2011 InterSystems Corporation 1 Memorial Drive Cambridge MA 02142 www.intersystems.com

Caché Integration with a Network Appliance Filer Caché Version 2010.2 25 April 2011 Copyright 2011 InterSystems Corporation All rights reserved. This book was assembled and formatted in Adobe Page Description Format (PDF) using tools and information from the following sources: Sun Microsystems, RenderX, Inc., Adobe Systems, and the World Wide Web Consortium at www.w3c.org.the primary document development tools were special-purpose XML-processing applications built by InterSystems using Caché and Java. and Caché WEBLINK, Distributed Cache Protocol, M/SQL, M/NET, and M/PACT are registered trademarks of InterSystems Corporation.,, and InterSystems Jalapeño Technology, Enterprise Cache Protocol, ECP, and InterSystems Zen are trademarks of InterSystems Corporation. All other brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. This document contains trade secret and confidential information which is the property of InterSystems Corporation, One Memorial Drive, Cambridge, MA 02142, or its affiliates, and is furnished for the sole purpose of the operation and maintenance of the products of InterSystems Corporation. No part of this publication is to be used for any other purpose, and this publication is not to be reproduced, copied, disclosed, transmitted, stored in a retrieval system or translated into any human or computer language, in any form, by any means, in whole or in part, without the express prior written consent of InterSystems Corporation. The copying, use and disposition of this document and the software programs described herein is prohibited except to the limited extent set forth in the standard software license agreement(s) of InterSystems Corporation covering such programs and related documentation. InterSystems Corporation makes no representations and warranties concerning such software programs other than those set forth in such standard software license agreement(s). In addition, the liability of InterSystems Corporation for any losses or damages relating to or arising out of the use of such software programs is limited in the manner set forth in such standard software license agreement(s). THE FOREGOING IS A GENERAL SUMMARY OF THE RESTRICTIONS AND LIMITATIONS IMPOSED BY INTERSYSTEMS CORPORATION ON THE USE OF, AND LIABILITY ARISING FROM, ITS COMPUTER SOFTWARE. FOR COMPLETE INFORMATION REFERENCE SHOULD BE MADE TO THE STANDARD SOFTWARE LICENSE AGREEMENT(S) OF INTERSYSTEMS CORPORATION, COPIES OF WHICH WILL BE MADE AVAILABLE UPON REQUEST. InterSystems Corporation disclaims responsibility for errors which may appear in this document, and it reserves the right, in its sole discretion and without notice, to make substitutions and modifications in the products and practices described in this document. For Support questions about any InterSystems products, contact: InterSystems Worldwide Customer Support Tel: +1 617 621-0700 Fax: +1 617 374-9391 Email: support@intersystems.com

Table of Contents Caché Integration with a Network Appliance Filer... 1 1 Purpose and Scope... 1 2 Assumptions... 1 3 Integration on Windows... 2 3.1 Infrastructure Requirements... 2 3.2 Configuration Recommendations... 2 4 Integration on UNIX Platforms... 4 4.1 Infrastructure Requirements... 4 4.2 Configuration Recommendations... 5 5 NVRAM Reporting... 6 6 Support... 6 List of Tables Table 1: Recommended NetApp Configuration Options... 3 Caché Integration with a Network Appliance Filer iii

Caché Integration with a Network Appliance Filer This article is an overview of how to use Caché with network-attached storage (NAS) on the Network Appliance filer. It includes the following sections: Purpose and Scope Assumptions Integration on Windows 2000 Integration on UNIX Platforms NVRAM Reporting Support 1 Purpose and Scope Caché, the high-performance object database from InterSystems, has the features professional developers need to quickly create Web and client/server applications. Caché benefits developers by giving them their choice of development tools, programming languages, and methods of data access. Caché benefits transaction processing applications by providing outstanding performance, massive scalability, real-time data analytics, and robust reliability. All these capabilities are tied together in an easy-to-use rapid development environment. Network Appliance, Inc., (NetApp) manufactures high-performance multiprotocol file servers (or filers) and caching appliances for UNIX (NFS), Windows (CIFS), and Web (HTTP) environments. Since OpenVMS works on DECNET and not IP, there is no OpenVMS support. The Network Appliance technical report, Multiprotocol Data Access: NFS, CIFS, and HTTP, describes the NetApp multiprotocol filer architecture and explores the implications of multiprotocol filing for system administrators and end users. This document describes the steps necessary to implement Caché on Windows and UNIX operating systems with database data and log files located on a NetApp filer running Data ONTAP(tm) version 5.3.6x and higher. 2 Assumptions This paper assumes you are familiar with Caché and the operation of NetApp filers. It also assumes you are familiar with the operation of your specific operating system. These configurations were tested using Caché version 5.0, running on Windows 2000 (SP4) and various UNIX platforms listed in the UNIX section. The filer was running Data ONTAP version 5.3.6R2. Within the context of Caché, everything you do with a database on a filer is the same as what you would do to a database stored on a local disk. To create a new database on the filer, create it in the NetApp mount directory. Caché Integration with a Network Appliance Filer 1

Integration on Windows 3 Integration on Windows Integration of a NetApp filer with Caché on Windows has certain infrastructure requirements and configuration recommendations to provide optimal performance and reliability. 3.1 Infrastructure Requirements The following are the infrastructure requirements to integrate Caché with a NetApp filer on Windows. Caché Machine: Caché is running on Windows. Equipment satisfies the system requirements for running Caché. Hardware is on the Windows NT Hardware Compatibility List. Caché and the filer participate in a Windows domain. NetApp Filer: Filer is running Data ONTAP version 5.3.6x or later. Filer is running the CIFS (Common Internet File System) protocol. Network: Network connection exists between the Caché machine and the filer. A Gigabit Ethernet network is recommended to reduce latency and to improve performance. Note: Make sure there are enough disks (HDs), to allow striping, partitioning, and load balancing algorithms to work properly. 3.2 Configuration Recommendations Recommended configuration settings and integration techniques used to implement a successful Caché/NetApp Filer configuration are described in the following sections: Filer Configuration Windows Registry Settings Filer CIFS Share Windows and Caché Configuration For better performance and a more reliable system environment there are several recommended options and configurations. Most of these options are set on both the filer and on the Windows platform. They are described in the following table. 2 Caché Integration with a Network Appliance Filer

Integration on Windows Table 1: Recommended NetApp Configuration Options Option Description On Filer On Windows MaxMpxCt The maximum of outstanding requests the NT client can have against the filer. TCPWindow The maximum transfer size for data across the network. minra Minimal filer read ahead. No no_atime_update Setting this option can improve CPU usage if accurate times are not important. No security The security style is the method the filer uses to determine whether a user has access to a file. CIFS qtree should use ntfs security style. No 3.2.1 Filer Configuration On the NetApp filer, set the following options. CIFS options: options cifs.max_mpx 50 Must match MaxMpxCt (default is 50, other possible values are 126, 253, and 1124). Look at the performance monitor Redirector-Current Commands statistic. If this is constantly running at the current value, increase the value. options cifs.tcp_window_size 64240 Set this value to 64240 (0xFAF0). These are recommended settings. See the na_options manual page for more information. General options: vol options minra on When this option is on, the filer performs minimal read-ahead on the volume. By default, this option is off, causing the filer to perform very aggressive read-ahead on the volume. vol options no_atime_update on When this option is on, it prevents the update of the access time on an inode when a file is read. This option is useful for volumes with extremely high read traffic, since it prevents writes to the inode file for the volume from contending with reads from other files. Use this option when you know in advance that the correct access time for inodes is not needed for files on that volume. Qtrees: These are recommended settings. See the na_vol manual page for more information. qtree security qtreename ntfs The qtree security command changes the security style for files and directories. When using the ntfs security style for CIFS requests, Windows NT permissions determine user access. This is the recommended setting. See the na_qtree manual page for more information. 3.2.2 Windows Registry Settings On Windows, InterSystems recommends you make the following modifications: Increase TCP Windows sizes to 64KB. Increase MaxMpxCt; must match cifs.max_mpx value. Increase negotiated CIFS buffer sizing. Caché Integration with a Network Appliance Filer 3

Integration on UNIX Platforms Set the following registry keys by running REGEDT32.EXE. Go to the HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services key and make the described entries: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services LanmanServer\parameters\MaxMpxCt Datatype: DWORD Value: To match the setting above for cifs.max_mpx HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services Tcpip\Parameters\TcpWindowSize Datatype: DWORD Value: 64240 (0xFAF0) ----> Global setting for all interfaces <--- HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services \Tcpip\Parameters\Interfaces\interface\TcpWindowSize Datatype: DWORD Value: 64240 (0xFAF0) Adapter Setting: ---> setting per interface <--- 3.2.3 Filer CIFS Share Create a share on the filer with security set to Everyone Full Control. For information about how to create a share on a filer, consult the Data ONTAP Software Systems Administration guide that accompanied your system. 3.2.4 Windows and Caché Configuration The following configuration procedures ensure a proper setup of Caché with a NetApp filer: NetApp is properly joined to the Windows domain. Users authenticate against a Windows domain server to access shares on the filer. The NetApp directory is mounted (use the Map Network Drive command from the Tools menu of Windows Explorer) with the same username and password as your Windows login. Note: A useful test to check if the connection is configured correctly is to remotely telnet to Caché and open a file on the drive mapped to NetApp. For example, input Open "F:\B.TXT":"NWS", where F: is your mapped drive and B.TXT is an arbitrary file. If you return to the Caché prompt, the connection is configured properly; if the session hangs indefinitely, it is not. 4 Integration on UNIX Platforms Integration of a NetApp filer with Caché on UNIX platforms has certain infrastructure requirements and configuration recommendations to provide optimal performance and reliability. 4.1 Infrastructure Requirements The following are the infrastructure requirements to integrate Caché with a NetApp filer on UNIX platforms: Caché Machine: Equipment satisfies the system requirements for running Caché. Caché is running on a supported UNIX platform. See the Supported Server Platforms section of the Supported Platforms guide. etapp Filer: 4 Caché Integration with a Network Appliance Filer

Integration on UNIX Platforms Filer is running Data ONTAP version 5.3.6x or later. Filer is running the NFS (Network File System) protocol. NFS share is exported and mounted writable by the client. Network: Network connection exists between the Caché machine and the filer. A Gigabit Ethernet network is recommended to reduce latency and to improve performance. TCP Protocol: Note: Make sure there are enough disks (HDs), to allow striping, partitioning, and load balancing algorithms to work properly. 4.2 Configuration Recommendations Recommended configuration settings and integration techniques used to implement a successful Caché/NetApp Filer configuration on UNIX platforms are described in this section. Mount options: For all mounts: NFS Version 3, hard, intr, Readsize= 32768, Writesize= 32768, nolock Detailed syntax depends on operating system. Example options for Linux: rsize=32768, wsize=32768, intr, rw, nolock, nfsvers=3, suid, hard, rw Example options for Solaris: rsize=32768, wsize=32768, intr, rw, vers=3, suid, hard Security style: Security style is the method the filer uses to determine whether a user has access to a file. Use the unix security style for the NFS qtree. When the unix security style is used, the user s UID and GID, and the UNIX -style permission bits of the file or directory determine user access. This is the recommended setting. See the na_qtree manual page for more information. The following example sets the security style of the root volume: qtree security / unix Linux Export Entries On NFS-mounted file systems on Linux, a file created by an SUID:SGID executable has different, non-unix standard, owners than on standard file systems. The SGID bit on the executable fails to take effect, while the SUID bit succeeds in setting the owner of the file to the owner of the executable. The solution is to give root access to all hosts in the etc/exports file. For example: /vol/vol1/scratch00 -root=host1:host2:host3,sec=sys See the na_exports manual page for more information. The preceding options are recommended for high-speed connections. Contact Network Appliance for a list of recommended kernel patches for your operating system. Caché Integration with a Network Appliance Filer 5

NVRAM Reporting 5 NVRAM Reporting Network Appliance recommends enabling the feature of Data ONTAP (NetApp s operating system software) which supports special error processing when connected to a database server. To do this, enter the following command from the filer s console or a telnet session: vol options vol0 nvfail on This causes the filer to issue appropriate error messages in the \\FILER1\C$\etc\messages file in the case of system failure that might affect the Caché database. The administrator learns of these errors either by examining the message logs or by the auto-support email notification feature of the filer. In particular, this option enables some additional status checking when the filer goes through its initialization sequence at boot time to verify that the NVRAM (non-volatile random access memory) is in a valid state. This is the case for both a clean (normal) shutdown or a dirty (crash, power failure, etc.) outage. Only a failure of the NVRAM card itself should cause it to become invalid. If the contents of NVRAM are found to be invalid, an error message is sent to the system console and to the filer log file. At that point, the Caché system administrator ensures that the state of the database is correct and valid. Competitive database products may recommend using the optional rename feature. However, to ensure the proper functioning of Caché and the handling of its database, journal, and log files, InterSystems recommends using the Caché built-in Freeze on Error feature instead. From the [Home] > [Configuration] > [Journal Settings] page of the System Management Portal, click in the Freeze on error box and click Save to update the setting. 6 Support InterSystems and Network Appliance support the specific configurations described in this document. If you experience any problems implementing the techniques described in this technical paper, please contact the InterSystems Worldwide Response Center (WRC) (WRC) or a Network Appliance Technical Marketing Engineer. 6 Caché Integration with a Network Appliance Filer