CM80 and CM120 Valves Build Program Model CM80 80 l/min (21.1 gpm) Model CM120 120 l/min (32.7 gpm) 290 bar (4200 psi)
CM80 and CM120 Valve Build Program The CM80/CM120 Build Program leverages the versatile and modular product design of the CM80/CM120 valve; enabling a stocking distributor to add further value for end customers in the following ways: First to deliver a custom valve solution for a customer requirement Quick response to dynamic customer needs and modifications Product Overview The Eaton CM80 and CM120 valves offer a modular sectional design that offers absolute flexibility for a broad range of mobile applications. The product combines proven modular design features with the ability to utilize Eaton s Screw-In Cartridge Valve (SICV) technology to provide a wide choice of configuration options. The CM80/ CM120 valves are an open center, parallel circuit architecture, and available in configurations with up to 10 operating sections. Versatile and Modular Work ports and inlet options accept Vickers SiCV cartridges. Sections can use either of the available actuation methods; manual or hydraulic. Symmetrical valve bodies allows for the actuation in either direction to meet various mounting requirements. Rated Flow Rates: CM80: to 80 I/min (21.1 USgpm) CM120: to 120 I/min (32.7 USgpm) Rated Fatigue Pressure per NFPA T2.6.1: 250 bar (3,625 psi) Inlet Qualified at 1 million cycles at 290 bar (4,200 psi) test pressure 250 bar (3625 psi) Work Ports Qualified at 1 million cycles at 290 bar (4,200 psi) test pressure 25 bar (362 psi) Tank Actuation Options Manual or Hydraulic Pilot 2 eaton CM80 and CM120 Valves Build Program E-VLMB-MC007-E March 2010
Assembly CM80/120 CM80 41.2~43.1 N-m. CM120 74.5~76.5 N-m. Inlet Cover O-ring Section Assembly (Max. 10 Section Assemblies Can b e Fitted in Between Inlet Cover and End Cover or Outlet) Screw-in Cartridge or Plug Tighten Torque 68~75 N-m. End Cover or Outlet Cover Note: View indicates LH build. Valve bodies are symmetrical; therefore spools can be oriented in opposite direction. Kit Components CM80 41.2~43.1 N-m. CM120 74.5~76.5 N-m. CM80 Operating Sections 201AP00012A 201AP00015A 201AP00016A 201AP00017A 201AP00018A 201AP00025A CM80 Inlet Module 9900640-000 Top ported, SAE-12 ports with section seal and CM80 Endcover Kit plugged WP cavities, 3P4W motor spool plugged WP cavities, 3P4W cylinder spool plugged WP cavities, 4P4W detented float spool Hydraulic pilot, parallel circuit, SAE-10 ports, plugged WP cavities, 3P4W cylinder spool Hydraulic pilot, parallel circuit, SAE-10 ports, plugged WP cavities, 3P4W cylinder spool Manual, RH build, parallel circuit, SAE-10 ports, plugged WP relief cavities, 3 position detent, motor spool 9900641-000 Top ported, SAE-12 tank port and PBY end port with CM80 Handle Kit 9900637-001 Standard Handle Kit - Includes handle CM80 Tie-bolt Kits 9900636-001 CM80 - One Section Kit 9900636-002 CM80 - Two Section Kit 9900636-003 CM80 - Three Section Kit 9900636-004 CM80 - Four Section Kit 9900636-005 CM80 - Five Section Kit 9900636-006 CM80 - Six Section Kit 9900636-007 CM80 - Seven Section Kit 9900636-008 CM80 - Eight Section Kit 9900636-009 CM80 - Nine Section Kit 9900636-010 CM80 - Ten Section Kit CM80 Accessories 6023133-001 Detent Kit 5993362-001 PBY Sleeve Assembly 9900725-000 Service Seal Kit, includes spool seals, load drop check seals, and section seal for one section eaton CM80 and CM120 Valves Build Program E-VLMB-MC007-E March 2010 3
Exploded View CM80/120 14.7±1.5 N-m 14.7±1.5 N-m Screw-in Cartridge or Plug, Torque 68~75 N-m. Tightening Torque 10.8±1.0 N-m Screw-in Cartridge or Plug Torque 68~75 N-m. 10.8±1.0 N-m Apply Loctite #262 on Threads 24.5±3.0 N-m Note: View indicates LH build. Valve bodies are symmetrical; therefore spools can be oriented in opposite direction. Kit Components CM120 Operating Sections 202AP00001A 202AP00002A 202AP00003A 202AP00004A 202AP00005A 202AP00028A CM120 Inlet Module plugged WP relief cavities, 3P4W cylinder spool plugged WP relief cavities, 4P4W detented float spool Hydraulic pilot, RH build, parallel circuit, SAE-12 ports, plugged WP relief cavities, 3P4W cylinder spool plugged WP relief cavities, 3P4W motor spool Hydraulic pilot, parallel circuit, SAE-12 ports, plugged WP relief cavities, 3P4W motor spool Manual, RH build, parallel circuit, SAE-12 ports, plugged WP relief cavities, 3 position detent, motor spool 6022670-001 Top ported, SAE-16 ports with section seal and CM120 Handle Kit 6022674-001 Standard Handle Kit - Includes handle CM120 Tie-bolt Kits 6022678-001 CM120 - One Section Kit 6022678-002 CM120 - Two Section Kit 6022678-003 CM120 - Three Section Kit 6022678-004 CM120 - Four Section Kit 6022678-005 CM120 - Five Section Kit 6022678-006 CM120 - Six Section Kit 6022678-007 CM120 - Seven Section Kit 6022678-008 CM120 - Eight Section Kit 6022678-009 CM120 - Nine Section Kit 6022678-010 CM120 - Ten Section Kit CM120 Accessories CM120 Endcover Kit 6025419-001 Top ported, SAE-16 tank port and PBY end port with 9900679-000 Detent Kit 5993364-001 PBY Sleeve Assembly 9900726-000 Service Seal Kit, includes spool seals, load drop check seals, and section seal for one section 4 eaton CM80 and CM120 Valves Build Program E-VLMB-MC007-E March 2010
Eaton Hydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Hydraulics Group Asia Pacific Eaton Building 4th Floor, No. 3 Lane 280 Linhong Rd. Changning District Shanghai 200335 China Tel: (+86 21) 5200 0099 Fax: (+86 21) 5200 0400 2010 Eaton Corporation All Rights Reserved Printed in USA Document No. E-VLMB-MC007-E March 2010