PRODUCT MANUAL. Servomotor controller NOTREP 21 to 26 type to 26 TP /e

Similar documents
Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Three-phase monitoring relay CM-PFE

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

RM4TG20 three-phase network control relay RM4-T - range V

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Safety technique. Emergency stop module BO 5988 safemaster

Pressure transmitter For general industrial applications Model A-10

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Digital inductive conductivity transmitter

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Analog signal converters CC-E I/I Current / current isolators

Technical Data. Dimensions

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Pluggable interface relays CR-P Pcb relays

Digital Controllers ACTUATOR COMPATABILITY

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

SINEAX U553 Transducer for AC Voltage

Electronic overload relay EF19 and EF45

HERZ-Thermal Actuators

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RY2 miniature industrial relays

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Electric Rotary Actuator - On/Off or programmable control actuator

Contact expansion modules

Power Supplies 3. SDN-P DIN Rail Series

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Cable Plug acc. to DIN EN , Form A

Digital input modules

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Electronic overload relay EF65, EF96 and EF146

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Bulletin 150 SMC Flex Smart Motor Controller Specifications

How To Use A Flowmeter

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Kit Watt Audio Amplifier

IMR 6000/10../20../30

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Air damper actuators

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

T0118 T2118 T3118. Instruction Manual

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

MasterINTERFACE 39 Series - Relay interface modules

PHOENIX CONTACT Features

How To Read A Pipe From A Sensor

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Duct Humidity Transmitter

Actuator-Sensor-Interface

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

MOUNTING AND OPERATING INSTRUCTIONS

High-ohmic/high-voltage resistors

High-ohmic/high-voltage resistors

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Transformer oil cooler ALFA A02

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Solenoid valves Type EVU

Redundancy Module QUINT-DIODE/40

650W Single Output Power Supply

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Mounting Instructions. Torque Transducer. A en

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Panel Meters and Controllers Modular Panel Meter Type EDM 35

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

E-STOP relays, safety gate monitors

3753 en /b VE/B - VE/RG Va V riable speed drives

Features. Picture. Specifications

Instruction Manual. T3111 T3111L T3111P T3111Ex

CompactLogix Power Supplies Specifications

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

How To Build A Low Voltage Capacitor Lvcp

Thermistor motor protection

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Transcription:

PRODUCT MANUAL Servomotor controller NOTREP 21 to 26 type 51121 to 26 TP-274813/e APPLICATION - The controllers are used for joint controls of servomotors MODACT with motors of type J9A (16 W), J10A (25 W), J11A (50 W) by Atas elektromotory Náchod a.s. DESCRIPTION The controllers are designed on printed circuit boards in sliding units of the construction kit EGS, refer to Figure1. The unit has two connecting connectors, one for power circuits and the other for signal circuits. On the front cover, there are fuses and holes for access to potentiometers for adjustment. The controllers of type 511 21 and 511 25 represent sliding units that are delivered separately. In case of controllers 511 22 and 511 26, the sliding unit is installed into a box from steel sheet covered with a lid. Wires are brought with sealing outlets. TECHNICAL DATA The device is designed pursuant to ČSN EN 61010-1 as an electrical equipment of protection class I for the application in networks with category of overvoltage in installation II and pollution grade 2. The device has internal and external protective terminals, which are mutually interconnected. The inner source for power supply of the feedback circuit corresponds to the Article 6.3 of the standard and complies with the SELV and PELV circuits. The sliding unit is only designed for building-in. The controllers have a fuse of mains power supply; the controller in box also has an external current protection. Before removing or sliding in the sliding unit, mains power supply shall be switched off. Electric strength: Power circuits: 2200 V AC Signal circuits: 3700 V AC Input circuit for control signal against / feedback input: 500 V AC (type No. 511 25, 26) Power input -without motor max. 20 VA -for motor 50 W approx. 330 VA -for motor 25 W approx. 230 VA -for motor 16 W approx. 150 VA Electric insulation resistance: min. 20 MΩ Power supply: Type of supply mains: 1 / N / PE AC 230 V, 50 Hz Tolerance of supply voltage: ±10 % Tolerance of mains frequency: 48 to 62 Hz Coefficient of upper harmonics: max. 10% Heating period after switching of feeding: 10 minutes Ingress protection: pursuant to ČSN EN 60529: - sliding units: IP 00 - in box: IP 54. - independent sliding units shall be located within Ingress Protection IP 54 Operation position: - discretionary, - for the controllers in box, outlets to be situated downwards Type of operation: continuous Weights of controllers: - Sliding unit: approx. 1.6 kg - In box: approx. 5 kg Applied materials: Frame sliding units galvanic coating Box from steel sheet and painted with grey varnish The product contains precious metals (relay contacts). Input and output terminals of the controllers in box are of a screw type. OPERATION CONDITIONS The device is designed for the environment defined by a group of parameters and their severity grades IE 33/IE 36 pursuant to ČSN EN 60721-3-3, but the level of vibrations only to amplitude 0.15 mm and the following operation conditions. Ambient temperature: -20 to 55 C Relative ambient humidity: 5 to 85 % with upper level of water content 25 g H 2 O/ m 3 of dry air Atmospheric pressure: 70 to 106 kpa Vibrations: - Frequency range [Hz] 10 to 150 - Drift amplitude [mm] 0.15 - Acceleration amplitude [m.s -2 ] 19.6 METROLOGICAL DATA Input control signal - input resistor: 0 to 10 V 60 kω 0 to 20 ma approx. 40 Ω 4 to 20 ma approx. 50 Ω As for the type No. 511 25 and 511 26, the input resistor for the control signal has galvanic separation from the input circuit for the feedback signal. These types have a fixed range for input signals: 4 to 20 ma input resistor approx. 50 Ω Amplification of input signal: continually adjustable in ratio 1 : 4 Proportional band of input signal: max. 1 % at biggest amplification Dead band of input signal: max. ± 0.2 % at biggest amplification within the whole range of operation conditions Feedback signal - input resistor: 0 to 10 ma approx. 40 Ω for types 511 21 and 511 22 4 to 20 ma approx. 50 Ω for types 511 21 and 511 22 4 to 20 ma approx. 50 Ω for types 511 25 and 511 26 Output voltage for servomotor: 0 to min. 209 V at supply voltage AC 230 V In case of a change of the supply voltage, the change of the output voltage is proportional. Carrying capacity of signalling contact: of all types: 30 VA, max. 48 V ELECTROMAGNETIC COMPATIBILITY (EMC) Limit values of interfering voltage: pursuant to ČSN EN 55011: class A, group 1 Electrostatic discharges: pursuant to ČSN EN 61000-4-2: level 3, functional criterion 1 External electromagnetic field: pursuant to ČSN EN 61000-4-3: level 1, functional criterion 2 Fast transient phenomena: pursuant to ČSN EN 61000-4-4: level 2, functional criterion 2 Surge impulse: pursuant to ČSN EN 61000-4-5: level 2, functional criterion 2 Magnetic fields of mains frequency: pursuant to ČSN EN 61000-4-8: level 5, functional criterion 1 1 / 10

TP - 274813/e Product manual, type 51121 to 26 DESIGNATION Data on the controller: - Trade mark of the manufacturer - Made in Czech Republic - Product number - Manufacturing number - Type of supply mains - IP grade - CE mark DELIVERY Unless agreed otherwise with the customer, each delivery includes - Delivery note - Products pursuant to the purchase order - The controllers are delivered with interconnecting tips for the selection of ranges, feedback and monitoring of interruption of signals pursuant to the table of designs - Two connector sockets are delivered with the sliding unit - Accompanying technical documentation in Czech in the following scope: - Product quality and completeness certificate (it declares compliance with Technical conditions and also serves as the warranty certificate) - Installation, operation and maintenance manual - Delivery note If it is established in the purchase contract or agreed otherwise, the following documentation can be also delivered with the product - EC Compliance Certificate - Other documents RELIABILITY The informative value of mean time between failures is 90,000 hours. The mean service life is 10 years. PACKING The device and accessories are packed pursuant to controlled packing regulations identified by the technological procedure for the applicable product. The devices are delivered in a packing ensuring resistance to the impact of thermal effects pursuant to ČSN EN 60654-1 and mechanical effects pursuant to ČSN IEC 654-3. TRANSPORT The devices may be transported on conditions corresponding to the set of combinations of classes IE 21 pursuant to ČSN EN 60721-3-2. STORAGE The devices may be stored on conditions corresponding to the set of combinations of classes IE 11 pursuant to ČSN EN 60721-3-1. The devices may be stored at ambient temperature from 0 to 35 C with relative air humidity 75% with max. content of 22g H2O/m3 of dry air. Air may not contain other substances causing corrosion. The storage life is max. 12 months. After this period, control piece tests shall be performed. ORDERING The purchase order shall specify - Name - Product ordering number - Number of pieces TABLE OF DESIGNS SPECIFICATION ORDERING NUMBER 511 xxx 001 With current sliding unit 210 feedback in box 220 With galvanic sliding unit 250 separation in box 260 PURCHASE ORDER EXAMPLE - Servomotor controller - 511 210 001-5 pcs INSTALLATION AND CONNECTION Dimensional drawings are specified in Figures 1 and 2. The sliding units themselves are slid in the tanks EGS. They are connected with connectors. The controllers in box are connected onto a wall by four screws pursuant to the dimensional drawing. They are connected by means of the terminal board. To enable the installation, it is possible to place inserts behind the controllers of line 511 02, 511 07, 511 09 pursuant to the drawing in Figure 2. The set of 2 inserts, 4 screws, 4 nuts and 4 washers is delivered with the ordering number 405 035 464 015. Connection schemes of controllers are specified in Figure 4. Cu wires with insulation resistance min. 20 MΩ are used for the connection of input signals. These wires may not be placed together with power supply wires. To connect the devices to the power supply mains, insulated copper wires dimensioned pursuant to ČSN 33 2000-4-43 shall be used. The installation at the device shall include a switch or a circuit breaker enabling to disconnect the device from the power supply mains. After the connection, all outlets shall be sealed with a suitable sealing material, e.g. Colorplast. COMMISSIONING The servomotor is expected to be adjusted in the manufacturing plant. The required range of the input control and feedback signal is selected pursuant to Figure 4. Adjusting controllers 511 21, 511 22, 511 25 and 511 26: The controller is switched over to manual control and the maximum proportional band is adjusted with potentiometer P. Milliammeter shall be connected serially to terminal L (6) of the servomotor (plus on wire to the controller). The servomotor shall be switched over to zero position and current shall be zero in this position. Otherwise it is necessary to adjust the induction transmitter at the servomotor mechanically in order to achieve zero current. Then readjust the servomotor to the other limit position, in which current shall correspond to the end of the range. Possible small deviations in this position can be corrected with a potentiometer located in the induction transmitter. The servomotor shall be readjusted to the position, in which current measured by the milliammeter equals to one half of the range of the feedback signal. Bring 50 % signal, for which the controller is adjusted, to the control input of the controller. The controller shall be switched over to automatic control. The servomotor shall settle in 50 % position. In case of a change of the input signal, the position is changed. If the servomotor rotates regardless of the input signal to any extreme position, the feedback in the control loop is positive. In this case, switch off the mains and replace inlets to terminals I, G (2, 6) of the servomotor. Note: After the adjustment, it is possible to increase amplification in loop by potentiometer P, as required, and stability shall be considered. In case of using signal 4 to 20 ma, it is possible to use circuit for monitoring drop-out of these signals. Monitoring is selected pursuant to the table SELECTION OF RANGES OF CONTROLLERS, type 511 21 to 511 26. 2 / 10

TP - 274813/e Product manual, type 51121 to 26 DELIVERY OF CONTROLLERS FROM FACTORY The controllers in box are delivered with pre-selected ranges: Type 511 22 511 26 Input signal 4 to 20 ma 4 to 20 ma Feedback 4 to 20 ma 4 to 20 ma Signal interruption control ON ON Tips A - B are not connected for all types, i.e. manual control is introduced. SELECTION OF RANGES OF CONTROLLERS, TYPE 511 21 TO 511 26 It is realized by: - Interconnection of tips on signal connector for 511 21 and 511 25 - Interconnection of soldering tips on interconnection bar for 511 22 and 511 26. Type Signal to be connected 511 21 and 511 22 511 25 and 511 26 Feedback Input signal 4 to 20 ma 4 to 20 ma A21 - A23 0 to 20 ma A21 - A23, C23 - C25, A11 - C11 0 to 10 V A21 - C21, A11 - C11 Feedback 0 to 20 ma A25 - A27 4 to 20 ma A21 - A23, C11 - C13 Input signal Feedback Input signal 0 to 20 ma A21 - A23, C23 - C25 0 to 10 V A21 - C21 4 to 20 ma 4 to 20 ma A21 - A23 MONITORING OF SIGNAL INTERRUPTION 4 to 20 ma: Type Input signal Feedback 511 21, 511 22 C7 - C5 A5 - C5 511 25, 511 26 C7 - C5 or S2 A5 - C5 or S1 Manual control is eliminated by interconnecting tips A - B on the power board, refer to the Annex. OPERATION AND MAINTENANCE The device does not require any operation and maintenance. SPARE PARTS The design of the device does not require any delivery of spare parts. REPAIRS The repairs shall be realized by the manufacturer. The devices shall be sent for repair in the original or equal packing without accessories. 3 / 10

Annex 1 Sheet 1/2 Block scheme of controllers 511 21 and 511 22 with current feedback generátor of ignition impulses Modact-variant Manual control Servo amplifier Stabilized sources Interconnecting bar of range selection of controller 51122 Power supply of in induction transmitter Failure signals Feedback Input signal Power connector S1 Signal connector S2 4 / 10

Annex 1 Block scheme of controllers 511 25 and 511 26 Sheet 2/2 generátor of ignition impulses Modact-variant Manual control Servo amplifier Stabilized sources Interconnecting bar of range selection of controller 51126 Power supply of in induction transmitter Failure signals Feedback Input signal Power connector S1 Signal connector S2 5 / 10

Figure 1 Dimensional drawing of slide-in units of controllers, type 511 21 and 511 25 Signal connector S2 Amplification Fuses Power connector S1 It corresponds to construction kit EGS 6 / 10

Figure 2 Dimensional drawing of controllers in box, type 511 22 and 511 26 Detail of connection with insert 7 / 10

Figure 3 Connection scheme of controllers with servomotor in design "KBNS" New design of servomotor connection Power connector S1 Signal connector S2 Failure signalling Feedback Input signal Manual control 1 Connectors of controller 511 21 (511 25) 2 Terminal board of controller 511 22 (511 26) 3 Plug KBNS of servomotor MPR with induction transmitter 4 Interconnecting bar of range selection of controller 511 22 (511 26) Induction transmitter Old design of servomotor connection 8 / 10

Figure 4 Connection scheme of controllers with servomotor in design "terminal board" New design of servomotor connection Old design of servomotor connection Manual control Power connector S1 Signal connector S2 Failure signalling Feedback Input signal Induction transmitter 1 Connectors of controller 511 21 (511 25) 2 Terminal board of controller 511 22 (511 26) 3 Terminal board of servomotor MPR with induction transmitter 4 Interconnecting bar of range selection of controller 511 22 (511 26) 9 / 10

Figure 5 Drawing of location of connectors, terminal board and interconnecting bar in box of controllers, type 511 22 and 511 26. S1 Power connector S2 Signal connector S3 Terminal board S4 Interconnecting bar March 2006 ZPA Nová Paka, a.s. 10 / 10