E. Polyethylene Sheet or Tube Encasement: STD SPEC F. Fusion-Bonded Epoxy Lining and Coating: STD SPEC

Similar documents
SECTION DUCTILE-IRON PIPE AND FITTINGS

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION PVC PRESSURE PIPE AWWA C900

STANDARD SPECIFICATION SECTION STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED

STANDARD SPECIFICATION SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900)

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Suggested Specifications: Steel Pipe for Water Transmission

Ductile Iron Pipe Couplings

SECTION STORM DRAINAGE SYSTEM

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

DRESSER TM PIPELINE SOLUTIONS

SECTION FIRE HYDRANTS

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

WATER SERVICE 2

SECTION GROUND WATER STORAGE TANKS

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

SECTION SANITARY SEWER PIPE

SECTION PIPE HANGERS AND SUPPORTS

SECTION 15 AIR RELEASE VALVE ASSEMBLIES General

Fire Hydrant Troubleshooting

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

RMF Engineering

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Wastewater Capital Projects Management Standard Construction Specification

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

James M. Pleasants Company

RING JOINT SYSTEMS 207

INDEX. Sec. No. Items Page Nos.

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

Section Four: Linings and Coatings

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

FLANGED END BALL VALVE

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Section SEWER PIPE INSTALLATION AND TESTING

Ford Pipe Repair Products The Ford Meter Box Company, Inc.

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

TECHNICAL SPECIFICATION

SECTION FACILITY STORM DRAINAGE PIPING

STANDARD SPECIFICATIONS SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE. 1. Trenching, Backfilling, and Compacting: 02223

DESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4

Section C-1 Pipes and Fittings

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

American- Darling 5¼" B-84-B-5.

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Mechanical Installation

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

DESIGN CLARIFICATION (DC)

Mechanical Joint Restraints

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Dresser * Pipeline Solutions

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Pipe Repair Products A complete selection for all types of pipe

Acceptance Codes APPENDIX - A. Acceptance Criteria

Toroidal Conductivity Sensor

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Pipe Repair Products. For Water, Wastewater and Industrial Piping Systems. Custom Fabrication

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

Manufacturing, Supply & Quality Plan for Tower Bolts. SL Tower Bolt Market Penetration

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

JCM GENERAL PRODUCT DIRECTORY Effective March 1, 2010 Replaces 01/12/2007

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Quality & Innovation, Manufactured in the U.S.A.

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

DYNA RIDER FOOTBOARD KIT

Valve Live Loading With Belleville Springs. Belleville Springs for Valve Live Loading

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

PRESSURE REDUCING CONTROL VALVE

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

TARIFF CODE and updates standard

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

NORSOK Compact Flange Installation and Assembly Procedure

A. This Section includes the following for soil, waste, and vent piping inside the building:

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

Transcription:

STANDARD SPECIFICATION SECTION 15122 FLEXIBLE PIPE COUPLINGS PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of flexible pipe couplings for steel pipe, PVC pressure pipe, PVC distribution pipe, and ductile iron pipe. 1.02 RELATED WORK SPECIFIED ELSEWHERE A. Standard Drawings. B. Record Drawings and Submittals: STD SPEC 01300. C. Painting and Coating: STD SPEC 09900. D. Cold Applied Wax Tape Coating: STD SPEC 09952. E. Polyethylene Sheet or Tube Encasement: STD SPEC 09954. F. Fusion-Bonded Epoxy Lining and Coating: STD SPEC 09961. G. Corrosion Control for Buried Piping: STD SPEC 13110. H. General Piping Requirements: STD SPEC 15050. I. Disinfection of Piping: STD SPEC 15141. J. Pressure Testing of Piping: STD SPEC 15144. 1.03 SUBMITTALS A. Submit submittal packages in accordance with Standard Specification Section 01300. B. Submit manufacturer's catalog data, descriptive literature, and assembly drawings. Show manufacturer's model or figure number for each type of coupling or joint for each type of pipe material for which couplings are used. C. Submit manufacturer's recommended torques to which the coupling bolts shall be tightened. D. Show dimensions, materials of construction by specification reference and grade, linings, and coatings. E. Show number, size and material of construction of the rods and lugs for each joint harness on the project. FLEXIBLE PIPE COUPLINGS STD SPEC 15122-1

PART 2 - MATERIALS 2.01 COUPLING SYSTEM DESIGN AND COMPONENT UNIT RESPONSIBILITY Gaskets, bolts, nuts, glands, end rings, and hardware for pipe couplings of all types shall be furnished by the manufacturer of the pipe coupling and shall be designed as an integral system by the pipe coupling manufacturer. Gaskets shall be designed for the coupling and appropriately sized to provide a watertight seal at the design pressure and temperature. Gaskets, bolts, nuts, glands, end rings, and hardware for pipe couplings shall be shipped with the pipe coupling and shall be clearly labeled indicating the origin of the material, including place and date of manufacture. Manufacturer's printed installation instructions shall be packaged with each pipe coupling. 2.02 STEEL FLEXIBLE PIPE COUPLINGS A. Steel couplings shall have center sleeves and end rings made of carbon steel conforming to AWWA C219, Section 4. Minimum center sleeve length shall be 5 inches for pipe sizes 3/4-inch through 4-1/2 inches; 7 inches for pipe sizes 5 inches through 24 inches; and 10 inches for pipe sizes larger than 24 inches. B. Sleeve bolts in exposed service or buried shall be Type 304 stainless steel per AWWA C219, Section 4. C. Steel end follower rings shall be cast, forged, or hot rolled in one piece. Do not use rings fabricated from two or more shapes. D. Wall thickness of sleeve shall be at least that specified for the size of pipe in which the coupling is to be used. E. Gaskets shall be Buna-N. 2.03 DUCTILE IRON FLEXIBLE PIPE COUPLINGS A. Couplings shall have center sleeves and end rings made of ductile iron conforming to AWWA C219, Section 4. B. Sleeve bolts in exposed service or buried shall be Type 304 stainless steel per AWWA C219, Section 4. C. Gaskets shall be Buna-N. 2.04 FLEXIBLE PIPE COUPLINGS FOR PLAIN END STEEL PIPE Couplings shall be steel, Dresser Style 38, Smith-Blair Type 411, Baker Series 200, or District approved equal. 2.05 FLEXIBLE PIPE COUPLINGS FOR PLAIN END DUCTILE IRON PIPE, PVC PRESSURE PIPE, OR PVC DISTRIBUTION PIPE Couplings shall be ductile iron, Dresser Style 153, Smith-Blair Type 441, Baker Series 228, or District approved equal. FLEXIBLE PIPE COUPLINGS STD SPEC 15122-2

2.06 TRANSITION COUPLINGS Couplings for connecting different pipes having different outside diameters shall be steel: Dresser Style 62 or 162, Smith-Blair Series 413 or 415, Baker Series 212 or 220, or District approved equal. Couplings shall have an integral full circumference ring pipe stop at the midpoint of the coupling. Inside diameter of coupling pipe stop shall equal inside diameter of smaller diameter pipe. 2.07 FLANGED COUPLING ADAPTERS FOR STEEL PIPE Adapters shall be steel, Dresser Style 128, Smith-Blair Type 913, Baker Series 602, or District approved equal. Flange ends shall match the flange of the connecting pipe. 2.08 FLANGED COUPLING ADAPTERS FOR DUCTILE IRON PIPE, PVC PRESSURE PIPE, OR PVC DISTRIBUTION PIPE Adapters shall be ductile iron or steel, Dresser Style 127 or 128, Smith-Blair Type 912 or 913, Baker Series 601 or 602, or District approved equal. Flange ends shall match the flange of the connecting pipe. 2.09 FLANGED COUPLING ADAPTERS FOR EXISTING ASBESTOS CEMENT PIPE Adapters shall be ductile iron, Dresser Style 127 or 128, Smith-Blair Series 912, or District approved equal. Flange ends shall match the flange of the connecting pipe. Verify in the field the actual outside diameter of the existing pipe to be connected. 2.10 LINING AND COATING FOR COUPLINGS Coat interior and exterior ferrous surfaces of flexible pipe couplings, transition couplings, and flanged coupling adapters with fusion-bonded epoxy per Standard Specification Section 09961. Coating shall be holiday free on interior surfaces. 2.11 JOINT HARNESSES A. Provide joint harnesses for flexible pipe couplings located in vaults and structures where the piping is not restrained or anchored. Joint harnesses of this design shall be limited to a maximum pipe size of 8 inches and only applies to steel pipe. B. Steel ring plates shall conform to ASTM A 36; ASTM A 283, Grade B, C or D; or ASTM A 285, Grade C. Ring plates shall be as shown on the Drawings. C. Tie bolts or studs shall be as shown in the following table. Bolt or stud material shall be high-strength alloy steel conforming to ASTM A 193, Grade B7. Nuts shall conform to ASTM A 194, Grade 2H. FLEXIBLE PIPE COUPLINGS STD SPEC 15122-3

Nominal Pipe Size (inches) Number of Bolts/Studs Diameter (inches) 2 2 5/8 3 2 5/8 4 2 5/8 6 2 5/8 8 2 5/8 D. Provide washers for each nut. Washers shall be of the same material as the nuts. 2.12 BOLTS, NUTS AND GASKETS FOR FLANGES See Standard Specification Section 15050. 2.13 WAX TAPE COATING See Standard Specification Section 09952. 2.14 POLYETHYLENE ENCASEMENT See Standard Specification Section 09954. 2.15 CORROSION CONTROL COMPONENTS See Standard Specification Section 13110. PART 3 - EXECUTION 3.01 INSTALLING COUPLINGS OR ADAPTERS A. Clean oil, grease, scale, and dirt from pipe ends. Repair any damage or holidays in the shop applied coating before installing couplings or adapters. Clean gaskets in flexible pipe couplings, transition couplings, and flanged coupling adapters before installing. B. Clean sleeve bolts and nuts by wire brushing before installing in end rings. Lubricate threads of bolts and nuts with oil or graphite prior to installation. Tighten nuts uniformly and in a progressive diametrically opposite sequence, and torque with a calibrated torque wrench. C. If couplings or adapters leak under pressure testing, loosen or remove the nuts and sleeve bolts, reset or replace the gaskets, reinstall or retighten the bolts and nuts, and retest the coupling or adapter. Couplings and adapters shall be watertight. D. After testing, wrap sleeve bolts and nuts of buried couplings or adapters with wax tape coating per Standard Specification Section 09952. E. Wrap buried couplings and adapters with polyethylene material per Standard Specification Section 09954. FLEXIBLE PIPE COUPLINGS STD SPEC 15122-4

F. Where couplings or adapters are installed on buried metallic pipe, provide bond wires across the coupling and bond the follower ring to the pipe per Standard Specification Section 13110. 3.02 INSTALLING FLANGED JOINTS See Standard Specification Section 15050 for installation instructions. 3.03 PAINTING AND COATING Coat flexible pipe couplings, transition couplings, flanged coupling adapters and joint harnesses located aboveground, or in vaults and structures, the same as the adjacent pipes and per Standard Specification Section 09900. Do not apply flame spray coating to fusion-bonded epoxy coated couplings. Apply finish coats in the field. Color of finish coat shall match color of the adjacent piping. 3.04 PRESSURE TESTING Test couplings and adapters at the same time that the connecting pipelines are pressure tested. See Standard Specification Section 15144 for pressure testing requirements. Repair leaks in piping and retest. 3.05 DISINFECTION See Standard Specification Section 15141 for chlorination requirements. END OF SECTION FLEXIBLE PIPE COUPLINGS STD SPEC 15122-5