HDSL Basics. HDSL Basics. Introduction. HDSL Overview



Similar documents
Introduction to Digital Subscriber s Line (DSL)

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS

Advanced Signal Processing 1 Digital Subscriber Line

T-BERD 107A. T-Carrier Analyzer

T1 Networking Made Easy

Broadband 101: Installation and Testing

How To Test A Ds1 Signal

Appendix D T1 Overview

The Common Test Patterns described below are used to test DS1 interfaces upon initial installation and after repair.

Copper Testing for ADSL/2/2+ Qualification and troubleshooting of the local loop

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below:

Fundamentals of Telecommunications

Cell Master MT8212A T1 Measurements CELL MASTER

UltraFED IIB. 30 MHz Far-End Device

How To Power A Powerline System On A Cell Phone Or Ipad Or Ipa Computer (For A Cell)

WHITE PAPER December, 2001

Digital Subscriber Line (DSL) Transmission Methods

T1 Network Technology. Essentials for Successful Field Service Technicians

ADSL2 AND ADSL2plus THE NEW ADSL STANDARDS

T1 Basics. T1 Basics. Introduction. Why is T1 in Demand? Overview. Simplification

Adaptive Spectrum and Signal Alignment, Incorporated THE RE-PROFILER DSM CLOSES THE CASE ON DIAGNOSING DSL/VDSL TROUBLES

COMMITTEE T1 TELECOMMUNICATIONS Working Group T1E1.4 (DSL Access) Ottawa, Canada; June 7, 1999

Optimal Transmit Spectra for Communication on Digital Subscriber Lines

Intel System Engineers Documents. DSL General Overview

Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.

Acterna DSL Services Tester TPI 350+ Application Highlights

The Fundamentals of DS3

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE WORKING GROUP ON COMMON CONNECTION STANDARDS (CCS)

(Refer Slide Time: 2:10)

- T-Carrier Technologies -

INTRODUCTION TO DSL CHAPTER THE TELEPHONE LOOP PLANT. 1.1 The Telephone Loop Plant. 1.2 DSL Reference Model. 1.3 The Family of DSL Technologies

Chapter 4 T1 Interface Card

The Conversion Technology Experts. Media Conversion: Cost-Effectively Integrating T1 into your Fiber Network

Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)

ADSL over ISDN, DAML, and Long Loops

COMMITTEE T1 TELECOMMUNICATIONS Working Group T1E1.4 (DSL Access) Costa Mesa, California, March 8 12, 1999

Testing VF Circuits at T1 Access Points with the T-BERD 224

Analysis Techniques for Loop Qualification and Spectrum Management

ADSL TUTORIAL. Figure 1: Typical DSL system.

1. Overview. 2. F-bit Utilization

T1E1.4/98-004R2 DRAFT ANSI T Revision of ANSI T American National Standard for Telecommunications

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS

MSB MODULATION DOUBLES CABLE TV CAPACITY Harold R. Walker and Bohdan Stryzak Pegasus Data Systems ( 5/12/06) pegasusdat@aol.com

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

Multiplexing on Wireline Telephone Systems

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

Nexus Technology Review -- Exhibit A

CHAPTER 8 MULTIPLEXING

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management

Voice---is analog in character and moves in the form of waves. 3-important wave-characteristics:

RADIO FREQUENCY INTERFERENCE AND CAPACITY REDUCTION IN DSL

Physical Layer, Part 2 Digital Transmissions and Multiplexing

Black Box Explains: DSL

technical note T1 Basics

Lecture 12 Transport Networks (SONET) and circuit-switched networks

INTERNATIONAL TELECOMMUNICATION UNION

BROADBAND AND HIGH SPEED NETWORKS

FST-2207 TestPad T1/T3 Wireless Module Isolate network problems to speed-up wireless network testing

How To Understand And Understand The Power Of A Cdma/Ds System

Transformer-coupled passive transmit path with a fixed insertion loss of approximately 1.0dB.

CS263: Wireless Communications and Sensor Networks

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE TSAC WORKING GROUP ON NEW STANDARDS AND POLICY (NSP)

FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below:

TCOM 370 NOTES 99-6 VOICE DIGITIZATION AND VOICE/DATA INTEGRATION

Introduction to ADSL. NEXTEP Broadband White Paper. Broadband Networks Group. A primer on Asymmetric Digital Subscriber Line transmission technology.

HST-3000 DS3 Service Interface Module (SIM)

Sol: Optical range from λ 1 to λ 1 +Δλ contains bandwidth

Advanced Test Equipment Rentals ATEC (2832)

2-Pair HDSL1 Adtran Fiber Optic Link System

F2400 FOM II Series Fiber Optic Modem Technical Manual

Analog vs. Digital Transmission

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Current access technologies overview

Revision of Lecture Eighteen

VDSL2 A feasible Solution for Last Mile

Video Conferencing Glossary of Terms

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

SHDSL in Ericsson ENGINE Access Ramp

TUTORIAL FOR CHAPTER 8

Benefits of Using T1 and Fractional T1 Carriers and Multiplexers Gilbert Held

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

Performance Management and Fault Management. 1 Dept. of ECE, SRM University

Next Generation of High Speed. Modems8

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

How To Test A Network For Fault Tolerance

Course 12 Synchronous transmission multiplexing systems used in digital telephone networks

Managing High-Speed Clocks

APPLICATION NOTE 182 WIDEBAND TESTING. Telecom Test and Measurement. The Need for Speed

HST-3000 Wireless Services Applications

INTERNATIONAL TELECOMMUNICATION UNION

Bluetooth voice and data performance in DS WLAN environment

Non-Data Aided Carrier Offset Compensation for SDR Implementation

KVM Cable Length Best Practices Guide

Orion2+ SHDSL.bis Solution with 11Mbit/s and 15Mbit/s per Copper Pair

TR-013 Interfaces and System Configuration for ADSL Central Office Issue: 1.0 Issue Date: January 1999

Configuring E1 and T1 Interfaces

Transcription:

1 Introduction Providing T1 service is a competitive race, and High-bit-rate Digital Subscriber Line () is quickly emerging as the ideal solution to remain a step ahead. Currently touted as repeaterless T1, enables T1 service to travel up to 12,000 ft. on copper cable without regeneration. When used with a single doubler, service can be extended to 24,000 ft. By eliminating T1 line repeaters and fault locate pairs, can provide service in as little as 24 hours over two existing POTS lines. This enables established service providers to meet the demands for quicker turn-ups and improved service quality over the installed base of copper cable. The increase in efficiency comes without sacrificing service quality as features several enhancements that eliminate the common problems associated with standard T1 transmission. enables established service providers to remain competitive while reducing operational costs. This Technical Note provides an overview of technology, a detailed discussion of how works, and recommended test procedures that can guarantee consistent performance. Overview The standard loop architecture, shown in Figure 1A, is a point-to-point circuit that consists of two transmission units (HTUs). The [HTU at the central office (CO)] replaces the T1 office repeater and fits easily into any standard 220 office repeater bay. The (remote HTU) can be installed with, or replace, the network interface unit (NIU) at the customer demarcation point. The HTUs are then connected by two non-loaded copper cable pairs. If the local loop exceeds 12,000 ft., a doubler can be installed, as shown in Figure 1B, on the next page, to extend service up to 24,000 ft. Central Office Customer Premise DS-1 Loop 1 NIU/CPE Loop 2 Figure 1A Point-to-point circuit.

2 Central Office Customer Premise DS-1 Loop 1 Doubler Loop 1 NIU/CPE Loop 2 Loop 2 Figure 1B Extending service with a doubler. Under normal operation, the receives a standard T1 signal on Side 1 from the DS-1. The derives timing and converts the T1 into two signals, each representing half the T1 bandwidth. The signals are then transmitted on Loop 1 and Loop 2. The receives the signals, reconverts them to a single T1 signal, and sends it to the customer on Side 1. The process is then reversed on Side 2, toward the CO. The receives a standard T1 on Side 2 from the channel service unit (CSU) at the customer premises. It derives timing and converts the T1 into two signals, each representing half the T1 bandwidth. The signals are then transmitted on both loops. The receives the signals, reconverts them to a single T1 signal, and sends it to the DS-1 on Side 2. In order to transmit and receive on the same pair, the HTUs utilize transceivers rather than the separate transmitter and receiver used by standard T1 equipment. Figure 2 depicts this process. The Conversion Process Upon receiving a standard T1 from the DS-1, the completes its conversion to in four steps: timing recovery, mux/demux, data scrambling, and applying overhead. Like most other local loop equipment, the recovers timing from the network. The receives the incoming T1 signal, and the signal is sent through a phase-locked loop circuit. This enables timing to be recovered from the T1 signal itself. This process requires the signal to have a minimum pulse density. ANSI T1.403 defines this requirement with two rules: the incoming signal must contain at least 12.5% ones density, and the signal must contain no more than 15 consecutive zeros. After the has derived timing, it divides the incoming T1 into two signals, as shown in Figure 3. The T1 is demultiplexed into 24 DS0s and re-multiplexed into two separate signals. Each signal contains 12 of the 24 DS0s and represents 768 kb/s of T1 bandwidth. The DS0s are typically regrouped with DS0s 1-12 in one signal and DS0s 13-24 in the other. Some vendors, however, allow users to prioritize each DS0. This enables the 12 highestpriority DS0s to remain up and running, if one of the two loops is dropped. A pseudorandom data scrambling algorithm is applied to both signals to control ones density. Each signal contains an optimum ones density, regardless of the incoming T1 data. This ensures the at the far-end will easily maintain synchronization with the.

3 Loop 1 NIU/CSU Loop 2 Figure 2 Transmitting signals. 1.544 Mb/s T1 LIU T O 784 kb/s i Multiplexer and CVR m Scrambler i n g R e c o v e r y v e r h e a d CVR 784 kb/s 784 kb/s 1.544 Mb/s 784 kb/s Figure 3 Dividing the incoming T1. Finally, 16 kb/s of overhead is applied to each signal producing a total bit rate of 784 kb/s. This overhead includes framing, CRC error checks, and a proprietary embedded operations channel. Signal Encoding transmission utilizes a 2-Binary 1-Quaternary (2B1Q) signal encoding scheme, which is also used by Basic Rate ISDN. 2B1Q represents two bits with each pulse, as Figure 4, on the next page, shows. Each pulse can be any of four possible signal levels. Once encoded, the transmits Signals 1 and 2 on Loops 1 and 2, respectively. Each of the signals are received by the, re-converted into a standard T1 by reversing the above process, and sent to the customer. The use of technology to deliver T1 service is, therefore, transparent to the customer.

4 3 1 0-1 -3 2B1Q () Figure 4 2B1Q signal encoding. 0 1 1 1 1 0 1 1 0 1 0 0 0 1 1 1 1 0 1 1 1 0 AMI (T1) the signal s Nyquist (center) frequency, the greater the distance it can travel. For example, a 56 kb/s signal, having a Nyquist frequency of 28 khz, can travel much further than a T1 signal having a Nyquist frequency of 772 khz. -1 This process is repeated when transmitting from the customer to the network. Upon receiving the standard T1 from the customer premises, the completes the same conversion process. Both signals are encoded with a 2B1Q format and transmitted on both loops. How Does Improve Performance? A decreased frequency of operation and several enhancements that correct for common problems inherent in standard T1 transmission help to provide superior service. Some of these problems are repeater reliability, pulse density, bridged taps, and degrading splices. Lower Frequency The conversion process from T1 to centers on a basic transmission theory that relates a signal s frequency to the distance of transmission: the lower As previously described, splits the incoming T1 into two separate data streams reducing the overall bit rate from 1.544 Mb/s to 784 kb/s per loop. Decreasing the overall bit rate and encoding with 2B1Q combine to reduce the Nyquist frequency of transmission from the 772 khz of standard T1 to 196 khz, see Table 1. The lower Nyquist frequency enables to travel up to 12,000 ft. as opposed to 6,500 ft. with standard T1. This additional range enables service providers to reach approximately 80% of their customers without deploying line repeaters. The lower frequency of transmission provides additional benefit by being less susceptible to cable impairments. In general, the higher a signal s frequency, the more vulnerable it is to cable faults. As in the previous example, the Nyquist frequency of a 56 kb/s signal is only 28 khz, while T1 is 772 khz. If the above theory holds true, then a 56 kb/s circuit should have fewer testing restrictions placed on it than a T1 and it does. Controlled Pulse Density also proves superior to T1 by reducing the concerns related to pulse density in the outside plant. ANSI T1.403 requires that standard T1 bandwidth contain a minimum of 12.5% ones density and no more than 15 consecutive zeros to ensure that common trans-

5 Standard T1 User Bandwidth/Overhead 1.544 Mb/s 1.544 Mb/s Transmission Rate 1.544 Mb/s 784 kb/s (2 loops) Pulse Level Combinations 2 (AMI) 4 (2B1Q) Nyquist Frequency 772 khz >> 196 khz Table 1 Reducing the Nyquist frequency of T1. mission equipment will receive adequate pulse density to recover timing from the network. In addition, low pulse density reduces a T1 signal s ability to pass physical faults such as one-side opens and degrading splices. Conversely, high pulse densities stress the power output of common equipment and occasionally induce crosstalk noise on adjacent pairs. Commonly used stress patterns (e.g., 3 in 24, 1:7, and ALL ONES) have been developed to proactively locate such problems and are often used during span qualification. compensates for these inherent problems by introducing the incoming T1 to a pseudorandom data scrambling algorithm within the conversion process. This algorithm ensures a healthy pulse density within the outgoing signals regardless of the incoming T1 data. Echo-cancellation Bridge taps, a frequent nemesis of T1, also play a role in impairing transmission. Bridge taps can impose signal problems at specific frequencies. These frequencies vary with each bridge tap. They are defined by the distance to the tap, the length of the tap, and the termination of the drop. Each HTU includes echocancellation circuitry that corrects for the effects of bridge taps. Upon transmitting a frequency that activates a bridge tap, the tap impairs the signal by introducing reflections of energy (known as echoes) back toward the source. The purpose of echo-cancellation circuitry is to detect such echoes and adjust itself to cancel them out, thereby reducing their effects on live traffic. Adaptive Digital Filtering Adaptive digital filtering is also useful in reducing the effects of physical faults in the outside plant. Environmental elements such as water and humidity can cause copper cable and splices to degrade. Over time, this degradation introduces signal noise to the service that the cable supports. Adaptive digital filtering corrects for this process by routinely monitoring the signals for unwanted noise and adapting itself to filter it out. This reduces the need to perform periodic testing on high-priority cable pairs to detect degradation. The Requirements for Loops If transmission is superior to T1, what are its limitations? The physical requirements of the loops are defined by Carrier Serving Area (CSA) specifications which describe total loop length, bridge tap length, and gauge changes. CSA specifications state that the total loop length must be less than or equal to 12,000 ft. for 22/24 AWG cable and less than or equal to 9,000 ft. for

6 26 AWG cable. This total cable length also includes the length of any bridge taps on the loop. For example, a loop of 11,730 ft. with a 1,000 ft. bridge tap does not meet CSA requirements, as the total loop length exceeds 12,000 ft. testing techniques to enable you to quickly identify and locate why the HTUs would fail. As with most other digital services, loops can be tested by performing two basic tests: testing the physical cable pairs and determining the actual signal quality. In addition, the total length of all bridge taps on the span must total less than 2,500 ft. with no single tap exceeding 2,000 ft. A span containing eight 60 ft. bridge taps is CSA compliant while a loop containing one 2,400 ft. bridge tap is not. Finally, the loop must be nonloaded and contain a maximum of two gauge changes. Special attention should be paid to bridge taps that are extremely close to each HTU. For example, a bridge tap within 100 ft. of a can impair the signal even if the loop meets CSA requirements. The closer the bridge tap is to the HTU, the more likely it is to return reflections that contain more energy than the incoming data pulses from the other HTU. If this occurs, the echo-cancellation circuitry will be unable to distinguish between data and unwanted reflections. Testing What happens if the HTUs are inserted into their respective slots; their test sequence is initiated; and it fails? This section defines some recommended One common technique for testing the physical cable pairs is performing an end-to-end loss test at the service s Nyquist frequency, as shown in Figure 5. This measurement assures proper signal level at the customer demarcation point and approximates signal performance. The Nyquist frequency of is 196 khz and most HTU equipment cannot withstand greater than -36 db of loss. This test requires two transmission impairment measuring set (TIMS) test instruments. Although these sets do an adequate job of approximating signal performance, they provide very little, if any, information about the type or location of a fault. Efficient fault location requires additional test equipment to complement a TIMS, such as a time domain reflectometer (TDR). Another common method of testing for physical faults on loops is to first measure the total loop length, including bridge taps, and then measure the total loop length without bridge taps. The total loop length, including bridge taps, can be approximated by measuring loop capacitance and referring to a conversion table. Some products will complete the conversion for you and simply display a result in feet. Note that making an accurate measurement in either case requires an open at the far-end of the loop. Total loop length without bridge taps is best approximated by mea- T-BERD 209OSP Tx T-BERD 209OSP Rx 196 khz PDB Figure 5 Nyquist frequency for.

7 suring the resistance between tip and ring and referring to a conversion table. This measurement requires a short at the far-end of the loop. Upon completing these two measurements, you can verify the total loop length and total bridge tap length meet CSA specifications. If CSA requirements are not satisfied, a TDR can be used to locate any applicable bridge taps, shorts, opens, or load coils. Since this method requires only one test set, it proves to be more efficient. Figure 6 describes measuring loop length. Upon verifying the cable pairs, a bit error rate (BER) test should be performed between the DS-1 and the customer demarcation point. Although stress patterns have little effect on transmission, ANSI T1.403 requires the service provider to adequately qualify the circuit, as it is still a T1 service being delivered to the customer. In addition, each HTU s T1 receiver actually derives timing from the incoming pulses; therefore, patterns such as 3 in 24 can prove quite useful in locating faulty equipment. Each HTU responds to a variety of loopback codes, so these tests can be completed with a single T1 test set. To properly qualify a T1 service, ANSI T1.403 recommends testing the ALL ONES pattern for five minutes, 3 in 24 for five minutes, and the QRSS pattern for 15 minutes. With the recent emergence of doublers, it is often a requirement to test for signal quality prior to installing the CO equipment. This test is typically performed in order to verify the doubler is working and installed properly. When completing this test, it is com- mon to access the span at the main distribution frame () and emulate the with a BER test set. It is important to recognize this test set must also be able to provide loop current to power the doubler. Once connected, the test set can loop up the doubler and qualify its proper operation by means of a BER test. Figure 7, on the next page, depicts this test application. A final issue in testing is crosstalk noise measurements. The signal spectrum for, as shown in Figure 8 on the next page, ranges from approximately 40 khz to 390 khz. Although this range doesn t contain the Nyquist frequency of any other common services, it does overlap with 56 kb/s, 64 kb/s, Basic Rate ISDN, and T1 signal spectrums. This fact implies that near-end crosstalk (NET) from these servies may induce noise upon live traffic or vice versa. For example, if the HTUs report a consistently high S/N ratio during normal operation, the problem might very well be NET. Conversely, most physical faults will typically cause fluctuating S/N readings due to the adaptive digital filtering. Isolating this trouble requires taking the circuit out-of-service and measuring the noise power residing on the pair induced from other signals in the same bundle. The T1/E1 group has defined the F bandpass filter for performing this measurement. A TIMS set equipped with the F filter is able to measure only the noise power that resides within the signal spectrum, providing a true measurement for the presence of relevant NET. T-BERD 209OSP Tx PDB Figure 6 Measuring loop length.

8 Doubler Figure 7 BER testing with a doubler. Doubler Power Supply T-BERD 209OSP Rx Tx Figure 8 signal spectrum. DDS ISDN T1 28 khz 40 khz 196 khz 772 khz Tx Frequency These quick qualification tests will guarantee the cost savings and service benefits that offers. However, is a very cost-driven technology and the advantages begin to dwindle if service providers must spend upwards of $20,000 to purchase a TIMS set, TDR, and T1 test set for each applicable technician. A solution to this predicament is the T-BERD 209OSP and the T-BERD Doubler Power Supply, which meet all the above requirements for a much lower price. Conclusion provides the unique ability to extend the life of copper cable while providing distinct improve- ments in service quality. This implies that will prove to be a strategic tool in the increasingly competitive T1 service market but only for those who can support it effectively. NOTE: Specifications, terms, and conditions are subject to change without notice. 1997 Telecommunications Techniques Corporation. All rights reserved. Telecommunications Techniques Corporation, TTC, and T-BERD are registered trademarks of Telecommunications Techniques Corporation. All other trademarks and registered trademarks are the property of their respective companies.