KITO Armaturen GmbH. Protection. Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases

Similar documents
EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Safety Storage Cabinets

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

solarplus solar systems general features

Hydraulic control unit series

Fire & Explosion Risks in Service Stations

An Introduction to ATEX -

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Bypass level indicator With magnetic display Model BNA

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Rules for Classification and Construction Additional Rules and Guidelines

Technical Data. Dimensions

TECHNICAL INFORMATION

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

SunMaxx Solar Filling Station Operating Instructions

27 July 2009 I /08. Klenk GmbH Eichelstraße 15, D Bodnegg-Rotheidlen

Explosion of a gasoline vapour cloud formed in a hydrocarbon loaded effluents storage tank 10 December 1999 Arquata Scrivia Italy

Commercial Gas Water Heater

IMPORTANT SAFETY NOTICE

GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Tank Level Gauging, Safety Equipment & Inventory Management for Alcohol and Beverage Applications

API Flanged Safety Relief Valves Series 526 CATALOG

Nitrogen Blanketing for Methanol Storage and Transportation

POROUS BURNER - A New Approach to Infrared

INTERNATIONAL STANDARD

Basic Hydraulics and Pneumatics

The On-Load Tap-Changer for Maximum Switching Frequency More Switching Operations without Needing Maintenance.

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Air Eliminators and Combination Air Eliminators Strainers

Fire Pump Plan Review March 2010

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Material Safety Data Sheet

Druck PV 62x pneumatic/hydraulic pressure stations

TANKER - SHORE SAFETY CHECK-LIST

VAD Variable Area Desuperheaters

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

GUIDELINES FOR THE APPROVAL OF NATURAL GAS APPLIANCE INSTALLATIONS IN ISRAEL

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Certification of construction products - Fire dampers. Certification Rules 032

Pressure Vessels (Air Compressors) and LPG Tanks

Emergency Response Guide

PBX Series Quick Fit Connector Bimetallic Steam Traps

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

OSHA Tank Venting DEFINITIONS

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Industrial trucks for use in potentially explosive areas - placing on the market in compliance with Directive 94/9/EC and EN

Technology for Vacuum Systems. Instructions for use

Type 3353 Angle Seat Valve

ANALYSIS OF FIRE HAZARD AND SAFETY REQUIREMENTS OF A SEA VESSEL ENGINE ROOMS

COMBIMASS. Technical Data COMBIMASS eco-bio +

VAD. Variable Area Desuperheaters

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Factory owners must ensure the boiler is:

Reference in RID/ADR (restructured) to published standards and standards in preparation at CEN TC 23/256/261/268/286/296

Safety Data Sheet. MAPP Gas. Page 2 / 6. According to regulation (EC) 1907/2006. ROTHENBERGER Werkzeuge GmbH Industriestr.

ThermoSorb Desiccant Dryers

Variable V Area Flowmeter Rotameter The Original

During Various Aluminum Fabricating Operations

Float and Thermostatic Traps Series H, C and X

ADMINISTRATIVE SERVICES MANUAL

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

High pressure reactors Where are your limits?

TYPE TESTING PROCEDURE FOR CRANKCASE EXPLOSION RELIEF VALVES

Vacuum drying oven for non-flammable solvents

2010 Residential Water Heater Replacement Check List

Sample Written Program. For. Flammable Liquids

Electronic Flow Switches

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Product Bulletin INTEROX HYDROGEN PEROXIDE

Ethanol Vehicle and Infrastructure Codes and Standards Citations

BUSINESS PLAN CEN/TC 54 UNFIRED PRESSURE VESSELS EXECUTIVE SUMMARY

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union.

ANNEX 17 DRAFT AMENDMENTS TO SOLAS REGULATIONS II-2/4 AND II-2/16. Part B Prevention of fire and explosion

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

Operating instructions Supply system for flammable liquids. Labor

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Mechanical shaft seal types and sealing systems

HS-901(A) BASIC STEAM HEATING SYSTEMS

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Duplex Filters 40 FLDK 0008(C)-0120(C)

OREGON FIRE CODE Interpretations and Technical Advisories

Gas-Fired, Residential Storage Type Water Heaters

Self-Regulating Low Temperature Heating Cable

804 Ti Stand. Manual EN

Basic Safety Examination instructions

Transcription:

Trust is good, Protection is better. KITO Armaturen GmbH Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases Typical KITO flame arrester elements, which prevent the propagation of flames and explosions (both deflagration and detonation) in all kinds of tank farms. Our tested and certified tank accessory satisfies the current version of EN ISO 16852, which includes safety regulations and environmental protection. We are on fire when it comes to your safety.

Explosion-proof and endurance-burning-proof KITO -end-of-line devices Venting lines on tanks, vessels and pipelines that enable an on-going exchange of gases, must be protected with explosion-proof devices. These are called end-of-line deflagration or endurance-burning flame arresters (with the appropriate design). They enable tanks to breathe out flammable gases and breathe in fresh air unrestricted in total safety. A weather hood made of acrylic glass and strainer prevents the penetration of rain, dirt and foreign bodies. Weather hoods made of metal are also available. The KITO flame arrester element prevents flashback in the vessel. Simple versions of this are the KITO ventilation hoods (fig. 1-3). The KITO endurance burning type flame arrester is able to prevent a continuously burning flame from flashback into the vessel (fig. 1 and 2). In the event of a fire, the acrylic glass cover burns immediately and completely or the metal cover swings open. This enables the high temperature created by the burning gas/air or product vapour/air mixture at the flame arrester element to escape into atmosphere. In order to contain wasteful and polluting vapour losses, KITO valves are used. The flame arrester works on the same principle as a ventilation hood, but has additional valve inserts integrated to regulate pressure. There are KITO valves for pressure, for vacuum (fig. 4) or as combined pressure/vacuum valves (fig. 5). In many cases, where incoming and outgoing gas flow rates are similar, we recommend a combined KITO breather relief valve. However, where gas flow may strongly differ (e.g. on large tanks with differing pump flow rates for filling and discharging), the installation of separate KITO valves is usually more economical. We are at your disposal to calculate the number and size of valves in line with the applicable regulations required for your needs. To this end we require information about the tanks, the permissible pressures, the output of the pumps connected as well as the specific features of the product and relevant standards. Fig. 2: KITO Deflagration and endurance ventilation hood Fig. 3: KITO Deflagration proof ventilation hood Fig. 1: KITO Deflagration and endurance ventilation hood Fig. 4: KITO Deflagration proof vacuum relief valve Fig. 5: KITO Deflagration and endurance pressure and vacuum relief valve

Detonation proof KITO flame arresters In the event of explosive gas-air mixtures igniting in a pipeline, a (stable) detonation can develop from a deflagration under certain instances. The impact of such a detonation is considerable with greatly increased pressure and flame speed; our KITO detonation flame arresters are specifically designed for such scenarios. The fitted KITO flame arrester elements remains functional and arrests the flame front following the pressure wave. We can also develop certified devices for an unstable detonation (although these are not considered according to German regulations). The selection of suitable in-line detonation flame arrester is based on the classification of the required medium in explosive classes. Our range encompasses KITO devices for all explosion groups in various designs (fig. 6 onwards). Usage is limited to pressures < 1.2 bar; designs for higher pressures are also available (fig. 11). The devices can be installed anywhere and for any direction; almost all KITO in-line detonation flame arresters are also bi-directional, i.e. they provide protection from both sides. The KITO flame arresters have been optimised to reduce pressure drop with a cost-effective modular design. Liquid product detonation flame arresters are designed for the protection of liquid filled pipelines (fig. 8). Non-return valves are solely used in suction lines filled with liquids (fig. 9). Dry types of detonation flame arresters can also act as endurance burning flame arresters. For this purpose a pipe of a pre-determined length, based on the nominal diameter of the pipe, has to be connected to the outlet flange of the arrester. This installation replaces the ventilation hood (fig. 2). In some special system designs, e.g. installation in torch lines or thermal incineration plants, the incorporation of one or more thermal sensors on the KITO flame arrester element is mandatory for identifying an outbreak of fire. An appropriate circuit must be connected that triggers emergency measures against a potential stabilised burning caused by any incoming mixture. Fig. 6: KITO Bi-directional in-line detonation flame arrester, short-time Fig. 7: KITO Unidirectional in-line detonation flame arrester Fig. 9: KITO Detonation proof foot valve Fig. 10: KITO Unidirectional in-line detonation flame arrester, short-time, angled design Fig. 11: KITO Bi-directional in-line detonation flame arrester, short-time, even at increased pressures Fig. 8: KITO Unidirectional end-of-line liquid detonation flame arrester Fig. 12: KITO Bi-directional inline detonation flame arrester, short-time, shorttime

Deflagration-proof KITO flame arresters If explosive gases ignite in a pipe then the explosion initially starts as deflagration characterised by relatively low pressures and flame speeds. KITO in-line deflagration flame arresters (fig. 13 to fig. 16) are installed to prevent a flame spreading to other parts of the system. In contrast to detonation arresters, there are limits on the length of pipe between any possible source of ignition and the flame arrester. Where there are special conditions, e.g. installation in torch lines or thermal incineration plants, the incorporation of one or more thermal sensors on the KITO flame arrester element is mandatory for identifying an outbreak of fire (fig. 14). An appropriate circuit that triggers emergency measures to prevent a potential stabilized burning must be connected. Fig. 13: KITO Bi-directional in-line deflagration flame arrester, short-time Fig. 14: KITO Bi-directional in-line deflagration flame arrester, short-time Fig. 15: KITO Bi-directional in-line deflagration flame arrester, short-time Fig. 16: KITO Bi-directional in-line deflagration flame arrester, short-time Special areas of application for KITO devices We have specifically developed KITO valves for rail tank cars with a particularly low profile. There are versions for pressure, pressure/ vacuum and combinations with a gas compensation coupling (fig. 17) as well as with KITO flame arrester elements. In addition, devices without flame arrester elements and special designs for corrosive media are included in our range (fig. 18). We also manufacture special flame arresting devices for installation in tanks and road tankers (fig. 19). As well as detonation flame arresters, pressure, vacuum and combined valves are also available. These devices comply with the requirements for tanks according to ADR and RID. Fig. 17: KITO rail tank car valve Fig. 18: KITO container device Fig. 19: KITO container device

Design of the KITO flame arrester element KITO deflagration, detonation and endurance burning flame arresters comply with the international standard DIN EN ISO 16852. They have all been systematically typeapproved and are supplied with a CE conformity declaration. They therefore fully comply with the European directive 2014/34/EU (ATEX 100). The German Code of Practice 967 issued by VdTUEV and the German Ordinance on Industrial Safety and Health clearly specify the necessity for various tank flame arresters. We have developed the KITO grid - the centrepiece of our flame arrester elements - based on the principle of the Davy screen and its derivation, the gravel pot. Although the Davy screen and gravel pot no longer conform to the latest requirements, the KITO grid complies with all regulations and specifications. A KITO grid consists of two stainless steel strips, the height of which varies depending on the design. One flat and one corrugated stripe are wound tightly together, producing a gap of triangular section between the flat and the corrugated strip. This forms a circular element of variable diameter subject to the number of windings. The KITO flame arrester elements usually consist of one or more KITO grids as well as a surrounding KITO - casing. The gap of the KITO flame arrester element depends on the maximum experimental safe gap (MESG) of the material being protected (a material property) but should not be used as an equivalent. There are extensive tables and documentation available about this. Gaps for gas/air or vapour/air mixtures with unknown or deviating flashback characteristics can be determined in cooperation with test houses such as PTB; BAM or IBExU and manufactured by us. Also in such cases, the device can be CE marked through an individual verification procedure. Supplying special designs as OEM parts or components in line with ATEX is one of our specialities. KITO grid during the production process

Additional KITO devices In addition to our flame arresters according to international standard, we manufacture a variety of versions from in-line valves to end-of-line valves with particularly low set pressures (fig. 20). Special features and special versions such as e.g. heating with electricity (fig. 21), water or steam, inductive proximity switches etc. can be manufactured according to the client's specification. Our devices are of course also available in special materials e.g. plastics (fig. 22) or highly corrosion resistant materials as well as special designs. Fig. 20: KITO In-line pressure and vacuum relief valve Maintenance of KITO devices Fig. 21: KITO Deflagration and endurance pressure and vacuum relief valve with electrical heating Fig. 22: KITO In-line pressure or vacuum relief valve made of plastic One of the special features of all KITO devices is the minimal maintenance requirement. However, the type authorisation requires the devices to be checked regularly depending on the operating conditions. Being an approved manufacturer and registered maintenance company we will be pleased to give our advice about control checks as well as other maintenance and adjustment work and how to do this safely. We also offer training for your staff on how to maintain our devices, at our premises or on-site, whichever is more convenient for you. You can order spare parts for our KITO devices at short notice by specifying the type and factory number. This and other information is to be taken from the nameplate which identifies each device. Older devices without CE marking are not allowed to be replaced completely with spare parts. Please do not hesitate to contact us for advice in such cases. Provided by: Grotrian-Steinweg-Str. 1c, 38112 Braunschweig, Germany Postfach 8222. 38132 Braunschweig, Germany Tel. +49 (0)531 2 30 00-0 Fax: +49 (0)531 2 30 00-10 Email sales@kito.de Internet www.kito.de We prevent flashback. What more can you want?