SyncLink USB Serial Adapter

Similar documents
SyncLink GT2/GT4 Serial Adapter

USB to serial chip CH340

Advanced Data Capture and Control Systems

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Application Note 83 Fundamentals of RS 232 Serial Communications

USB TO SERIAL ADAPTER

Manual Serial PCI Cards

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

PCMCIA 1 Port RS EDITION OCTOBER 1999

Cable Pinouts. SRP I/O Module

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

1 Port FTDI USB to RS232 Null Modem Adapter

2-Port RS232/422/485 Combo Serial PCI Card

Cable Specifications and Information

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

DOSISYS. Hands Free Reader LDM LDM 220. User Manual A

RS-232 COMMUNICATIONS

Cabling Guide for Console and AUX Ports

1-Port R422/485 Serial PCIe Card

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

CP2110-EK CP2110 EVALUATION KIT USER S GUIDE. 1. Kit Contents. 2. Relevant Documentation. 3. Software Setup

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

PCS0100en Persy Control Services B.V. Netherlands

Future Technology Devices International Ltd. USB NMC-2.5m. USB to USB Null Modem Cable. Datasheet

Objectives. Basics of Serial Communication. Simplex vs Duplex. CMPE328 Microprocessors (Spring ) Serial Interfacing. By Dr.

VSCOM USB PRO Series Industrial I/O Adapters

Future Technology Devices International Ltd

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

Professional USB to Serial Adapter Hub with COM Retention

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854

Cable Specifications

2/4/8 Port USB to Serial Adapter Hub with COM Retention

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

LOW COST GSM MODEM. Description. Part Number

isco Connecting Routers Back to Back Through the AUX P

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

WHQL Certification Approval...2 User Interface K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5

FT2232H Mini Module. USB Hi-Speed FT2232H Evaluation Module. Datasheet

C232HD. USB 2.0 Hi-Speed to UART Cable. Datasheet

FT4232H Mini Module. USB Hi-Speed FT4232H Evaluation Module. Datasheet

Connecting Serial Interface Cards to a Network

Serial to Bluetooth Adapter

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Serial Communications

TTL-232R-3V3 USB to TTL Serial Converter Cable

XPort Universal Demo Board User Guide

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

User Manual IC-485AI

Industrial Multi-port Serial Cards

How to setup a serial Bluetooth adapter Master Guide

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

The following is a summary of the key features of the ARM Injector:

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Siemens DECT Engine MD32. Product Description. Information and Communication Products

2-port RS-232 High Speed Low Profile Universal PCI Serial Board

RS - SPM. Serial parallel translator module

Bluetooth UART/RS232 Module

Making a DB to RJ45 adapter.

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Pmod peripheral modules are powered by the host via the interface s power and ground pins.

How To Use An Adh8012 Gsm Gprs Module With A Gsm (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs

HARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC Lark Ave., Suite 200 Los Gatos, CA

Connector and Cable Specifications

Revision Date: September 19, 2006

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

FarSync T2Ue. A 2 port PCI Express synchronous communications adapter

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Modbus Communications for PanelView Terminals

Cable Specifications. T3 Trunk Cabling APPENDIX

2-port RS-422 / 485 Universal PCI

How To Use A Sunix Ser5037A Card On A Pc Or Mac Or Mac With A Microsoft Powerbook (Powerbook) With A Powercard (Powercard) And Powercard With A Mini Usb (Powerboard) With An

2 Port Industrial PCIe RS232 Serial Card with Power Output and ESD Protection

USB-Blaster Download Cable User Guide

RS232 Data Interface a Tutorial on Data Interface and cables

RS-232 Cables, Wiring and Pinouts. Brief tutorial and pinouts for RS-232, T1/E1 and V.35. Contents

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

DECT Module UM-9802 Datasheet

Moxa TCC-100/100I User s Guide

8 by 8 dot matrix LED displays with Cascadable Serial driver B32CDM8 B48CDM8 B64CDM8 General Description

Comtrol Cable User Guide

Quectel Cellular Engine

4 Port PCI Express RS232 Serial Card with Power Output and 15kV ESD Protection

F2400 FOM II Series Fiber Optic Modem Technical Manual

User s Manual of Board Microcontroller ET-MEGA2560-ADK ET-MEGA2560-ADK

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

Using Xbee in Serial Communication

FOM-5A, 6A. Asynchronous Fiber Optic Modem

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

TTL-232R. TTL to USB Serial Converter Range of Cables. Datasheet

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

Omron I/O Driver (Series 2) Programmable Serial Interface Card

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Transcription:

SyncLink USB Serial Adapter Hardware User s Manual MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2012-2013 MicroGate Systems, Ltd. All Rights Reserved

Contents Overview... 3 Features... 3 Specifications... 3 LED Indicators... 4 Troubleshooting... 4 All LEDs Off... 4 Red LED Only... 4 Yellow LED Only... 4 Green LED On... 5 Signal Specifications... 5 Single Ended Signals (RS-232/V.28)... 5 Differential Signals (RS-422/RS-485/V.11)... 5 Clock Polarity... 5 Serial Interface Selection... 6 Differential Input Termination... 6 Serial Connector Pin Assignments... 7 RS-232... 7 V.35... 8 RS-422/RS-449/RS-485/RS-530... 9 RS-530A... 11 X.21... 12 General Purpose I/O Signals... 13 DC GPIO Specifications... 13

Frequency Synthesizer... 15 Overview The SyncLink USB Serial Adapter is an external device that connects a host computer USB port to a synchronous serial port. The adapter provides a single serial port for use by the system. Multiple SyncLink USB adapters may be attached to the same computer or powered USB hub. A variety of serial protocols and interface standards are supported. Refer to the software documentation included with the adapter for details on using the card for a specific application. Before connecting the SyncLink USB to your system, preinstall drivers as described in the README provided on the software disc or the software package downloaded from the MicroGate website. The SyncLink USB serial adapter should be plugged into a USB 2.0 or later Hi-speed (480Mbps) USB port. Operating on a slower USB port will not allow you to take full advantage of the adapter s capabilities. Install directly into a host USB port for best results. SyncLink USB requires 500mA of power from the USB port, which is standard and supported by most USB ports. Some unpowered/passive hubs or small mobile devices may not provide a full 500mA. Check the documentation provided with your external hub or mobile device if you are unsure of the specifications or experiencing any difficulties. Features Maximum Speeds: 10Mbps synchronous, 8Mbps asynchronous SDLC, HDLC, BISYNC, ISOCHRONOUS, MONOSYNC, ASYNC, raw bit-synchronous protocols Selectable hardware CRC: CRC-16, CRC-32, None DPLL Clock Recovery (x8 and x16 sampling) Clock Generation Configurable transmit preamble and idle patterns Encoding: NRZ,NRZB,NRZ-L,NRZI,NRZ-M,NRZ-S,FM0,FM1,Manchester,differential biphase level Selectable interface for RS-232, V.35, RS-422/485, RS-530, RS-530A, RS-449, X.21 Full set of control and status signals (DTR,DSR,RTS,CTS,DCD,RI,LL,RL) Specifications MicroGate FPGA serial controller (one port) USB 2.0 hi-speed (480Mbps), compatible with USB 2.0 and USB 3.0 ports Operating Temperature: -40C to +85C Storage Temperature: -55C to +125C Environmental: humidity 0 to 95% non-condensing; alt. - 200 to +10,000 ft Mechanical: 3.6 length, 2.6 width, 1.9 height Power usage: Bus Powered, 5V, 500mA max (300mA typ) Regulatory: FCC Class A, CE, ANSI C63.4, EN55022 Class A, EN55024, RoHS Connector: DB-25 (male)

Cable Options: DB-25 (female) to DB-25 (male); DB-25 (female) to 34-pin V.35 (male); DB-25 (female) to 37-pin RS-449 (male); DB-25 (female) to 15-pin X.21 (male) LED Indicators LEDs near the USB port provide information about SyncLink USB operation: Red Only Device plugged in and powered. Yellow Only Device software loaded, DB-25 interface is disabled. Green On Device is ready for use. Red = Transmit Data, Yellow = Receive Data Troubleshooting Try these steps if the SyncLink USB is plugged into a USB port and not functioning as expected: All LEDs Off Verify host system or USB hub is turned on and powered. Try a different USB cable, or reseat cable. Plug SyncLink USB in a different USB port. Plug SyncLink USB in a different host or hub. If the above steps fail, the SyncLink USB may have a hardware failure. Red LED Only Verify device software (driver) is installed and loaded. Verify device software is latest version. Verify device is not disabled in software (such as in Windows Device Manager). If the above steps fail, the SyncLink USB may have a hardware failure. Yellow LED Only Follow the steps appropriate for your operating system to enable the DB-25 serial interface. In Windows, this is done from the Advanced tab of the Properties page of the device in the Device Manager. You must select the serial interface standard required for your application (RS232, V.35, RS530, etc).

Green LED On Monitor the red LED (transmit) and yellow LED (receive) for indications of data transfer. These are only valid when the green LED is on. If you see no data, verify cabling, serial interface selection (RS232, V.35, RS530, etc), serial protocol settings and remote device status. Signal Specifications Each serial signal (control, status, data, or clock) is compatible with an electrical specification that is selected through software settings. This section briefly describes the specifications supported by the card. Single Ended Signals (RS-232/V.28) Single ended signals supported by the card are compatible with both RS-232 and ITU V.28 standards. Each single ended signal uses one conductor in a cable, and all single ended signals share a common ground conductor. Maximum Voltage Range: +15 to -15V (between signal and ground) +3V to +15V (+5V typical) = control/status signal on or data value of 0-3V to -15V (-5V typical) = control/status signal off or data value of 1 Voltage between -3V to +3V = invalid (indeterminate) state Max cable length 50 feet Max data rate 20kbps The maximum data rate of 20kbps is part of the RS-232/V.28 standards. The SyncLink card can operate at speeds up to 120kbps depending on the cable length and loading. Longer cables and increased loading reduces the maximum supported data rate. Differential Signals (RS-422/RS-485/V.11) Differential signals supported by the card are compatible with RS-422, RS-485 and ITU V.11 standards. Each differential signal uses two conductors in a cable (signal pair). A common ground conductor is recommended for use with differential signals to reduce common mode voltages between cable ends which may result in incorrect or impaired operation. Maximum Voltage Range: +5 to -5V (between conductors in a pair) +200mV to +5V (+2V typical) = control/status signal on or data value of 0-200mV to -5V (-2V typical) = control/status signal off or data value of 1 Voltage between -200mV to +200mV invalid (indeterminate) state Max cable length 4000 feet Max data rate 10Mbps Longer cables and increased loading reduces the maximum supported data rate. Clock Polarity Synchronous serial communications (HDLC/Bisync/Monosync) may use separate clock signals to control the timing of data signals. One clock cycle equals one bit. There are two clock edges (rising and falling)

for each clock cycle. On one edge, the transmit data output changes. On the other edge, the receive data input is sampled. The assignment of clock edges to transmit data transition and receive data sampling is referred to as clock polarity. The SyncLink USB uses the clock polarity in the RS-232/RS-422/V.24/V.28/V.11 standards as described below: RS-232/V.28 Single Ended Signals +3V to +15V (+5V typical) = clock on -3V to -15V (-5V typical) = clock off On to Off edge (falling edge) = receive data sample (bit center) Off to On edge (rising edge) = transmit data transition (bit edge) RS-422/RS-485/V.11 Differential Signals +200mV to +5V (+2V typical) = clock on -200mV to -5V (-2V typical) = clock off On to Off edge (falling edge) = receive data sample (bit center) Off to On edge (rising edge) = transmit data transition (bit edge) Most serial communications equipment uses the above clock polarity, but some non-standard equipment may use the opposite polarity. For differential signals, inverting the conductors of each clock signal pair will alter the polarity. Serial Interface Selection The serial adapter supports different interface types, which are selected by software configuration. By default on power up, the interface is disabled and does not drive any outputs. The method of changing the interface type depends on the operating system and application. For example, Windows implements this setting in the device properties of the device manager and Linux implements the setting with an ioctl() call. Refer to the software documentation for details. Some interface types require a conversion cable in addition to a software setting to provide the necessary connector type. Refer to the Serial Pin Assignments section for more details. Differential Input Termination The port on the card has 120-ohm termination of RS-422 differential inputs. Termination is used to increase signal reliability at high speeds (generally 1Mbps or more). At high speeds, receivers at each end of a cable should be terminated.

Serial Connector Pin Assignments The assignment of signals to the connector pins is controlled by the software interface selection. For interface types that use a connector different than DB-25 an adapter cable purchased from MicroGate is required. The following sections describe the software settings and cables for each supported standard. RS-232 The RS-232 standard uses single ended signals on a DB-25 connector. The adapter DB-25 connector follows this standard when the software selects RS-232. Use any straight through 25 conductor DB-25M to DB-25F cable (such as MicroGate Part # CMF000) to connect the adapter connector to the communications equipment. The maximum data rate supported by the adapter when using RS-232 is 128Kbps. Cable length and signal loading may reduce the maximum usable data rate from this value. RS-232 DB-25 Male DTE Signal Name Electrical Desc Direction Earth/Shield Ground 1 TxD, Transmit Data RS-232/V.28 2 Output RxD, Receive Data RS-232/V.28 3 Input RTS, Request to Send RS-232/V.28 4 Output CTS, Clear to Send RS-232/V.28 5 Input DSR, Data Set Ready RS-232/V.28 6 Input Signal Ground 7 DCD, Data Carrier Detect RS-232/V.28 8 Input TxC, Transmit Clock RS-232/V.28 15 Input RxC, Receive Clock RS-232/V.28 17 Input LL, Local Loopback Control RS-232/V.28 18 Output DTR, Data Terminal Ready RS-232/V.28 20 Output RL, Remote Loopback Control RS-232/V.28 21 Output RI, Ring Indicator RS-232/V.28 22 Input AuxClk, DTE Clock Output RS-232/V.28 24 Output Figure 1 RS-232 Cable (Part# CMF000)

V.35 The V.35 standard uses a mix of single ended and differential signals on a 34-pin block connector. To use this standard, select V.35 in software and use the MicroGate V.35 cable (Part # 2534GT, picture shown below). Note that the LL, RL, and RI signals are available on the adapter s DB-25 connector when the V.35 interface is selected, but are not available (NC = no connect) on the 34-pin block connector when using the V.35 cable. The maximum data rate supported by the adapter when using V.35 is 10Mbps. Cable length and signal loading may reduce the maximum usable data rate from this value. V.35 Male DTE Signal Name Electrical Desc DB25 V.35 Block Earth/Shield Ground 1 A Direction TxD (+/A), Transmit Data RS-422/V.11 2 P Output RxD (+/A), Receive Data RS-422/V.11 3 R Input RTS, Request to Send RS-232/V.28 4 C Output CTS, Clear to Send RS-232/V.28 5 D Input DSR, Data Set Ready RS-232/V.28 6 E Input Signal Ground 7 B DCD, Data Carrier Detect RS-232/V.28 8 F Input RxC (-/B), Receive Clock RS-422/V.11 9 X Input AuxClk (-/B), DTE Clock Output RS-422/V.11 11 W Output TxC (-/B), Transmit Clock RS-422/V.11 12 AA Input TxD (-/B), Transmit Data RS-422/V.11 14 S Output TxC (+/A), Transmit Clock RS-422/V.11 15 Y Input RxD (-/B), Receive Data RS-422/V.11 16 T Input RxC (+/A), Receive Clock RS-422/V.11 17 V Input LL, Local Loopback Control RS-232/V.28 18 NC Output DTR, Data Terminal Ready RS-232/V.28 20 H Output RL, Remote Loopback Control RS-232/V.28 21 NC Output RI, Ring Indicator RS-232/V.28 22 NC Input AuxClk (+/A), DTE Clock Output RS-422/V.11 24 24 Output Figure 2 V.35 Cable (Part# 2534GT)

RS-422/RS-449/RS-485/RS-530 The RS-422 and RS-485 standards describe differential electrical signals but not connector or pin assignments. The RS-530 and RS-449 standards define specific connectors and pin assignments using differential signals. The differential signals on the card meet both RS-422 and RS-485 electrical specifications. RS-530 uses differential signals on a DB-25 connector. The adapter DB-25 connector follows this standard when software selects RS-422/485. Use any straight through 25 conductor DB-25M to DB-25F cable (such as MicroGate Part # CMF000) to connect the adapter to RS-530 communications equipment. RS-449 uses differential signals on a DB-37 connector. To use this standard, select RS-422/485 in software and use the MicroGate RS-449 cable (Part # 2537FM). The maximum data rate supported by the adapter when using RS-530 or RS-449 is 10Mbps. Cable length and signal loading may reduce the maximum usable data rate from this value. RS-422/RS-530/RS-449 Male DTE Signal Name Electrical Desc DB25 RS-530 Earth/Shield Ground 1 1 DB37 RS-449 Direction TxD (+/A), Transmit Data RS-422/V.11 2 4 Output RxD (+/A), Receive Data RS-422/V.11 3 6 Input RTS (+/A), Request to Send RS-422/V.11 4 7 Output CTS (+/A), Clear to Send RS-422/V.11 5 9 Input DSR (+/A), Data Set Ready RS-422/V.11 6 11 Input Signal Ground 7 19 DCD (+/A), Data Carrier Detect RS-422/V.11 8 13 Input RxC (-/B), Receive Clock RS-422/V.11 9 26 Input DCD (-/B), Data Carrier Detect RS-422/V.11 10 31 Input AuxClk (-/B), DTE Clock Output RS-422/V.11 11 35 Output TxC (-/B), Transmit Clock RS-422/V.11 12 23 Input CTS (-/B), Clear to Send RS-422/V.11 13 27 Input TxD (-/B), Transmit Data RS-422/V.11 14 22 Output TxC (+/A), Transmit Clock RS-422/V.11 15 5 Input RxD (-/B), Receive Data RS-422/V.11 16 24 Input RxC (+/A), Receive Clock RS-422/V.11 17 8 Input LL, Local Loopback Control RS-232/V.28 18 10 Output RTS (-/B), Request to Send RS-422/V.11 19 25 Output DTR (+/A), Data Terminal Ready RS-422/V.11 20 12 Output RL, Remote Loopback Control RS-232/V.28 21 14 Output DSR (-/B), Data Set Ready RS-422/V.11 22 29 Input DTR (-/B), Data Terminal Ready RS-422/V.11 23 30 Output AuxClk (+/A), DTE Clock Output RS-422/V.11 24 17 Output

Figure 3 RS-530 Cable (Part# CMF000) Figure 4 RS-449 Cable (Part# 2537FM )

RS-530A RS-530A is similar to RS-530, except DTR and DSR outputs are single ended instead of differential. RS-530A Male DTE Signal Name Electrical Desc DB25 RS-530A Earth/Shield Ground 1 Direction TxD (+/A), Transmit Data RS-422/V.11 2 Output RxD (+/A), Receive Data RS-422/V.11 3 Input RTS (+/A), Request to Send RS-422/V.11 4 Output CTS (+/A), Clear to Send RS-422/V.11 5 Input DSR (+/A), Data Set Ready RS-232/V.28 6 Input Signal Ground 7 DCD (+/A), Data Carrier Detect RS-422/V.11 8 Input RxC (-/B), Receive Clock RS-422/V.11 9 Input DCD (-/B), Data Carrier Detect RS-422/V.11 10 Input AuxClk (-/B), DTE Clock Output RS-422/V.11 11 Output TxC (-/B), Transmit Clock RS-422/V.11 12 Input CTS (-/B), Clear to Send RS-422/V.11 13 Input TxD (-/B), Transmit Data RS-422/V.11 14 Output TxC (+/A), Transmit Clock RS-422/V.11 15 Input RxD (-/B), Receive Data RS-422/V.11 16 Input RxC (+/A), Receive Clock RS-422/V.11 17 Input LL, Local Loopback Control RS-232/V.28 18 Output RTS (-/B), Request to Send RS-422/V.11 19 Output DTR, Data Terminal Ready RS-232/V.28 20 Output RL, Remote Loopback Control RS-232/V.28 21 Output AuxClk (+/A), DTE Clock Output RS-422/V.11 24 Output Figure 5 RS-530A Cable (Part# CMF000)

X.21 X.21 is an interface standard using differential signals on a DB-15 connector. To use this standard, select RS-422/485 in software and use the MicroGate X.21 cable (Part # 2515FM). The X.21 signal names are different than those used by the adapter and other interface standards. The mapping of the X.21 signals to the adapter signals are shown in the table below. The maximum data rate supported by the adapter when using X.21 is 10Mbps. Cable length and signal loading may reduce the maximum usable data rate from this value. X.21 Male DTE Signal Name Electrical Desc DB25 Earth/Shield Ground 1 1 DB15 Direction T+, Transmit Data RS-422/V.11 2 2 Output R+, Receive Data RS-422/V.11 3 4 Input I+, Indicator (DSR/DCD) RS-422/V.11 6,8 5 Input Signal Ground 7 8 S-, Clock Input (TxC, RxC) RS-422/V.11 9,12 13 Input I-, Indicator (DSR/DCD) RS-422/V.11 10,22 12 Input X-, Clock Output (AuxClk) RS-422/V.11 11 14 Output T-, Transmit Data RS-422/V.11 14 9 Output S+, Clock Input (TxC, RxC) RS-422/V.11 15,17 6 Input R-, Receive Data RS-422/V.11 16 11 Input C+, Control (DTR) RS-422/V.11 20 3 Output C-, Control (DTR) RS-422/V.11 23 10 Output X+, Clock Output (AuxClk) RS-422/V.11 24 7 Output Figure 6 X.21 Cable (Part# 2515FM )

General Purpose I/O Signals The SyncLink USB has a 24-pin header (2 x 12 pins, 0.050 spacing) inside the case and on the circuit board that provides general-purpose input/output (GPIO) signals for application specific uses. These signals are controlled by an application using the serial API (Windows and Linux). Each signal can be configured to be either an input or an output. Inputs can be monitored and outputs can be controlled. DC GPIO Specifications Vil (input low) = -0.5V min, 0.8V max Vih (input high) = 2.0V min, 5.5V max Vol (output low) = 0.4V max Voh (output high) = 2.4V min Iol (output low) = 24mA max Iil (output high) = -24mA max Input Current = +/- 10uA max GPIO signals are 3.3V TTL compatible and inputs are 5V tolerant. GPIO Pin Assignments Description 1 Ground 2 Ground 3 GPIO[0] 4 GPIO[1] 5 GPIO[2] 6 GPIO[3] 7 GPIO[4] 8 GPIO[5] 9 GPIO[6] 10 GPIO[7] 11 GPIO[8] 12 GPIO[9] 13 GPIO[10] 14 GPIO[11] 15 GPIO[12] 16 GPIO[13] 17 GPIO[14] 18 GPIO[15] 19 GPIO[16] 20 GPIO[17] 21 GPIO[18] 22 GPIO[19] 23 Ground 24 Ground

The SyncLink USB adapter has a total of 20 general purpose I/O signals (GPIO[0] to GPIO[19]). By default on power up all GPIO signals are configured as inputs (direction control = 0). Refer to the serial API documentation for details on configuring and using GPIO signals. The GPIO header is not accessible from outside the standard case. For prototyping, the header can be accessed by removing the case end plate from the USB connector end of the case. This allows space for a ribbon cable to run to the outside of the case. For production, contact MicroGate for a quote on custom end plates and connectors. WARNING: Take care when connecting to GPIO signals to prevent damage to the serial adapter. Outputs should only be connected to inputs and not other outputs. Voltage limits as shown above should not be exceeded.

Frequency Synthesizer The serial controller requires a base clock for the baud rate generator (BRG) to create data clocks. A data clock may be output on the AUXCLK serial signal or used internally for a synchronous data clock, asynchronous sampling clock or for DPLL clock recovery. Fixed Frequency Crystal (Default 14.7456MHz) Reference Clock IDT ICS307-3 Frequency Synthesizer CLK1 (Pin 8) CLK3 (Pin 14) Clock Select 0 = standard 1 = synthesizer MicroGate Serial Controller Base Clock Input Data In (DI) Select (CS) Clock (CLK) GPIO[23] (clock select) GPIO[20] Data GPIO[21] Chip Select GPIO[22] Clock SPI Interface The SyncLink USB has a fixed frequency crystal that drives the reference clock input of a variable frequency synthesizer. The default crystal frequency is 14.7456MHz, and on power up the synthesizer outputs the same frequency on CLK1 (pin 8) which is used as the standard base clock by the serial controller. Other crystal frequencies are available by special order. The serial controller GPIO signals program the synthesizer through an SPI interface and selects between synthesizer outputs. The base clock is common to all ports in the controller. The synthesizer is made by Integrated Device Technologies (IDT). Refer to the documentation available from IDT (www.idt.com) for details on programming the synthesizer. An IDT supplied program (Versaclock 2) generates programming data (132 bit value) for a specific frequency output. Versaclock 3 and later software does not support the ICS307. Contact IDT to get a copy of Versaclock 2. The CLK1 and CLK3 outputs of the synthesizer are used and CLK2 is unconnected. Sample code for programming the synthesizer through the GPIO portion of the serial API is available from MicroGate. The maximum synthesizer frequency supported by the serial controller is 66MHz.