TABLE OF CONTENTS IMPORTANT SAFEGUARDS...1 MAIN PARTS 2 OPERATION.3 CLEANING AND MAINTENANCE.. 5 TROUBLE-SHOOTING. 11

Similar documents
HAIR CLIPPER. Model No. HC5150 HC

EBK 340 / EBK 341 Electric Power Nozzle

Wessel-Werk EBK 340. Electric Power Nozzle. Operating Manual Wessel-Werk GmbH Im Bruch 2 D Reichshof Germany

VACUUM CLEANER INSTRUCTION MANUAL

Digital Photo Picture Frame. Operation Manual

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Wessel-Werk EBK 360. Electric Power Nozzle. Operating Manual Wessel-Werk GmbH Im Bruch 2 D Reichshof Germany

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Coway Air Purifier AP-1008DH

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Safety, Operation and Maintenance Manual with Parts List

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Record Cleaning Machine

All technical modifications reserved. 09/08. TSC

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

HYLA NST Cleaning System

National- Spencer Inc.

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

- 2 - IMPORTANT SAFETY REMINDERS

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

UPGRADING AND SERVICING GUIDE

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Front Panel Board Cable Replacement Instructions

MAINTENANCE & TROUBLESHOOTING

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Manual Ranging MultiMeter

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

OWNER S MANUAL Table Tennis Table Patent Pending

U S E R S G U I D E READ ALL INSTRUCTIONS BEFORE USING STEAM CLEANER USE ONLY AS DIRECTED. WARNING: Danger of Scalding!

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Instruction manual for Firstline FCS12000CH

15GAL STEEL OIL DRAIN WITH 110V PUMP

SERVICE GUIDE. Gateway Notebook

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Hair Clipper. Hair Clipper HC365 HC365. Model No. HC365

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

#12 Professional Meat Grinders

Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

MAINTENANCE & TROUBLESHOOTING

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Dehumidifier Users manual. For Models: DH45S DH65S

Electric Water Kettle

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

The Storm 20-Gallon Wet/Dry Vac

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Bagless Upright. vax.co.uk. What s your Vax model number?

Heated throw User manual

MINI ELECTRIC SEWING MACHINE OPERATION MANUAL

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Use and Care Manual. Model CPA12KH AIR CONDITIONER

2-SLICE COOL TOUCH TOASTER

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Replacing the Gateway M320 Keyboard

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

tire inflator with pressure gauge

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

Self-Cleaning Litter Box

Instruction Manual. AWK-115S

Instructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS. Customer Service

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Master Prep Professional

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Service Guide. Gateway M275

DIMENSION ELECTRIC RANGE

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Mini multi-purpose sewing machine

Mini-led spotlight with magnetic base

EasyNote TJ Series. Disassembly Manual

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Instructions. UV UltraVac_IM_B.indd 1 28/09/ :23

Ultrasonic Jewelry Cleaner. SI414 Instructions CONTAINS IMPORTANT SAFETY INFORMATION READ AND SAVE THESE INSTRUCTIONS MAX FILL MIN FILL

Carpet Shampooer 500w

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

PA 03 basic device TECHNICAL DATA. English

24 Wide Screen LED Monitor with HDMI

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

AutoRanging Digital MultiMeter

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Garage Pro USER S GUIDE 18P0 SERIES. 3 Safety Instructions. Product View. Assembly 5-6. Operation 6-9. Maintenance and Care

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Processor Cage Fans, Front and Rear Replacement Instructions

Inspiron 15. Service Manual Series

SpotBot. 3 Safety Instructions. 4-5 Product View. 6-7 Special features Operation. 11 Maintenance and Care Troubleshooting

PROFESSIONAL POPCORN MAKER

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Wall-Mounting your HP computer. User Guide

Transcription:

TABLE OF CONTENTS IMPORTANT SAFEGUARDS.......1 MAIN PARTS 2 OPERATION.3 PRE-OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS CLEANING AND MAINTENANCE.. 5 CLEANING PRE-FILTER..5 CLEANING HEPA FILTER 6 REMOVING/INSTALLING UV LAMP..8 CLEANING AND MAINTENANCE..11 TROUBLE-SHOOTING. 11

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE. WARNING: RISK OF ELECTRICAL SHOCK Safety precautions should always be used when operating this or any electrical appliance. Decrease the risk of electrocution, electric shock, injury or fire by reading and following all of the warnings below. To reduce the risk of electric shock, do not attempt to service the air purifier in any way other than to replace or clean the air filter. Read all instructions before operating the air purifier. This product operates at 220-240V, 50/ 60Hz. Do not run the power cord under carpets, and do not cover with throw rugs, blankets or towels. This product is not intended to filter oil or grease from air. Always unplug the power cord from the electrical outlet when the air purifier is not in use or when changing the filter. Never run the air purifier unless it is fully assembled. Do not alter the plug in any way. Always turn off the air purifier before unplugging the air purifier from outlet. Do not place the cord near a heated surface. Never operate the air purifier if the plug or cord is damaged or appears damaged. Only qualified service personnel should ever replace or attempt to replace a damaged power cord. Never use the power cord to pick up, carry, drag, pull, or lift the air purifier. Do not pull the cord against or around sharp corners and edges. Always remove the plug from its power outlet by holding onto the plug itself and pulling gently. Never pull on the cord itself to unplug it from its power outlet. Use care when operating the air purifier by keeping all foreign objects, fingers, body parts, hair, loose clothing and jewelry away from openings. Never touch the air purifier or its plug when your hands are wet. - 1 -

Note: Before operating the air purifier, make sure the air filters inside the air purifier are not wrapped in plastic. When the air purifier is plugged in you should hear a beep. Press the Power button to turn it on. If the air purifier does not power on, ensure the front cover is installed correctly. Save these instructions! MAIN PARTS - 2 -

4. Pressing Fan Speed Button ( ) at this point will set the air purifier into Medium fan speed ( 2). 5. Pressing Fan Speed Button ( ) again will set the air purifier into Low fan speed ( 1). 6. Pressing Fan Speed Button ( ) once more will set the air purifier back to High fan speed ( 3). 7. To turn the air purifier off, press the On/Off Button ( ). NEGATIVE ION FUNCTION: To turn the air purifier on, press the On/Off Button( ),the ionizer also works,during the air purifier working time,the ionizer is always working. UV LAMP FUNCTION The UV-C germicidal lamp : can kill harmful airborne bacteria and virus. This function will work in any mode. Press the UV Button ( ) to start the UV lamp and stop the UV lamp by pressing the UV Button ( ) again. UV LAMP RESET FUNCTION: If the UV lamp needs to be replaced, the UV icon on the LCD will illuminate and flicker. After replacing the UV lamp, reset the UV lamp by pressing the UV Button ( ) for a few seconds, the UV icon will stop flickering and the new UV lamp will start to work. Check from the UV view window (Unit Front View in page 2), if the UV lamp still lights, it should not be replaced. HEPA RESET FUNCTION: If the HEPA filter needs to be cleaned, HEPA Reset icon on LCD will illuminate and flicker. After cleaning the HEPA filter, RESET the HEPA filter by using a pin or needle to press the HEPA RESET Button ( ), then the icon will stop flickering. For instructions on how to clean the HEPA filter see the CLEANING HEPA FILTER on page 6. - 4 -

CLEANING AND MAINTENANCE CLEANING PRE-FILTER (See Air Cleaning System) 1. Turn off and unplug the unit; 2. Press the Lock & Release Button and remove the Rear Cover from the unit; NOTE: The unit will shut off after the rear cover is removed. - 5 -

3. Remove the pre-filter from the rear cover. Clean the pre-filter with the vacuum brush attachment of your vacuum cleaner. This will remove lint and dirt from the filter. Use a clean, damp, soft cloth to wipe the pre-filter again. NOTE: Clean the pre-filter often if possible. 4. After cleaning, reattach the pre-filter to the rear cover, and install the rear cover back to unit and securely latch in place. CLEANING HEPA FILTER (See Air Cleaning System) 1. Turn off and unplug the unit; 2. Press the Lock & Release Button and remove the Rear Cover from the unit; NOTE: The unit will shut off after the rear cover is removed. - 6 -

3. Remove the HEPA filter. 4. Use the brush attachment with your vacuum cleaner to clean the filter. CAUTION: Do not use water or any household cleaner to clean the HEPA filer. NOTE: The HEPA filter can be used continuously for up to two years. When the HEPA filter turns from white to black, it should be replaced with a new one. If the HEPA filter is still white, it does NOT need to be replaced. - 7 -

5. Depending upon your filter type, either it will only fit in one way or reference the arrow on the side of the filter. Install the rear cover back to unit and securely latch in place. NOTE: Both of filter and rear cover must be installed otherwise the purifier will not power on. REMOVING/INSTALLING UV LAMP (See Air Cleaning System) 1. Turn off and unplug the unit. 2. Press the Lock & Release Button and remove the Rear Cover from the unit. NOTE: The unit will shut off after the rear cover is removed. - 8 -

3. Remove the HEPA filter. 4. Use a screwdriver to remove the two screws and detach the UV lamp cover. - 9 -

5. Grasp the UV lamp and pull it straight out from the lamp socket. The lamp is made of quartz so it is stronger than a standard UV lamp, however we recommend reaching in toward the base since it is easier to remove from here than pulling on the end of the lamp. If you have rubber gloves or something similar that has a non-slip grip that is preferable. You should minimize the contact time with your fingers on the glass. CAUTION: The UV lamp is a glass product, please handle it carefully. Please reference www.kogan.com for more information in regards to the safest way to replace the UV lamp. 6. Take a new UV lamp and insert it into the lamp socket. Simply press in on the end of the glass lamp to lock into place. Re-install the UV lamp cover (the large metal face should be above the uv lamp and align the two screw holes with the back of the air purifier), then re-install the filter and rear cover. - 10 -

CLEANING AND MAINTENANCE 1. The air purifier should be checked at least once every month. More frequent cleaning may be required depending upon environmental conditions. 2. Clean the HEPA filter and pre-filter with the vacuum brush attachment of your vacuum cleaner. This will remove lint and dirt. See CLEANING PRE-FILTER and CLEANING HEPA FILTER on page 5 to 6. 3. Check the UV lamp from the UV view window (Unit Front View in page 2). If the UV lamp needs to be replaced, see REMOVING/INSTALLING UV LAMP on page 8. 4. Use a clean, dry, soft cloth to wipe the external surface of unit. NOTE: Do not stick any foreign objects or your fingers inside the unit. CAUTION: Do not use any chemical or harsh cleaners, etc., as they will damage the product. NEVER use ALCOHOL OR SOLVENTS. TROUBLE SHOOTING TIPS If the air purifier shuts off unexpectedly, safety features may have been activated to prevent damage or injury. If this happens: 1. Be sure the air purifier is plugged into a working electrical outlet; 2. Check to be sure the UV lamp and UV lamp cover are firmly seated in place; 3. Check to be sure the HEPA filter is firmly seated in place; 4. Check to be sure the rear cover is latched firmly in place. NOTE: IF YOU CONTINUE TO EXPERIENCE A PROBLEM, PLEASE CONTACT THE THE KOGAN CUSTOMER SUPPORT TEAM IN REGARDS TO THE WARRANTY. DO NOT ATTEMPT TO TAKE APART THE UNIT BY YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY. - 11 -